Displaying publications 61 - 80 of 98 in total

Abstract:
Sort:
  1. Ab Mumin N, Ramli Hamid MT, Wong JHD, Rahmat K, Ng KH
    Acad Radiol, 2022 Jan;29 Suppl 1:S89-S106.
    PMID: 34481705 DOI: 10.1016/j.acra.2021.07.017
    OBJECTIVE: Magnetic resonance imaging (MRI) is the most sensitive imaging modality in detecting breast cancer. The purpose of this systematic review is to investigate the role of human extracted MRI phenotypes in classifying molecular subtypes of breast cancer.

    METHODS: We performed a literature search of published articles on the application of MRI phenotypic features in invasive breast cancer molecular subtype classifications by radiologists' interpretation on Medline Complete, Pubmed, and Google scholar from 1st January 2000 to 31st March 2021. Of the 1453 literature identified, 42 fulfilled the inclusion criteria.

    RESULTS: All studies were case-controlled, retrospective study and research-based. The majority of the studies assessed the MRI features using American College of Radiology- Breast Imaging Reporting and Data System (ACR-BIRADS) classification and using dynamic contrast-enhanced (DCE) kinetic features, Apparent Diffusion Coefficient (ADC) values, and T2 sequence. Most studies divided invasive breast cancer into 4 main subtypes, luminal A, luminal B, HER2, and triple-negative (TN) cancers, and used 2 readers. We present a summary of the radiologists' extracted breast MRI phenotypical features and their correlating breast cancer subtypes classifications. The characteristic features are morphology, enhancement kinetics, and T2 signal intensity. We found that the TN subtype has the most distinctive MRI features compared to the other subtypes and luminal A and B have many similar features.

    CONCLUSION: The MRI features which are predictive of each subtype are the morphology, internal enhancement features, and T2 signal intensity, predominantly between TN and the rest. Radiologists' visual interpretation of some of MRI features may offer insight into the respective invasive breast cancer molecular subtype. However, current evidence are still limited to "suggestive" features instead of a diagnostic standard.  Further research is recommended to explore this potential application, for example, by augmentation of radiologists' visual interpretation by artificial intelligence.

  2. Tsapaki V, Ibbott G, Krisanachinda A, Ng KH, Suh TS, Tabakov S, et al.
    Phys Med, 2017 Dec;44:196-198.
    PMID: 29221890 DOI: 10.1016/j.ejmp.2017.11.022
    As medical technology evolves and patient needs increase, the need for well-trained and highly professional medical physicists (MPs) becomes even more urgent. The roles and responsibilities of MPs in various departments within the hospital are diverse and demanding. It is obvious that training, continuing education and professional development of MPs have become essential. One of the ways for an MP to advance his or her knowledge is to participate in conferences and congresses. Last year, the 22nd International Conference of Medical Physics (ICMP 2016) took place in Bangkok, Thailand. The event attracted 584 delegates with most of the participants coming from Asia. It attracted also delegates from 42 countries. The largest delegations were from Thailand, Japan and South Korea. ICMP 2016 included 367 oral presentations and e-posters, most of these being in the fields of Radiation Therapy, Medical Imaging and Radiation Safety. All abstracts were published as an e-book of Abstracts in a supplement to the official IOMP Journal. Many companies had exhibition stands at ICMP2016, thus allowing the participants to see the latest developments in the medical physics-related industry. The conference included 42 mini-symposia, part of the first "IOMP School" activity, covering various topics of importance for the profession and this special issue follows from the success of the conference.
  3. Acharya UR, Hagiwara Y, Sudarshan VK, Chan WY, Ng KH
    J Zhejiang Univ Sci B, 2018 1 9;19(1):6-24.
    PMID: 29308604 DOI: 10.1631/jzus.B1700260
    Radiology (imaging) and imaging-guided interventions, which provide multi-parametric morphologic and functional information, are playing an increasingly significant role in precision medicine. Radiologists are trained to understand the imaging phenotypes, transcribe those observations (phenotypes) to correlate with underlying diseases and to characterize the images. However, in order to understand and characterize the molecular phenotype (to obtain genomic information) of solid heterogeneous tumours, the advanced sequencing of those tissues using biopsy is required. Thus, radiologists image the tissues from various views and angles in order to have the complete image phenotypes, thereby acquiring a huge amount of data. Deriving meaningful details from all these radiological data becomes challenging and raises the big data issues. Therefore, interest in the application of radiomics has been growing in recent years as it has the potential to provide significant interpretive and predictive information for decision support. Radiomics is a combination of conventional computer-aided diagnosis, deep learning methods, and human skills, and thus can be used for quantitative characterization of tumour phenotypes. This paper discusses the overview of radiomics workflow, the results of various radiomics-based studies conducted using various radiological images such as computed tomography (CT), magnetic resonance imaging (MRI), and positron-emission tomography (PET), the challenges we are facing, and the potential contribution of radiomics towards precision medicine.
  4. Subramanian P, Choy KL, Gobal SV, Mansor M, Ng KH
    Singapore Med J, 2013 May;54(5):281-4.
    PMID: 23716155
    INTRODUCTION: Ventilator-associated pneumonia (VAP) is a common risk among critically ill ventilated patients. This study aimed to investigate the effects of nurse-led education on: (a) knowledge of and compliance with ventilator care bundle (VCB) practices among intensive care unit (ICU) nurses; and (b) reduction in the rates of VAP post intervention.

