Displaying publications 41 - 60 of 212 in total

Abstract:
Sort:
  1. Fah NT
    Med J Malaysia, 1977 Jun;31(4):309-15.
    PMID: 927238
    Matched MeSH terms: Electrocardiography*
  2. Ng KH
    Med J Malaysia, 1983 Dec;38(4):289-93.
    PMID: 6599984
    One of the important functions of the Coronary Care Unit (CCU) is the continuous and intensive monitoring of cardiac function. To date, many monitoring techniques have been developed and tested. In this paper, both the conventional and computerised monitoring techniques are reviewed and evaluated. It is shown that a computerised system has several defirute advantages over the conventional system, e.g. lower false alarm rate, accurate and fast data processing, retrospective studies. However one also ought to be aware of the limitations,
    Matched MeSH terms: Electrocardiography*
  3. Burns-Cox CJ, Lau LC, Toh BH
    J Electrocardiol, 1971;4(3):211-9.
    PMID: 5126628
    Matched MeSH terms: Electrocardiography*
  4. Sidek KA, Khalil I
    PMID: 22255160 DOI: 10.1109/IEMBS.2011.6090644
    This paper presents a person identification mechanism in irregular cardiac conditions using ECG signals. A total of 30 subjects were used in the study from three different public ECG databases containing various abnormal heart conditions from the Paroxysmal Atrial Fibrillation Predicition Challenge database (AFPDB), MIT-BIH Supraventricular Arrthymia database (SVDB) and T-Wave Alternans Challenge database (TWADB). Cross correlation (CC) was used as the biometric matching algorithm with defined threshold values to evaluate the performance. In order to measure the efficiency of this simple yet effective matching algorithm, two biometric performance metrics were used which are false acceptance rate (FAR) and false reject rate (FRR). Our experimentation results suggest that ECG based biometric identification with irregular cardiac condition gives a higher recognition rate of different ECG signals when tested for three different abnormal cardiac databases yielding false acceptance rate (FAR) of 2%, 3% and 2% and false reject rate (FRR) of 1%, 2% and 0% for AFPDB, SVDB and TWADB respectively. These results also indicate the existence of salient biometric characteristics in the ECG morphology within the QRS complex that tends to differentiate individuals.
    Matched MeSH terms: Electrocardiography/methods*
  5. Martis RJ, Acharya UR, Adeli H
    Comput Biol Med, 2014 May;48:133-49.
    PMID: 24681634 DOI: 10.1016/j.compbiomed.2014.02.012
    The Electrocardiogram (ECG) is the P-QRS-T wave depicting the cardiac activity of the heart. The subtle changes in the electric potential patterns of repolarization and depolarization are indicative of the disease afflicting the patient. These clinical time domain features of the ECG waveform can be used in cardiac health diagnosis. Due to the presence of noise and minute morphological parameter values, it is very difficult to identify the ECG classes accurately by the naked eye. Various computer aided cardiac diagnosis (CACD) systems, analysis methods, challenges addressed and the future of cardiovascular disease screening are reviewed in this paper. Methods developed for time domain, frequency transform domain, and time-frequency domain analysis, such as the wavelet transform, cannot by themselves represent the inherent distinguishing features accurately. Hence, nonlinear methods which can capture the small variations in the ECG signal and provide improved accuracy in the presence of noise are discussed in greater detail in this review. A CACD system exploiting these nonlinear features can help clinicians to diagnose cardiovascular disease more accurately.
    Matched MeSH terms: Electrocardiography/methods*
  6. Teh HS, Tan HJ, Loo CY, Raymond AA
    Med J Malaysia, 2007 Jun;62(2):104-8.
    PMID: 18705439
    Epilepsy patients have a higher mortality rate than the general population. Sudden unexpected death in epilepsy (SUDEP) is a major cause of mortality for these patients. The possibility of cardiac involvement in the pathogenesis of SUDEP has been suggested by many previous studies. This study compared the QT interval in epilepsy patients and normal controls, and identified the factors that affected the QT interval. Standard 12-lead ECGs were recorded from 70 consecutive epilepsy patients from the neurology clinic of HUKM and 70 age, race and gender matched controls. The mean QT interval corrected for heart rate (QTc) was calculated and compared. The mean QTc among the epilepsy patients was 0.401 +/- 0.027s. It was significantly shorter than the QTc (0.420 +/- 0.027s) in the control group (p<0.0005). Thirty five epilepsy patients (50%) and 17 matched controls (24.3%) had a mean QTc shorter than 0.40s (p=0.001). Among the epilepsy patients, the mean QTc did not significantly differ between patients in the duration (F=0.836, p=0.438) of the epilepsy, frequency (F=0.273, p=0.845) and types of seizures (p=0.633). There was no significant difference in the mean QTc between the epilepsy patients on different number of antiepileptic agents (F=0.444, p=0.643). Patients with cryptogenic epilepsy had a mean QTc of 0.392 +/- 0.029s, which was significantly shorter than patients with symptomatic epilepsy (QTc = 0.410 +/- 0.027s, p = 0.015). The mean QTc of the same subjects showed no significant interobserver difference (p=0.661). This study, for the first time, demonstrates that epilepsy patients have a significantly shorter QTc than controls, particularly in the subgroup of patients with cryptogenic epilepsy.
    Study site: Neurology clinic, Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM), Kuala Lumpur, Malaysia
    Matched MeSH terms: Electrocardiography*
  7. Shukimbayeva A, Prilutskaya M, Mansurova J
    Med J Malaysia, 2024 Nov;79(6):703-707.
    PMID: 39614787
    INTRODUCTION: Synthetic cathinones and opioids are among the most commonly used illicit drugs in Central Asia, including Kazakhstan. Despite the advent of synthetic cathinones, opioids have not lost their relevance. Patients frequently report poly-dependence, combining cathinones and opioids. The use of synthetic cathinones and opioids is associated with cardiovascular disease and cardiovascular mortality. However, there is limited data describing the cardiac effects of synthetic cathinones and opioids in patients with post-acute withdrawal syndrome. The aim of this work is to describe and compare the cardiac manifestations in patients using synthetic cathinones and opioids with post-acute withdrawal syndrome.

