DESIGN: Prospective analysis of all ocular trauma injuries presenting to the Department of Ophthalmology in UMMC from 1 January 2008 to 31 December 2008.
PARTICIPANTS: A total of 603 eyes of 546 patients were recruited for the study.
METHODS: All patients presenting to the department with ocular trauma injuries were assessed by an ophthalmologist. Data on the type and source of injury, demographic profile of the patients, and clinical presentation were documented using a uniform and validated datasheet.
RESULTS: Among eye injury cases, 481 patients (88.1%) were male, with a male-to-female ratio of 7.4:1. Of the patients, 412 (75.5%) were Malaysian while the remaining 134 (24.5%) were of non-Malaysian nationality. The average age was 31.5 years (range 1-81 years). A total of 238 injured eyes (43.6%) were work-related. The common sources of eye trauma include the use of high-powered tools (30.8%), motor vehicle accident (23.1%), and domestic accidents (17.7%). Only six patients (2.5%) reported to having used eye protective device (EPD) at time of their work-related injuries.
CONCLUSIONS: A major cause of preventable ocular injuries in Malaysia was work-related trauma. Ocular injuries can be reduced by the use of eye protection devices and the implementation of appropriate preventive strategies to address each risk factor. Effective training is an integral part of occupational safety and health, which should be made mandatory at the workplace. In addition, there should be a continual assessment of safety and health issues at the workplace. A long-term database of all ocular injuries in Malaysia is recommended, to aid research on a larger scale and the development of new preventive strategies for ocular injuries.
METHODS: It was a retrospective study carried out in a Level 1 arthroplasty and trauma centre. 23 patients (17 males, 6 females) with average age of 50.1 years (range, 36-68 years) with displaced acetabular fracture treated with combined incisions and plate-cable systems were included. There were 3 elementary and 18 associated fractures according to Letournel classification. Average follow-up was 23.5 months (range, 12-38.7 months). Mean operation time was 160min (range: 75-320min). Functional scores were evaluated using Harris Hip Score (HHS) whilst reduction was assessed by Matta criteria. Any displacement of reduction, osteoarthritis, heterotopic ossification, and other complications was recorded.
RESULT: 65.2% (15/23) of the patients obtained excellent HHS and 21.7% (5/23) had good HHS. There were 12 anatomical, 6 imperfect, and 5 poor reductions. No displacement was recorded in final follow-up. Complications documented: three lateral femoral cutaneous nerve injuries, two conversions to total hip arthroplasty, three Brooker stage 1 heterotrophic ossification, one pulmonary embolism and one screw irritation. No incidence of wound breakdown, infection and radiological osteoarthritis was reported.
CONCLUSIONS: Imperfect reduction of the anterior column provided clinical outcomes that are as good as total anatomical reduction. This approach minimizes soft tissue damage and reduces perioperative morbidities.
METHODS: We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors.
RESULTS: DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region.
CONCLUSION: Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures.
METHODS: This was a cross-sectional study involving 195 women enrolled in a longitudinal cohort study and seen 20 years after an index birth. All had a standardized patient-administered questionnaire, the International Continence Society Pelvic Organ Prolapse Quantification assessment and 4D translabial ultrasound. Main outcome measures were objective POP clinically and on translabial ultrasound. Postimaging assessment of levator integrity and sonographically determined pelvic organ descent was done blinded against other data.
RESULTS: Of 195 women who were seen a mean of 23 (range, 19.4-46.2) years after their first birth, one declined ultrasound assessment and was excluded, leaving 194. Mean age was 50.2 (range 36.9-66.5) years with a mean body mass index (BMI) of 27.6 (range, 18.3-54.3) kg/m2 . Median parity was 3 (range 1-14). Ninety-one percent (n = 176) had delivered vaginally. Eighteen percent (n = 34) were symptomatic of prolapse. Clinically, 36% (n = 69) had significant POP. Levator avulsion was diagnosed in 16% (n = 31). Mean levator avulsion defect score was 2.2 (range, 0-12). On univariate analysis, levator avulsion and levator avulsion defect score were associated with clinically and sonographically significant POP, that is, odds ratio 2.6 (1.2-5.7), P = .01; and odds ratio 3.3 (1.4-7.7); P = .003, respectively; Ba (P
OBJECTIVE: To determine whether knee sleeves can significantly improve the biomechanical variables for knee problems.
