Displaying publications 41 - 60 of 98 in total

Abstract:
Sort:
  1. Ng K, Pirabul R, Peralta A, Soejoko D
    Australas Phys Eng Sci Med, 1997 Mar;20(1):27-32.
    PMID: 9141310
    In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of lack of recognition, low salaries, and insufficient facilities for education and training opportunities. However the situation has improved recently through the initiative of local enthusiastic medical physicists who have started MS graduate programs in medical physics and begun organizing professional activities to raise the profile of medical physics. The tremendous support and catalytic roles of the American Association of Physicists in Medicine (AAPM) and international organizations such as International Organization for Medical Physics (IOMP), International Atomic Energy Agency (IAEA), World Health Organization (WHO), and International Center for Theoretical Physics (ICTP) have been instrumental in achieving progress. Contributions by these organizations include co-sponsorship of workshops and conferences, travel grants, medical physics libraries programs, and providing experts and educators. The demand for medical physicists is expected to rise in tandem with the increased emphasis on innovative technology for health care, stringent governmental regulation, and acceptance by the medical community of the important role of medical physicists.
    Matched MeSH terms: Radiology/education
  2. Wastie ML
    Med J Malaysia, 1994 Sep;49(3):199-204.
    PMID: 7845265
    Matched MeSH terms: Radiology/history*
  3. Luke HA
    Australas Radiol, 1970 Feb;14(1):15-9.
    PMID: 5525077
    Matched MeSH terms: Radiology/education*
  4. Nur Aishah Jusnaidi, Nurul Fadhlina Ismail
    MyJurnal
    Assessing the repeat rate is crucial to reduce unnecessary dose to the patient by identifying the major cause for repeating the x-rays exposure to the patient and apply corrective measures. To analyse the repeat rate of routine lower limb projections in direct digital radiography (DR) from general radiology department of Pantai Klang Hospital. 26 months retrospective repeated radiograph was acquired from Picture Archiving and Communication System (PACS) at Hospital Pantai Klang. The retrieved radiographs were grouped based on the reason for the i radiographs being rejected which are incorrect positioning, incorrect collimation, patient movement, incorrect exposure factors, artefact, and other reasons. Total repeated radiographs retrieved for basic lower limbs projections were 13616. Knee was the highest repeted examination and the lowest repeat rate was tibia fibula. (repeat rate: knee = 1.04%, tibia fibula = 0.57%). incorrect positioning is the major causes for repeat exposure for all examinations type, followed by incorrect collimation, other categories, centring ray error, incorrect exposure factors and artifact.
    Matched MeSH terms: Radiology; Radiology Information Systems
  5. Dugdale AE
    Med J Aust, 1970 Dec 5;2(23):1087-91.
    PMID: 5491085
    Matched MeSH terms: Radiology/manpower
  6. Radhiana H, Siti Kamariah CM, Mohd Nazli K, Azian AA
    Med J Malaysia, 2014 Feb;69(1):46-8.
    PMID: 24814633 MyJurnal
    The wide use of computed tomography (CT) scanning for patients with blunt abdominal trauma can reveal incidental findings that vary in their importance. We evaluated these findings, how it was reported by radiologists and its implication on the trauma care. In 30 out of 154 patients, 32 incidental findings were discovered (19.5%). Out of these 32 findings, only 3 cases (9.4%) were considered significant and required immediate attention from the managing team. In all these 3 cases, the findings were described in the body of the report and highlighted in the conclusion section at the end of the radiology report. However, similar reporting style was used in only 58.4% of cases with moderate clinical concern and 23.5% of cases with little clinical concern. In 41.2% of cases with little concern, the incidental findings were not mentioned in the radiology report. In conclusion, incidental findings in CT scan performed for blunt abdominal trauma were common but many were clinically insignificant. There is little consistency in radiology reporting of these findings especially those with moderate and little clinical concern.
    Matched MeSH terms: Radiology
  7. Qurash MT, Yaacob NY, Azuan N, Khaleel YS, Zakaria R
    J Med Ultrasound, 2018 06 18;26(4):210-214.
    PMID: 30662153 DOI: 10.4103/JMU.JMU_40_18
    Interventional radiology procedures are becoming more challenging over time; thus, there is a need for excellent and reliable training methods. Training on live patients is neither safe nor an ethical solution. Alternatives are many and varied, but the most popular is ultrasound guided simulators. This report shows how a simple, homemade, low-cost phantom material, and construction modules can provide several advantages over ordinary gelatin phantoms. A new layering technique and target synthesis are described for the biopsy phantom, including tips on decreasing the needle pass artifact as well as controlling the mixture echogenicity.
    Matched MeSH terms: Radiology, Interventional
  8. Purmal, Kathiravan, Nambiar, Phrabhakaran
    Malaysian Dental Journal, 2008;29(2):104-112.
    MyJurnal
    Radiology is important in the diagnostic assessment, treatment and monitoring progress of patients having dental and maxillofacial diseases. The central question in dental radiology is whether there is any risk with regard to low doses of radiation and what are the necessary protection needed to prevent any hazardous outcome with X-raying. With the emergence of the new millennium, major changes are happening in the field of science and technology. More efficient equipments are being discovered and more researches are being conducted to elicit better understanding of the radiation process and its effect on the human health. This article will review the latest guidelines for proper radiographic practice from the USA and Europe. It will address topics like the risks from dental radiography, selection criteria, protection for patients and staff, improvement to X-ray equipments, room dimensions and lead lining requirements. We have limited our research to intraoral, panoramic and cephalometric radiographs because these are the radiographs or images that are commonly taken in the general practice setting. (Copied from article).
    Matched MeSH terms: Radiology
  9. Kadhim Jawad Obaid
    Int J Public Health Res, 2011;1(2):41-49.
    MyJurnal
    A prospective study done In al Zaafaranya General Hospital in Baghdad/Iraq In the period between April 2003 and February 2007. Ninety two patients admitted to the surgical wards diagnosed as Intestinal obstruction. The aim is to find out the possible common conditions resulting in causing this common surgical emergency. Also to compare the provisional clinical diagnosis about ischemic obstruction and the definitive post operative diagnosis. To encourage post graduate students to use their clinical abilities with the few laboratory and radiological facilities available needed to decide about the management of those patients.
    Matched MeSH terms: Radiology
  10. Basri JJA
    JUMMEC, 2002;7:44-45.
    A survey was done to assess the chest radiographs of a selected group of immigrants. The objective is to ascertain the rpesence of abnormalities especially the presence of tuberculosis. Five hundred and eleven (511) chest radiographs (PA view) were evaluated. majority of the chest radiographs were normal, except for 2 cases of hilar lymphadenopathy, 4 cases of scoliosis and cervical rib, an old case of fracture of the clavicle and a case of cardiomegaly. Only 2 cases of TB were detected.
    Matched MeSH terms: Radiology
  11. Safari MJ, Wong JH, Ng KH, Jong WL, Cutajar DL, Rosenfeld AB
    Med Phys, 2015 May;42(5):2550-8.
    PMID: 25979047 DOI: 10.1118/1.4918576
    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures.
    Matched MeSH terms: Radiology, Interventional/instrumentation*; Radiology, Interventional/methods*
  12. Safari MJ, Wong JHD, Jong WL, Thorpe N, Cutajar D, Rosenfeld A, et al.
    Phys Med, 2017 Mar;35:66-72.
    PMID: 28256398 DOI: 10.1016/j.ejmp.2017.02.002
    PURPOSE: The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures.

