Displaying publications 21 - 40 of 1046 in total

Abstract:
Sort:
  1. Abdulkareem KH, Mostafa SA, Al-Qudsy ZN, Mohammed MA, Al-Waisy AS, Kadry S, et al.
    J Healthc Eng, 2022;2022:5329014.
    PMID: 35368962 DOI: 10.1155/2022/5329014
    Coronavirus disease 2019 (COVID-19) is a novel disease that affects healthcare on a global scale and cannot be ignored because of its high fatality rate. Computed tomography (CT) images are presently being employed to assist doctors in detecting COVID-19 in its early stages. In several scenarios, a combination of epidemiological criteria (contact during the incubation period), the existence of clinical symptoms, laboratory tests (nucleic acid amplification tests), and clinical imaging-based tests are used to diagnose COVID-19. This method can miss patients and cause more complications. Deep learning is one of the techniques that has been proven to be prominent and reliable in several diagnostic domains involving medical imaging. This study utilizes a convolutional neural network (CNN), stacked autoencoder, and deep neural network to develop a COVID-19 diagnostic system. In this system, classification undergoes some modification before applying the three CT image techniques to determine normal and COVID-19 cases. A large-scale and challenging CT image dataset was used in the training process of the employed deep learning model and reporting their final performance. Experimental outcomes show that the highest accuracy rate was achieved using the CNN model with an accuracy of 88.30%, a sensitivity of 87.65%, and a specificity of 87.97%. Furthermore, the proposed system has outperformed the current existing state-of-the-art models in detecting the COVID-19 virus using CT images.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  2. Abdullah A, Abdul Rahman R, Aziz S, Abu Bakar S, AbAziz AA
    Med J Malaysia, 2013;68(1):76-8.
    PMID: 23466775 MyJurnal
    Nasal obstruction in neonates is a potentially fatal condition because neonates are obligatory nasal breathers. Bilateral choanal atresia is therefore a neonatal emergency. Several approaches for corrections of choanal atresia are available including the helium laser: YAG. A 5-year-old Chinese girl born with bilateral choanal atresia, had birth asphyxia that required intubation. She underwent multiple surgeries for correction of choanal atresia at other hospitals but failed to improve. She was referred to Universiti Kebangsaan Malaysia Medical Center (UKMMC) after presenting with intermittent respiratory distress and cyanosis following an upper respiratory tract infection. A repeat computed tomography (CT) scan done preoperatively showed complete bony stenosis over the left choana and finding was confirmed by examination under general anesthesia. She underwent endoscopic transnasal removal of left bony atretic plate. There was no intra or postoperative complications. During follow up 10 years later, the airway on both sides remains patent.
    Matched MeSH terms: Tomography, X-Ray Computed
  3. Abdullah A, Mahmud MR, Maimunah A, Zulfiqar MA, Saim L, Mazlan R
    Ann Acad Med Singap, 2003 Jul;32(4):442-5.
    PMID: 12968546
    INTRODUCTION: Accurate preoperative imaging of the temporal bone in patients receiving cochlear implants is important. High resolution computed tomography (HRCT) and magnetic resonance (MR) imaging are the 2 preoperative imaging modalities that provide critical information on abnormalities of the otic capsule, pneumatisation of the mastoid, middle ear abnormalities, cochlear ducts patency and presence of cochlear nerve.

    MATERIALS AND METHODS: The HRCT and MR imaging in 46 cochlear implant patients in our department were reviewed.

    RESULTS: Majority of our patients [34 patients (73.9%)] showed normal HRCT of the temporal bone; 5 (10.9%) patients had labyrinthitis ossificans, 2 (4.3%) had Mondini's abnormality and 2 (4.3%) had middle ear effusion. One patient each had high jugular bulb, hypoplasia of the internal auditory canal and single cochlear cavity, respectively.

    CONCLUSION: The above findings contribute significantly to our surgical decisions regarding candidacy for surgery, side selection and surgical technique in cochlear implantation.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  4. Abdullah AC, Adnan JS, Rahman NA, Palur R
    Malays J Med Sci, 2017 Mar;24(1):104-112.
    PMID: 28381933 DOI: 10.21315/mjms2017.24.1.11
    INTRODUCTION: Computed tomography (CT) is the preferred diagnostic toolkit for head and brain imaging of head injury. A recent development is the invention of a portable CT scanner that can be beneficial from a clinical point of view.