    MATERIALS AND METHODS: In this case-control study, we examined 294 patients over the age of 18 who were using synthetic cathinones and opioids. All patients underwent electrocardiography and transthoracic echocardiography.

    RESULTS: Our study involved 183 patients using synthetic cathinones and 111 patients reporting opioid use. The average age of the patients was 32.4 ± 8.5 years. In patients using synthetic cathinones, electrocardiography showed a lengthening in the average duration of the ventricular QRS complex (70.5 ± 13.3 ms vs. 69.6 ± 11.7 ms), T wave (154.1 ± 27.5 ms vs. 140.4 ± 24.1 ms), and QT interval (338.2 ± 28.5 ms vs. 334.8 ± 33.5 ms), as well as a shortening of the P wave (79.1 ± 12.2 ms vs. 82.6 ± 14.4 ms) and PQ interval (146.4 ± 19.6 ms vs. 148.3 ± 20.1 ms). Echocardiography confirmed left ventricular hypertrophy in 10.9% of the synthetic cathinones group and 17.1% of the opioid group. Transmitral left ventricular diastolic dysfunction was diagnosed in 23.5% of patients in both groups. Additionally, 31.1% of patients using synthetic cathinones and 44.1% of those using opioids had a reduced ejection fraction on echocardiography.

    CONCLUSION: In patients using synthetic cathinones the QT interval was longer compared to those using opioids. The ejection fraction was lower in the opioid group. Electrocardiographic and echocardiographic screening should be conducted for all patients with post-acute withdrawal syndrome to prevent life-threatening arrhythmias and heart failure.

