Displaying publications 41 - 60 of 287 in total

Abstract:
Sort:
  1. Chan PL, Tan FHS
    Clin Hypertens, 2018;24:15.
    PMID: 30410790 DOI: 10.1186/s40885-018-0100-x
    Background: Hypokalemia in the presence of hypertension is often attributed to primary hyperaldosteronism as a cause of secondary hypertension, however secondary hyperaldosteronism may present similarly. Accessory renal arteries are variants in the vascular anatomy which are often thought to be innocuous but in some circumstances can cause renovascular hypertension leading to secondary hyperaldosteronism.

    Case presentation: We report 2 cases of hypertension with secondary hyperaldosteronism associated with accessory renal arteries. Both patients presented with hypokalemia and further investigations revealed hyperaldosteronism with unsuppressed renin levels. Imaging studies showed the presence of accessory renal artery.

    Conclusion: Accessory renal arteries are a potential cause renovascular hypertension which can be detected via CT angiography or magnetic resonance angiography. Hormonal evaluation should be undertaken to determine whether its presence contributes to hypertension in the patient as targeted treatment such as aldosterone antagonist can be initiated. Surgical intervention or renal denervation may be considered in resistant cases.

    Matched MeSH terms: Magnetic Resonance Angiography; Computed Tomography Angiography
  2. Halmi Shamsudin, Norman Nordin, Sa’don Samian, Hafiz Salahudin, Azrul, A.B., Nik Azuan, N.I., et al.
    Jurnal Inovasi Malaysia, 2018;2(1):31-50.
    MyJurnal
    Angiography procedures is one of the diagnostic imaging procedures for studying blood vessels in the arteries and veins. This angiography examination is performed by injecting a viscous liquid called contrast media into the blood vessels to clearly identify the blocked blood vessels. This procedure involves the exposure of X-Ray in certain blood vessels and is performed by the Interventionist Radiologist. There are several types of angiography examinations which include cerebral angiography, coronary angiography, pulmonary angiography, peripheral angiography and renal angiography. The main problem that occurs during the Lower Limb Angiography examination involving elderly patients aged 60 years and above who suffer from critical diabetes stage in both blood vessels. The problem arise when there is no special immobilize device to support the foot and the patients were in an uncomfortable state for a period of 2-3 hours during the examination. Hence specialists had difficulty to interpret accurately the blood vessel clot in the foot due to less optimum radiograph. IMMOLIMBTM is an innovative invention created from used waste to overcome the foot movements, providing comfort and enhancing optimum diagnostic images.
    Matched MeSH terms: Cerebral Angiography; Coronary Angiography
  3. Cheong, Chee Yen, Rashidi Ahmad, Nesarajah, Kiran, Aida Bustam, Muhaimin Noor Azhar
    MyJurnal
    Diagnosis of pulmonary embolism (PE) remains a challenge in clinical practice, especially in emergency setting despite availability of various diagnostic tools. It is desirable to have a rapid and accurate bedside test to rule out PE.The aim of this study is to evaluate the diagnostic accuracyof CUEPED, a novel method of ruling out pulmonary embolism using a combination of end-tidal CO2(ETCO2), Compression Ultrasonography (CUS) and Transthoracic Echocardiography (TTE).In this pilot study, patients who presented to the Emergency Department at Univers it