    AIM: To compare the quality of CT brain images produced by a fixed CT scanner and a portable CT scanner (CereTom).

    METHODS: This work was a single-centre retrospective study of CT brain images from 112 neurosurgical patients. Hounsfield units (HUs) of the images from CereTom were measured for air, water and bone. Three assessors independently evaluated the images from the fixed CT scanner and CereTom. Streak artefacts, visualisation of lesions and grey-white matter differentiation were evaluated at three different levels (centrum semiovale, basal ganglia and middle cerebellar peduncles). Each evaluation was scored 1 (poor), 2 (average) or 3 (good) and summed up to form an ordinal reading of 3 to 9.

    RESULTS: HUs for air, water and bone from CereTom were within the recommended value by the American College of Radiology (ACR). Streak artefact evaluation scores for the fixed CT scanner was 8.54 versus 7.46 (Z = -5.67) for CereTom at the centrum semiovale, 8.38 (SD = 1.12) versus 7.32 (SD = 1.63) at the basal ganglia and 8.21 (SD = 1.30) versus 6.97 (SD = 2.77) at the middle cerebellar peduncles. Grey-white matter differentiation showed scores of 8.27 (SD = 1.04) versus 7.21 (SD = 1.41) at the centrum semiovale, 8.26 (SD = 1.07) versus 7.00 (SD = 1.47) at the basal ganglia and 8.38 (SD = 1.11) versus 6.74 (SD = 1.55) at the middle cerebellar peduncles. Visualisation of lesions showed scores of 8.86 versus 8.21 (Z = -4.24) at the centrum semiovale, 8.93 versus 8.18 (Z = -5.32) at the basal ganglia and 8.79 versus 8.06 (Z = -4.93) at the middle cerebellar peduncles. All results were significant with P-value < 0.01.

    CONCLUSIONS: Results of the study showed a significant difference in image quality produced by the fixed CT scanner and CereTom, with the latter being more inferior than the former. However, HUs of the images produced by CereTom do fulfil the recommendation of the ACR.

    Matched MeSH terms: Tomography, X-Ray Computed
  5. Abdullah AH, Todo M, Nakashima Y
    Med Eng Phys, 2017 06;44:8-15.
    PMID: 28373012 DOI: 10.1016/j.medengphy.2017.03.006
    Femoral bone fracture is one of the main causes for the failure of hip arthroplasties (HA). Being subjected to abrupt and high impact forces in daily activities may lead to complex loading configuration such as bending and sideway falls. The objective of this study is to predict the risk of femoral bone fractures in total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). A computed tomography (CT) based on finite element analysis was conducted to demonstrate damage formation in a three dimensional model of HAs. The inhomogeneous model of femoral bone was constructed from a 79 year old female patient with hip osteoarthritis complication. Two different femoral components were modeled with titanium alloy and cobalt chromium and inserted into the femoral bones to present THA and RHA models respectively. The analysis included six configurations, which exhibited various loading and boundary conditions, including axial compression, torsion, lateral bending, stance and two types of falling configurations. The applied hip loadings were normalized to body weight (BW) and accumulated from 1 BW to 3 BW. Predictions of damage formation in the femoral models were discussed as the resulting tensile failure as well as the compressive yielding and failure elements. The results indicate that loading directions can forecast the pattern and location of fractures at varying magnitudes of loading. Lateral bending configuration experienced the highest damage formation in both THA and RHA models. Femoral neck and trochanteric regions were in a common location in the RHA model in most configurations, while the predicted fracture locations in THA differed as per the Vancouver classification.
    Matched MeSH terms: Tomography, X-Ray Computed*
  6. Abdullah B, Vengathajalam S, Md Daud MK, Wan Mohammad Z, Hamizan A, Husain S
    J Asthma Allergy, 2020;13:523-531.
    PMID: 33149624 DOI: 10.2147/JAA.S275536
    Purpose: The allergic phenotype of chronic rhinosinusitis (CRS) and central compartment atopic disease (CCAD) have been described. The CCAD is a radiological phenotype in patients with CRS that presents as a central mucosal disease due to allergy. The subset of patients having chronic rhinosinusitis with nasal polyps (CRSwNP) has not been well characterized. We aim to describe the clinical and radiological characterizations of patients presenting with the allergic phenotype of CRSwNP.