    METHODS: A quasi-experimental design with pretest-posttest evaluation and observation was used to investigate nurses' knowledge of and compliance with VCB practices, and the incidence of VAP. The study was conducted among 71 nurses, and the intervention involved structured education on VAP and its prevention using VCB in an ICU setting. Data were analysed using descriptive and inferential statistics.

    RESULTS: Nurse-led education significantly increased nurses' knowledge of (t[70] = -36.19; p < 0.001) and compliance with (t[65] = -21.41; p < 0.001) VCB practices. The incidence of VAP, which was 39 per 1,000 ventilator days during the two-month period before intervention, dropped to 15 per 1,000 ventilator days during the two-month period following intervention.

    CONCLUSION: Our findings show that nurse-led education on VAP and VCB significantly increased knowledge of and compliance with VCB practices among ICU nurses, and was associated with a reduction in the incidence of VAP among intubated and mechanically ventilated ICU patients. Inclusion of recent knowledge and evidence-based VCB guidelines for VAP prevention when educating anaesthetists, nurses, physiotherapists and other healthcare providers in the critical care setting is recommended.
  5. Sharif-Abdullah SS, Chong MC, Surindar-Kaur SS, Kamaruzzaman SB, Ng KH
    Singapore Med J, 2016 May;57(5):262-6.
    PMID: 27211885 DOI: 10.11622/smedj.2016091
    INTRODUCTION: Inadequate oral care has been implicated in the development of aspiration pneumonia in frail geriatric patients and is a major cause of mortality, due to the colonisation of microbes in vulnerable patients. This type of pneumonia has been associated with an increase in respiratory pathogens in the oral cavity. The aim of this study was to evaluate the effects of chlorhexidine compared to routine oral care in edentulous geriatric inpatients.

    METHODS: A double-blind, parallel-group randomised controlled trial was carried out. The intervention group received oral care with chlorhexidine 0.2%, while the control group received routine oral care with thymol. Nurses provided oral care with assigned solutions of 20 mL once daily over seven days. Oral cavity assessment using the Brief Oral Health Status Examination form was performed before each oral care procedure. Data on medication received and the subsequent development of aspiration pneumonia was recorded. An oral swab was performed on Day 7 to obtain specimens to test for colonisation.