METHOD: Systematic literature search was conducted on four online databases - PubMed, Web of Science, ScienceDirect and Springer Link - to find peer-reviewed and relevant scientific papers on knee sleeves published from January 2005 to January 2015. Study quality was assessed using the Structured Effectiveness Quality Evaluation Scale (SEQES).
RESULTS: Twenty studies on knee sleeves usage identified from the search were included in the review because of their heterogeneous scope of coverage. Twelve studies found significant improvement in gait parameters (3) and functional parameters (9), while eight studies did not find any significant effects of knee sleeves usage.
CONCLUSION: Most improvements were observed in: proprioception for healthy knees, gait and balance for osteoarthritic knees, and functional improvement of injured knees. This review suggests that knee sleeves can effect functional improvements to knee problems. However, further work is needed to confirm this hypothesis, due to the lack of homogeneity and rigor of existing studies.
METHOD: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion.
RESULTS: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group.
CONCLUSION: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.
METHODS: Retrospective chart review that evaluates all trauma patients which required immediate operative intervention from January 2011 to December 2015. Trauma patients were selected from the resuscitation log book and data were collected by chart review of selected patients.
RESULTS: Only 5 out of 279 patients (1.8%) achieved optimal door to OT time. (<60 minutes) Mean door to OT time was 299.27 minutes (95% CI: 280.52, 318.52). Trauma team activation has shown significant improvement in door to OT time (p=0.047). Time of multiple team referrals (p=0.023) and time of operative decision (p<0.001) both had significant impact on door to OT time. Other factors included were demographics, ISS score, Glasgow Coma Scale (GCS), mechanism of injury and systolic blood pressure on arrival all which showed no significance.
CONCLUSION: Trauma team activation in a tertiary centre improved trauma care by reducing door to OT time to less than 60 minutes. Implementation of an effective trauma team activation system in all hospitals throughout Malaysia is recommended.
METHODS: Two blinded assessors examined thirty-five patients with a history of recent lateral ankle sprain. The first assessor performed physical examination on the injured ankle by using the anterior drawer test and talar tilt test, and the second assessor performed dynamic and static ultrasound assessment for anterior talofibular ligament and calcaneofibular ligament. The clinical laxity grading and sonographic extent of ligamentous injury was graded into a three-point scale.
RESULTS: There was a moderate positive correlation between clinical test and ultrasound grading of anterior talofibular ligament and calcaneofibular ligament with Spearman's correlation coefficient values of 0.58 and 0.66 respectively. Clinical grading of anterior drawer test had 59.1% sensitivity (95% CI: 0.36-0.79) while ultrasound grading had 100.0% specificity (95% CI: 0.75-1.00), with positive likelihood ratio of 0.77 and negative likelihood ratio of 0.44 in detecting a complete (grade 3) anterior talofibular ligament tear (P<0.05). Meanwhile, the clinical grading of talar tilt test had 54.5% sensitivity (95% CI: 0.23-0.83) and ultrasound grading had 100.0% specificity (95% CI: 0.85-1.00), with positive likelihood ratio of 1.0 and negative likelihood ratio of 0.45 in detecting a complete grade 3 calcaneofibular ligament tear (P<0.05).
CONCLUSIONS: The dynamic ultrasound is recommended to determine the actual degree of disruption of the ligament especially when clinical grading under-grades the degree of tear. Grade 2 tears can vary from 10% tear to 90% tear causing the clinical correlation to become less strong. We recommend a new classification for ultrasound grading of grade 2 tears, which could result in a stronger correlation between clinical and ultrasound grading.
Material and Methods: Thirty-three patients with severe open tibial shaft fractures were managed using a standardised protocol of emergent debridement, external fixation and immediate wound cover with free distant/local rotational muscle flaps and fasciocutaneous flaps, and with vascular repair in Grade 3C fractures. Intra-articular fractures were excluded. Patients were followed for a minimum of three years, with an assessment of clinical, radiological and functional outcomes.
Results: Wound cover was achieved with 24 distant free muscle flaps, four local rotational muscle flaps and five fasciocutaneous flaps. All fractures united with an average time to union of 40.3 weeks (16-88). Fifteen patients (45.4%) underwent only a single major surgery using primary definitive external fixation. Deep infection was seen in four patients (12.1%). Nineteen patients had excellent to good outcomes, six were fair, and eight were poor.
Conclusion: "Fix and Flap" in the same sitting, using immediate wound cover and external fixation, has given good results in our hands despite the delayed presentation, the neurovascular deficit and the degloving injury. This may be a better management strategy in overcrowded tertiary care centres of developing countries, with a single surgical procedure in almost half the cases.