    METHODS: We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors.

    RESULTS: DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region.

    CONCLUSION: Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures.

    Matched MeSH terms: Radiology, Interventional/instrumentation; Radiology, Interventional/methods*
  13. Rohana J, Boo NY, Yong SC, Ong LC
    Med J Malaysia, 2005 Aug;60(3):338-44.
    PMID: 16379189 MyJurnal
    A quality assurance study was carried out prospectively in two phases at the Neonatal Intensive Care Unit (NICU) of Hospital Universiti Kebangsaan Malaysia. The objectives of the study were to determine the turn-around-time (TAT) of radiographs requested for infants undergoing intensive care treatment in the NICU and the effects of a standard operating procedure introduced based on initial findings of first phase of the study on subsequent TAT. The TAT was defined as the time taken for the radiograph to be ready for viewing after the attending doctor had requested for it to be done on an infant. During phase one of the study, none of the requested radiographs was ready to be viewed by the doctors within the standard TAT of 45 minutes. The problems identified were ward staffs delay in sending request forms to the radiology department, radiographers' delay in shooting and processing the films, and delay by NICU porter in collecting the processed films. Based on these findings, a standard operating procedure (SOP) was drawn up jointly by the staff of NICU and Department of Radiology. During phase two of the study conducted at one month after implementation of the SOP, there was a reduction of TAT by 50%. However, only 3 (4.3%) of the radiographs achieved the standard TAT. The main problems identified during phase two were delay in sending request forms and in collecting processed radiographs by the porter system. The dismal TAT of radiographs in NICU was related primarily to human behaviour. Besides continuous staff education, replacement of the porter system with electronic system may improve the TAT.
    Keywords: Turn-around time, radiographs, neonatal intensive care unit, standard operating procedure, Kuala Lumpur
    Matched MeSH terms: Radiology Department, Hospital/organization & administration*; Radiology Department, Hospital/standards*
  14. Duc NM, Huy HQ, Keserci B, Thong PM
    Med Arch, 2020 Feb;74(1):42-46.
    PMID: 32317834 DOI: 10.5455/medarh.2020.74.42-46
    Introduction: Each country has its system of the training program, but to be concordant with the world in the radiology field, the process needs to have common points or common criteria. On maintaining the integrity of intersociety collaboration in the field of radiology, it is necessary to understand each country's training program for each specialty.

