Displaying publications 21 - 40 of 45 in total

Abstract:
Sort:
  1. Tenekecioglu E, Serruys PW, Onuma Y, Costa R, Chamié D, Sotomi Y, et al.
    JACC Cardiovasc Interv, 2017 06 12;10(11):1115-1130.
    PMID: 28527768 DOI: 10.1016/j.jcin.2017.03.015
    OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device.

    BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.

    METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.

    RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.

    CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.

    Matched MeSH terms: Sirolimus/administration & dosage*; Sirolimus/adverse effects
  2. Kherad B, Waliszewski M, Leschke M, Kader MA, Bang LH, Ruiz-Poveda FL, et al.
    J Interv Cardiol, 2018 Jun;31(3):338-344.
    PMID: 29205492 DOI: 10.1111/joic.12472
    OBJECTIVES: To evaluate the 9-month safety and efficacy of polymer-free sirolimus eluting drug eluting stents in septuagenarians and octogenarians.

    METHODS: An all-comer, worldwide single armed trial (ClinicalTrials.gov Identifier NCT02629575) was conducted to demonstrate the safety and efficacy of an ultra-thin strut, polymer-free sirolimus eluting stent (PF-SES). The primary endpoint was the 9-month target revascularization rate (TLR). Secondary endpoints included the rates of major adverse cardiac events (MACE), stent thrombosis (ST) and bleeding (BARC) in septuagenarians (≥70 years, <80 years), and in octogenarians (≥80 years) to be compared to the younger patient group (<70 years).

    RESULTS: A total of 1607 patients were treated with PF-SES in the sub-70-year-old age group, 694 in septuagenarians, and 371 in the octogenarian patient group. At 9 months, the MACE rates were 7.2% in octogenarians, 5.3% in septuagenarians, and 3.0% in the younger patient group (P = 0.001). These were mostly driven by all-cause mortality (4.4% vs 1.9% vs 0.6%, P 

    Matched MeSH terms: Sirolimus/therapeutic use*
  3. Krackhardt F, Rosli MA, Leschke M, Schneider A, Sperling C, Heang TM, et al.
    Catheter Cardiovasc Interv, 2018 06;91(7):1221-1228.
    PMID: 28944613 DOI: 10.1002/ccd.27306
    OBJECTIVE: The objective of this study was to compare the safety and efficacy of a polymer-free sirolimus coated, ultrathin strut drug eluting stent (PF-SES) to its uncoated bare-metal stent (BMS) platform of identical stent architecture.

    BACKGROUND: Recently published randomized trials comparing BMS to DES with a focus on shortened dual-antiplatelet therapy reported incidences of stent thrombosis (ST) and bleeding complications (LEADERS FREE) in favor of drug eluting stents (DES).

    METHODS: Data of previously published large-sale, international, single-armed, multicenter, observational studies of ultra-thin PF-SES, and BMS were propensity score (PS) matched for selected lesion morphological and cardiovascular risk factors to compare target lesion revascularization (TLR), myocardial infarction, cardiac death, major adverse cardiac events (MACE), bleeding complications and ST rates. Primary endpoint in both studies was TLR at 9 months.

    RESULTS: At 9 months the rates of TLR was significantly lower in the PF-SES group as compared with patients treated with the BMS analogue of identical stent design (1.4% vs. 4.6%, P = 0.005). Likewise the 9-month MACE rates were lower in the PF-SES group (3.2% vs. 8.7%, P = 0.001) whereas there were no differences in the accumulated ST rates (0.5% vs. 1.5%, P = 0.109). Overall accumulated bleeding incidences (BARC 1-5) were not significantly different between PF-SES and BMS patients (1.8% vs. 2.7%, p = 0.388).

    CONCLUSIONS: PF-SES are superior over analogue BMS of identical stent architecture in daily clinical routine with lower rates of TLR and MACE in a PS-matched, unselected patient population without differences in accumulated ST rates and bleeding frequencies given the currently favored postprocedural comedication (ClinicalTrials.gov Identifier NCT02629575).

