Displaying publications 21 - 40 of 58 in total

Abstract:
Sort:
  1. Petrocelli I, Turillazzi S, Delfino G
    Arthropod Struct Dev, 2014 Sep;43(5):457-68.
    PMID: 24797151 DOI: 10.1016/j.asd.2014.04.007
    In the wasp venom apparatus, the convoluted gland is the tract of the thin secretory unit, i.e. filament, contained in the muscular reservoir. Previous transmission electron microscope investigation on Stenogastrinae disclosed that the free filaments consist of distal and proximal tracts, from/to the venom reservoir, characterized by class 3 and 2 gland patterns, respectively. This study aims to extend the ultrastructural analysis to the convoluted tract, in order to provide a thorough, subcellular representation of the venom gland in these Asian wasps. Our findings showed that the convoluted gland is a continuation of the proximal tract, with secretory cells provided with a peculiar apical invagination, the extracellular cavity, collecting their products. This compartment holds a simple end-apparatus lined by large and ramified microvilli that contribute to the processing of the secretory product. A comparison between previous and present findings reveals a noticeable regionalization of the stenogastrine venom filaments and suggests that the secretory product acquires its ultimate composition in the convoluted tract.
    Matched MeSH terms: X-Ray Microtomography
  2. Kadir MR, Syahrom A, Ochsner A
    Med Biol Eng Comput, 2010 May;48(5):497-505.
    PMID: 20224954 DOI: 10.1007/s11517-010-0593-2
    Human bones can be categorised into one of two types--the compact cortical and the porous cancellous. Whilst the cortical is a solid structure macroscopically, the structure of cancellous bone is highly complex with plate-like and strut-like structures of various sizes and shapes depending on the anatomical site. Reconstructing the actual structure of cancellous bone for defect filling is highly unfeasible. However, the complex structure can be simplified into an idealised structure with similar properties. In this study, two idealised architectures were developed based on morphological indices of cancellous bone: the tetrakaidecahedral and the prismatic. The two architectures were further subdivided into two types of microstructure, the first consists of struts only and the second consists of a combination of plates and struts. The microstructures were transformed into finite element models and displacement boundary condition was applied to all four idealised cancellous models with periodic boundary conditions. Eight unit cells extracted from the actual cancellous bone obtained from micro-computed tomography were also analysed with the same boundary conditions. Young's modulus values were calculated and comparison was made between the idealised and real cancellous structures. Results showed that all models with a combination of plates and struts have higher rigidity compared to the one with struts only. Values of Young's modulus from eight unit cells of cancellous bone varied from 42 to 479 MPa with an average of 234 MPa. The prismatic architecture with plates and rods closely resemble the average stiffness of a unit cell of cancellous bone.
    Matched MeSH terms: X-Ray Microtomography
  3. Md Saad AP, Prakoso AT, Sulong MA, Basri H, Wahjuningrum DA, Syahrom A
    Biomech Model Mechanobiol, 2019 Jun;18(3):797-811.
    PMID: 30607641 DOI: 10.1007/s10237-018-01115-z
    This study employs a computational approach to analyse the impact of morphological changes on the structural properties of biodegradable porous Mg subjected to a dynamic immersion test for its application as a bone scaffold. Porous Mg was immersed in a dynamic immersion test for 24, 48, and 72 h. Twelve specimens were prepared and scanned using micro-CT and then reconstructed into a 3D model for finite element analysis. The structural properties from the numerical simulation were then compared to the experimental values. Correlations between morphological parameters, structural properties, and fracture type were then made. The relative losses were observed to be in agreement with relative mass loss done experimentally. The degradation rates determined using exact (degraded) surface area at particular immersion times were on average 20% higher than the degradation rates obtained using original surface area. The dynamic degradation has significantly impacted the morphological changes of porous Mg in volume fraction, surface area, and trabecular separation, which in turn affects its structural properties and increases the immersion time.
    Matched MeSH terms: X-Ray Microtomography
  4. Le MHT, Noor Hayaty AK, Zaini ZM, Dom SM, Ibrahim N, Radzi ZB
    Korean J Orthod, 2019 Jul;49(4):235-245.
    PMID: 31367578 DOI: 10.4041/kjod.2019.49.4.235
    Objective: This study examined bone microstructure restoration after rapid maxillary expansion (RME) with and without corticotomy over multiple retention periods.