    Matched MeSH terms: Electrocardiography*
  8. Awais M, Badruddin N, Drieberg M
    Sensors (Basel), 2017 Aug 31;17(9).
    PMID: 28858220 DOI: 10.3390/s17091991
    Driver drowsiness is a major cause of fatal accidents, injury, and property damage, and has become an area of substantial research attention in recent years. The present study proposes a method to detect drowsiness in drivers which integrates features of electrocardiography (ECG) and electroencephalography (EEG) to improve detection performance. The study measures differences between the alert and drowsy states from physiological data collected from 22 healthy subjects in a driving simulator-based study. A monotonous driving environment is used to induce drowsiness in the participants. Various time and frequency domain feature were extracted from EEG including time domain statistical descriptors, complexity measures and power spectral measures. Features extracted from the ECG signal included heart rate (HR) and heart rate variability (HRV), including low frequency (LF), high frequency (HF) and LF/HF ratio. Furthermore, subjective sleepiness scale is also assessed to study its relationship with drowsiness. We used paired t-tests to select only statistically significant features (p < 0.05), that can differentiate between the alert and drowsy states effectively. Significant features of both modalities (EEG and ECG) are then combined to investigate the improvement in performance using support vector machine (SVM) classifier. The other main contribution of this paper is the study on channel reduction and its impact to the performance of detection. The proposed method demonstrated that combining EEG and ECG has improved the system's performance in discriminating between alert and drowsy states, instead of using them alone. Our channel reduction analysis revealed that an acceptable level of accuracy (80%) could be achieved by combining just two electrodes (one EEG and one ECG), indicating the feasibility of a system with improved wearability compared with existing systems involving many electrodes. Overall, our results demonstrate that the proposed method can be a viable solution for a practical driver drowsiness system that is both accurate and comfortable to wear.
    Matched MeSH terms: Electrocardiography
  9. Boon KH, Khalil-Hani M, Malarvili MB
    Comput Methods Programs Biomed, 2018 Jan;153:171-184.
    PMID: 29157449 DOI: 10.1016/j.cmpb.2017.10.012
    This paper presents a method that able to predict the paroxysmal atrial fibrillation (PAF). The method uses shorter heart rate variability (HRV) signals when compared to existing methods, and achieves good prediction accuracy. PAF is a common cardiac arrhythmia that increases the health risk of a patient, and the development of an accurate predictor of the onset of PAF is clinical important because it increases the possibility to electrically stabilize and prevent the onset of atrial arrhythmias with different pacing techniques. We propose a multi-objective optimization algorithm based on the non-dominated sorting genetic algorithm III for optimizing the baseline PAF prediction system, that consists of the stages of pre-processing, HRV feature extraction, and support vector machine (SVM) model. The pre-processing stage comprises of heart rate correction, interpolation, and signal detrending. After that, time-domain, frequency-domain, non-linear HRV features are extracted from the pre-processed data in feature extraction stage. Then, these features are used as input to the SVM for predicting the PAF event. The proposed optimization algorithm is used to optimize the parameters and settings of various HRV feature extraction algorithms, select the best feature subsets, and tune the SVM parameters simultaneously for maximum prediction performance. The proposed method achieves an accuracy rate of 87.7%, which significantly outperforms most of the previous works. This accuracy rate is achieved even with the HRV signal length being reduced from the typical 30 min to just 5 min (a reduction of 83%). Furthermore, another significant result is the sensitivity rate, which is considered more important that other performance metrics in this paper, can be improved with the trade-off of lower specificity.
    Matched MeSH terms: Electrocardiography
  10. Ibrahim, N.U.A., Abd Aziz, S., Nawi, N.M.
    MyJurnal
    Soluble solid content (SSC) is one of the important traits that indicate the ripeness of banana fruits.