y Malaya Medical Centre with suspected acute PE from December 2013 to October 2014,who fulfilled the inclusion and exclusion criteria, were assessed using CUEPED. CUEPED was considered positive if the measured ETCO2 was less than 35 mmHg, or if there was presence of venous incompressibility in lower limb ultrasonography orif tricuspid annular plane systolic excursion (TAPSE) in transthoracic echocardiography was less than 1.6. All patients received a computed tomography pulmonary angiography (CTPA) for confirmation of diagnosis. Data obtained was analyzed to determine if a negative CUEPED has the potential to accurately rule out a PE. 30 patients (mean age = 48 years [SD = 13.6]) were involved with an equal distribut io nbetween gender. The incidence of PE was 56.7%. CUEPED had a sensitivity of 100% for PE. Negative CUEPED ruled out PE with a negative predictive value of 100%. Positive CUEPED ruled in PE with a low specificity of 53.8% and moderate positive predictive value of 73.9%. This diagnostic study showedthat a negative CUEPED is potentially accurate in ruling out PE.
    Matched MeSH terms: Angiography; Computed Tomography Angiography
  4. Tajfard M, Latiff LA, Rahimi HR, Moohebati M, Hasanzadeh M, Emrani AS, et al.
    Mol Cell Biochem, 2017 Nov;435(1-2):37-45.
    PMID: 28534120 DOI: 10.1007/s11010-017-3054-5
    Cytokines play a key role in the pathogenesis of coronary artery disease (CAD). The aim of current study was to investigate the relationship between the serum concentrations of 12 cytokines with mortality and extent of CAD in individuals undergoing angiography and healthy controls. 342 CAD patients were recruited and divided into 2 groups: those with ≥50% occlusion in at least one coronary artery [Angiography (+)] or <50% obstruction in coronary arteries [Angiography (-)]. Also 120 healthy subjects were enrolled as control group. Lipid profile, fasting blood glucose, body mass index, and blood pressure were evaluated in all the subjects. An Evidence Investigator® was used for measuring 12 cytokines (IL-1α, IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, TNF-α, MCP-1, IFN-γ, EGF, VEGF) using sandwich chemiluminescent assays. Univariate analysis, multivariate regression models, ROC, and Kaplan-Meier survival curves were used for exploring the candidate markers in CAD patients. Serum level of IFN-γ, IL-4, MCP-1, EGF, IL-6, and IL-8 were markedly higher in angiogram-positive patients, while VEGF concentrations were significantly (P 2.16 pg/mL IL-6 had a > 94% sensitivity and 70% specificity in predicting 2 years mortality in the subjects with a serum MCP-1 > 61.95 pg/ mL, and patients having IL-6/MCP-1 combination had a shorter survival.Our findings demonstrate that CAD patients with serum MCP-1 and IL-6 levels of >61.95 and >2.16 pg/mL had a higher mortality with 94.1% sensitivity and 70.5% specificity for predicting mortality in CAD patients.
    Matched MeSH terms: Coronary Angiography*
  5. Gheith OA, Nagib AM, Halim MA, Mahmoud T, Nair P, Abo-Atya H, et al.
    Iran J Kidney Dis, 2023 Jan;1(1):47-53.
    PMID: 36739490
    INTRODUCTION: Data regarding contrast-induced nephropathy (CIN) in kidney transplant (KT) recipients are scarce despite the distinct risk factors such as the use of immunosuppressive agents, sympathetic denervation, glomerular hyperfiltration, and high prevalence of the cardiovascular disease. This study aimed to determine the prevalence of CIN in KT recipients who received low-osmolality iodine-based contrast material (CM) for radiological assessment.