    Methods: Eighteen male Dorper sheep were randomly distributed into three groups (n = 6 each group): group 1, RME with corticotomy on the buccal and palatal sides; group 2, conventional RME treatment; and group 3, no treatment. Post-RME, trabecular bone microstructure and new bone formation were evaluated by using microcomputed tomography (microCT) and histomorphometry after a 4- or 12-week retention period. Intergroup differences in bone quality and bone remodeling were analyzed by using two-way analysis of variance with Bonferroni post-hoc test.

    Results: The bone volume fraction (bone volume [BV]/total volume [TV]) values relative to the control in groups 1 and 2 were 54.40% to 69.88% after the 4-week retention period and returned to approximately 80% after the 12-week retention period. The pooled BV/TV values of the banded teeth in groups 1 and 2 were significantly lower than those of the control after the 4-week retention period (p < 0.05). However, after the 12-week retention period, the pooled BV/TV values in group 2 were significantly lower than those in groups 1 and 3 (p < 0.05). Histomorphological analysis showed that the new bone formation area in group 1 was approximately two to three times of those in group 2 and control.

    Conclusions: Corticotomy significantly enhanced the restoration of bone quality after the retention periods for banded teeth. This benefit might result from the increased new bone formation after corticotomy.

    Matched MeSH terms: X-Ray Microtomography
  5. Ahmed HMA, Versiani MA, De-Deus G, Dummer PMH
    Int Endod J, 2017 Aug;50(8):761-770.
    PMID: 27578418 DOI: 10.1111/iej.12685
    Knowledge of root and root canal morphology is a prerequisite for effective nonsurgical and surgical endodontic treatments. The external and internal morphological features of roots are variable and complex, and several classifications have been proposed to define the various types of canal configurations that occur commonly. More recently, improvements in nondestructive digital image systems, such as cone-beam and micro-computed tomography, as well as the use of magnification in clinical practice, have increased the number of reports on complex root canal anatomy. Importantly, using these newer techniques, it has become apparent that it is not possible to classify many root canal configurations using the existing systems. The purpose of this article is to introduce a new classification system that can be adapted to categorize root and root canal configurations in an accurate, simple and reliable manner that can be used in research, clinical practice and training.
    Matched MeSH terms: X-Ray Microtomography
  6. Athanasios Mantalaris, Alexander Bismarck, Saiful Irwan Zubairi
    Sains Malaysiana, 2015;44:1351-1356.
    Polyhydroxyalkanoates (PHAs) has been investigated for more than eighty years. Ever since then, the scientists are kept on synthesizing and developing new polymers and application to suit human interests nowadays. The resourcefulness of PHAs has made them a good candidates for the study of their potential in a variety of areas from biomedical/medical fields to food, packaging, textile and household material. In medical field (specifically in tissue engineering application), producing a biocompatible 3-D scaffold with adaptable physical properties are essential. However, to the best of our knowledge, scaffolds from PHB and PHBV with thickness greater than 1 mm have not been produced yet. In this work, PHB and PHBV porous 3-D scaffolds with an improved thickness greater than 4 mm was fabricated using conventional method of solvent-casting particulate-leaching (SCPL). A preliminary assessment on the improved thickness 3-D scaffolds was carried out to examine its pore interconnectivity by using non-invasive color staining method. The vertical cross sections image of the stained scaffolds was analyzed by image analyzer software. This technique was considered simple, fast and cost effective method prior to the usage of super accurate analytical instruments (micro-computed tomography). The results showed that over 80% of the pores have been interconnected with the adjacent pores. Moreover, there was a good correlation between the predicted pore interconnectivity and porosity. These results indicated how well a simple technique can do by giving an overview of the internal morphology of a porous 3-D structure material.
    Matched MeSH terms: X-Ray Microtomography
  7. Ruff CB, Sylvester AD, Rahmawati NT, Suriyanto RA, Storm P, Aubert M, et al.
    J Hum Evol, 2022 Nov;172:103252.
    PMID: 36162353 DOI: 10.1016/j.jhevol.2022.103252
    Late Pleistocene hominin postcranial specimens from Southeast Asia are relatively rare. Here we describe and place into temporal and geographic context two partial femora from the site of Trinil, Indonesia, which are dated stratigraphically and via Uranium-series direct dating to ca. 37-32 ka. The specimens, designated Trinil 9 and 10, include most of the diaphysis, with Trinil 9 being much better preserved. Microcomputed tomography is used to determine cross-sectional diaphyseal properties, with an emphasis on midshaft anteroposterior to mediolateral bending rigidity (Ix/Iy), which has been shown to relate to both body shape and activity level in modern humans. The body mass of Trinil 9 is estimated from cortical area and reconstructed length using new equations based on a Pleistocene reference sample. Comparisons are carried out with a large sample of Pleistocene and Holocene East Asian, African, and European/West Asian femora. Our results show that Trinil 9 has a high Ix/Iy ratio, most consistent with a relatively narrow-bodied male from a mobile hunting-gathering population. It has an estimated body mass of 55.4 kg and a stature of 156 cm, which are small relative to Late Pleistocene males worldwide, but larger than the penecontemporaneous Deep Skull femur from Niah Cave, Malaysia, which is very likely female. This suggests the presence of small-bodied active hunter-gatherers in Southeast Asia during the later Late Pleistocene. Trinil 9 also contrasts strongly in morphology with earlier partial femora from Trinil dating to the late Early-early Middle Pleistocene (Femora II-V), and to a lesser extent with the well-known complete Femur I, most likely dating to the terminal Middle-early Late Pleistocene. Temporal changes in morphology among femoral specimens from Trinil parallel those observed in Homo throughout the Old World during the Pleistocene and document these differences within a single site.
    Matched MeSH terms: X-Ray Microtomography
  8. Alyessary AS, Yap AUJ, Othman SA, Rahman MT, Radzi Z
    J Oral Maxillofac Surg, 2018 03;76(3):616-630.
    PMID: 28893543 DOI: 10.1016/j.joms.2017.08.018
    PURPOSE: The present study investigated the effect of piezoelectric sutural ostectomies on accelerated bone-borne sutural expansion.

