Displaying publications 41 - 60 of 69 in total

Abstract:
Sort:
  1. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*; Heart Valve Prosthesis Implantation/adverse effects*
  2. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
    Matched MeSH terms: Prosthesis Implantation/instrumentation
  3. Khang NC, Zainal AA
    Med J Malaysia, 2016 02;71(1):17-22.
    PMID: 27130738
    BACKGROUND: This is a single institutional review of aortoiliac pseudoaneurysm of various aetiologies managed with endovascular stent graft repair.

    METHODS: From 2009 to 2014, 16 patients had endovascular stent graft inserted for pseudoaneurysm of the thoracic aorta, abdominal aorta and iliac arteries in Hospital Kuala Lumpur. Co-morbidity, causative agents, in-hospital mortality, complications and outcomes were examined.

    RESULTS: The average age was 59.1 years (range 36-77). Comorbidities include hypertension, diabetes mellitus, tuberculosis, prior infection and previous open aneurysmal repair. All patients had raised WBC (>10.0x10(9) /L), ESR or Creactive protein on admission while 50% of patients had fever. Blood cultures were positive in 4 patients. All patients were given antibiotics. Only one in-hospital mortality was noted at day-47 post-procedure. Two patients died of aortoenteric fistula at district hospital eight and 16 months later. One patient died of chronic graft infection two years later. One died of unrelated cause. One patient developed type IB endoleak from internal iliac artery two years later and surgical ligation was performed. The average follow up was 15.8 months.

    CONCLUSION: Endovascular stent graft repair for pseudoaneurysm is a viable option compared to open surgery. It is less invasive, has lower operative morbidity and fair outcomes. However, some cases may be due to inflammatory aortitis instead of infective pseudoaneurysm, given the frequent culture-negative results. In order to obtain high yield of bacteria culture for infected pseudoaneurysm, open repair with tissue culture is still the main mode of treatment especially for patients with low comorbidity.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  4. Aggarwal H, Kumar P, Eachempati P, Alvi HA
    J Prosthodont, 2016 Dec;25(8):687-693.
    PMID: 26447725 DOI: 10.1111/jopr.12369
    Enucleation is the removal of the entire globe of the eye and a portion of the optic nerve, while evisceration involves the removal of the contents of the globe leaving the sclera, extraocular muscles, and optic nerve. Following enucleation or evisceration, intraorbital implants are routinely placed to enhance the prosthetic outcome in addition to restoring the lost orbital volume. Current practice employs intraorbital implants made of nonporous silicone, hydroxyapatite, or porous polyethylene. Intraorbital implant selection and placement, being a highly demanding procedure in terms of knowledge, skill, and expertise, may be associated with a multiplicity of technical and surgical errors. Complications are usually minimal with these implants, but they do occur. The literature reveals many articles related to intraorbital implants, their benefits, and complications; however, the literature regarding the effect of various intraorbital implant situations on the subsequent prosthetic rehabilitation is markedly scarce. Moreover, the need for interdisciplinary surgical and prosthetic interventions required for successful rehabilitation in cases of compromised implant situations has been underemphasized. Hence, this review aimed to evaluate the effect of different intraorbital implant situations on ocular rehabilitation and the required interdisciplinary surgical and prosthetic treatment approach for rehabilitation of enucleated/eviscerated sockets with compromised implant situations, to provide a critical appraisal, and to present a simplified management strategy.
    Matched MeSH terms: Prosthesis Implantation*
  5. Patil PG, Nimbalkar-Patil S
    J Indian Prosthodont Soc, 2017 2 22;17(1):84-88.
    PMID: 28216851 DOI: 10.4103/0972-4052.176538
    INTRODUCTION: Maxillary obturator prosthesis is more frequent treatment modality than surgical reconstruction for maxillectomy in patients suffering from oral cancer. The obturators often become heavy and hence are hollowed out in the defect portion to reduce its weight as a standard practice.

    MATERIALS AND METHODS: The processing technique described the incorporation of the preshaped "wax-bolus" during packing procedure of the Obturtor prosthesis and eliminated later by melting it once the curing procedure is completed.

    RESULTS: This article is a single step procedure resulting into the closed-hollow obturator as single unit with uniform wall thickness around the hollow space ensuring the least possible weight of the hollow obturator.

    CONCLUSION: This processing technique achieves predictable internal dimension of the hollow space providing uniform wall thickness of the obturator.

