Displaying publications 21 - 40 of 106 in total

Abstract:
Sort:
  1. Harwant S, Pravin D, Teng EM
    Med J Malaysia, 2005 Aug;60 Suppl D:69-70.
    PMID: 16315628
    Matched MeSH terms: Orthopedics/education*
  2. Nadia, M.N., Samsul Johari, M.A., Muhammad, M., Raha, A.R., Nurlia, Y.
    MyJurnal
    This study aimed to compare dexmedetomidine and propofol, in terms of haemodynamic parameters, respiratory rates and offset times, when used for sedation in patients undergoing elective orthopaedic and surgical procedures under regional anaesthesia. This was a prospective, randomised, single-blind study where 88 patients were recruited. Patients were randomised into two groups to receive either dexmedetomidine or propofol infusion. Central neuraxial blockade (spinal, epidural or combined spinal epidural) was performed. After ensuring an adequate block and stable haemodynamic parameters, dexmedetomidine was infused 15 minutes later at 0.4 μg/kg/hr, and propofol, at a target concentration of 2.5 μg/ml. Both drugs were titrated to achieve a bispectral index score of 70 before surgery commenced. Sedation level was monitored using the bispectral index score and assessed by the Observer Assessment of Alertness Scale score. Drug infusion was adjusted to maintain bispectral index scores ranging between 70-80 during surgery. Both groups showed reductions in mean arterial pressure and heart rate from baseline readings throughout the infusion time. However there was no significant reduction in the first 15 minutes from baseline (p > 0.05). Haemodynamic parameters and respiratory rate between both groups were not significantly different (p > 0.05). No patient demonstrated significant respiratory depression or SpO2 ≤ 95%. Offset times were also not significantly different between both groups (p = 0.594). There were no significant differences in haemodynamic parameters, respiratory rates and offset times between dexmedetomidine and propofol used for sedation in patients undergoing elective orthopaedic and surgical procedures under regional anaesthesia.
    Matched MeSH terms: Orthopedics
  3. N Z Med J, 1976 Jan 28;83(556):57.
    PMID: 766781
    Matched MeSH terms: Orthopedics/history
  4. Obaid, Kadhim Jawad, Sood, Suneet
    Medical Health Reviews, 2009;2009(1):59-73.
    MyJurnal
    Robotic surgery is a technique that uses mechanical, computercontrolled arms to conduct surgical operations. It carries the advantages of minimal access associated with laparoscopic surgery, and of precision associated with open surgery. It is also feasible to conduct robotic surgery with the surgeon far away, by “telerobotics”. The robot is more versatile than the human arm, and less susceptible to tremors. The view is excellent, and it is possible to conduct more intricate procedures than are possible with the human hand. Robotics has been in use for over seven years, and the initial experience shows that the success rate is over 90%, with only about 10% of cases needing to be converted to open surgery. Blood loss is low, and tumour margins in cancer surgery are satisfactory. Surgeons have used robotics for procedures in urology, gastrointestinal surgery, gynecology, cardiac surgery, neurosurgery, orthopedics, and other specialties. Presently, robotics suffers from two major disadvantages: one, that it is very expensive, and two, that robotic procedures take significantly longer than do open or laparoscopic procedures.
    Matched MeSH terms: Orthopedics
  5. Hui,J.H.P., Azura M., Lee, E.H.
    Malays Orthop J, 2009;3(1):4-12.
    MyJurnal
    Regenerative medicine using stem cell therapy has sparked much interest in this 21st century not only because of the controversies that surround the ethics involving pluripotent stem cells but their potential for use in the clinic. The ability of stem cells to repair and regenerate new tissues and organs holds tremendous promise for the treatment of many serious diseases and injuries. This review provides a brief summary of the current status of research in stem cells with special emphasis on where we are in terms of the possible clinical application of stem cell therapy in orthopaedic surgery. We look at the available evidence and examine the ethical issues and considerations associated with the clinical use of stem cells.
    Matched MeSH terms: Orthopedics
  6. Pan, K.L., Zolqarnain A., Ong, G.B.
    Malays Orthop J, 2009;3(2):55-57.
    MyJurnal
