Displaying publications 41 - 60 of 340 in total

Abstract:
Sort:
  1. Avin FA, Subha B, Tan YS, Braukmann TWA, Vikineswary S, Hebert PDN
    Ecol Evol, 2017 09;7(17):6972-6980.
    PMID: 28904776 DOI: 10.1002/ece3.3049
    DNA barcoding involves the use of one or more short, standardized DNA fragments for the rapid identification of species. A 648-bp segment near the 5' terminus of the mitochondrial cytochrome c oxidase subunit I (COI) gene has been adopted as the universal DNA barcode for members of the animal kingdom, but its utility in mushrooms is complicated by the frequent occurrence of large introns. As a consequence, ITS has been adopted as the standard DNA barcode marker for mushrooms despite several shortcomings. This study employed newly designed primers coupled with cDNA analysis to examine COI sequence diversity in six species of Pleurotus and compared these results with those for ITS. The ability of the COI gene to discriminate six species of Pleurotus, the commonly cultivated oyster mushroom, was examined by analysis of cDNA. The amplification success, sequence variation within and among species, and the ability to design effective primers was tested. We compared ITS sequences to their COI cDNA counterparts for all isolates. ITS discriminated between all six species, but some sequence results were uninterpretable, because of length variation among ITS copies. By comparison, a complete COI sequences were recovered from all but three individuals of Pleurotus giganteus where only the 5' region was obtained. The COI sequences permitted the resolution of all species when partial data was excluded for P. giganteus. Our results suggest that COI can be a useful barcode marker for mushrooms when cDNA analysis is adopted, permitting identifications in cases where ITS cannot be recovered or where it offers higher resolution when fresh tissue is. The suitability of this approach remains to be confirmed for other mushrooms.
    Matched MeSH terms: Reference Standards
  2. Awais M, Ghayvat H, Krishnan Pandarathodiyil A, Nabillah Ghani WM, Ramanathan A, Pandya S, et al.
    Sensors (Basel), 2020 Oct 12;20(20).
    PMID: 33053886 DOI: 10.3390/s20205780
    Oral mucosal lesions (OML) and oral potentially malignant disorders (OPMDs) have been identified as having the potential to transform into oral squamous cell carcinoma (OSCC). This research focuses on the human-in-the-loop-system named Healthcare Professionals in the Loop (HPIL) to support diagnosis through an advanced machine learning procedure. HPIL is a novel system approach based on the textural pattern of OML and OPMDs (anomalous regions) to differentiate them from standard regions of the oral cavity by using autofluorescence imaging. An innovative method based on pre-processing, e.g., the Deriche-Canny edge detector and circular Hough transform (CHT); a post-processing textural analysis approach using the gray-level co-occurrence matrix (GLCM); and a feature selection algorithm (linear discriminant analysis (LDA)), followed by k-nearest neighbor (KNN) to classify OPMDs and the standard region, is proposed in this paper. The accuracy, sensitivity, and specificity in differentiating between standard and anomalous regions of the oral cavity are 83%, 85%, and 84%, respectively. The performance evaluation was plotted through the receiver operating characteristics of periodontist diagnosis with the HPIL system and without the system. This method of classifying OML and OPMD areas may help the dental specialist to identify anomalous regions for performing their biopsies more efficiently to predict the histological diagnosis of epithelial dysplasia.
    Matched MeSH terms: Reference Standards
  3. Awosolu OB, Yahaya ZS, Farah Haziqah MT, Simon-Oke IA, Fakunle C
    Heliyon, 2021 Jan;7(1):e05975.
    PMID: 33521357 DOI: 10.1016/j.heliyon.2021.e05975
    Background: Malaria is a severe global public health challenge that causes significant morbidity and mortality worldwide, particularly in sub-Saharan Africa. This study was designed to determine the prevalence, parasite density, and risk factors associated with malaria infection transmission among residents of two urban communities of Ibadan, southwestern Nigeria.

    Materials and methods: A cross-sectional hospital-based study was carried out on 300 participants. Blood samples were obtained. Thick and thin blood films were prepared and viewed using the standard parasitological technique of microscopy. Moreover, data on sociodemographic and environmental variables were obtained using a pre-tested standard questionnaire.

