Case presentation: We report 2 cases of hypertension with secondary hyperaldosteronism associated with accessory renal arteries. Both patients presented with hypokalemia and further investigations revealed hyperaldosteronism with unsuppressed renin levels. Imaging studies showed the presence of accessory renal artery.
Conclusion: Accessory renal arteries are a potential cause renovascular hypertension which can be detected via CT angiography or magnetic resonance angiography. Hormonal evaluation should be undertaken to determine whether its presence contributes to hypertension in the patient as targeted treatment such as aldosterone antagonist can be initiated. Surgical intervention or renal denervation may be considered in resistant cases.
METHODS: Between 2010 and 2020, 79 of the 3180 KT recipients followed at Hamed Al-Essa organ transplant center received low-osmolality iodine-based contrast for radiological assessment for various indications. Preventive measures including holding metformin, intravenous hydration, sodium bicarbonate and N-acetylcysteine were given before contrast administration. CIN was defined as an increase in serum creatinine of 25% from the baseline within 72 hours.
RESULTS: The enrolled patients were divided into two groups: those who developed CIN (n = 7) and those with no increase in serum creatinine level (n = 72). The mean age of the patients was 52.1 ± 12.3 years; 44 of them were males, and the cause of end-stage kidney disease was mostly diabetic nephropathy. The pre-transplant demographics were comparable between the two groups. Fortyseven cases received contrast for coronary angiography, and 32 received it for a CT scan. The graft function deteriorated in group 1, but no significant difference was found between the two groups at the end of the study.
CONCLUSION: CIN is not uncommon in KT recipients receiving CM, especially with ischemic heart disease. Risk stratification, optimizing hemodynamics, and avoiding potential nephrotoxins are essential before performing CM-enhanced studies in KT recipients. DOI: 10.52547/ijkd.7165.
CASE PRESENTATION: A 27-year-old lady presented with painless blurring of vision in both eyes for 2 weeks following hyaluronic acid breast filler injections by a non-medical practitioner. She was initially admitted to the medical ward for diffuse alveolar haemorrhage and altered sensorium. The presenting visual acuity was counting fingers in both eyes. Bilateral dilated fundus examination showed hyperaemic discs, concentric rim of retinal whitening around macula with patches of polygonal-shaped retinal whitening, generalised cotton-wool spots, tortuous veins, and flame-shaped haemorrhages. Spectral-domain optical coherence tomography (SD-OCT) macula revealed hyper-reflective bands at the inner nuclear layer (INL). Fluorescein angiography demonstrated hot discs, delayed arm-to-retina time, arterial filling, and arterio-venous transit time with staining of the vessels at the posterior pole. She was managed with a tapering dose of systemic corticosteroids. The visual acuity improved to 6/12 over 8 weeks with significant anatomical and functional improvement. Dilated fundus examination showed resolution of initial funduscopy findings. The hyper-reflective bands on the OCT had resolved with subsequent thinning of the INL and disorganisation of retinal inner layers.
CONCLUSION: Filler injections are in increasing demand and are frequently being performed by non-medical practitioners. Visual loss from non-facial HA fillers is rare. Inadvertent entry of HA into a blood vessel may potentially cause systemic and sight-threatening ocular complications. Good anatomical knowledge and proper injection technique are vital in preventing this unfortunate sequela. There are limited reports on successful visual recovery following various treatment approaches and we hope this case provides valuable insights.
METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events.
RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure.
CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.
METHODS: We searched the Tufts Cost-Effectiveness Analysis Registry and PubMed for cost-per-QALY or cost-per-life-year-saved studies of CMR to detect significant CAD. We also developed a linear regression meta-model (CMR Cost-Effectiveness Calculator) based on a larger CMR cost-effectiveness simulation model that can approximate CMR lifetime discount cost, QALY, and cost effectiveness compared to relevant comparators [such as single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA)] or invasive coronary angiography.
RESULTS: CMR was cost-effective for evaluation of significant CAD (either health-improving and cost saving or having a cost-per-QALY or cost-per-life-year result lower than the cost-effectiveness threshold) versus its relevant comparator in 10 out of 15 studies, with 3 studies reporting uncertain cost effectiveness, and 2 studies showing CCTA was optimal. Our cost-effectiveness calculator showed that CCTA was not cost-effective in the US compared to CMR when the most recent publications on imaging performance were included in the model.
CONCLUSIONS: Based on current world-wide evidence in the literature, CMR usually represents a cost-effective option compared to relevant comparators to assess for significant CAD.
AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries.
METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality.
RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003).
CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.
METHODS: A 3D-printed cardiac insert and Catphan 500 phantoms were scanned using CCTA protocols at 120 and 100 kVp tube voltages. All CT acquisitions were reconstructed using filtered back projection (FBP) and Adaptive Statistical Iterative Reconstruction (ASIR) algorithm at 40% and 60% strengths. Image quality characteristics such as image noise, signal-noise ratio (SNR), contrast-noise ratio (CNR), high spatial resolution, and low contrast resolution were analyzed.
RESULTS: There was no significant difference (P > 0.05) between 120 and 100 kVp measures for image noise for FBP vs ASIR 60% (16.6 ± 3.8 vs 16.7 ± 4.8), SNR of ASIR 40% vs ASIR 60% (27.3 ± 5.4 vs 26.4 ± 4.8), and CNR of FBP vs ASIR 40% (31.3 ± 3.9 vs 30.1 ± 4.3), respectively. Based on the Modulation Transfer Function (MTF) analysis, there was a minimal change of image quality for each tube voltage but increases when higher strengths of ASIR were used. The best measure of low contrast detectability was observed at ASIR 60% at 120 kVp.
CONCLUSIONS: Changing the IR strength has yielded different image quality noise characteristics. In this study, the use of 100 kVp and ASIR 60% yielded comparable image quality noise characteristics to the standard CCTA protocols using 120 kVp of ASIR 40%. A combination of 3D-printed and Catphan® 500 phantoms could be used to perform CT dose optimization protocols.