    Osteosarcoma occurring in the humerus is often confined to the proximal part, in which case, reconstruction after excision is less daunting. When the tumour spreads down the medullary cavity distally, a total humeral replacement is often required. This is costly and beyond the means of the average patient in a developing country. An amputation is often the procedure of first resort. We report a 13-year-old boy with osteosarcoma originating from the left proximal humerus, with involvement of the marrow reaching down to the distal diaphyseal-metaphyseal junction, leaving only 6 cm of the distal humerus intact after wide resection. Reconstruction of the defect was done with a composite cement-autoclaved autograft fixed to the remaining humerus with a plate. At 40 months of follow-up, the patient is well with normal function of the elbow, wrist and hand. Salvaging the limb despite near total involvement of the humerus by high grade osteosarcoma is possible using material available in the average orthopaedic operating room.
    Matched MeSH terms: Orthopedics
  7. Muzaffar TST, Imran Y, Iskandar MA, Zakaria A
    Med J Malaysia, 2005 Jul;60 Suppl C:26-9.
    PMID: 16381279
    Femoral interlocking nailing requires fluoroscopic assistance for insertion of the nail and distal screws. In this study, scattered radiation to the eye and hand of the operating surgeon was measured during the procedure. Thermo-luminescent dosimeter (TLD) was used to quantify the dose received by the surgeon. The mean radiation exposure time during the procedure was 3.89 minutes. The mean scattered radiation doses to the hand and eye were 0.27 mSv and 0.09 mSv per procedure respectively. These very low doses have made a surgeon very unlikely to receive more than the recommended annual dose limit set by the National Council on Radiological Protection.
    Matched MeSH terms: Orthopedics*
  8. Radhi AM, Masbah O, Shukur MH, Shahril Y, Taiman K
    Med J Malaysia, 2006 Feb;61 Suppl A:50-2.
    PMID: 17042230
    Orthopaedic procedures especially dynamic hip screw (DHS) fixation, interlocking nailing (ILN) of the tibia and femur require fluoroscopic assistance. Frequent exposure to radiation is a major concern to members of the orthopaedic surgical team. This study was undertaken to measure shallow (skin) dose to the operating team personnel and deep (whole body) dose to the surgeon during such procedures in view to provide guidelines to the operating team members regarding the number of procedures allowable for them to perform or assist annually. Skin dose for the operating personnel and whole body dose for the operating surgeon during 25 procedures; ten cases of DHS, seven and six cases of ILN of the tibia and femur respectively, was measured using Thermoluminescent Dosimeter (TLD) chips. The shallow radiation dose for theatre personnel ranged from 0.19 mSy to 0.61 per case while the deep dose for the surgeon was 0.28, 0.55 and 0.81 mSy for seven cases of tibial ILN, ten cases of DHS and six cases of femur ILN respectively. The surgeon has the highest radiation exposure than other theatre personnel and the whole body exposure for DHS was higher than that of for ILN. However, the estimated cumulative dose was still far below the permissible annual dose limit.
    Matched MeSH terms: Orthopedics/manpower*; Orthopedics/methods
  9. Zulkifli MM, Kadir AA, Elias A, Bea KC, Sadagatullah AN
    Malays Orthop J, 2017 Jul;11(2):7-14.
    PMID: 29021872 MyJurnal DOI: 10.5704/MOJ.1707.003
    Introduction: This study aimed to cross-culturally adapt a Malay version of Knee Injury and Osteoarthritis Outcome Score (KOOS) and to evaluate its psychometric properties in patients with knee osteoarthritis (OA). Materials and Methods: The English version KOOS was translated into a Malay version using forward and backward translation process, followed by face validity and content validity. Two hundred and twenty-six knee OA patients attending the Outpatient and Orthopaedic Clinics, Universiti Sains Malaysia Hospital, completed the Malay version KOOS. Construct validity using confirmatory factor analysis and internal reliability assessment were performed. Results: The results showed that the original five-factor model with 42 items failed to achieve acceptable values of the goodness of fit indices, indicating poor model fit. A new five-factor model of 26 items demonstrated acceptable level of goodness of fit (comparative fit index= 0.929, incremental fit index= 0.930, Tucker Lewis fit index= 0.920, root mean square error of approximation= 0.073 and Chisquared/degree of freedom= 2.183) indices to signify a model fit. The Cronbach's alpha value for the new model ranged from 0.776 to 0.946. The composite reliability values of each construct ranged between 0.819 and 0.921, indicating satisfactory to high level of convergent validity. Conclusion: The five-factor model with 26 items in the Malay version of KOOS questionnaire demonstrated a good degree of goodness of fit and was found to be valid, reliable and simple as an assessment tool for symptoms, pain, activity of daily living, sports and recreational activity and quality of life for Malaysian adults suffering from knee osteoarthritis.