    Results: Of the 300 participants examined, a total of 165 (55.0%) were found positive for Plasmodium falciparum with a mean (S.D) parasite density of 1814.70 (1829.117) parasite/μL of blood. The prevalence and parasite density of malaria infection vary significantly (P < 0.05) with age group. Children <5 years old were more likely to have malaria infection and high parasite densities than adults (p < 0.05). Similarly, in relation to gender, males significantly (P < 0.05) had a higher prevalence (60.2%) and mean (S.D) parasite density of malaria infection [2157.73 (1659.570) parasite/μL of blood] compared to females. Additionally, those without formal education had the highest prevalence (73.0%) and mean (S.D) parasite density of infection [2626.96 (2442.195) parasite/μL of blood]. The bivariate logistic regression analysis shows that age group 6-10 (Crude Odds Ratio, COR 0.066, 95% CI: 0.007-0.635), presence of streams/rivers (COR 0.225, 95% CI: 0.103-0.492), distance from streams/rivers within ≤1 km (COR 0.283, 95% CI: 0.122-0.654) and travel to rural area (COR 4.689, 95% CI: 2.430-9.049) were the significant risk factors.

    Conclusions: Malaria infection is prevalent in the study area and was greatly influenced by traveling activities from the rural areas to urban centers and vice versa. Multifaceted and integrated control strategy should be adopted. Health education on mosquito prevention and chemoprophylaxis before and during travel to rural areas are essential.