    Patients and Methods: A cross-sectional study at a tertiary hospital was performed. Adult patients diagnosed with CRSwNP who had both allergology and radiological assessments were enrolled. The symptoms of allergic rhinitis, Lund-Kennedy (LK) endoscopic scoring, Lund-Mackay (LM) computed tomography scan of paranasal sinuses (CTPNS) scoring, CCAD features, skin prick test (SPT) and level of specific IgE were assessed. All the patients underwent SPT for house dust mites.

    Results: A total of 38 patients were enrolled. Symptoms, endoscopic and CTPNS scores were higher in the allergy and CCAD groups compared to the nonallergy and nonCCAD groups. The symptom of "need to blow nose" was statistically significant in allergy vs nonallergy (p=0.01) and CCAD vs nonCCAD (p=0.02). There were significant differences in the endoscopic scores in both allergy and CCAD (allergy vs nonallergy, p=0.01; CCAD vs nonCCAD, p=0.03), and CT scores in both allergy and CCAD (allergy vs nonallergy, p=0.02; CCAD vs nonCCAD, p=0.02). All patients with CCAD have worse scoring than nonCCAD (LK score, p=0.03; LM score, p=0.02). Patients with allergy have more polypoidal involvement of the middle turbinates (left middle turbinate, p=0.141; right middle turbinate, p=0.074) and CCAD (left middle turbinate, p=0.017; right middle turbinate, p=0.009) than nonallergy and nonCCAD patients.

    Conclusion: Allergic phenotype of CRSwNP has a worse clinical and radiological disease burden. Optimal treatment of allergy is essential for a better outcome.

    Matched MeSH terms: Tomography, X-Ray Computed
  7. Abdullah B, Lim EH, Mohamad H, Husain S, Aziz ME, Snidvongs K, et al.
    Surg Radiol Anat, 2019 May;41(5):543-550.
    PMID: 30542929 DOI: 10.1007/s00276-018-2157-3
    PURPOSE: The variations of the anterior ethmoidal artery (AEA) in different populations should be recognized by surgeons to prevent unwarranted complications during surgery. The aim of this study was to assess the anatomical variations of AEA in Asian population.

    METHODS: A cross-sectional study of 252 AEA identified by computed tomography (CT) of the paranasal sinuses. The multiplanar CT images were acquired from SOMATOM® Definition AS+ and reconstructed to axial, coronal and sagittal view at 1 mm slice thickness.

    RESULTS: 42.5% of AEA was within skull base (grade I), 20.2% at skull base (grade II) and 37.3% coursed freely below skull base (grade III). The prevalence of supraorbital ethmoid cell (SOEC) and suprabullar cell (SBC) was 29.8% and 48.0%. The position of AEA at skull base has significant association with SOEC (p 

    Matched MeSH terms: Tomography, X-Ray Computed
  8. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2015 Jan;25(1):246-57.
    PMID: 25189152 DOI: 10.1007/s00330-014-3391-7
    OBJECTIVE: This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system.

    METHODS: Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance.

    RESULTS: Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method.

    CONCLUSION: This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients.

    KEY POINTS: • Clinical experience on liver thermal ablation using CT-guided robotic system is reported. • The technical success, radiation dose, safety and performance level were assessed. • Thermal ablations were successfully performed, with an average performance score of 4.4/5.0. • Robotic-assisted ablation can potentially increase capabilities of less skilled interventional radiologists. • Cost-effectiveness needs to be proven in further studies.

    Matched MeSH terms: Tomography, X-Ray Computed
  9. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2014 Jan;24(1):79-85.
    PMID: 23928933 DOI: 10.1007/s00330-013-2979-7
    OBJECTIVE: Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles.

    METHODS: We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions).

    RESULTS/CONCLUSION: Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff.

    KEY POINTS: • An early experience of robotic-assisted radiofrequency ablation is reported • Robotic-assisted RFA improves accuracy of hepatic lesion targeting • Robotic-assisted RFA makes the procedure technically easier with significant lower radiation dose.