    RESULTS: The final sample consisted of 35 (control) and 43 (intervention) patients. Chlorhexidine was effective in reducing oral colonisation compared to routine oral care with thymol (p < 0.001). The risk of oral bacterial colonisation was nearly three times higher in the thymol group compared to the chlorhexidine group.

    CONCLUSION: The use of chlorhexidine 0.2% significantly reduced oral colonisation and is recommended as an easier and more cost-effective alternative for oral hygiene.

  6. Zhu CZ, Ting HN, Ng KH, Mun KS, Ong TA
    Phys Eng Sci Med, 2024 Mar;47(1):61-71.
    PMID: 37843766 DOI: 10.1007/s13246-023-01341-5
    Many studies have investigated the dielectric properties of human and animal tissues, particularly to differentiate between normal cells and tumors. However, these studies are invasive as tissue samples have to be excised to measure the properties. This study aims to investigate the dielectric properties of urine in relation to bladder cancer, which is safe and non-invasive to patients. 30 healthy subjects and 30 bladder cancer patients were recruited. Their urine samples were subjected to urinalysis and cytology assessment. A vector network analyzer was used to measure the dielectric constant (Ɛ') and loss factor (Ɛ″) at microwave frequencies of between 0.2 and 50 GHz at 25 °C, 30 °C and 37 °C. Significant differences in Ɛ' and Ɛ″ were observed between healthy subjects and patients, especially at frequencies of between 25 and 40 GHz at 25 °C. Bladder cancer patients had significant lower Ɛ' and higher Ɛ″ compared with healthy subjects. The Ɛ' was negatively correlated with urinary exfoliated urothelial cell number, and Ɛ″ was positively correlated. The study achieved a receiver operating characteristic area under curve (ROC-AUC) score of 0.69099 and an optimum accuracy of 75% with a sensitivity of 80% and a specificity of 70%. The number of exfoliated urothelial cell had significant effect on the dielectric properties, especially in bladder cancer patients. Urinary dielectric properties could potentially be used as a tool to detect bladder cancer.
  7. Tan SK, Yeong CH, Ng KH, Abdul Aziz YF, Sun Z
    PLoS One, 2016;11(8):e0161543.
    PMID: 27552224 DOI: 10.1371/journal.pone.0161543
    OBJECTIVES: This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE).

    MATERIALS AND METHODS: Prospectively ECG-triggered CCTA was performed using five commercially available CT scanners: 64-detector-row single source CT (SSCT), 2 × 32-detector-row-dual source CT (DSCT), 2 × 64-detector-row DSCT and 320-detector-row SSCT scanners. Absorbed doses were measured in 34 organs using pre-calibrated optically stimulated luminescence dosimeters (OSLDs) placed inside a standard female adult anthropomorphic phantom. HE was calculated from the measured organ doses and compared to the HE derived from the air kerma-length product (PKL) using the conversion coefficient of 0.014 mSv∙mGy-1∙cm-1 for the chest region.

    RESULTS: Both breasts and lungs received the highest radiation dose during CCTA examination. The highest HE was received from 2 × 32-detector-row DSCT scanner (6.06 ± 0.72 mSv), followed by 64-detector-row SSCT (5.60 ± 0.68 and 5.02 ± 0.73 mSv), 2 × 64-detector-row DSCT (1.88 ± 0.25 mSv) and 320-detector-row SSCT (1.34 ± 0.48 mSv) scanners. HE calculated from the measured organ doses were about 38 to 53% higher than the HE derived from the PKL-to-HE conversion factor.

    CONCLUSION: The radiation doses received from a prospectively ECG-triggered CCTA are relatively small and are depending on the scanner technology and imaging protocols. HE as low as 1.34 and 1.88 mSv can be achieved in prospectively ECG-triggered CCTA using 320-detector-row SSCT and 2 × 64-detector-row DSCT scanners.