    Matched MeSH terms: Reference Standards
  4. Azhari NR, Yahaya N, Mohd Suah FBM, Prabu S, Yih Hui B, Shahriman MS, et al.
    Chirality, 2021 01;33(1):37-50.
    PMID: 33197086 DOI: 10.1002/chir.23285
    A chiral separation method coupled with capillary electrophoresis (CE) analysis for ketoconazole and miconazole enantiomers using chiral selectors such as β-cyclodextrin (β-CD) and hydroxypropyl-β-CD (HP-β-CD) was developed in this study, which included the optimisation, validation and application of the method on the antifungal cream samples. The formation of inclusion complex between the hosts (β-CD and HP-β-CD) and guests (ketoconazole and miconazole) were compared and analysed using ultraviolet-visible spectrophotometry, nuclear magnetic resonance (NMR) spectroscopy and molecular docking methods. Results from the study showed that in a concentration that ranged between 0.25 and 50 mg L-1 , the linear calibration curves of each enantiomer had a high coefficient of regression (R2 > 0.999), low limit of detection (0.075 mg L-1 ) and low limit of quantification (0.25 mg L-1 ). The relative standard deviation (RSD) of the intraday and interday analyses ranged from 0.79% to 8.01% and 3.30% to 11.43%, respectively, while the recoveries ranged from 82.0% to 105.7% (RSD < 7%, n = 3). The most probable structure of the inclusion complexes was proposed based on the findings from the molecular docking studies conducted using the PatchDock server.
    Matched MeSH terms: Reference Standards
  5. Azilawati MI, Dzulkifly MH, Jamilah B, Shuhaimi M, Amin I
    J Pharm Biomed Anal, 2016 Sep 10;129:389-397.
    PMID: 27454091 DOI: 10.1016/j.jpba.2016.07.012
    A detailed procedure for estimating uncertainty according to the Laboratory of Government Chemists/Valid Analytical Measurement (LGC/VAM) protocol for determination of 18 amino acids in gelatin is proposed. The expanded uncertainty was estimated using mainly the method validation data (precision and trueness). Other sources of uncertainties were contributed by components in standard preparation measurements. The method scope covered a single matrix (gelatin) under a wide range of analyte concentrations. The uncertainty of method precision, μ(P) was 0.0237-0.1128pmolμl(-1) in which hydroxyproline and histidine represented the lowest and highest values of uncertainties, respectively. Proline and phenylalanine represented the lowest and highest uncertainties value for method recovery, μ(R) that was estimated within 0.0064-0.0995pmolμl(-1). The uncertainties from other sources, μ(Std) were 0.0325, 0.0428 and 0.0413pmolμl(-1) that were contributed by hydroxyproline, other amino acids and cystine, respectively. Hydroxyproline and phenylalanine represented the lowest and highest values of expanded uncertainty, U(y) that were determined at 0.0949 and 0.2473pmolμl(-1), respectively. The data were accurately defined and fulfill the technical requirements of ISO 17025:2005.
    Matched MeSH terms: Reference Standards
  6. Azlina Yahya, Osama Abdul Nasir
    Q Bulletin, 2019;1(28):36-44.
    MyJurnal
    Wastage due to unnecessary laboratory test requests is a major problem in government hospitals because they have cost implications. Although screening of infectious marker tests such as Human Immunodeficiency Virus (HIV), Hepatitis B surface Antigen (HBsAg), Hepatitis B antibody (AHBS) and Hepatitis C Virus (HCV)) before testing have been put in place, inappropriate tests were still being carried out in the Serology laboratory, which resulted in wasted human resources and reagents, increased workload and increased maintenance costs. Based on the verification studies using the Laboratory Information System (LIS), we observed only 70% of the tests followed the ordering guidelines or test specifications. Thus, we aim to increase the standard to more than 95% of the infectious marker test requests which were appropriate according to a few guidelines.
    A cross-sectional study was conducted for all infectious marker tests received at Serology Laboratory from January 2015 to June 2016 to verify the problem. A workplace audit and questionnaire survey on the staff were carried out to gain more information. Low level of knowledge, unavailability of standardised guidelines for quick and easy reference, lack of staff and inefficient work processes were among the main contributing factors. Empowering new staff to screen specimens, developing simple and informative screening guidelines, providing adequate trays and refrigerators for screening purposes and strengthening and developing a more effective process of care were the strategies taken during this study.