    Study site: Outpatient and orthopedic clinics, Hospital Universiti Sains Malaysia (HUSM)
    Matched MeSH terms: Orthopedics
  10. Che Nor Zarida Che Seman, Zamzuri Zakaria, Zunariah Buyong, Mohd Shukrimi Awang, Ahmad Razali Md Ralib @ Md Raghib
    MyJurnal
    A novel injectable calcium phosphate bone cement (osteopaste) has been
    developed. Its potential application in orthopaedics as a filler of bone defects has been
    studied. The biomaterial was composed of tetra-calcium phosphate (TTCP) and tricalcium
    phosphate (TCP) powder. The aim of the present study was to evaluate the
    healing process of osteopaste in rabbit tibia.(Copied from article).
    Matched MeSH terms: Orthopedics
  11. Choy, Hew Hei, Khalib Abdul Latiff, Mohd Rohaizat Hassan, Hasanain Faisal Ghazi
    MyJurnal
    The uprising needs of traditional & complementary medicine (T&CM) despite the availability of conventional medical (CVM) treatments has gained a serious concern to the authorities in hospital care delivery systems. It was about suffices the supply and demand for T&CM and its absence may interfere the quality of patient care. Malaysia was not exempted of this phenomenon. Moreover, its rich tropical biodiversity and multi-ethnical medical systems promoted T&CM usage. This research was aimed to determine the overall T& CM preferences, the preferred future patient care services (FPCS) and its socio-demographic and warding characteristics. Using a self-administered standardised questionnaire, instrumented by cross sectional study, a total 132 warded patients in a UKM Medical Center (UKMMC) were interviewed. T&CM preferences were the composite of seven domains. The finding revealed that the T&CM preference was 64.4%, dominated by older age (66.2%), women (68.2%), low education (66.0%), employed (66.7%), high income (67.5%) and married (66.0%). Oncology (81.3%) and orthopaedic (75.7%) ward patients were more in preference compared to other wards. When asked about the FPCS preference, about 80.3% expected integrative medicine services to be provided, whereas the remaining were still exclusively preferred modern medicine (15.2%) and alternative medicine (4.5%) respectively. As conclusion, this study has affirmed that there is a great need towards T&CM among hospitalized patients who are accessible to modern CVM.
    Matched MeSH terms: Orthopedics
  12. Balaji G, Bhukya S, Nema S, Rajeswari M, Vellaipandi V
    Malays Orthop J, 2021 Mar;15(1):85-92.
    PMID: 33880153 DOI: 10.5704/MOJ.2103.013
    Introduction: Unstable ankle injuries require anatomical reduction and stabilisation for optimal outcome. In spite of adequate care, a few patients have poor outcome. In this study, we assessed the risk factors that predict the clinical outcomes in surgically treated unstable ankle fractures.

    Material and methods: This prospective cohort study was conducted on 68 patients who underwent surgical management for an unstable ankle injury. Demographic details, fracture type and associated medical comorbidities were recorded. Pre-operative radiographic assessment was done for all patients. At the end of one year follow-up, clinical (American Orthopaedic foot and ankle society-AOFAS and Olerud-Molander ankle - OMAS) scores and radiological parameters were assessed and analysed.

    Results: Fracture dislocation (0.008), diabetes mellitus (0.017), level of alchohol consumption (0.008) and pre-operative talocrural angle (TCA) > 100° (0.03) were significant predictors of poor outcomes as per AOFAS. Fracture dislocation (0.029), diabetes mellitus (0.004), pre-operative TCA > 100° (0.009), female gender (0.001), age more than 60 years (0.002) and open injuries (0.034) had significantly poor outcome as per OMAS. Other parameters (smoking, hypertension, classification, syndesmotic injury, medial clear space and tibiofibular overlap) did not affect the outcome significantly.

    Conclusion: Our study showed that poor outcome predictors in unstable ankle fractures are age >60 years, female gender, diabetes mellitus, alcohol consumption, fracture dislocation, open fractures and pre-op TCA >100°.