    Matched MeSH terms: Prosthesis Implantation
  6. Jamayet NB, Kirangi JK, Husein A, Alam MK
    Eur J Dent, 2017 4 25;11(1):130-134.
    PMID: 28435380 DOI: 10.4103/1305-7456.202636
    Enucleation and evisceration are the most common surgical procedures that are performed to manage tumor, trauma, and infection. Given the consequences of surgical intervention, the conditions of the remaining eye socket may affect future prosthetic rehabilitation. A custom-made ocular prosthesis can be used to help restore the esthetics and functional defects and to improve the quality of life of patients with such conditions. An assessment must be performed on the prosthetic outcome before rehabilitation. The etiology of defect, type of surgery, condition of the remaining socket, and patient's age should all be considered. This report discusses three different etiological eye defects that have undergone enucleation and evisceration and describes the factors that have a significant role in the esthetic and functional outcome of the prosthesis. This report should serve as a helpful aid for maxillofacial prosthodontists to understand the primary objective of rehabilitating each eye defect and to meet patient expectations.
    Matched MeSH terms: Prosthesis Implantation
  7. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*; Heart Valve Prosthesis Implantation/methods
  8. Phang ZH, Miskon MFB, Ibrahim SB
    J Med Case Rep, 2018 Jul 18;12(1):211.
    PMID: 30016981 DOI: 10.1186/s13256-018-1751-7
    BACKGROUND: Blunt trauma causing brachial artery injury in a young patient is very rare. Cases of brachial artery injury may be associated with closed elbow dislocation or instability. Elbow dislocation may not be evident clinically and radiologically on initial presentation.

    CASE PRESENTATION: This is a case of a 37-year-old, right-hand dominant, Malay man who fell approximately 6 meters from a rambutan tree and his left arm hit the tree trunk on his way down. He was an active tobacco smoker with a 20 pack year smoking history. On clinical examination, Doppler signals over his radial and ulnar arteries were poor. He proceeded with emergency computed tomography angiogram of his left upper limb which showed non-opacification of contrast at the distal left brachial artery just before the bifurcation of the left brachial artery at his left elbow joint. Radiographs and computed tomography scan also showed undisplaced fracture of left lateral epicondyle and radial head with no evidence of elbow dislocation. He subsequently underwent left brachial to brachial artery bypass which was done using reversed saphenous vein graft and recovered well. His fractures were treated using 90 degree long posterior splint for 2 weeks and he was then allowed early range of motion of the left elbow. This patient developed left elbow dislocation 6 weeks postoperatively. Closed manipulative reduction of his left elbow resulted in incomplete reduction. The functional outcome of his left elbow was limited with a range of motion of left elbow of 0-45 degrees. However, he was not keen for surgery to stabilize his elbow joint during his last follow-up 6 months post injury.

    CONCLUSIONS: This is an uncommon case of brachial artery injury in a civilian caused by blunt trauma associated with occult elbow instability/dislocation and minor fractures around the elbow joint. The treatment of brachial artery injury with clinical evidence of distal ischemia is surgical revascularization. The possibility of elbow instability and dislocation need to be considered in all cases of brachial artery injury because early radiographs and computed tomography scans may be normal. Short-term posterior splint immobilization is not sufficient to prevent recurrent dislocations.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  9. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
  10. Krishna Moorthy PS, Saat SA, Sakijan AS
    Med J Malaysia, 2019 02;74(1):94-96.
    PMID: 30846673
    This is a case report of single-stage total thoracic aortic repair by the frozen elephant trunk technique for a 75-yearold female with a complex aortic pathology of mega-aorta extending from the ascending aorta to the descending aorta. We used a Thora flex™ Hybrid device, a frozen elephant trunk device with four branched grafts and the distal stent graft. The distal stent graft was inserted into the downstream descending aorta via an aortic arch and positioned 15 cm beyond the left subclavian artery after total arch replacement had been performed using a four-branch graft. The postoperative course was unremarkable with no complications. A post procedural computed tomography scan demonstrated complete exclusion of the descending thoracic aneurysm without endoleak. Therefore, fixing the whole mega-aorta in a single stage using the frozen elephant trunk was effective and safe.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods
  11. Krishna Moorthy PS, Sivalingam S, Dillon J, Kong PK, Yakub MA
    Interact Cardiovasc Thorac Surg, 2019 02 01;28(2):191-198.
    PMID: 30085022 DOI: 10.1093/icvts/ivy234
    OBJECTIVES: Contemporary experience in mitral valve (MV) repair for children with rheumatic heart disease (RHD) is limited, despite the potential advantages of repair over replacement. We reviewed our long-term outcomes of rheumatic MV repair and compared them with the outcomes of MV replacement in children with RHD.