    Matched MeSH terms: Tomography, X-Ray Computed
  10. Abdullah BJ, Liam CK, Kaur H, Mathew KM
    Br J Radiol, 1997 Oct;70(838):1063-5.
    PMID: 9404213
    Lipoma of the parapharyngeal space is very rare, only three cases having been reported in the literature. A parapharyngeal space lipoma causing obstructive sleep apnoea has not been reported before. A 60-year-old man presented at the ear, nose and throat (ENT) clinic with a history of loud snoring associated with sleep apnoea secondary to a right parapharyngeal space lipoma. The causes of sleep apnoea and the radiological features of a parapharyngeal space lipoma are discussed.
    Study site: ENT clinic, University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Tomography, X-Ray Computed
  11. Abdullah H, Jiyen K, Othman N
    BMJ Case Rep, 2017 Sep 27;2017.
    PMID: 28954754 DOI: 10.1136/bcr-2017-221466
    We present a case of a 20-year-old Malay man with underlying tuberculous (TB) lymphadenitis who presented with shortness of breath and found to have submitral left ventricular aneurysm (SLVA). SLVA is well recognised but rare. Incidence of SLVA in Malay has never been documented. This is the first reported case of SLVA in Malays with concomitant thoracic aorta mycotic aneurysm. TB has been reported to be associated with SLVA. Treatment is either surgical or conservative. Imaging is required for diagnosis and preoperative assessment. Multimodality imaging include echocardiography (ECHO), cardiac CTangiography and the robust multiparametric cardiac MR (CMR). ECHO is the first line imaging and useful for initial detection of the aneurysm. CMR including the late gadolinium enhancement allows excellent visualisation of the LV aneurysm, tissue characterisation, cardiac function and detection of associated pathology as shown in this case.
    Matched MeSH terms: Tomography, X-Ray Computed
  12. Abdullah J, Rushdan A, Hamzah M, Ariff AR, Rani A
    Ann. Transplant., 1999;4(3-4):28-31.
    PMID: 10853777
    Four patients underwent reconstruction of anterior cranial fossa of skull defects between November 1997 and January 1998. All of them had traumatic anterior cranial fossa defect and were reconstructed with lyophilised bovine cortical bone graft. There was no cerebrospinal fluid leakage, meningitis, extradural abscess or other infections. This study demonstrates that the use of bovine bone graft in the reconstruction of anterior base defects is safe.
    Matched MeSH terms: Tomography, X-Ray Computed
  13. Abdullah JM, Rahman ZA, Ariff AR, Jaafar H, Phang KS
    Singapore Med J, 2004 Jun;45(6):286-8.
    PMID: 15181525
    Rhabdoid tumour is a rare childhood tumour with poor prognosis. We report a 13-month-old Malay girl suffering from this tumour that was located at the left fronto-temporo-parietal region of the brain. Computed tomography showed a large irregular enhancing mass that caused obstructive hydrocephalus. The tumour did not reduce in size after three operations and finally the patient succumbed to the disease four months after diagnosis.
    Matched MeSH terms: Tomography, X-Ray Computed
  14. Abdullah JY, Rajion ZA, Martin AG, Jaafar A, Ghani ARI, Abdullah JM
    Neurocirugia (Astur : Engl Ed), 2019 02 16;30(3):115-123.
    PMID: 30782505 DOI: 10.1016/j.neucir.2018.12.004
    INTRODUCTION: Intracranial volume (ICV) is an important tool in the management of patients undergoing decompressive craniectomy (DC) surgery. The aim of this study was to validate ICV measurement applying the shape-based interpolation (SBI) method using open source software on computed tomography (CT) images.

    METHODS: The pre- and post-operative CT images of 55 patients undergoing DC surgery were analyzed. The ICV was measured by segmenting every slice of the CT images, and compared with estimated ICV calculated using the 1-in-10 sampling strategy and processed using the SBI method. An independent t test was conducted to compare the ICV measurements between the two different methods. The calculation using this method was repeated three times for reliability analysis using the intraclass correlations coefficient (ICC). The Bland-Altman plot was used to measure agreement between the methods for both pre- and post-operative ICV measurements.

    RESULTS: The mean ICV (±SD) were 1341.1±122.1ml (manual) and 1344.11±122.6ml (SBI) for the preoperative CT data. The mean ICV (±SD) were 1396.4±132.4ml (manual) and 1400.53±132.1ml (SBI) for the post-operative CT data. No significant difference was found in ICV measurements using the manual and the SBI methods (p=.983 for pre-op, and p=.960 for post-op). The intrarater ICC showed a significant correlation; ICC=1.00. The Bland-Altman plot showed good agreement between the manual and the SBI method.