    The appropriate tests carried out from July to September 2015, October to December 2015, January to March 2016 and April to June 2016 were 99%, 98.80%, 99.50%, 98.90% respectively. During the same period, 711, 411, 710 and 768 tests were rejected. We monitored the performance and managed to achieve 100% appropriate testing for the period of July 2016 to June 2018 and an estimation of MYR 73,437.50 cost saving was achieve
    Matched MeSH terms: Reference Standards
  7. Azmi N, Kamarudin LM, Zakaria A, Ndzi DL, Rahiman MHF, Zakaria SMMS, et al.
    Sensors (Basel), 2021 Mar 08;21(5).
    PMID: 33800174 DOI: 10.3390/s21051875
    Seasonal crops require reliable storage conditions to protect the yield once harvested. For long term storage, controlling the moisture content level in grains is challenging because existing moisture measuring techniques are time-consuming and laborious as measurements are carried out manually. The measurements are carried out using a sample and moisture may be unevenly distributed inside the silo/bin. Numerous studies have been conducted to measure the moisture content in grains utilising dielectric properties. To the best of authors' knowledge, the utilisation of low-cost wireless technology operating in the 2.4 GHz and 915 MHz ISM bands such as Wireless Sensor Network (WSN) and Radio Frequency Identification (RFID) have not been widely investigated. This study focuses on the characterisation of 2.4 GHz Radio Frequency (RF) transceivers using ZigBee Standard and 868 to 915 MHz UHF RFID transceiver for moisture content classification and prediction using Artificial Neural Network (ANN) models. The Received Signal Strength Indicator (RSSI) from the wireless transceivers is used for moisture content prediction in rice. Four samples (2 kg of rice each) were conditioned to 10%, 15%, 20%, and 25% moisture contents. The RSSI from both systems were obtained and processed. The processed data is used as input to different ANNs models such as Support Vector Machine (SVM), K-Nearest Neighbour (KNN), Random Forest, and Multi-layer Perceptron (MLP). The results show that the Random Forest method with one input feature (RSSI_WSN) provides the highest accuracy of 87% compared to the other four models. All models show more than 98% accuracy when two input features (RSSI_WSN and RSSI_TAG2) are used. Hence, Random Forest is a reliable model that can be used to predict the moisture content level in rice as it gives a high accuracy even when only one input feature is used.
    Matched MeSH terms: Reference Standards
  8. Babatunde O, Hameed S, Salar U, Chigurupati S, Wadood A, Rehman AU, et al.
    Mol Divers, 2021 Mar 01.
    PMID: 33650031 DOI: 10.1007/s11030-021-10196-5
    A variety of dihydroquinazolin-4(1H)-one derivatives (1-37) were synthesized via "one-pot" three-component reaction scheme by treating aniline and different aromatic aldehydes with isatoic anhydride in the presence of acetic acid. Chemical structures of compounds were deduced by different spectroscopic techniques including EI-MS, HREI-MS, 1H-, and 13C-NMR. Compounds were subjected to α-amylase and α-glucosidase inhibitory activities. A number of derivatives exhibited significant to moderate inhibition potential against α-amylase (IC50 = 23.33 ± 0.02-88.65 ± 0.23 μM) and α-glucosidase (IC50 = 25.01 ± 0.12-89.99 ± 0.09 μM) enzymes, respectively. Results were compared with the standard acarbose (IC50 = 17.08 ± 0.07 μM for α-amylase and IC50 = 17.67 ± 0.09 μM for α-glucosidase). Structure-activity relationship (SAR) was rationalized by analyzing the substituents effects on inhibitory potential. Kinetic studies were implemented to find the mode of inhibition by compounds which revealed competitive inhibition for α-amylase and non-competitive inhibition for α-glucosidase. However, in silico study identified several important binding interactions of ligands (synthetic analogues) with the active site of both enzymes.
    Matched MeSH terms: Reference Standards
  9. Baig MA, Swamy KB
    Indian J Pathol Microbiol, 2021 1 13;64(1):123-127.
    PMID: 33433421 DOI: 10.4103/IJPM.IJPM_900_19
    Background: In the laboratory, factor VIII can be measured by three different methodologies, such as one-stage clotting assay, two-stage clotting assay, and chromogenic assay. These assays differ in ease of use, variety of reagents available, sensitivity to mild hemophilia A, and interference from lupus anticoagulants (LACs). Certain factor VIII gene mutations can cause discrepancy in results between one-stage activated partial thromboplastin time (APTT) and chromogenic assays.