    Determination of SSC for banana often requires destructive laboratory analysis on the fruit. An impedance measurement technique was investigated as a non-destructive approach for SSC determination of bananas. A pair of electrocardiogram (ECG) electrode connected to an impedance analyser board was used to measure the impedance value of bananas over the frequency of 19.5 to 20.5 KHz. The SSC measurement was conducted using a pocket refractometer and data was analysed to correlate SSC with impedance values. It was found that the mean of impedance, Z decreased from 10.01 to 99.93 KΩ at the frequency of 20 KHz, while the mean value of SSC increased from 0.58 to 4.93 % Brix from day 1 to day 8. The best correlation between impedance and SSC was found at 20 KHz, with the coefficient of determination, R2 of 0.87. This result indicates the potential of impedance measurement in predicting SSC of banana fruits.
    Matched MeSH terms: Electrocardiography
  11. Nizam Y, Mohd MNH, Jamil MMA
    Sensors (Basel), 2018 Jul 13;18(7).
    PMID: 30011823 DOI: 10.3390/s18072260
    Unintentional falls are a major public health concern for many communities, especially with aging populations. There are various approaches used to classify human activities for fall detection. Related studies have employed wearable, non-invasive sensors, video cameras and depth sensor-based approaches to develop such monitoring systems. The proposed approach in this study uses a depth sensor and employs a unique procedure which identifies the fall risk levels to adapt the algorithm for different people with their physical strength to withstand falls. The inclusion of the fall risk level identification, further enhanced and improved the accuracy of the fall detection. The experimental results showed promising performance in adapting the algorithm for people with different fall risk levels for fall detection.
    Matched MeSH terms: Electrocardiography
  12. Wu M, Lu Y, Yang W, Wong SY
    Front Comput Neurosci, 2020;14:564015.
    PMID: 33469423 DOI: 10.3389/fncom.2020.564015
    Cardiovascular diseases (CVDs) are the leading cause of death today. The current identification method of the diseases is analyzing the Electrocardiogram (ECG), which is a medical monitoring technology recording cardiac activity. Unfortunately, looking for experts to analyze a large amount of ECG data consumes too many medical resources. Therefore, the method of identifying ECG characteristics based on machine learning has gradually become prevalent. However, there are some drawbacks to these typical methods, requiring manual feature recognition, complex models, and long training time. This paper proposes a robust and efficient 12-layer deep one-dimensional convolutional neural network on classifying the five micro-classes of heartbeat types in the MIT- BIH Arrhythmia database. The five types of heartbeat features are classified, and wavelet self-adaptive threshold denoising method is used in the experiments. Compared with BP neural network, random forest, and other CNN networks, the results show that the model proposed in this paper has better performance in accuracy, sensitivity, robustness, and anti-noise capability. Its accurate classification effectively saves medical resources, which has a positive effect on clinical practice.
    Matched MeSH terms: Electrocardiography
  13. Yeap TB, Teah MK, Thevarajah S, Azerai S
    BMJ Case Rep, 2021 Mar 25;14(3).
    PMID: 33766970 DOI: 10.1136/bcr-2020-241176
    Wolff-Parkinson-White (WPW) syndrome is an extremely rare congenital cardiac conduction disorder. It is due to an aberrant pathway between the atrium and ventricle. This manuscript entails a man with an underlying WPW who was posted for an elective orchidectomy. We discussed the important perioperative precautions to prevent the precipitation of acute cardiac events.
    Matched MeSH terms: Electrocardiography
  14. Kaisbain N, Lim WJ, Kim HS
    BMJ Case Rep, 2021 Jul 27;14(7).
    PMID: 34315750 DOI: 10.1136/bcr-2021-244180
    Atrial septal defect (ASD) is the most common congenital heart disease observed in adult. Several ECG findings are considered sensitive for the diagnosis of ASD. We describe a 50 years old man who displayed Crochetage sign, incomplete right bundle branch block (IRBBB) and right ventricular strain pattern on ECG. Crochetage sign is highly specific for ASD and it correlates with shunt severity. The diagnostic specificity for ASD increases if the R waves have both Crochetage patterns and IRBBB. It is important not to confuse Crochetage signs with IRBBB abnormalities on ECG. Our patient was ultimately diagnosed with a large ASD measuring 3 cm with bidirectional shunt and concomitant pulmonary thrombosis. This illustrates that high suspicion of the ASD with the use of good-old ECG signs remains relevant in this modern era. This also reminds us that patients with Eisenmenger syndrome are at higher risk for pulmonary thrombosis.