    Matched MeSH terms: Sirolimus/administration & dosage*; Sirolimus/adverse effects
  4. Khor ES, Wong PF
    Int J Biochem Cell Biol, 2018 Aug;101:64-73.
    PMID: 29857052 DOI: 10.1016/j.biocel.2018.05.016
    Accumulation of senescent endothelial cells can contribute to endothelium dysfunction. Suppression of MTOR signaling has been shown to delay senescence but the mechanism that underpins this effect, particularly one that involves miRNAs, remains to be further defined. This study sought to identify miRNAs involved in MTORC1-mediated inhibition of replicative senescence in endothelial cells. Pre-senescent HUVECs were prolonged treated with low dose rapamycin (1 nM), an MTOR inhibitor. Rapamycin treatment down-regulated the phosphorylated MTOR, RPS6 and 4EBP1 expressions, which confirmed MTORC1 suppression. Prolonged low dose rapamycin treatment has significantly reduced the percentage of senescence-associated beta galactosidase (SA-β gal) positively stained senescent cells and P16INK4A expression in these cells. On the contrary, the percentage of BrdU-labelled proliferating cells has significantly increased. RPTOR, a positive regulator of MTORC1 was knockdown using RPTOR siRNA to inhibit MTORC1 activation. RPTOR knockdown was evidenced by significant suppressions of RPTOR mRNA and protein expression levels. In these cells, the expression of miR-107 was down-regulated whereas miR-145-5p and miR-217 were up-regulated. Target gene prediction revealed PTEN as the target of miR-107 and this was confirmed by biotin pull-down assay. Over-expression of miR-107 has decreased PTEN expression, increased MTORC1 activity, induced cell cycle arrest at G0/G1 phase and up-regulated P16INK4A expression but mitigated tube formation. Collectively, our findings revealed that delayed endothelial replicative senescence caused by the inhibition of MTORC1 activation could be modulated by miR-107 via its influence on PTEN.
    Matched MeSH terms: Sirolimus
  5. Hamid, H., Ngu, P.A.H., Alipiah, F.M.
    MyJurnal
    The issue of classifying objects into groups when measured variables in an experiment are mixed has attracted the attention of statisticians. The Smoothed Location Model (SLM) appears to be a popular classification method to handle data containing both continuous and binary variables simultaneously. However, SLM is infeasible for a large number of binary variables due to the occurrence of numerous empty cells. Therefore, this study aims to construct new SLMs by integrating SLM with two variable extraction techniques, Principal Component Analysis (PCA) and two types of Multiple Correspondence Analysis (MCA) in order to reduce the large number of mixed variables, primarily the binary ones. The performance of the newly constructed models, namely the SLM+PCA+Indicator MCA and SLM+PCA+Burt MCA are examined based on misclassification rate. Results from simulation studies for a sample size of n=60 show that the SLM+PCA+Indicator MCA model provides perfect classification when the sizes of binary variables (b) are 5 and 10. For b=20, the SLM+PCA+Indicator MCA model produces misclassification rates of 0.3833, 0.6667 and 0.3221 for n=60, n=120 and n=180, respectively. Meanwhile, the SLM+PCA+Burt MCA model provides a perfect classification when the sizes of the binary variables are 5, 10, 15 and 20 and yields a small misclassification rate as 0.0167 when b=25. Investigations into real dataset demonstrate that both of the newly constructed models yield low misclassification rates with 0.3066 and 0.2336 respectively, in which the SLM+PCA+Burt MCA model performed the best among all the classification methods compared. The findings reveal that the two new models of SLM integrated with two variable extraction techniques can be good alternative methods for classification purposes in handling mixed variable problems, mainly when dealing with large binary variables.
    Matched MeSH terms: Sirolimus
  6. Montefusco A, D'Ascenzo F, Gili S, Smolka G, Chieffo A, Baumbach A, et al.
    Catheter Cardiovasc Interv, 2019 02 01;93(2):208-215.
    PMID: 30298593 DOI: 10.1002/ccd.27809
    OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM).

    BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed.

    METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points.

    RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation.

    CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.

    Matched MeSH terms: Sirolimus/administration & dosage*; Sirolimus/adverse effects
  7. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Sirolimus/administration & dosage*; Sirolimus/adverse effects
  8. Colombo A, Chandrasekhar J, Aquino M, Ong TK, Sartori S, Baber U, et al.
    Int J Cardiol, 2019 05 15;283:67-72.
    PMID: 30826192 DOI: 10.1016/j.ijcard.2019.01.053
    BACKGROUND: The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained release of sirolimus and luminal anti-CD34 coating for endothelial progenitor cell capture and rapid endothelialization.

    METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization.

    RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ± 11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12).

    CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS.

    GOV IDENTIFIER: NCT02183454.