    MATERIALS AND METHODS: Sixteen male New Zealand white rabbits (20 to 24 weeks old) were randomly divided into 4 experimental groups (n = 4): group 1, conventional rapid sutural expansion; group 2, accelerated sutural expansion; group 3, accelerated sutural expansion with continuous ostectomy; and group 4, accelerated sutural expansion with discontinuous ostectomy. All sutural ostectomies were performed using a piezoelectric instrument (Woodpecker DTE, DS-II, Guangxi, China) before expander application with the rabbits under anesthesia. Modified hyrax expanders were placed across the midsagittal sutures of the rabbits and secured with miniscrew implants located bilaterally in the frontal bone. The hyrax expanders were activated 0.5 mm/day for 12 days (group 1) or with a 2.5-mm initial expansion, followed by 0.5 mm/day for 7 days (groups 2 to 4). After 6 weeks of retention, the bone volume fraction, sutural separation, and new bone formation were evaluated using micro-computed tomography and histomorphometry. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests and Spearman's rho correlation (P 

    Matched MeSH terms: X-Ray Microtomography
  9. Ramli R, Khamis MF, Shuid AN
    PMID: 22952556 DOI: 10.1155/2012/501858
    Recent studies suggested that Eurycoma longifolia, a herbal plant, may have the potential to treat osteoporosis in elderly male. This study aimed to determine the effects of Eurycoma longifolia supplementation on the trabecular bone microarchitecture of orchidectomised rats (androgen-deficient osteoporosis model). Forty-eight-aged (10-12 months old) Sprague Dawley rats were divided into six groups of sham-operated (SHAM), orchidectomised control (ORX), orchidectomised + 7 mg/rat testosterone enanthate (TEN) and orchidectomised + Eurycoma longifolia 30 mg/kg (EL30), orchidectomised + Eurycoma longifolia 60 mg/kg (EL60), orchidectomised + Eurycoma longifolia 90 mg/kg (EL90). Rats were euthanized following six weeks of treatment. The left femora were used to measure the trabecular bone microarchitecture using micro-CT. Orchidectomy significantly decreased connectivity density, trabecular bone volume, and trabecular number compared to the SHAM group. Testosterone replacement reversed all the orchidectomy-induced changes in the micro-CT parameters. EL at 30 and 60 mg/kg rat worsened the trabecular bone connectivity density and trabecular separation parameters of orchidectomised rats. EL at 90 mg/kg rat preserved the bone volume. High dose of EL (90 mg/kg) may have potential in preserving the bone microarchitecture of orchidectomised rats, but lower doses may further worsen the osteoporotic changes.
    Matched MeSH terms: X-Ray Microtomography
  10. Anderson PJ, Yong R, Surman TL, Rajion ZA, Ranjitkar S
    Aust Dent J, 2014 Jun;59 Suppl 1:174-85.
    PMID: 24611727 DOI: 10.1111/adj.12154
    Following the invention of the first computed tomography (CT) scanner in the early 1970s, many innovations in three-dimensional (3D) diagnostic imaging technology have occurred, leading to a wide range of applications in craniofacial clinical practice and research. Three-dimensional image analysis provides superior and more detailed information compared with conventional plain two-dimensional (2D) radiography, with the added benefit of 3D printing for preoperative treatment planning and regenerative therapy. Current state-of-the-art multidetector CT (MDCT), also known as medical CT, has an important role in the diagnosis and management of craniofacial injuries and pathology. Three-dimensional cone beam CT (CBCT), pioneered in the 1990s, is gaining increasing popularity in dental and craniofacial clinical practice because of its faster image acquisition at a lower radiation dose, but sound guidelines are needed to ensure its optimal clinical use. Recent innovations in micro-computed tomography (micro-CT) have revolutionized craniofacial biology research by enabling higher resolution scanning of teeth beyond the capabilities of MDCT and CBCT, presenting new prospects for translational clinical research. Even after four decades of refinement, CT technology continues to advance and broaden the horizons of craniofacial clinical practice and phenomics research.
    Matched MeSH terms: X-Ray Microtomography/methods
  11. Ahmed HMA, Versiani MA, De-Deus G, Dummer PMH
    Int Endod J, 2018 Oct;51(10):1182-1183.
    PMID: 30191599 DOI: 10.1111/iej.12928
    Matched MeSH terms: X-Ray Microtomography/methods
  12. Lau SF, Wolschrijn CF, Hazewinkel HA, Siebelt M, Voorhout G
    Vet J, 2013 Sep;197(3):724-30.
    PMID: 23702281 DOI: 10.1016/j.tvjl.2013.04.002