    Matched MeSH terms: Electrocardiography
  15. Hussein AF, Hashim SJ, Rokhani FZ, Wan Adnan WA
    Sensors (Basel), 2021 Mar 26;21(7).
    PMID: 33810211 DOI: 10.3390/s21072311
    Cardiovascular Disease (CVD) is a primary cause of heart problems such as angina and myocardial ischemia. The detection of the stage of CVD is vital for the prevention of medical complications related to the heart, as they can lead to heart muscle death (known as myocardial infarction). The electrocardiogram (ECG) reflects these cardiac condition changes as electrical signals. However, an accurate interpretation of these waveforms still calls for the expertise of an experienced cardiologist. Several algorithms have been developed to overcome issues in this area. In this study, a new scheme for myocardial ischemia detection with multi-lead long-interval ECG is proposed. This scheme involves an observation of the changes in ischemic-related ECG components (ST segment and PR segment) by way of the Choi-Williams time-frequency distribution to extract ST and PR features. These extracted features are mapped to a multi-class SVM classifier for training in the detection of unknown conditions to determine if they are normal or ischemic. The use of multi-lead ECG for classification and 1 min intervals instead of beats or frames contributes to improved detection performance. The classification process uses the data of 92 normal and 266 patients from four different databases. The proposed scheme delivered an overall result with 99.09% accuracy, 99.49% sensitivity, and 98.44% specificity. The high degree of classification accuracy for the different and unknown data sources used in this study reflects the flexibility, validity, and reliability of this proposed scheme. Additionally, this scheme can assist cardiologists in detecting signal abnormality with robustness and precision, and can even be used for home screening systems to provide rapid evaluation in emergency cases.
    Matched MeSH terms: Electrocardiography
  16. Nayan NA, Ab Hamid H, Suboh MZ, Abdullah N, Jaafar R, Mhd Yusof NA, et al.
    DOI: 10.3991/ijoe.v16i07.13569
    Cardiovascular disease (CVD) is the leading cause of deaths worldwide. In 2017, CVD contributed to 13,503 deaths in Malaysia. The current approaches for CVD prediction are usually invasive and costly. Machine learning (ML) techniques allow an accurate prediction by utilizing the complex interactions among relevant risk factors. This study presents a case–control study involving 60 participants from The Malaysian Cohort, which is a prospective population-based project. Five parameters, namely, the R–R interval and root mean square of successive differences extracted from electrocardiogram (ECG), systolic and diastolic blood pressures, and total cholesterol level, were statistically significant in predicting CVD. Six ML algorithms, namely, linear discriminant analysis, linear and quadratic support vector machines, decision tree, knearest neighbor, and artificial neural network (ANN), were evaluated to determine the most accurate classifier in predicting CVD risk. ANN, which achieved 90% specificity, 90% sensitivity, and 90% accuracy, demonstrated the highest prediction performance among the six algorithms. In summary, by utilizing ML techniques, ECG data can serve as a good parameter for CVD prediction among the Malaysian multiethnic population.
    Keywords—CVD, ECG, machine learning, The Malaysian Cohort, RMSSD
    Study name: The Malaysian Cohort (TMC) project
    Matched MeSH terms: Electrocardiography
  17. Loh HW, Ooi CP, Oh SL, Barua PD, Tan YR, Molinari F, et al.
    Comput Methods Programs Biomed, 2023 Nov;241:107775.
    PMID: 37651817 DOI: 10.1016/j.cmpb.2023.107775
    BACKGROUND AND OBJECTIVE: Attention Deficit Hyperactivity problem (ADHD) is a common neurodevelopment problem in children and adolescents that can lead to long-term challenges in life outcomes if left untreated. Also, ADHD is frequently associated with Conduct Disorder (CD), and multiple research have found similarities in clinical signs and behavioral symptoms between both diseases, making differentiation between ADHD, ADHD comorbid with CD (ADHD+CD), and CD a subjective diagnosis. Therefore, the goal of this pilot study is to create the first explainable deep learning (DL) model for objective ECG-based ADHD/CD diagnosis as having an objective biomarker may improve diagnostic accuracy.