    Matched MeSH terms: Sirolimus/pharmacology*
  9. Wong SK, Chin KY, Ima-Nirwana S
    Drug Des Devel Ther, 2019;13:3497-3514.
    PMID: 31631974 DOI: 10.2147/DDDT.S227738
    Kaempferol is a dietary bioflavonoid ubiquitously found in various types of plant. It possesses a wide range of medicinal properties suggesting its potential clinical utility that requires further investigation. The present review intends to highlight the efficacy of kaempferol and its molecular mechanisms of action in regulating bone metabolism. Many reports have acknowledged the bone-protecting property of kaempferol and kaempferol-containing plants using in vitro and in vivo experimental models. Kaempferol supplementation showed bone-sparing effects in newborn rats, glucocorticoid-induced and ovariectomy-induced osteoporotic models as well as bone fracture models. It achieves the bone-protective effects by inhibiting adipogenesis, inflammation, oxidative stress, osteoclastic autophagy and osteoblastic apoptosis while activating osteoblastic autophagy. The anti-osteoporotic effects of kaempferol are mediated through regulation of estrogen receptor, bone morphogenetic protein-2 (BMP-2), nuclear factor-kappa B (NF-κB), mitogen-activated protein kinase (MAPK) and mammalian target of rapamycin (mTOR) signaling pathways. In summary, kaempferol exhibits beneficial effects on skeleton, thus is potentially effective for the prophylaxis and treatment of osteoporosis.
    Matched MeSH terms: Sirolimus
  10. Montefusco A, De Filippo O, Gili S, Mancone M, Calcagno S, Cirillo P, et al.
    Coron Artery Dis, 2020 01;31(1):27-34.
    PMID: 31658146 DOI: 10.1097/MCA.0000000000000790
    AIMS: To assess the long-term outcomes of patients treated with sirolimus-eluting Stentys stent in a real-life setting.

    BACKGROUND: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available.

    METHODS: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones.

    RESULTS: After 13 months (interquartile range 5-32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71).

    CONCLUSION: Sirolimus-eluting Stentys stent may represent a potential solution for specific coronary anatomies such as bifurcation, ectasic, or tapered vessels. Risk of stent thrombosis appears related to clinical presentation with STEMI and to anatomic features, stressing the importance of the use of intracoronary imaging for self-expandable stents implantation.

    Matched MeSH terms: Sirolimus/administration & dosage
  11. Krackhardt F, Kočka V, Waliszewski M, Toušek P, Janek B, Trenčan M, et al.
    Medicine (Baltimore), 2020 Feb;99(8):e19119.
    PMID: 32080086 DOI: 10.1097/MD.0000000000019119
    Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.
    Matched MeSH terms: Sirolimus/therapeutic use*
  12. Ho HH, Sinaga DA, Arshad MKM, Kasim S, Lee JH, Khoo DZL, et al.
    Int J Cardiol Heart Vasc, 2020 Feb;26:100469.
    PMID: 32021903 DOI: 10.1016/j.ijcha.2020.100469
    Background: Amphilimus-eluting stent (AES) is a novel polymer-free drug eluting stent that combines sirolimus with fatty acid as antiproliferative drug and has shown promising results in percutaneous coronary intervention.We evaluated the clinical safety and efficacy of AES in an all-comers South-East Asian registry.

    Methods: Between May 2014 to April 2017, 268 patients (88% male, mean age 60.1 ± 10.8 years) with 291 coronary lesions were treated with AES. The primary endpoint was major adverse cardiac events (MACE) ie a composite of cardiovascular mortality, myocardial infarction (MI) and target lesion revascularization (TLR) at 12-month follow-up.

    Results: The majority of patients presented with acute coronary syndrome (75%) and 75% had multi-vessel disease on angiography. Diabetes mellitus was present in 123 patients (46%). The most common target vessel for PCI was left anterior descending artery (43%) followed by right coronary artery (36%), left circumflex (10%) and left main (6%).The majority of lesions were type B-C (85%) by ACC/AHA lesion classification. An average of 1.25 ± 0.5 AES were used per patient, with mean AES diameter of 3.1 ± 0.4 mm and average total length of 34.8 ± 19.4 mm.At 12-month follow-up, 4% of patients developed MACE. MACE was mainly driven by cardiovascular mortality (1.5%), MI (2%) and TLR (1.5%). The rate of stent thrombosis was 1.5%.

    Conclusion: In a contemporary all-comers South-East Asian registry with high rate of diabetes mellitus, AES was found to be efficacious with a low incidence of MACE observed at 12-month follow-up.