    METHODS: Between 2010 and 2020, 79 of the 3180 KT recipients followed at Hamed Al-Essa organ transplant center received low-osmolality iodine-based contrast for radiological assessment for various indications. Preventive measures including holding metformin, intravenous hydration, sodium bicarbonate and N-acetylcysteine were given before contrast administration. CIN was defined as an increase in serum creatinine of 25% from the baseline within 72 hours.

    RESULTS: The enrolled patients were divided into two groups: those who developed CIN (n = 7) and those with no increase in serum creatinine level (n = 72). The mean age of the patients was 52.1 ± 12.3 years; 44 of them were males, and the cause of end-stage kidney disease was mostly diabetic nephropathy. The pre-transplant demographics were comparable between the two groups. Fortyseven cases received contrast for coronary angiography, and 32 received it for a CT scan. The graft function deteriorated in group 1, but no significant difference was found between the two groups at the end of the study.

    CONCLUSION: CIN is not uncommon in KT recipients receiving CM, especially with ischemic heart disease. Risk stratification, optimizing hemodynamics, and avoiding potential nephrotoxins are essential before performing CM-enhanced studies in KT recipients.  DOI: 10.52547/ijkd.7165.

    Matched MeSH terms: Coronary Angiography/adverse effects
  6. Sun CZ, Sim SSKP, Vyas CH, Lott PW, Gunatheesan R, Teo KYC, et al.
    Eye (Lond), 2022 Jun;36(6):1143.
    PMID: 35046551 DOI: 10.1038/s41433-021-01859-6
    Matched MeSH terms: Fluorescein Angiography/methods
  7. Pee XK, Low A, Ab Kahar MEPI, Mohamed SO, Chong YJ
    BMC Ophthalmol, 2023 Nov 07;23(1):444.
    PMID: 37932684 DOI: 10.1186/s12886-023-03186-8
    BACKGROUND: To report a rare case of pulmonary and ocular complications with visual loss due to bilateral Purtscher-like retinopathy and paracentral acute middle maculopathy (PAMM) following a hyaluronic acid (HA) filler injection to the breast. Systemic and visual recovery was attained following corticosteroid therapy.

    CASE PRESENTATION: A 27-year-old lady presented with painless blurring of vision in both eyes for 2 weeks following hyaluronic acid breast filler injections by a non-medical practitioner. She was initially admitted to the medical ward for diffuse alveolar haemorrhage and altered sensorium. The presenting visual acuity was counting fingers in both eyes. Bilateral dilated fundus examination showed hyperaemic discs, concentric rim of retinal whitening around macula with patches of polygonal-shaped retinal whitening, generalised cotton-wool spots, tortuous veins, and flame-shaped haemorrhages. Spectral-domain optical coherence tomography (SD-OCT) macula revealed hyper-reflective bands at the inner nuclear layer (INL). Fluorescein angiography demonstrated hot discs, delayed arm-to-retina time, arterial filling, and arterio-venous transit time with staining of the vessels at the posterior pole. She was managed with a tapering dose of systemic corticosteroids. The visual acuity improved to 6/12 over 8 weeks with significant anatomical and functional improvement. Dilated fundus examination showed resolution of initial funduscopy findings. The hyper-reflective bands on the OCT had resolved with subsequent thinning of the INL and disorganisation of retinal inner layers.

    CONCLUSION: Filler injections are in increasing demand and are frequently being performed by non-medical practitioners. Visual loss from non-facial HA fillers is rare. Inadvertent entry of HA into a blood vessel may potentially cause systemic and sight-threatening ocular complications. Good anatomical knowledge and proper injection technique are vital in preventing this unfortunate sequela. There are limited reports on successful visual recovery following various treatment approaches and we hope this case provides valuable insights.

    Matched MeSH terms: Fluorescein Angiography/methods
  8. Raffali MAA, Azmi MI, Muhammad SF, Che Hassan HH
    BMJ Case Rep, 2024 Apr 29;17(4).
    PMID: 38684352 DOI: 10.1136/bcr-2024-260649
    A man in his 20s with no medical illness sustained a blunt chest injury with pneumothorax and lung contusion after involving in a motorbike accident. Five days postadmission, he subsequently had myocardial infarction with cardiac arrest, in which coronary angiogram and intravascular ultrasound showed diffused multivessel coronary artery dissection.
    Matched MeSH terms: Coronary Angiography*
  9. Laricchia A, Bossi I, Latini RA, Lee CY, Pérez IS, Tomai F, et al.
    Rev Esp Cardiol (Engl Ed), 2024 Jul;77(7):527-536.
    PMID: 38056772 DOI: 10.1016/j.rec.2023.11.010
    INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS).

    METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events.

    RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure.

    CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

    Matched MeSH terms: Coronary Angiography*
  10. Ong JL, Jalaludin S
    Malays J Med Sci, 2016 Mar;23(2):78-81.
    PMID: 27547119 MyJurnal
    The purpose is to describe a case of traumatic right extracranial internal carotid artery (EICA) pseudoaneurysm, which is a rare entity and the evolution of treatment from surgery to minimally invasive intervention by endovascular stenting and coiling. We reported a case of traumatic right EICA pseudoaneurysm who presented with multiple cranial nerve palsies. Multiple radiological examinations [including magnetic resonance imaging (MRI) with angiogram, computed tomography angiogram (CTA), and digital subtraction angiogram (DSA)] demonstrated right EICA pseudoaneurysm. The pseudoaneurysm was successfully treated with endovascular stenting and coiling. EICA pseudoaneurysm is a rare entity, and open surgery was the gold standard of treatment. Current technology allows endovascular stenting and coiling of pseudoaneurysm as an alternative treatment. It is minimally invasive, associated with lesser complications, better recovery and a shorter hospital stay.
    Matched MeSH terms: Angiography, Digital Subtraction; Computed Tomography Angiography
  11. Wong SC, Nawawi O, Ramli N, Abd Kadir KA
    Acad Radiol, 2012 Jun;19(6):701-7.
    PMID: 22578227 DOI: 10.1016/j.acra.2012.02.012
    The aim of this study was to compare conventional two-dimensional (2D) digital subtraction angiography (DSA) with three-dimensional (3D) rotational DSA in the investigation of intracranial aneurysm in terms of detection, size measurement, neck diameter, neck delineation, and relationship with surrounding vessels. A further aim was to compare radiation dose, contrast volume, and procedural time between the two protocols.
    Matched MeSH terms: Cerebral Angiography/methods*; Angiography, Digital Subtraction/methods*
  12. Mohanaraj T, Hanif H, Zainal AA
    Med J Malaysia, 2015 Feb;70(1):31-2.
    PMID: 26032526 MyJurnal
    Gastrointestinal stromal tumours (GIST) are rare gastrointestinal tumours and are one of the causes of obscure gastrointestinal bleeding. We report a case of massive gastrointestinal bleeding secondary to bleeding jejunal GIST in a 43 years old gentleman. Endoscopic intervention failed to identify the source of bleeding and CT Angiography (CTA) showed a jejunal mass and patient underwent laparotomy and resection of the bleeding jejunal GIST. This article highlights the rare cause of the massive GI bleeding and also emphasise the role of CTA in obscure GI bleeding.
    Matched MeSH terms: Computed Tomography Angiography
  13. Soo YS
    Med J Malaya, 1971 Jun;25(4):288-92.
    PMID: 4261303
    Matched MeSH terms: Cerebral Angiography
  14. Yip VCH, Wong HT, Yong VKY, Lim BA, Hee OK, Cheng J, et al.
    J Glaucoma, 2019 07;28(7):e132-e133.
    PMID: 31135585 DOI: 10.1097/IJG.0000000000001289
    Matched MeSH terms: Angiography
  15. Alisa-Victoria K, Jin-Poi T, Shatriah I, Zunaina E, Ngah NF
    Clin Ophthalmol, 2014;8:537-42.
    PMID: 24648718 DOI: 10.2147/OPTH.S55623
    Best's vitelliform macular dystrophy complicated with choroidal neovascularization is rare in children. We report three children from a Malay family of five siblings with Best's vitelliform macular dystrophy, in which two of them subsequently developed choroidal neovascularization. The possible pathogenesis of this rare condition is described and highlighted in this report.
    Matched MeSH terms: Fluorescein Angiography
  16. Primuharsa Putra. S.H.A., Nurliza, I., Roszalina, R., Saim, L., Zahiah, M.
    MyJurnal
    We present two cases of direct traumatic carotico-cavernous fistula following motor vehicle accident. Their main symptoms include loss of vision, progressive proptosis and recurrent epistaxis. Angiogram confirmed presence of carotico-cavernous fistula in both cases. One was successfully treated by open surgery and the other by embolization with Guglielmi detachable coils (GDC). In both cases, proptosis and epistaxis resolved completely.
    Matched MeSH terms: Angiography
  17. Pandya A, Yu YJ, Ge Y, Nagel E, Kwong RY, Bakar RA, et al.
    J Cardiovasc Magn Reson, 2022 01 06;24(1):1.
    PMID: 34986851 DOI: 10.1186/s12968-021-00833-1
    BACKGROUND: Although prior reports have evaluated the clinical and cost impacts of cardiovascular magnetic resonance (CMR) for low-to-intermediate-risk patients with suspected significant coronary artery disease (CAD), the cost-effectiveness of CMR compared to relevant comparators remains poorly understood. We aimed to summarize the cost-effectiveness literature on CMR for CAD and create a cost-effectiveness calculator, useable worldwide, to approximate the cost-per-quality-adjusted-life-year (QALY) of CMR and relevant comparators with context-specific patient-level and system-level inputs.