    Materials and Methods: The coagulometer for factor VIII assay is Sysmex CS-5100. All data were expressed as mean ± standard deviation (SD).

    Results: A total of 135 cases were studied. Of these, 100 cases were of mild hemophilia A diagnosed by molecular genetics and, 15 cases were positive for LAC, which were confirmed by dilute Russell Viper venom test. Clot-based one-stage APTT assay showed 65% sensitivity and 80% specificity in diagnosing mild hemophilia A cases and out of 15 LAC cases, it showed false positivity in five cases. Chromogenic assay showed 85% sensitivity and 90% specificity in diagnosing mild hemophilia cases and was 100% specific in excluding LAC cases.

    Conclusions: One-stage APTT assay is the most commonly used test for determining factor VIII levels but chromogenic assay are considered as the gold standard and recommended as the reference method by European Pharmacopoeia and ISTH subcommittee. Mild hemophilia A patients with missense mutations show discrepancy between the one-stage clot-based APTT assay and chromogenic assays for determination of factor VIII level and this can lead to misdiagnosis or misclassification of mild hemophilia A. Therefore, it is recommended that both the assays should be used in the evaluation of mild hemophilia cases.

    Matched MeSH terms: Reference Standards
  10. Bakar, J., Abdul Kadir, N. S., Ahmad Mazlan, A. S., Ismail Fitry, M. R.
    MyJurnal
    The quality change of fish sausage (keropok lekor) coated in sago starch-gelatine coating with
    papaya seed extract (PSE) during chill storage (7°C) was determined. During storage, pH,
    thiobarbituric acid value (TBA), colour, moisture, and the total plate count were evaluated. pH
    of samples significantly dropped (p < 0.05) during storage, and the highest decrease was in
    control sample. The moisture content in control sample had an increasing trend while that of
    samples with 5 and 7% PSE coatings significantly decreased, and only a slight change for
    samples with 0% PSE coating. All samples had significant increase in their TBA values during
    storage. The presence of the coating provided a positive effect on the colour of the fish sausages since no significant colour changes were observed during storage. TPC of control and
    coated sausage in 0, 5, and 7% PSE exceeded the recommended microbial standard after 2, 6,
    8, and 4 d of storage, respectively. Overall, coating with 5% of PSE was the most effective in
    retarding the quality deterioration of the fish sausages.
    Matched MeSH terms: Reference Standards
  11. Bergstresser SM, Ghias K, Lane S, Lau WM, Hwang ISS, Ngan OMY, et al.
    Asian Bioeth Rev, 2020 Jun;12(2):173-194.
    PMID: 33717336 DOI: 10.1007/s41649-020-00120-8
    Contemporary bioethics education has been developed predominately within Euro-American contexts, and now, other global regions are increasingly joining the field, leading to a richer global understanding. Nevertheless, many standard bioethics curriculum materials retain a narrow geographic focus. The purpose of this article is to use local cases from the Asia-Pacific region as examples for exploring questions such as 'what makes a case or example truly local, and why?', 'what topics have we found to be best explained through local cases or examples?', and 'how does one identify a relevant local case?' Furthermore, we consider the global application of local cases to help extend the possible scope of the discussion, opening new avenues for the development of practical bioethics educational materials. We begin with a background description and discussion of why local cases enhance bioethics education, move to an overview of what is currently available and what is not for the region, and then outline a discussion of what it means to be local using example cases drawn from Hong Kong, Australia, Pakistan, and Malaysia. We are not creating a casebook but rather constructing by example a toolbox for designing active and dynamic learning cases using regional diversity as contextualised cases with generalised principles.
    Matched MeSH terms: Reference Standards
  12. Bochud F, Cantone MC, Applegate K, Coffey M, Damilakis J, Del Rosario Perez M, et al.
    Ann ICRP, 2020 Dec;49(1_suppl):143-153.
    PMID: 32777956 DOI: 10.1177/0146645320929630
    Whereas scientific evidence is the basis for recommendations and guidance on radiological protection, professional ethics is critically important and should always guide professional behaviour. The International Commission on Radiological Protection (ICRP) established Task Group 109 to advise medical professionals, patients, families, carers, the public, and authorities about the ethical aspects of radiological protection of patients in the diagnostic and therapeutic use of radiation in medicine. Occupational exposures and research-related exposures are not within the scope of this task group. Task Group 109 will produce a report that will be available to the different interested parties for consultation before publication. Presently, the report is at the stage of a working document that has benefitted from an international workshop organised on the topic by the World Health Organization. It presents the history of ethics in medicine in ICRP, and explains why this subject is important, and the benefits it can bring to the standard biomedical ethics. As risk is an essential part in decision-making and communication, a summary is included on what is known about the dose-effect relationship, with emphasis on the associated uncertainties. Once this theoretical framework has been presented, the report becomes resolutely more practical. First, it proposes an evaluation method to analyse specific situations from an ethical point of view. This method allows stakeholders to review a set of six ethical values and provides hints on how they could be balanced. Next, various situations (e.g. pregnancy, elderly, paediatric, end of life) are considered in two steps: first within a realistic, ethically challenging scenario on which the evaluation method is applied; and second within a more general context. Scenarios are presented and discussed with attention to specific patient circumstances, and on how and which reflections on ethical values can be of help in the decision-making process. Finally, two important related aspects are considered: how should we communicate with patients, family, and other stakeholders; and how should we incorporate ethics into the education and training of medical professionals?