    Matched MeSH terms: Sirolimus
  13. Windecker S, Latib A, Kedhi E, Kirtane AJ, Kandzari DE, Mehran R, et al.
    N Engl J Med, 2020 03 26;382(13):1208-1218.
    PMID: 32050061 DOI: 10.1056/NEJMoa1910021
    BACKGROUND: Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited.

    METHODS: In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority.

    RESULTS: A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority).

    CONCLUSIONS: Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.).

    Matched MeSH terms: Sirolimus/administration & dosage; Sirolimus/analogs & derivatives*
  14. Muhammad Sakri MS, Abdul Rahman WFW, Tengku Din TADA, Idris FM, Jaafar H
    Indian J Pathol Microbiol, 2020 4 23;63(2):205-209.
    PMID: 32317516 DOI: 10.4103/IJPM.IJPM_496_19
    Background: Vascular endothelial growth factor receptors (VEGFRs) are major endothelial growth factor receptors that influence the growth of a tumor. Microvessel density.

    (: MVD) is the quantification method of various aspects of tumor vasculature that indicates angiogenic activity. This study aims to analyze the correlation between MVD to the expression of VEGFRs on breast cancer tissue.

    Materials and Method: A total of 60 N-methyl-N-nitrosourea (MNU)-induced breast carcinomas in rats were suppressed by using antiangiogenic drugs. The rats were then sacrificed, and the tumor was fixed in 10% formalin, paraffin embedded, and immunohistochemistry stained using VEGFRs and CD34.

    Result: One-way ANOVA test showed a significant difference in all markers that have been used (P < 0.05) on MNU-breast tumor treated with rapamycin (M= 90.1664, SD= 7.4487), PF4 (M= 93.7946, SD= 7.1303) and rapamycin + PF4 (M= 93.6990, SD= 1.8432). We obtained a significant reduction of MVD count on breast carcinoma for rapamycin group (M= 25.6786, SD= 9.7075) and rapamycin + PF4 group (M= 30.5250, SD= 13.6928) while PF4 group (M=47.7985, SD=4.8892) showed slightly increase compared to control (M= 45.1875, SD= 4.4786). There was a moderately strong, positive correlation between angiogenic markers; Flt-1 (r= 0.544, n=60, P < 0.005) and Flt-4 (r= 0.555, n= 60, P < 0.005) while Flk-1 (r= 0.797, n= 60, P < 0.005) showed a strong, positive correlation with MVD.

    Conclusion: MVD was strongly correlated to the VEGFRs expression on breast carcinoma.

    Matched MeSH terms: Sirolimus/therapeutic use*
  15. Haude M, Lee SWL, Worthley SG, Silber S, Verheye S, Rosli MA, et al.
    Catheter Cardiovasc Interv, 2020 05 01;95(6):1076-1084.
    PMID: 31489742 DOI: 10.1002/ccd.28483
    OBJECTIVES: To evaluate the long-term safety and efficacy of the novel combined sirolimus-eluting endothelial progenitor cell capture Combo stent (OrbusNeich, Fort Lauderdale, FL) at 5 years in the REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coated bio-Engineered stEnt) trial.

    BACKGROUND: Drug-eluting stents have limited restenosis and reintervention but are complicated by late and very late thrombosis and accelerated neoatherosclerosis. Alternative or adjunctive technologies are needed to address these limitations.

    METHODS: A total of 183 patients with de novo lesions in native coronary arteries were randomized 2:1 to Combo (n = 124) or Taxus Liberté (n = 59). Primary endpoint was 9 month angiographic in-stent late lumen loss and the secondary endpoint was the occurrence of major adverse events (MACE) through 5-year follow-up.

    RESULTS: Compared with Taxus, after 5 years the Combo stent was associated with similar rates of MACE (18.3% vs. 16.9%, p = .89), cardiac death (0.8% vs. 5.1%, p = .07), myocardial infarction (4.1% vs. 3.4%, p = .81), target lesion (9.4% vs. 10.2%, p = .78), and target vessel revascularization (14.4% vs. 11.9%, p = .73). No cases of definite stent thrombosis were reported in the Combo group. The follow-up rate at 5 years was 97.7%.

    CONCLUSION: At 5-year follow-up, the Combo stent remained clinically safe and effective with an overall low rate of MACE comparable to Taxus.

    Matched MeSH terms: Sirolimus/administration & dosage*; Sirolimus/adverse effects
  16. Krackhardt F, Waliszewski M, Kočka V, Toušek P, Janek B, Hudec M, et al.
    Cardiovasc Drugs Ther, 2020 06;34(3):335-344.
    PMID: 32212061 DOI: 10.1007/s10557-020-06963-5
    OBJECTIVES: The objective of this post hoc analysis was to analyze real-world dual antiplatelet therapy (DAPT) regimens following polymer-free sirolimus-eluting stent (PF-SES) implantations in an unselected patient population.