    CONCLUSION: The shape-based interpolation method with 1-in-10 sampling strategy gave comparable results in estimating ICV compared to manual segmentation. Thus, this method could be used in clinical settings for rapid, reliable and repeatable ICV estimations.

    Matched MeSH terms: Tomography, X-Ray Computed*
  15. Abdullah JY, Saidin M, Rajion ZA, Hadi H, Mohamad N, Moraes C, et al.
    Malays J Med Sci, 2021 Feb;28(1):1-8.
    PMID: 33679214 DOI: 10.21315/mjms2021.28.1.1
    Perak Man, named after the state where the skeleton was found, was the most complete skeleton found in Southeast Asia. The funerary artefacts indicate that Perak Man was highly respected, as he was buried at the centre of the highest cave in Lenggong, and he was the only person buried there. A copy of the original skull was made using computed tomography (CT) and 3D printing. Based on the internal structure of the reconstructed skull, the estimated intracranial volume (ICV) is 1,204.91 mL. The hypothetical face of Perak Man was reconstructed according to established forensic methods. Based on his presumed status, Perak Man was likely a respected person in the group and, perhaps, a shaman and the most knowledgeable person in the group regarding survival, hunting, gathering and other aspects of Palaeolithic daily life.
    Matched MeSH terms: Tomography, X-Ray Computed
  16. Abdullah KA, McEntee MF, Reed WM, Kench PL
    J Appl Clin Med Phys, 2020 Sep;21(9):209-214.
    PMID: 32657493 DOI: 10.1002/acm2.12977
    PURPOSE: The purpose of this study was to investigate the effect of increasing iterative reconstruction (IR) algorithm strength at different tube voltages in coronary computed tomography angiography (CCTA) protocols using a three-dimensional (3D)-printed and Catphan® 500 phantoms.

    METHODS: A 3D-printed cardiac insert and Catphan 500 phantoms were scanned using CCTA protocols at 120 and 100 kVp tube voltages. All CT acquisitions were reconstructed using filtered back projection (FBP) and Adaptive Statistical Iterative Reconstruction (ASIR) algorithm at 40% and 60% strengths. Image quality characteristics such as image noise, signal-noise ratio (SNR), contrast-noise ratio (CNR), high spatial resolution, and low contrast resolution were analyzed.

    RESULTS: There was no significant difference (P > 0.05) between 120 and 100 kVp measures for image noise for FBP vs ASIR 60% (16.6 ± 3.8 vs 16.7 ± 4.8), SNR of ASIR 40% vs ASIR 60% (27.3 ± 5.4 vs 26.4 ± 4.8), and CNR of FBP vs ASIR 40% (31.3 ± 3.9 vs 30.1 ± 4.3), respectively. Based on the Modulation Transfer Function (MTF) analysis, there was a minimal change of image quality for each tube voltage but increases when higher strengths of ASIR were used. The best measure of low contrast detectability was observed at ASIR 60% at 120 kVp.

    CONCLUSIONS: Changing the IR strength has yielded different image quality noise characteristics. In this study, the use of 100 kVp and ASIR 60% yielded comparable image quality noise characteristics to the standard CCTA protocols using 120 kVp of ASIR 40%. A combination of 3D-printed and Catphan® 500 phantoms could be used to perform CT dose optimization protocols.

    Matched MeSH terms: Tomography, X-Ray Computed*
  17. Abdullah KA, McEntee MF, Reed W, Kench PL
    J Med Radiat Sci, 2018 Sep;65(3):175-183.
    PMID: 29707915 DOI: 10.1002/jmrs.279
    INTRODUCTION: An ideal organ-specific insert phantom should be able to simulate the anatomical features with appropriate appearances in the resultant computed tomography (CT) images. This study investigated a 3D printing technology to develop a novel and cost-effective cardiac insert phantom derived from volumetric CT image datasets of anthropomorphic chest phantom.