    Matched MeSH terms: Orthopedics
  13. Subramanian N
    Med J Malaysia, 1990 Sep;45(3):202-7.
    PMID: 2152081
    The following factors influencing vocational success or failure were selected and studied for their predictive value in a Rehabilitation Centre, age, family background, educational level, work history and work level, motivation, mental ability and physical disability. Graded numerical scores from 1 to 3 were assigned to these factors according to Lane et al. A cut-off score was tested and found to distinguish the successful from the unsuccessful groups. The individual factors found to differ significantly in the two groups were work history and skill, motivation, and physical disability. Mental ability, however, could not be tested adequately.
    Matched MeSH terms: Orthopedics*
  14. Yeap JS, Yeap JK, Ruslan NG
    Med J Malaysia, 1999 Dec;54(4):539.
    PMID: 11072481
    Matched MeSH terms: Orthopedics
  15. Chiu CK, Chan CYW, Cheung JPY, Cheung PWH, Gani SMA, Kwan MK
    J Orthop Surg (Hong Kong), 2021 2 12;29(1):2309499020988176.
    PMID: 33569998 DOI: 10.1177/2309499020988176
    PURPOSE: In this study we investigated on the personal protective equipment (PPE) usage, recycling, and disposal among spine surgeons in the Asia Pacific region.

    METHODS: A cross-sectional survey was carried out among spine surgeons in Asia Pacific. The questionnaires were focused on the usage, recycling and disposal of PPE.

    RESULTS: Two hundred and twenty-two surgeons from 19 countries participated in the survey. When we sub-analysed the differences between countries, the provision of adequate PPE by hospitals ranged from 37.5% to 100%. The usage of PPE was generally high. The most used PPE were surgical face masks (88.7%), followed by surgical caps (88.3%), gowns (85.6%), sterile gloves (83.3%) and face shields (82.0%). The least used PPE were powered air-purifying respirators (PAPR) (23.0%) and shoes/boots (45.0%). The commonly used PPE for surgeries involving COVID-19 positive patients were N95 masks (74.8%), sterile gloves (73.0%), gowns (72.1%), surgical caps (71.6%), face shields (64.4%), goggles (64.0%), shoe covers (58.6%), plastic aprons (45.9%), shoes/boots (45.9%), surgical face masks (36.5%) and PAPRs (21.2%). Most PPE were not recycled. Biohazard bins were the preferred method of disposal for all types of PPE items compared to general waste.

    CONCLUSIONS: The usage of PPE was generally high among most countries especially for surgeries involving COVID-19 positive patients except for Myanmar and Nepal. Overall, the most used PPE were surgical face masks. For surgeries involving COVID-19 positive patients, the most used PPE were N95 masks. Most PPE were not recycled. Biohazard bins were the preferred method of disposal for all types of PPE.

    Matched MeSH terms: Orthopedics*
  16. Chong DWQ, Iqbal AR, Kaur Jaj B, Zainab A, Nordin A, Abd Majid ND, et al.
    Med J Malaysia, 2020 11;75(6):691-697.
    PMID: 33219179
    INTRODUCTION: The quality of information and efficiency in the practice and care environments are important aspects of nursing care. The use of a reliable and valid scale can monitor the quality of handover and provide information for continuous improvement of practice. This study aims to describe the perception of nurses, on the domains of quality of information, efficiency, interaction and support and patient involvement.

    METHOD: A cross-sectional descriptive study was conducted among 450 nurses from 37 wards in Hospital Kuala Lumpur. Nurses on shift duty were recruited by convenience sampling from the Medical, Surgery, Obstetrics & Gynaecology, Orthopaedic and Paediatric wards. Using a validated questionnaire (Handover Evaluation Scale), nurses self-rated their perceptions using a 7-point scale and provided open-ended responses to the strengths and challenges that they faced. Descriptive and inferential analyses were done while open-ended questions were summarised based on key themes.

    RESULTS: A total of 414 nurses completed the survey (92.0% response rate). Nurses had an overall mean (SD) perception score of 5.01 (SD 0.56). They perceived good interaction and support during handover and on the quality of information that they received, with mean scores of 5.54 (SD 0.79) and 5.19 (SD 0.69), respectively. There was an association between the departments where the nurses worked and their overall perceptions on nursing handover (p<0.001). Interruptions being the most common theme emerged from the open-ended section.