    Medial coronoid disease (MCD) encompasses lesions of the entire medial coronoid process (MCP), both of the articular cartilage and the subchondral bone. To detect the earliest signs of MCD, radiography and computed tomography were used to monitor the development of MCD in 14 Labrador retrievers, from 6 to 7 weeks of age until euthanasia. The definitive diagnosis of MCD was based on necropsy and micro-computed tomography findings. The frequency of MCD in the dogs studied was 50%. Radiographic findings did not provide evidence of MCD, ulnar subtrochlear sclerosis or blunting of the cranial edge of the MCP. Computed tomography was more sensitive (30.8%) than radiography (0%) in detecting early MCD, with the earliest signs detectable at 14 weeks of age. A combination of the necropsy and micro-computed tomography findings of the MCP showed that MCD was manifested as a lesion of only the subchondral bone in dogs <18 weeks of age. In all dogs (affected and unaffected), there was close contact between the base of the MCP and the proximal radial head in the congruent joints. Computed tomography and micro-computed tomography findings indicated that the lesions of MCD probably originated at the base of the MCP.
    Matched MeSH terms: X-Ray Microtomography/veterinary*
  13. Yunos MA, Hussain SA, Yusoff HM, Abdullah J
    Appl Radiat Isot, 2014 Sep;91:57-61.
    PMID: 24907683 DOI: 10.1016/j.apradiso.2014.05.015
    Radioactive particle tracking (RPT) has emerged as a promising and versatile technique that can provide rich information about a variety of multiphase flow systems. However, RPT is not an off-the-shelf technique, and thus, users must customize RPT for their applications. This paper presents a simple procedure for preparing radioactive tracer particles created via irradiation with neutrons from the TRIGA Mark II research reactor. The present study focuses on the performance evaluation of encapsulated gold and scandium particles for applications as individual radioactive tracer particles using qualitative and quantitative neutron activation analysis (NAA) and an X-ray microcomputed tomography (X-ray Micro-CT) scanner installed at the Malaysian Nuclear Agency.
    Matched MeSH terms: X-Ray Microtomography
  14. Abdul Razak HR, Shaffiq Said Rahmat SM, Md Saad WM
    Quant Imaging Med Surg, 2013 Oct;3(5):256-61.
    PMID: 24273743 DOI: 10.3978/j.issn.2223-4292.2013.10.04
    The study aimed to investigate the effects of different tube potentials and concentrations of iodinated contrast media (CM) on the image enhancement, contrast-to-noise ratio (CNR) and noise in micro-computed tomography (µCT) images. A phantom containing of five polyethylene tube was filled with 2 mL of deionized water and iodinated CM (Omnipaque 300 mgI/mL) at four different concentrations: 5, 10, 15, and 20 mol/L, respectively. The phantom was scanned with a µCT machine (SkyScan 1176) using various tube potentials: 40, 50, 60, 70, 80, and 90 kVp, a fixed tube current; 100 µA, and filtration of 0.2 mm aluminum (Al). The percentage difference of image enhancement, CNR and noise of all images, acquired at different kVps and concentrations, were calculated. The image enhancement, CNR and noise curves with respect to tube potential and concentration were plotted and analysed. The highest image enhancement was found at the lowest tube potential of 40 kVp. At this kVp setting, the percentage difference of image enhancement [Hounsfield Unit (HU) of 20 mol/L iodine concentration over HU of deionized water] was 43%. By increasing the tube potential, it resulted with the reduction of HU, where only 17.5% different were noticed for 90 kVp. Across all iodine concentrations (5-20 M), CNR peaked at 80 kVp and then these values showed a slight decreasing pattern, which might be due insufficient tube current compensation. The percentage difference of image noise obtained at 40 and 90 kVp was 72.4%. Lower tube potential setting results in higher image enhancement (HU) in conjunction with increasing concentration of iodinated CM. Overall, the tube potential increment will substantially improve CNR and reduce image noise.
    Matched MeSH terms: X-Ray Microtomography
  15. Ahmed HMA, Ibrahim N, Mohamad NS, Nambiar P, Muhammad RF, Yusoff M, et al.
    Int Endod J, 2021 Jul;54(7):1056-1082.
    PMID: 33527452 DOI: 10.1111/iej.13486
    Adequate knowledge and accurate characterization of root and canal anatomy is an essential prerequisite for successful root canal treatment and endodontic surgery. Over the years, an ever-increasing body of knowledge related to root and canal anatomy of the human dentition has accumulated. To correct deficiencies in existing systems, a new coding system for classifying root and canal morphology, accessory canals and anomalies has been introduced. In recent years, micro-computed tomography (micro-CT) and cone beam computed tomography (CBCT) have been used extensively to study the details of root and canal anatomy in extracted teeth and within clinical settings. This review aims to discuss the application of the new coding system in studies using micro-CT and CBCT, provide a detailed guide for appropriate characterization of root and canal anatomy and to discuss several controversial issues that may appear as potential limitations for proper characterization of roots and canals.
    Matched MeSH terms: X-Ray Microtomography
  16. Gan SC, Fok ASL, Sedky RA, Sukumaran P, Chew HP
    Dent Mater, 2020 11;36(11):1379-1387.
    PMID: 32907752 DOI: 10.1016/j.dental.2020.08.003
    OBJECTIVE: The aim of this research was to determine the association between sorptivity of water and the state of mineralization in carious enamel of different stages of severity.