    METHODS: Cardiac insert volumes were segmented from CT image datasets, derived from an anthropomorphic chest phantom of Lungman N-01 (Kyoto Kagaku, Japan). These segmented datasets were converted to a virtual 3D-isosurface of heart-shaped shell, while two other removable inserts were included using computer-aided design (CAD) software program. This newly designed cardiac insert phantom was later printed by using a fused deposition modelling (FDM) process via a Creatbot DM Plus 3D printer. Then, several selected filling materials, such as contrast media, oil, water and jelly, were loaded into designated spaces in the 3D-printed phantom. The 3D-printed cardiac insert phantom was positioned within the anthropomorphic chest phantom and 30 repeated CT acquisitions performed using a multi-detector scanner at 120-kVp tube potential. Attenuation (Hounsfield Unit, HU) values were measured and compared to the image datasets of real-patient and Catphan® 500 phantom.

    RESULTS: The output of the 3D-printed cardiac insert phantom was a solid acrylic plastic material, which was strong, light in weight and cost-effective. HU values of the filling materials were comparable to the image datasets of real-patient and Catphan® 500 phantom.

    CONCLUSIONS: A novel and cost-effective cardiac insert phantom for anthropomorphic chest phantom was developed using volumetric CT image datasets with a 3D printer. Hence, this suggested the printing methodology could be applied to generate other phantoms for CT imaging studies.

    Matched MeSH terms: Tomography, X-Ray Computed/instrumentation; Tomography, X-Ray Computed/methods*
  18. Abidin ZAZ, Hayati F, Tan GH, Goh EH, Hafidzul J, Zulkifli MZ
    J Coll Physicians Surg Pak, 2018 Mar;28(3):S69-S70.
    PMID: 29482714 DOI: 10.29271/jcpsp.2018.03.S69
    A 46-year gentleman presented with a left-sided lumbar region pain without fever or dysuria. He denied episodes of acute urinary retention. There was a hard mass at the distal urethra with normal laboratory blood tests. Computed tomography urogram revealed a concurrent left renal staghorn calculus and large distal urethral stone. The urethral stone was fragmented via endourologic technique successfully. We report a case of a non-obstructing large urethral calculus in a gentleman with concurrent left renal staghorn calculus and discuss the literature review.
    Matched MeSH terms: Tomography, X-Ray Computed*
  19. Abu Bakar I, Shuaib IL, Mohd Ariff AR, Naing NN, Abdullah JM
    Asian J Surg, 2005 Jan;28(1):1-6.
    PMID: 15691788
    OBJECTIVE: Spontaneous intracranial haemorrhage constitutes 18-40% of all stroke cases. Indications for cerebral angiography to find underlying potentially treatable vascular abnormalities are not clear. This study determined which intracranial haemorrhage patients need cerebral angiography by correlating computed tomography (CT) findings, age and hypertension history with cerebral angiography findings.

    METHODS: A total of 54 patients (8-79 years) with intracranial haemorrhage who underwent both CT examination and six-vessel cerebral angiography were studied over a 2-year period. Cerebral angiography was repeated within 6 weeks if the first angiogram was negative.

    RESULTS: Angiography detected vascular lesions in 50% of cases (aneurysm 38.9% and arteriovenous malformation, AVM, 11.1%). In the aneurysm group, angiographic yield was 34.3% whereas in the AVM group, it was 37.9%. Subarachnoid haemorrhage (SAH) combined with other types of haemorrhage (such as intracerebral haemorrhage, ICH) was not significantly correlated with the likelihood of finding a vascular lesion, both aneurysm and AVM (p = 0.157). Age less than 50 years had significant correlation (p = 0.021) in the AVM group as well as in the aneurysm group (p < 0.001). A history of hypertension was associated with both aneurysm (p = 0.039) and AVM (p = 0.008). No patients with deep intracerebral haematoma had vascular lesions. The presence of an intravascular haemorrhage (IVH) had significant correlation with aneurysm (p = 0.008) but not AVM. There was no significant difference in mean age between patients with and without a vascular lesion (p = 0.134).

    CONCLUSION: Cerebral angiography is justified in patients with ICH accompanied by pure SAH (p = 0.001). Other factors associated with finding a vascular lesion were a history of hypertension and the presence of IVH. Diagnostic cerebral angiography is indicated for patients with ICH and SAH and IVH with a history of hypertension, regardless of age.

    Matched MeSH terms: Tomography, X-Ray Computed
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links