  8. Leong SS, Jalalonmuhali M, Md Shah MN, Ng KH, Vijayananthan A, Hisham R, et al.
    Br J Radiol, 2023 Mar 01;96(1144):20220288.
    PMID: 36802861 DOI: 10.1259/bjr.20220288
    OBJECTIVE: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allografts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable.

    METHODS: The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.

    RESULTS: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients.

    CONCLUSIONS: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful.

    ADVANCES IN KNOWLEDGE: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.

  9. Eturajulu RC, Tan MP, Zakaria MI, Chinna K, Ng KH
    Singapore Med J, 2023 Feb 06.
    PMID: 36751846 DOI: 10.4103/singaporemedj.SMJ-2021-254
    INTRODUCTION: Medical errors commonly occur in medical imaging departments. These errors are frequently influenced by patient safety culture. This study aimed to develop a suitable patient safety culture assessment tool for medical imaging departments.

    METHODS: Staff members of a teaching hospital medical imaging department were invited to complete the generic short version of the Safety Attitude Questionnaire (SAQ). Internal consistency and reliability were evaluated using Cronbach's α. Confirmatory factor analysis (CFA) was conducted to examine model fit. A cut-off of 60% was used to define the percentage positive responses (PPR). PPR values were compared between occupational groups.

    RESULTS: A total of 300 complete responses were received and the response rate was 75.4%. In reliability analysis, the Cronbach's α for the original 32-item SAQ was 0.941. Six subscales did not demonstrate good fit with CFA. A modified five-subscale, 22-item model (SAQ-MI) showed better fit (goodness-to-fit index ≥0.9, comparative fit index ≥ 0.9, Tucker-Lewis index ≥0.9 and root mean square error of approximation ≤0.08). The Cronbach's α for the 22 items was 0.921. The final five subscales were safety and teamwork climate, job satisfaction, stress recognition, perception of management and working condition, with PPR of 62%, 68%, 57%, 61% and 60%, respectively. Statistically significant differences in PPR were observed between radiographers, doctors and others occupational groups.

    CONCLUSION: The modified five-factor, 22-item SAQ-MI is a suitable tool for the evaluation of patient safety culture in a medical imaging department. Differences in patient safety culture exist between occupation groups, which will inform future intervention studies.

  10. Ab Mumin N, Ramli Hamid MT, Wong JHD, Chiew SF, Rahmat K, Ng KH
    PLoS One, 2024;19(8):e0309131.
    PMID: 39208284 DOI: 10.1371/journal.pone.0309131
    OBJECTIVES: Accurate subtyping of breast cancer is crucial for its diagnosis, management, and prognostication. This study aimed to determine the association of magnetic resonance imaging (MRI) breast features with the molecular subtype and aggressiveness of breast cancer in a multi-ethnic population.

    METHODS: Treatment-naive patients with invasive breast carcinoma were included in this retrospective study. Breast MRI features were recorded based on the American College of Radiology-Breast Imaging Reporting and Data System (ACR-BIRADS) criteria, with tumour size, and apparent diffusion coefficient value (ADC). The statistical association was tested with Pearson Chi-Square Test of Independence for categorical data or the Kruskal-Wallis/ Mann Whitney U test for numerical data between the MRI features and molecular subtype, receptor status, tumour grade, lymphovascular infiltration (LVI) and axillary lymph node (ALN). Multinomial logistic regression was used to test the predictive likelihood of the significant features. The breast cancer subtypes were determined via immunohistochemistry (IHC) and dual-color dual-hapten in-situ hybridization (D-DISH). The expression statuses of ER, PR, and HER-2, LVI, and ALN were obtained from the histopathology report. The ER / PR / HER-2 was evaluated according to the American Society of Clinical Oncology / College of American Pathologists.