    Aim: This retrospective study aims to compare the postgraduate thesis characteristics from various sources in the field of radiology.

    Methods: This was a retrospective study evaluating data that is publicly available online and at libraries and institutional review board approval, as such, was not demanded. We selected 40 published theses from the library of Pham Ngoc Thach University of Medicine and University of Medicine and Pharmacy at Ho Chi Minh City and Hanoi Medical University in Vietnam which graduated from 2008 to 2018. Of these, there were 10 PhD, 10 specialists II, 10 master's, and 10 residency theses selected.

    Results: A total of 40 theses were analyzed from participants with a median age of 36.5. The male/female ratio was 23/17. Most of the theses were subspecialty in diagnostic radiology (87.5%) and focused on pathological radiology (95%). Adult patients were the major objectives of the theses accounted for 87.5% with predominant materials of magnetic resonance imaging counted for 47.5%. Theses in PhD group were the largest items regarding the total number of pages as well as the number of figures, and the number of references. Nonetheless, both domestic and international publications related to all theses were truly low.

    Conclusion: The postgraduate thesis of radiology in Vietnam has many different forms but mainly focuses on diagnostic and pathological radiology with materials of magnetic resonance imaging in adults. The number of international publications regarding the thesis was very small.

    Matched MeSH terms: Radiology/education*; Radiology/statistics & numerical data*
  15. Tan KP, Mohamad Azlan Z, Rumaisa MP, Siti Aisyah Murni MR, Radhika S, Nurismah MI, et al.
    Med J Malaysia, 2014 Apr;69(2):79-85.
    PMID: 25241817 MyJurnal
    AIM: This study was performed to determine the accuracy of ultrasound (USG) as compared to mammography (MMG) in detecting breast cancer.

    METHODS: This was a review of patients who had breast imaging and biopsy during an 18-month period. Details of patients who underwent breast biopsy were obtained from the department biopsy record books and imaging request forms. Details of breast imaging findings and histology of lesions biopsied were obtained from the hospital Integrated Radiology Information System (IRIS). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of USG and MMG were calculated with histology as the gold standard.

    RESULTS: A total of 326 breast lesions were biopsied. Histology results revealed the presence of 74 breast cancers and 252 benign lesions. USG had a sensitivity of 82%, specificity of 84%, PPV = 60%, NPV = 94% and an accuracy of 84%. MMG had a sensitivity of 49%, specificity of 89%, PPV = 53%, NPV = 88% and an accuracy of 81%. A total of 161 lesions which were imaged with both modalities were analyzed to determine the significance in the differences in sensitivity and specificity between USG and MMG. Sensitivity of USG (75%) was significantly higher than sensitivity of MMG (44%) (X(2)1=6.905, p=0.014). Specificity of MMG (91%) was significantly higher than specificity of USG (79%) (X(2)1=27.114, p<0.001). Compared with MMG, the sensitivity of USG was 50% (95% CI 10%-90%) higher in women aged less than 50 years (X(2)1=0.000, p=1.000) and 27% (95% CI 19%-36%) higher in women aged 50 years and above (X(2)1=5.866, p=0.015). Compared with MMG, the sensitivity of USG was 40% (95% CI 10%-70%) higher in women with dense breasts (X(2)1=0.234, p=0.628) and 27% (95% CI 9%-46%) higher in women with non-dense breasts (X(2)1=4.585, p=0.032).