    METHODS: This study is a review of 419 children (≤18 years) with RHD who underwent primary isolated MV surgery between 1992 and 2015, which comprised MV repair (336 patients; 80.2%) and MV replacement (83 patients; 19.8%). The replacement group included mechanical MV replacements (MMVRs) (n = 69 patients; 16.5%) and bioprosthetic MV replacements (n = 14 patients; 3.3%). The mean age with standard deviation at the time of operation was 12.5 ± 3.5 (2-18) years. Mitral regurgitation (MR) was predominant in 390 (93.1%) patients, and 341 (81.4%) patients showed ≥3+ MR. The modified Carpentier reconstructive techniques were used for MV repair.

    RESULTS: Overall early mortality was 1.7% (7 patients). The mean follow-up was 5.6 years (range 0-22.3 years; 94.7% complete). Survival of patients who underwent repair was 93.9% both at 10 and 20 years, which was superior than that of replacement (P 

    Matched MeSH terms: Heart Valve Prosthesis Implantation/methods*
  12. El-Chami MF, Clementy N, Garweg C, Omar R, Duray GZ, Gornick CC, et al.
    JACC Clin Electrophysiol, 2019 02;5(2):162-170.
    PMID: 30784685 DOI: 10.1016/j.jacep.2018.12.008
    OBJECTIVES: This study sought to report periprocedural outcomes and intermediate-term follow-up of hemodialysis patients undergoing Micra implantation.

    BACKGROUND: Leadless pacemakers may be preferred in patients with limited vascular access and high-infection risk, such as patients on hemodialysis.

    METHODS: Patients on hemodialysis at the time of Micra implantation attempt (n = 201 of 2,819; 7%) from the Micra Transcatheter Pacing Study investigational device exemption trial, Micra Transcatheter Pacing System Continued Access Study Protocol, and Micra Transcatheter Pacing System Post-Approval Registry were included in the analysis. Baseline characteristics, periprocedural outcomes, and intermediate-term follow-up were summarized.

    RESULTS: Patients on hemodialysis at the time of Micra implantation attempt were on average 70.5 ± 13.5 years of age and 59.2% were male. The dialysis patients commonly had hypertension (80%), diabetes (61%), coronary artery disease (39%), and congestive heart failure (27%), and 72% had a condition that the implanting physician felt precluded the use of a transvenous pacemaker. Micra was successfully implanted in 197 patients (98.0%). Reasons for unsuccessful implantation included inadequate thresholds (n = 2) and pericardial effusion (n = 2). The median implantation time was 27 min (interquartile range: 20 to 39 min). There were 3 procedure-related deaths: 1 due to metabolic acidosis following a prolonged procedure duration in a patient undergoing concomitant atrioventricular nodal ablation and 2 deaths occurred in patients who needed surgical repair after perforation. Average follow-up was 6.2 months (range 0 to 26.7 months). No patients had a device-related infection or required device removal because of bacteremia.

    CONCLUSIONS: Leadless pacemakers represent an effective pacing option in this challenging patient population on chronic hemodialysis. The risk of infection appears low with an acceptable safety profile. (Micra Transcatheter Pacing Study; NCT02004873; Micra Transcatheter Pacing System Continued Access Study Protocol; NCT02488681; Micra Transcatheter Pacing System Post-Approval Registry; NCT02536118).

    Matched MeSH terms: Prosthesis Implantation/adverse effects; Prosthesis Implantation/instrumentation; Prosthesis Implantation/mortality; Prosthesis Implantation/statistics & numerical data
  13. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

    Matched MeSH terms: Prosthesis Implantation/methods*
  14. Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, et al.
    Eur J Pharm Biopharm, 2019 Jun;139:272-278.
    PMID: 31004790 DOI: 10.1016/j.ejpb.2019.04.012
    OBJECTIVE: Vascular prostheses for small caliber bypass grafts in cardiac and vascular diseases or for access surgery are still missing. Poly (Ɛ-caprolactone) (PCL) has been previously investigated by our group and showed good biocompatibility and mechanical properties in vitro and rapid endothelialisation, cellular infiltration and vascularisation in vivo yielding optimal patency in the abdominal aortic position. The aim of the present study is to evaluate our PCL graft in the carotid position and to compare its outcome to the grafts implanted in the abdominal aortic position.

    METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.

    RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.

    CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation; Blood Vessel Prosthesis Implantation/methods*
  15. Low HL, Ismail MNBM, Taqvi A, Deeb J, Fuller C, Misbahuddin A
    Clin Neurol Neurosurg, 2019 Oct;185:105466.
    PMID: 31466022 DOI: 10.1016/j.clineuro.2019.105466
    OBJECTIVE: To compare posterior subthalamic area deep brain stimulation (PSA-DBS) performed in the conventional manner against diffusion tensor imaging and tractography (DTIT)-guided lead implantation into the dentatorubrothalamic tract (DRTT).

    PATIENTS AND METHODS: Double-blind, randomised study involving 34 patients with either tremor-dominant Parkinson's disease or essential tremor. Patients were randomised to Group A (DBS leads inserted using conventional landmarks) or Group B (leads guided into the DRTT using DTIT). Tremor (Fahn-Tolosa-Marin) and quality-of-life (PDQ-39) scores were evaluated 0-, 6-, 12-, 36- and 60-months after surgery.

    RESULTS: PSA-DBS resulted in marked tremor reduction in both groups. However, Group B patients had significantly better arm tremor control (especially control of intention tremor), increased mobility and activities of daily living, reduced social stigma and need for social support as well as lower stimulation amplitudes and pulse widths compared to Group A patients. The better outcomes were sustained for up to 60-months from surgery. The active contacts of Group B patients were consistently closer to the centre of the DRTT than in Group A. Speech problems were more common in Group A patients.

    CONCLUSION: DTIT-guided lead placement results in better and more stable tremor control and fewer adverse effects compared to lead placement in the conventional manner. This is because DTIT-guidance allows closer and more consistent placement of leads to the centre of the DRTT than conventional methods.

    Matched MeSH terms: Prosthesis Implantation/methods*
  16. Chendran P, Seng Fai T, Wan Abdul Halim WH, Md Din N
    J Glaucoma, 2019 10;28(10):e162-e164.
    PMID: 31368915 DOI: 10.1097/IJG.0000000000001334
    Ocular pyogenic granuloma is a benign tumor seen after ocular insult secondary to ocular surgeries, trauma or infection. Although benign, intervention is sometimes necessary. Previous authors have reported pyogenic granuloma formation following oculoplastic surgeries. We report a pyogenic granuloma after an Ahmed glaucoma valve implantation. A 65-year-old gentleman presented with right eye redness associated with pain and swelling ~2 months after Ahmed glaucoma valve implantation. Examination found a sessile growth on the tube extruding puss with signs of endophthalmitis. The glaucoma drainage device was explanted and culture results grew Staphylococcus aureus. This article discusses the formation of pyogenic granuloma on a glaucoma drainage device and its management.
    Matched MeSH terms: Prosthesis Implantation
  17. Inn FX, Ahmed N, Hou LG, Abidin ZAZ, Yi LL, Zainuddin ZM
    Int Urol Nephrol, 2019 Nov;51(11):1949-1953.
    PMID: 31441009 DOI: 10.1007/s11255-019-02262-7
    PURPOSE: The internal drainage provided by a ureteral stent helps with the relief and prevention of ureteral obstruction. By definition, correct stent placement is one with a complete loop in both the renal pelvis and bladder. This prevents stent migration proximally or distally despite urinary flow, patient movement, and ureteral peristalsis.

    METHODS: We performed a comparative prospective cross-sectional study assessing the impact of intravesical stent position on the quality of life in 46 patients with a ureteral stent. This is done using the Ureteral Stent Symptom Questionnaire (USSQ).

    RESULTS: 52.5% of patients had an ipsilateral positioned intravesical stent, while the remaining had their stent positioned contralaterally. Intravesical stent position significantly influenced the quality of life. The USSQ score was worse for the contralateral group. Subscore analysis found that urinary symptoms and body pain index contribute significantly to the morbidity. Majority of patients in the ipsilateral group reported no discomfort as compared to the contralateral group.

    CONCLUSIONS: To the best of our knowledge, this is the first study assessing the impact of intravesical stent position on the quality of life in the Asian population. Intravesical stent position has a significant influence on patient's morbidity and quality of life in particular towards their urinary irritative symptoms and body pain. It is imperative to ensure correct distal placement of ureteric stent that does not cross the midline to the contralateral site. We believe that the USSQ should be used in daily clinical practice in assessing the symptoms related to indwelling ureteric stents.

    Matched MeSH terms: Prosthesis Implantation
  18. Krackhardt F, Kočka V, Waliszewski M, Toušek P, Janek B, Trenčan M, et al.
    Medicine (Baltimore), 2020 Feb;99(8):e19119.
    PMID: 32080086 DOI: 10.1097/MD.0000000000019119
    Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods
  19. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*
  20. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*