    Matched MeSH terms: Reference Standards
  13. Boo SY, Tan SW, Alitheen NB, Ho CL, Omar AR, Yeap SK
    Sci Rep, 2020 05 22;10(1):8561.
    PMID: 32444639 DOI: 10.1038/s41598-020-65474-3
    Due to the limitations in the range of antibodies recognising avian viruses, quantitative real-time PCR (RT-qPCR) is still the most widely used method to evaluate the expression of immunologically related genes in avian viruses. The objective of this study was to identify suitable reference genes for mRNA expression analysis in chicken intraepithelial lymphocyte natural killer (IEL-NK) cells after infection with very-virulent infectious bursal disease virus (vvIBDV). Fifteen potential reference genes were selected based on the references available. The coefficient of variation percentage (CV%) and average count of these 15 genes were determined by NanoString technology for control and infected samples. The M and V values for shortlisted reference genes (ACTB, GAPDH, HMBS, HPRT1, SDHA, TUBB1 and YWHAZ) were calculated using geNorm and NormFinder. GAPDH, YWHAZ and HMBS were the most stably expressed genes. The expression levels of three innate immune response related target genes, CASP8, IL22 and TLR3, agreed in the NanoString and RNA sequencing (RNA-Seq) results using one or two reference genes for normalisation (not HMBS). In conclusion, GAPDH and YWHAZ could be used as reference genes for the normalisation of chicken IEL-NK cell gene responses to infection with vvIBDV.
    Matched MeSH terms: Reference Standards
  14. Brooke GE
    Matched MeSH terms: Reference Standards
  15. CHUA KAH WAI, LOY KAK CHOON, RUWAIDIAH IDRIS
    MyJurnal
    Ordinary Differential Equations (ODEs) are usually used in numerous fields especially in solving the modelling problem. Numerical methods are one of the vital mathematical tools to solve the ODEs that appear in various modelling problems by determining the approximation solution close to the in exact solution if it exists. Runge-Kutta methods (RK) are the numerical methods used to integrate the ODEs by applying multistage methods at the midpoint of an interval which can efficiently produce a more accurate result or small magnitude of error. We proposed Runge-Kutta methods (RK) to solve the 1st_ order nonlinear stiff ODEs. The RK methods used in this research are known as the RK-2, RK-4, and RK-5 methods. We proved the existence and uniqueness of the ODEs before we solved it numerically. We also proved the absolute-stability of the RK methods to determine the overall stability of these methods. We found two suitable test cases which are the standard test problem and manufactured solution. We proved that by combining the adaptive step size with RK methods can result in more efficient computation. We implemented the 2nd_, 4th_ and 5th_ order of RK methods with step size adaptively algorithm to solve the test problem and manufactured solution via Octave programming language. The resulting numerical error and the stability of each method can be studied. We compared our results using several error plots versus the Central Processing Unit (CPU) time required to compute a given nonlinear 1st_ order stiff ODE problem. In a conclusion, RK methods which combine with the adaptive step size can result in more efficient computation and accuracy compare with the fixed step size RK methods.
    Matched MeSH terms: Reference Standards
  16. Chan KL, Choo CY, Morita H, Itokawa H
    Planta Med, 1998 Dec;64(8):741-5.
    PMID: 17253320 DOI: 10.1055/s-2006-957570
    An analytical method using HPLC with UV detection was developed to investigate the quassinoid content of Eurycoma longifolia Jack (Simaroubaceae) collected from various sources. Eurycomanone (1), longilactone (2), 14,15beta-dihydroxyklaineanone (3), 15beta-acetyl-14-hydroxyklaineanone (4), 6alpha-hydroxyeurycomalactone (5), and eurycomalactone (7) were isolated as reference standards and together with the synthesized 1beta,12alpha,15beta-triacetyleurycomanone (6, internal standard), were identified by NMR, MS, UV and IR spectroscopies. Their coefficient of variation values for 0.50-35 microg ml(-1) concentrations of quassinoids and their retention times measured within- and between-day were small. The recoveries of the spiked quassinoids in E. longifolia samples and their detection limits at 8.5 times signal to noise ratio were 99.75-109.13% and 0.01 microg ml(-1), respectively. From the root samples analysed, 1 had the highest concentration, being about 16.8-39.6 fold higher than the other quassinoids 2, 3, 5, 7 but 145.3 fold higher than 4 which showed the lowest concentration.
    Matched MeSH terms: Reference Standards
  17. Che Alhadi S, Wan Zain WZ, Zahari Z, Md Hashim MN, Syed Abd Aziz SH, Zakaria Z, et al.
    Ann Coloproctol, 2020 Dec;36(6):409-414.
    PMID: 32972105 DOI: 10.3393/ac.2020.08.27
    PURPOSE: Guaiac fecal occult blood test (gFOBT) has been the standard for colorectal screening but it has low sensitivity and specificity. This study evaluated the use of fecal tumor M2-pyruvate kinase (M2-PK) for detection of colorectal cancer and to compare with the current surveillance tool; gFOBT in symptomatic adult subjects underwent colonoscopy.