    METHODS: Patient-level data from two all-comers observational studies (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled and analyzed in terms of their primary endpoint. During the data verification process, we observed substantial deviations from DAPT guideline recommendations. To illuminate this gap between clinical practice and guideline recommendations, we conducted a post hoc analysis of DAPT regimens and clinical event rates for which we defined the net adverse event rate (NACE) consisting of target lesion revascularization (TLR, primary endpoint of all-comers observational studies) all-cause death, myocardial infarction (MI), stent thrombosis (ST), and bleeding events. A logistic regression was utilized to determine predictors why ticagrelor was used in stable coronary artery disease (CAD) patients instead of the guideline-recommended clopidogrel.

    RESULTS: For stable CAD, the composite endpoint of clinical, bleeding, and stent thrombosis, i.e., NACE, between the clopidogrel and ticagrelor treatment groups was not different (5.4% vs. 5.1%, p = 0.745). Likewise, in the acute coronary syndrome (ACS) cohort, the NACE rates were not different between both DAPT strategies (9.2% vs. 9.3%, p = 0.927). There were also no differences in the accumulated rates for TLR, myocardial infarction ([MI], mortality, bleeding events, and stent thrombosis in elective and ACS patients. The main predictors for ticagrelor use in stable CAD patients were age

    Matched MeSH terms: Sirolimus/administration & dosage*; Sirolimus/adverse effects
  17. Bu-Hui L, Mei-Zi W, Wei S, Yi-Gang W, Wei WU, Qi-Jun F, et al.
    Zhongguo Zhong Yao Za Zhi, 2020 Oct;45(20):4805-4811.
    PMID: 33350250 DOI: 10.19540/j.cnki.cjcmm.20200630.602
    Hypoxia-inducible factors(HIFs)are the key transcription factors that sense and regulate cellular oxygen concentration in vivo. HIF-1 is composed of 2 subunits,α and β,in which,the molecular regulatory mechanism of HIF-1α involves the main processes of its degradation and activation. The degradation of HIF-1α is regulated by oxygen-dependent pathways,including "von hippel-lindau protein(pVHL)-dependent pathway" and "pVHL-independent pathway". The activation of HIF-1α is regulated by oxygen-independent pathways,including mammalian target of rapamycin(mTOR)/eukaryotic initiation factor 4 E-binding protein 1(4 EBP1)/HIF-1α pathway,phosphatidylinositol 3-kinase(PI3 K)/proteirrserinc-threonine kinases(Akt)/HIF-1α pathway and silent information regulator1(Sirt1)/HIF-1α pathway. In recent years,based on the molecular regulatory mechanism of HIFs,Roxadustat,a new drug for the treatment of renal anemia has been developed. Besides, some macromolecular substances with similar pharmacological effect to HIFs have been found in the extracts from Chinese herbal medicine(CHM),such as emodin,notoginseng triterpenes,honokiol and clematichinenoside. These natural macromolecular substances play the regulatory roles in inflammatory response,epigenetic modification and auto-phagy. It is worth noting that,for common hypoxic-related diseases including diabetic kidney disease,HIFs-mediated "pyroptosis" may be a new target of CHMs for clearing dampness and heat and its representative classical prescriptions(Ermiao Pills)in treating inflammatory injury in cells and tissues.
    Matched MeSH terms: Sirolimus
  18. Jaffar NFN, Muhammad Sakri MS, Jaafar H, Wan Abdul Rahman WF, Tengku Din TADA
    Asian Pac J Cancer Prev, 2020 Oct 01;21(10):2919-2925.
    PMID: 33112549 DOI: 10.31557/APJCP.2020.21.10.2919
    OBJECTIVE: To analyze the effect of sirolimus and sunitinib in blocking the tumor growth and to evaluate the expressions of estrogen receptor (ER), progesterone receptor (PgR), and human epidermal growth factor receptor-2 (HER2/neu) after treated with sirolimus and sunitinib.