    METHODS: As a preliminary work, water droplets of 1.5 μL were placed on the surfaces of hydroxyapatite (HA) discs of different densities. The water droplet profile was dynamically recorded every second over a period of 10 s using a contact angle meter to determine the relationship between sorptivity and density. To measure and calculate sorptivity on enamel surfaces, varnish was painted on the labial surface of 96 extracted caries-free human teeth, leaving two 1.4 ± 0.1 mm diameter circular exposed test sites. The specimens were randomly divided into 6 groups (n = 16) and subjected to 0(G0), 7(G7), 14(G14), 21(G21), 28(G28) and 35(G35) days of pH cycling, respectively. A 0.7 μL water droplet was placed on each exposed site and Optical Coherence Tomography was used to measure its height every 10 seconds for 2 min. Sorptivity was computed by considering sorption equations and Washburn's analysis of capillary kinetics and correction for evaporation was also performed. Micro-Computed Tomography scans of the specimens were obtained and delta Z (ΔZ) is the parameter used to measure mineral loss. ΔZ at 10 μm (ΔZ10) and 50 μm (ΔZ50) from the surface were calculated. One-way ANOVA and Post-hoc Tukey tests were used to compare sorptivity between groups and bivariate correlations were used to analyze the association between sorptivity and ΔZ.