    METHODS: Stool samples were collected prospectively from symptomatic adults who had elective colonoscopy from September 2014 to January 2016 and were analyzed with the ScheBo M2-PK Quick test and laboratory detection of fecal hemoglobin.

    RESULTS: The results were correlated to the colonoscopy findings and/or histopathology report. Eighty-five subjects (age of 56.8 ± 15.3 years [mean ± standard deviation]) were recruited with a total of 17 colorectal cancer (20.0%) and 10 colorectal adenoma patients (11.8%). The sensitivity of M2-PK test in colorectal cancer detection was higher than gFOBT (100% vs. 64.7%). M2-PK test had a lower specificity when compared to gFOBT (72.5% vs. 88.2%) in colorectal cancer detection. The positive and negative predictive values were 47.2% and 100% for M2-PK test and 57.9% and 90.9% for gFOBT.

    CONCLUSION: Fecal M2-PK Quick test has a high sensitivity for detection of colorectal cancer when compared to gFOBT, making it the potential choice for colorectal tumor screening biomarker in the future.

    Matched MeSH terms: Reference Standards
  18. Che HL, Tan DM, Meganathan P, Gan YL, Abdul Razak G, Fu JY
    Int J Anal Chem, 2015;2015:357609.
    PMID: 26604927 DOI: 10.1155/2015/357609
    Quantification of tocotrienols in human plasma is critical when the attention towards tocotrienols on its distinctive properties is arising. We aim to develop a simple and practical normal-phase high performance liquid chromatography method to quantify the amount of four tocotrienol homologues in human plasma. Using both the external and internal standards, tocotrienol homologues were quantified via a normal-phase high performance liquid chromatography with fluorescence detector maintained at the excitation wavelength of 295 nm and the emission wavelength of 325 nm. The four tocotrienol homologues were well separated within 30 minutes. A large interindividual variation between subjects was observed as the absorption of tocotrienols is dependent on food matrix and gut lipolysis. The accuracies of lower and upper limit of quantification ranged between 92% and 109% for intraday assays and 90% and 112% for interday assays. This method was successfully applied to quantify the total amount of four tocotrienol homologues in human plasma.
    Matched MeSH terms: Reference Standards
  19. Che Mohd Hilmi Che Mat1, Zulkiflee Salahuddin, Nik Azrizie Muhamed, Irfan Mohamad
    MyJurnal
    Osteomas occur in all parts of the temporal bone, including the mastoid, squamous, middle
    ear, styloid process, internal auditory canal and external auditory canal (EAC). The EAC has
    been reported to be the most common site, followed by the mastoid and squamous parts.
    Diagnosis is made based on history, clinical examination and radiological findings. Computed
    tomography reveals a pedunculated hyperdense mass that usually arises from the
    tympanosquamous suture. Surgical removal of EAC osteomas can be achieved using the
    endaural or postauricular approaches. It can be performed with a drill or osteotome, either
    endoscopically or by using microscopy. This report presents two patients with EAC osteomas
    who underwent excision under microscopy using the endaural approach. Surgery is the gold
    standard treatment, while close observation may be considered in asymptomatic patients.
    Matched MeSH terms: Reference Standards
  20. Cheah PY, Yuen KH, Liong ML
    J Chromatogr B Biomed Sci Appl, 2000 Aug 18;745(2):439-43.
    PMID: 11043762
    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.
    Matched MeSH terms: Reference Standards
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links