    METHODS: The dataset used in this study consist of ECG data collected from 45 ADHD, 62 ADHD+CD, and 16 CD patients at the Child Guidance Clinic in Singapore. The ECG data were segmented into 2 s epochs and directly used to train our 1-dimensional (1D) convolutional neural network (CNN) model.

    RESULTS: The proposed model yielded 96.04% classification accuracy, 96.26% precision, 95.99% sensitivity, and 96.11% F1-score. The Gradient-weighted class activation mapping (Grad-CAM) function was also used to highlight the important ECG characteristics at specific time points that most impact the classification score.

    CONCLUSION: In addition to achieving model performance results with our suggested DL method, Grad-CAM's implementation also offers vital temporal data that clinicians and other mental healthcare professionals can use to make wise medical judgments. We hope that by conducting this pilot study, we will be able to encourage larger-scale research with a larger biosignal dataset. Hence allowing biosignal-based computer-aided diagnostic (CAD) tools to be implemented in healthcare and ambulatory settings, as ECG can be easily obtained via wearable devices such as smartwatches.

    Matched MeSH terms: Electrocardiography
  18. Yildirim O, Baloglu UB, Tan RS, Ciaccio EJ, Acharya UR
    Comput Methods Programs Biomed, 2019 Jul;176:121-133.
    PMID: 31200900 DOI: 10.1016/j.cmpb.2019.05.004
    BACKGROUND AND OBJECTIVE: For diagnosis of arrhythmic heart problems, electrocardiogram (ECG) signals should be recorded and monitored. The long-term signal records obtained are analyzed by expert cardiologists. Devices such as the Holter monitor have limited hardware capabilities. For improved diagnostic capacity, it would be helpful to detect arrhythmic signals automatically. In this study, a novel approach is presented as a candidate solution for these issues.

    METHODS: A convolutional auto-encoder (CAE) based nonlinear compression structure is implemented to reduce the signal size of arrhythmic beats. Long-short term memory (LSTM) classifiers are employed to automatically recognize arrhythmias using ECG features, which are deeply coded with the CAE network.

    RESULTS: Based upon the coded ECG signals, both storage requirement and classification time were considerably reduced. In experimental studies conducted with the MIT-BIH arrhythmia database, ECG signals were compressed by an average 0.70% percentage root mean square difference (PRD) rate, and an accuracy of over 99.0% was observed.

    CONCLUSIONS: One of the significant contributions of this study is that the proposed approach can significantly reduce time duration when using LSTM networks for data analysis. Thus, a novel and effective approach was proposed for both ECG signal compression, and their high-performance automatic recognition, with very low computational cost.

    Matched MeSH terms: Electrocardiography/methods*; Electrocardiography, Ambulatory
  19. Sabarudin A, Sun Z, Yusof AK
    Int J Cardiol, 2013 Sep 30;168(2):746-53.
    PMID: 23098849 DOI: 10.1016/j.ijcard.2012.09.217
    This study is conducted to investigate and compare image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated coronary CT angiography (CCTA) with the use of single-source CT (SSCT) and dual-source CT (DSCT).
    Matched MeSH terms: Electrocardiography/methods; Electrocardiography/standards*
  20. Khalil A, Faisal A, Ng SC, Liew YM, Lai KW
    J Med Imaging (Bellingham), 2017 Jul;4(3):037001.
    PMID: 28840172 DOI: 10.1117/1.JMI.4.3.037001
    A registration method to fuse two-dimensional (2-D) echocardiography images with cardiac computed tomography (CT) volume is presented. The method consists of two major procedures: temporal and spatial registrations. In temporal registration, the echocardiography frames at similar cardiac phases as the CT volume were interpolated based on electrocardiogram signal information, and the noise of the echocardiography image was reduced using the speckle reducing anisotropic diffusion technique. For spatial registration, an intensity-based normalized mutual information method was applied with a pattern search optimization algorithm to produce an interpolated cardiac CT image. The proposed registration framework does not require optical tracking information. Dice coefficient and Hausdorff distance for the left atrium assessments were [Formula: see text] and [Formula: see text], respectively; for left ventricle, they were [Formula: see text] and [Formula: see text], respectively. There was no significant difference in the mitral valve annulus diameter measurement between the manually and automatically registered CT images. The transformation parameters showed small deviations ([Formula: see text] deviation in translation and [Formula: see text] for rotation) between manual and automatic registrations. The proposed method aids the physician in diagnosing mitral valve disease as well as provides surgical guidance during the treatment procedure.
    Matched MeSH terms: Electrocardiography
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links