    RESULTS: The study included 194 patients; 41.8% (n = 81) Chinese, 40.7% (n = 79) Malay, and 17.5% (n = 34) Indian, involving 71.6%(n = 139) luminal-like, 12.9%(n = 25) HER-2 enriched, and 15.5%(n = 30) Triple-negative breast cancer (TNBC). TNBC was associated with rim enhancement (p = 0.002) and peritumoral oedema (p = 0.004). HER-2 enriched tumour was associated with larger tumour size (p = 0.041). Luminal-like cancer was associated with irregular shape (p = 0.005) with circumscribed margin (p = 0.003). Other associations were ER-negative tumour with circumscribed margin (p = 0.002) and PR-negative with round shape (p = 0.001). Tumour sizes were larger in ER-negative (p = 0.044) and PR-negative (p = 0.022). Rim enhancement was significantly associated with higher grade (p = 0.001), and moderate peritumoral oedema with positive axillary lymph node (p = 0.002).

    CONCLUSION: Certain MRI features can be applied to differentiate breast cancer molecular subtypes, receptor status and aggressiveness, even in a multi-ethnic population.

  11. Mohd Haniff NS, Ng KH, Kamal I, Mohd Zain N, Abdul Karim MK
    Heliyon, 2024 Aug 30;10(16):e36313.
    PMID: 39253167 DOI: 10.1016/j.heliyon.2024.e36313
    The aim of this systematic review and meta-analysis is to evaluate the performance of classification metrics of machine learning-driven radiomics in diagnosing hepatocellular carcinoma (HCC). Following the PRISMA guidelines, a comprehensive search was conducted across three major scientific databases-PubMed, ScienceDirect, and Scopus-from 2018 to 2022. The search yielded a total of 436 articles pertinent to the application of machine learning and deep learning for HCC prediction. These studies collectively reflect the burgeoning interest and rapid advancements in employing artificial intelligence (AI)-driven radiomics for enhanced HCC diagnostic capabilities. After the screening process, 34 of these articles were chosen for the study. The area under curve (AUC), accuracy, specificity, and sensitivity of the proposed and basic models were assessed in each of the studies. Jamovi (version 1.1.9.0) was utilised to carry out a meta-analysis of 12 cohort studies to evaluate the classification accuracy rate. The risk of bias was estimated, and Logistic Regression was found to be the most suitable classifier for binary problems, with least absolute shrinkage and selection operator (LASSO) as the feature selector. The pooled proportion for HCC prediction classification was high for all performance metrics, with an AUC value of 0.86 (95 % CI: 0.83-0.88), accuracy of 0.83 (95 % CI: 0.78-0.88), sensitivity of 0.80 (95 % CI: 0.75-0.84) and specificity of 0.84 (95 % CI: 0.80-0.88). The performance of feature selectors, classifiers, and input features in detecting HCC and related factors was evaluated and it was observed that radiomics features extracted from medical images were adequate for AI to accurately distinguish the condition. HCC based radiomics has favourable predictive performance especially with addition of clinical features that may serve as tool that support clinical decision-making.
  12. Yeong CH, Abdullah BJ, Ng KH, Chung LY, Goh KL, Sarji SA, et al.
    Appl Radiat Isot, 2012 Mar;70(3):450-5.
    PMID: 22178699 DOI: 10.1016/j.apradiso.2011.11.056
    We produced an enteric-coated gelatine capsule containing neutron-activated (153)Sm-labelled resin beads for use in gastrointestinal motility studies. In vitro test in simulated gastrointestinal environment and in vivo study on volunteers were performed. Scintigraphic images were acquired from ten volunteers over 24h while blood and urine samples were collected to monitor the presence of (153)Sm. All the capsules remained intact in stomach. This proved to be a safe and practical oral capsule formulation for whole gut transit scintigraphy.
  13. Yeong CH, Abdullah BJ, Ng KH, Chung LY, Goh KL, Sarji SA, et al.