    METHODS: We searched the Tufts Cost-Effectiveness Analysis Registry and PubMed for cost-per-QALY or cost-per-life-year-saved studies of CMR to detect significant CAD. We also developed a linear regression meta-model (CMR Cost-Effectiveness Calculator) based on a larger CMR cost-effectiveness simulation model that can approximate CMR lifetime discount cost, QALY, and cost effectiveness compared to relevant comparators [such as single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA)] or invasive coronary angiography.

    RESULTS: CMR was cost-effective for evaluation of significant CAD (either health-improving and cost saving or having a cost-per-QALY or cost-per-life-year result lower than the cost-effectiveness threshold) versus its relevant comparator in 10 out of 15 studies, with 3 studies reporting uncertain cost effectiveness, and 2 studies showing CCTA was optimal. Our cost-effectiveness calculator showed that CCTA was not cost-effective in the US compared to CMR when the most recent publications on imaging performance were included in the model.

    CONCLUSIONS: Based on current world-wide evidence in the literature, CMR usually represents a cost-effective option compared to relevant comparators to assess for significant CAD.

    Matched MeSH terms: Coronary Angiography
  18. Sciahbasi A, Salvi N, Heang TM, Perez IS, Geraci S, Vaccaro G, et al.
    Catheter Cardiovasc Interv, 2024 Mar;103(4):532-538.
    PMID: 38415895 DOI: 10.1002/ccd.30996
    BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited.

    AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries.

    METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality.

    RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003).

    CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.

    Matched MeSH terms: Coronary Angiography
  19. Abdullah KA, McEntee MF, Reed WM, Kench PL
    J Appl Clin Med Phys, 2020 Sep;21(9):209-214.
    PMID: 32657493 DOI: 10.1002/acm2.12977
    PURPOSE: The purpose of this study was to investigate the effect of increasing iterative reconstruction (IR) algorithm strength at different tube voltages in coronary computed tomography angiography (CCTA) protocols using a three-dimensional (3D)-printed and Catphan® 500 phantoms.

    METHODS: A 3D-printed cardiac insert and Catphan 500 phantoms were scanned using CCTA protocols at 120 and 100 kVp tube voltages. All CT acquisitions were reconstructed using filtered back projection (FBP) and Adaptive Statistical Iterative Reconstruction (ASIR) algorithm at 40% and 60% strengths. Image quality characteristics such as image noise, signal-noise ratio (SNR), contrast-noise ratio (CNR), high spatial resolution, and low contrast resolution were analyzed.

    RESULTS: There was no significant difference (P > 0.05) between 120 and 100 kVp measures for image noise for FBP vs ASIR 60% (16.6 ± 3.8 vs 16.7 ± 4.8), SNR of ASIR 40% vs ASIR 60% (27.3 ± 5.4 vs 26.4 ± 4.8), and CNR of FBP vs ASIR 40% (31.3 ± 3.9 vs 30.1 ± 4.3), respectively. Based on the Modulation Transfer Function (MTF) analysis, there was a minimal change of image quality for each tube voltage but increases when higher strengths of ASIR were used. The best measure of low contrast detectability was observed at ASIR 60% at 120 kVp.

    CONCLUSIONS: Changing the IR strength has yielded different image quality noise characteristics. In this study, the use of 100 kVp and ASIR 60% yielded comparable image quality noise characteristics to the standard CCTA protocols using 120 kVp of ASIR 40%. A combination of 3D-printed and Catphan® 500 phantoms could be used to perform CT dose optimization protocols.

    Matched MeSH terms: Coronary Angiography; Computed Tomography Angiography*
  20. Sabarudin A, Sun Z, Yusof AK
    Int J Cardiol, 2013 Sep 30;168(2):746-53.
    PMID: 23098849 DOI: 10.1016/j.ijcard.2012.09.217
    This study is conducted to investigate and compare image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated coronary CT angiography (CCTA) with the use of single-source CT (SSCT) and dual-source CT (DSCT).
    Matched MeSH terms: Coronary Angiography/methods; Coronary Angiography/standards*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links