    RESULTS: Sorptivity was found to be inversely and linearly correlated with HA density with R2 value of 0.95. With enamel, there is a general trend of increase in mean sorptivity from G0 to G35, except for a decrease in G21. The same trends were observed for both ΔZ10 and ΔZ50. The decrease in sorptivity in G21 coincided with the presence of a surface hypermineralized layer in G21 samples. Post-hoc Tukey showed significant differences in mean sorptivity between G0 and G14, G0 and G21 as well as G14 and G21. Post-hoc Dunnett's T3 showed significant differences for ΔZ10 between G0 and G14 as well as G14 and G21. Significant correlation between mean sorptivity and ΔZ10 was detected with Pearson correlation coefficient of 0.461. For ΔZ50, post-hoc Tukey showed significant differences between G0 and G14 but no significant difference was detected between G14 and G21. No correlations were detected between mean sorptivity and ΔZ50.

    SIGNIFICANCE: Sorptivity was found to be inversely and linearly correlated with HA density with R2 value of 0.95. With enamel, there is a general trend of increase in mean sorptivity from G0 to G35, except for a decrease in G21. The same trends were observed for both ΔZ10 and ΔZ50. The decrease in sorptivity in G21 coincided with the presence of a surface hypermineralized layer in G21 samples.

    Matched MeSH terms: X-Ray Microtomography
  17. Khairiah Yazid @ Khalid, Roslan Yahya, Nadira Kamarudini, Mohd. Zaid Abdullah, Mohd Ashhar Khalid, Abdul Aziz Mohamed
    MyJurnal
    Detection and analysis of resin is particularly significant since the commercial value of agarwood is related to the quantity of resins that are present. This article explores the potential of a scanning electron microscope in combination with new non-destructive 3D visualization technique, X-ray micro-computed tomography, as imaging tools to visualize micro-structure resin in agarwood. These techniques were used to compare two samples of agarwood chips: high grade and low grade. From the results, it can be concluded that a wood cell filled with resin deposit have a higher attenuation. It can be shown that the combination of scanning electron microscopy and micro-CT can offer high resolution images concerning the localization and structure of resin inside Agarwood. While the second allows the 3D investigation of internal structure of agarwood, the first technique can provide details 2D morphological information. These imaging techniques, although sophisticated can be used for standard development especially in grading of agarwoodlbr commercial activities.
    Matched MeSH terms: X-Ray Microtomography
  18. Mok PL, Leow SN, Koh AE, Mohd Nizam HH, Ding SL, Luu C, et al.
    Int J Mol Sci, 2017 Feb 08;18(2).
    PMID: 28208719 DOI: 10.3390/ijms18020345
    Mesenchymal stem cells are widely used in many pre-clinical and clinical settings. Despite advances in molecular technology; the migration and homing activities of these cells in in vivo systems are not well understood. Labelling mesenchymal stem cells with gold nanoparticles has no cytotoxic effect and may offer suitable indications for stem cell tracking. Here, we report a simple protocol to label mesenchymal stem cells using 80 nm gold nanoparticles. Once the cells and particles were incubated together for 24 h, the labelled products were injected into the rat subretinal layer. Micro-computed tomography was then conducted on the 15th and 30th day