    METHODS: Thirty-two female Sprague Dawley rats at age 21-days old were administered intraperitoneally with N-Methyl-N-Nitroso Urea (NMU), dosed at 70mg/kg body weight. The rats were divided into 4 groups; Group 1 (Control, n=8), Group 2 (Sirolimus, n=8), Group 3 (Sunitinib, n=8) and Group 4 (Sirolimus+Sunitinib, n=8), being treated twice when the tumor reached the size of 14.5±0.5 mm and subsequently sacrificed after 5 days. The protein expressions of ER, PgR and HER2/neu of the tumor tissues were evaluated by using immunohistochemistry analysis.

    RESULTS: Treatment with sirolimus alone lowered expressions of ER and PgR of breast cancer and reduced tumor size. There was no significant difference of ER and PgR expressions between control and sunitinib treated tumor. Sunitinib treated tumors reduce in diameter after the first treatment, however the diameter increases after the second treatment. Histologically, sunitinib treated tumor did not show any aggressive invasive carcinoma of no special type (NST) histological subtypes. In addition, all NMU-induced tumors are HER2/neu-negative scoring.

    CONCLUSION: Sirolimus is neither synergistic nor additive with sunitinib for breast cancer treatment.
    .

    Matched MeSH terms: Sirolimus/administration & dosage
  19. Krackhardt F, Waliszewski M, Wan Ahmad WA, Kočka V, Toušek P, Janek B, et al.
    PLoS One, 2020;15(1):e0226606.
    PMID: 31929543 DOI: 10.1371/journal.pone.0226606
    BACKGROUND: The objective of this study was to assess regional and ethnic differences in an unselected patient population treated with polymer-free sirolimus-eluting stents (PF-SES) in Asia and Europe.

    METHODS: Two all-comers observational studies based on the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were combined for data analysis to assure sufficient statistical power. The primary endpoint was the accumulated target lesion revascularization (TLR) rate at 9-12 months.

    RESULTS: Of the total population of 7243 patients, 44.0% (3186) were recruited in the Mediterranean region and 32.0% (2317) in central Europe. The most prominent Asian region was South Korea (17.6%, 1274) followed by Malaysia (5.7%, 413). Major cardiovascular risk factors varied significantly across regions. The overall rates for accumulated TLR and MACE were low with 2.2% (140/6374) and 4.4% (279/6374), respectively. In ACS patients, there were no differences in terms of MACE, TLR, MI and accumulated mortality between the investigated regions. Moreover, dual antiplatelet therapy (DAPT) regimens were substantially longer in Asian countries even in patients with stable coronary artery disease as compared to those in Europe.

    CONCLUSIONS: PF-SES angioplasty is associated with low clinical event rates in all regions. Further reductions in clinical event rates seem to be associated with longer DAPT regimens.

    Matched MeSH terms: Sirolimus
  20. Muhammad Sakri MS, Tengku Din TADA, Jaafar H, Gopalan V, Wan Abdul Rahman WF
    Int J Immunopathol Pharmacol, 2022;36:20587384211059673.
    PMID: 35037503 DOI: 10.1177/20587384211059673
    Angiogenesis is the process of new vascular formation, which is derived from various factors. For suppressing cancer cell growth, targeting angiogenesis is one of the therapeutic approaches. Vascular endothelial growth factor family receptors, including Flt-1, Flk-1 and Flt-4, have been found to play an essential role in regulating angiogenesis. Rapamycin is a macrolide compound with anti-proliferative properties, while platelet factor-4 (PF-4) is an antiangiogenic ELR-negative chemokine. Rapamycin inhibits mTOR ligands activation, thus suppressing cell proliferation, while PF-4 inhibits cell proliferation through several mechanisms. In the present study, we evaluated the effects of rapamycin and platelet factor-4 toward breast carcinoma at the proteomic and genomic levels. A total of 60 N-Methyl-N-Nitrosourea-induced rat breast carcinomas were treated with rapamycin, platelet factor-4 and rapamycin+platelet factor-4. The tumours were subsequently subjected to immunohistochemical protein analysis and polymerase chain reaction gene analysis. Protein analysis was performed using a semiquantitative scoring method, while the mRNA expression levels were analysed based on the relative expression ratio. There was a significant difference in the protein and mRNA expression levels for the selected markers. In the rapamycin+platelet factor-4-treated group, the Flt-4 marker was downregulated, whereas there were no differences in the expression levels of other markers, such as Flt-1 and Flk-1. On the other hand, platelet factor-4 did not exhibit a superior angiogenic inhibiting ability in this study. Rapamycin is a potent antiangiogenic drug; however, platelet factor-4 proved to be a less effective drug of anti-angiogenesis on rat breast carcinoma model.
    Matched MeSH terms: Sirolimus/administration & dosage*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links