    CONCLUSION: Despite having substantial interaction and support amongst nurses, opportunities for improvements were noted. Improvements in the quality of handover information and reducing interruptions should be the main emphases as these were perceived to be essential in the current handover practices by nurses.

    Matched MeSH terms: Orthopedics
  17. Joehaimey, J., M. Anwar Hau A., Kamil, M.K., Jaya Purany, S.P., Saadon, I., Chee Huan, P., et al.
    MyJurnal
    Introduction: The aim of this study is to determine the most common organisms isolated in diabetic foot infection and the most utilised antibiotic regimes as the first line of treatment.
    Methods: This is a retrospective record review of the National Orthopaedic Registry Malaysia among diabetes mellitus type 2 patients who had foot infections. All identified cases admitted to 18 government hospitals in Malaysia from the 1st January 2008 until the 31st December, 2009 were included in the study.
    Results: A total of 416 patients were included in the study. The most common organisms cultured were Proteus species (17.5%), Klebsiella species (17.1%) and Staphylococcus aureus (17.9%), while the most commonly used antibiotic was ampicillin/sulbactam (67.5%). None of the patients was appropriately treated with metronidazole, cefoperazone or fucidic acid. All patients were given appropriate antibiotics to treat Serratia infection.
    Conclusion: Significant number of patients with diabetic foot infections were not treated using appropriate antibiotics as the first line treatment.
    Matched MeSH terms: Orthopedics
  18. Mansor AF, Azmi AI, Zain MZM, Jamaluddin R
    Heliyon, 2020 Aug;6(8):e04812.
    PMID: 32913911 DOI: 10.1016/j.heliyon.2020.e04812
    Nickel-titanium shape memory alloy (NiTi) has a unique capacity to restore its initial shape after deformation, which is highly applicable to orthopaedic implantations, especially for the minimization of invasive surgeries. The high nickel content of this alloy can lead to unfavourable effects on the human body upon dissolution; thus, a reliable barrier of coatings on the NiTi surface is required to alleviate the nickel migration and increase its biocompatibility. In this paper, analyses of a titanium oxide layer development on NiTi surface using electrical discharge coating (EDC) process is presented. The recast layer thickness, crater sizes, and surface roughness were characterized based on five parameters; polarity, discharge duration, pulse interval, peak current, and gap voltage. The results show that the discharge duration is the most significant parameter to influence all responses, followed by peak current. The surface characteristics of the EDC substrate is depending on the crater formations and is highly correlated with the discharge energy intensity. As a result, appropriate parametric conditions of the electrical discharge coating process can enhance the NiTi surface for future medical applications, without compromising the shape memory effect.
    Matched MeSH terms: Orthopedics
  19. Lau CF, Malek S, Gunalan R, Saw A, Milow P, Song C
    Health Informatics J, 2023;29(4):14604582231218530.
    PMID: 38019888 DOI: 10.1177/14604582231218530
    The paediatric orthopaedic expert system analyses and predicts the healing time of limb fractures in children using machine learning. As far we know, no published research on the paediatric orthopaedic expert system that predicts paediatric fracture healing time using machine learning has been published. The University Malaya Medical Centre (UMMC) offers paediatric orthopaedic data, comprises children under the age of 12 radiographs limb fractures with ages recorded from the date and time of initial trauma. SVR algorithms are used to predict and discover variables associated with fracture healing time. This study developed an expert system capable of predicting healing time, which can assist general practitioners and healthcare practitioners during treatment and follow-up. The system is available online at https://kidsfractureexpert.com/.
    Matched MeSH terms: Orthopedics*
  20. Harjeet, S., Suhail, A., Shahril, Y., Masbah, O., Subanesh, S.
    Malays Orthop J, 2009;3(1):24-27.
    MyJurnal
    Fracture of the femoral neck is one of the most common types of osteoporotic fractures. Hemiarthroplasty continues to be a good option despite current calls for total hip arthroplasty in this subset of patients. The hemiarthroplasty is less expensive and easier to perform, and can be adequately carried out in smaller hospitals with basic orthopaedic facilities staffed by general orthopaedists. Functional demands of the elderly among Asians are often less compared to similar subsets of Western population on which most comparative hip studies are based. This study was undertaken to investigate the outcome for femoral neck fractures treated with conventional hemiarthroplasty. The authors hope to provide information based on local data as a reference for our doctors and patients.
    Matched MeSH terms: Orthopedics
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links