post-injection to track the movement of these cells, as visualized by an area of hyperdensity from the coronal section images of the rat head. In addition, we confirmed the cellular uptake of the gold nanoparticles by the mesenchymal stem cells using transmission electron microscopy. As opposed to other methods, the current protocol provides a simple, less labour-intensive and more efficient labelling mechanism for real-time cell tracking. Finally, we discuss the potential manipulations of gold nanoparticles in stem cells for cell replacement and cancer therapy in ocular disorders or diseases.
    Matched MeSH terms: X-Ray Microtomography
  19. Mohd Ariffin S, Dalzell O, Hardiman R, Manton DJ, Parashos P, Rajan S
    Eur Arch Paediatr Dent, 2020 Aug;21(4):519-525.
    PMID: 32100200 DOI: 10.1007/s40368-020-00515-z
    AIM: Successful endodontic treatment of primary teeth requires comprehensive knowledge and understanding of root canal morphology. The purpose of this study was to investigate the root canal configurations of primary maxillary second molars using micro-computed tomography.

    METHODS: Extracted human primary maxillary second molars (n = 57) were scanned using micro-computed tomography and reconstructed to produce three-dimensional models. Each root canal system was analysed qualitatively according to Vertucci's classification.

    RESULTS: 22.8% (n = 13) of the sample presented with the fusion of the disto-buccal and palatal roots; of these, Type V was the most prevalent classification. For teeth with three separate roots (n = 44), the most common root canal type was Type 1 for the palatal canal (100%) and disto-buccal canal (77.3%) and Type V for the mesio-buccal canal (36.4%). Overall, 7% (n = 4) of mesio-buccal canals were 'unclassifiable'.

    CONCLUSION: The root canal systems of primary maxillary second molars were not only complex but had a range of configurations that may contribute to unfavourable clinical outcomes after endodontic treatment.

    Matched MeSH terms: X-Ray Microtomography
  20. Dalzell O, Mohd Ariffin S, Patrick CJ, Hardiman R, Manton DJ, Parashos P, et al.
    Eur Arch Paediatr Dent, 2021 Oct;22(5):911-927.
    PMID: 34146251 DOI: 10.1007/s40368-021-00641-2
    PURPOSE: Pulpectomy may be indicated in restorable primary teeth exhibiting irreversible pulpitis or pulpal necrosis. The purpose of this study was to compare the cleaning and shaping efficacy of NiTi systems (Reciproc® Blue and MTwo®) with manual stainless-steel instrumentation in primary molars using micro-CT analysis.

    METHODS: Fifty-seven maxillary second primary molars were scanned using micro-CT. Teeth with three divergent roots were divided randomly (n = 15) according to instrument type (K file, MTwo®, and Reciproc® Blue). Teeth with root fusion were instrumented manually as a separate group (n = 12). Pre- and post-instrumentation micro-CT images were superimposed, and the instrumentation area (IA) and procedural complications were recorded.

    RESULTS: No statistically significant differences in IA between file systems was observed in the non-fused teeth. The mean IA of fused roots was significantly lower than in the non-fused distobuccal (p = 0.003) and palatal (p  60%) occurred in both non-fused and fused primary teeth with fewer procedural complications observed after manual instrumentation.

    Matched MeSH terms: X-Ray Microtomography
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links