    CONCLUSION: Accuracy of USG was higher compared with MMG. USG was more sensitive than MMG regardless of age group. However, MMG was more specific in those aged 50 years and older. USG was more sensitive and MMG was more specific regardless of breast density. In this study, 20% of breast cancers detected were occult on MMG and seen only on USG.
    Matched MeSH terms: Radiology Information Systems
  16. Ho E
    Biomed Imaging Interv J, 2008 Oct;4(4):e20.
    PMID: 21611012 MyJurnal DOI: 10.2349/biij.4.1.e20
    Convention dictates that standards are a necessity rather than a luxury. Standards are supposed to improve the exchange of health and image data information resulting in improved quality and efficiency of patient care. True standardisation is some time away yet, as barriers exist with evolving equipment, storage formats and even the standards themselves. The explosive growth in the size and complexity of images such as those generated by multislice computed tomography have driven the need for digital image management, created problems of storage space and costs, and created a challenge for increasing or getting an adequate speed for transmitting, accessing and retrieving the image data. The search for a suitable and practical format for storing the data without loss of information and medico-legal implications has become a necessity and a matter of 'urgency'. Existing standards are either open or proprietary and must comply with local, regional or national laws. Currently there are the Picture Archiving and Communications System (PACS); Digital Imaging and Communications in Medicine (DICOM); Health Level 7 (HL7) and Integrating the Healthcare Enterprise (IHE). Issues in digital image management can be categorised as operational, procedural, technical and administrative. Standards must stay focussed on the ultimate goal - that is, improved patient care worldwide.
    Matched MeSH terms: Radiology Information Systems
  17. Ho E, Abdullah B, Tang A, Nordin A, Nair A, Lim G, et al.
    Biomed Imaging Interv J, 2008 Oct;4(4):e44.
    PMID: 21611021 DOI: 10.2349/biij.4.4.e44
    To date, the College of Radiology (CoR) does not see any clear benefit in performing whole body screening computed tomography (CT) examinations in healthy asymptomatic individuals. There are radiation risk issues in CT and principles of screening should be adhered to. There may be a role for targeted cardiac screening CT that derives calcium score, especially for asymptomatic medium-risk individuals and CT colonography when used as part of a strategic programme for colorectal cancer screening in those 50 years and older. However, population based screening CT examinations may become appropriate when evidence emerges regarding a clear benefit for the patient outweighing the associated radiation risks.
    Matched MeSH terms: Radiology
  18. Abdullah B
    Biomed Imaging Interv J, 2006 Oct;2(4):e28.
    PMID: 21614327 MyJurnal DOI: 10.2349/biij.2.4.e28
    Predicting the future is a dangerous undertaking at best, and not meant for the faint-hearted. However, viewing the advances in molecular medicine, genomics and proteomics, it is easy to comprehend those who believe that molecular imaging methods will open up new vistas for medical imaging. The knock on effect will impact our capacity to diagnose and treat diseases. Anatomically detectable abnormalities, which have historically been the basis of the practice of radiology, will soon be replaced by molecular imaging methods that will reflect the under expression or over expression of certain genes which occur in almost every disease. Molecular imaging can then be resorted to so that early diagnosis and characterisation of disease can offer improved specificity. Given the growing importance of molecular medicine, imagers will find it profitable to educate themselves on molecular targeting, molecular therapeutics and the role of imaging in both areas.
    Matched MeSH terms: Radiology
  19. Ying, C.K., W.A. Kamil, Matsufuji, Naruhiro
    MyJurnal
    Charged particle therapy with carbon ions has advantages over conventional radiotherapy using x-ray beams. The application of charged particle therapy has rapidly increased over the last decades. This is due to its characteristic Bragg peak which has relatively low entrance doses and favourable doses distribution. In this research work, Geant4 based Monte Carlo simulation (MC) method has been used to calculate the radiation transportation and dose distributions in tissue-like media. The main objective of the work was to compare the Geant4 simulated depth dose distributions with experimental measurements and verify the capability of the geant4 simulation toolkit. The carbon ion beams for the therapeutic energy of 350 MeV/u and 400 MeV/u respectively were simulated, with the same settings as the experimental work carried out at the treatment room at Heavy Ion Medical Accelerator (HIMAC), National Institute of Radiological Sciences (NIRS), Chiba, Japan. The simulation results were verified with measurements data. The work was to measure the accuracy and quality of the dose distributions by Geant4 MC methods. The results show that the Bragg peak and spread out Bragg peak (SOBP) distributions in simulation has fairly good agreement with measurements.
    Matched MeSH terms: Radiology