    Nucl Med Commun, 2011 Dec;32(12):1256-60.
    PMID: 21934547 DOI: 10.1097/MNM.0b013e32834b3ac8
    Nuclear medicine techniques are well established for the investigation of gastrointestinal (GI) motility and transit. Ion-exchange resins radiolabelled with ⁹⁹mTc and ¹¹¹In are widely used as nonabsorbable radiopharmaceutical markers, with ¹¹¹In being preferred for whole-gut transit studies. This radionuclide, however, is not produced in many countries and may be expensive when obtained through international shipment. This study describes the use of neutron-activated ¹⁵³Sm-resin as an alternative tracer for use in GI scintigraphic investigation. A measure of 50 mg of stable samarium-152 chloride (¹⁵²SmCl₃) was incorporated into 100 mg of cation-exchange resin and irradiated in a neutron flux of 1 × 10¹³ cm⁻² s⁻¹ for 100 s to achieve an activity of 5 MBq after 66 h. Aliquots of ¹¹¹In-radiolabelled resin (5 MBq) were prepared for comparison of labelling and stability. Radiolabelling efficiencies were obtained by washing resin with distilled water, and the activity lost was measured. The radiolabelled resins were immersed in simulated gastric and intestinal fluid environments, and the retention of ¹⁵³Sm³⁺ and ¹¹¹In³⁺ was measured over a 24 h period. At 66 h after production, 91.15 ± 12.42% of ¹⁵³Sm was bound to the resin after washing in distilled water, whereas radiolabelling with ¹¹¹In achieved 99.96 ± 0.02% efficiency. Both radiolabelled resins demonstrated almost 100% stability in simulated intestinal fluid and >90% stability in artificial gastric juice over 24 h. The performance of neutron-activated ¹⁵³Sm-resin is similar to that of ¹¹¹In-resin and can be used as an alternative tracer for GI transit studies when In is not available.
  14. Hashikin NA, Yeong CH, Abdullah BJ, Ng KH, Chung LY, Dahalan R, et al.
    PLoS One, 2015;10(9):e0138106.
    PMID: 26382059 DOI: 10.1371/journal.pone.0138106
    Samarium-153 (153Sm) styrene divinylbenzene microparticles were developed as a surrogate for Yttrium-90 (90Y) microspheres in liver radioembolization therapy. Unlike the pure beta emitter 90Y, 153Sm possess both therapeutic beta and diagnostic gamma radiations, making it possible for post-procedure imaging following therapy.
  15. Yusof FH, Ung NM, Wong JH, Jong WL, Ath V, Phua VC, et al.
    PLoS One, 2015;10(6):e0128544.
    PMID: 26052690 DOI: 10.1371/journal.pone.0128544
    This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface doses were measured on a solid water phantom using the OSLD and compared against the Markus ionization chamber and Gafchromic EBT3 film measurements. The effect of incident beam angles on surface dose was also studied. The OSLD was subsequently used to measure surface dose during tangential breast radiotherapy treatments in a phantom study and in the clinical measurement of 10 patients. Surface dose to the treated breast or chest wall, and on the contralateral breast were measured. The WED of the OSLD was found to be at 0.4 mm. For surface dose measurement on a solid water phantom, the Markus ionization chamber measured 15.95% for 6 MV photon beam and 12.64% for 10 MV photon beam followed by EBT3 film (23.79% and 17.14%) and OSLD (37.77% and 25.38%). Surface dose increased with the increase of the incident beam angle. For phantom and patient breast surface dose measurement, the response of the OSLD was higher than EBT3 film. The in-vivo measurements were also compared with the treatment planning system predicted dose. The OSLD measured higher dose values compared to dose at the surface (Hp(0.0)) by a factor of 2.37 for 6 MV and 2.01 for 10 MV photon beams, respectively. The measurement of absorbed dose at the skin depth of 0.4 mm by the OSLD can still be a useful tool to assess radiation effects on the skin dermis layer. This knowledge can be used to prevent and manage potential acute skin reaction and late skin toxicity from radiotherapy treatments.
  16. Tan SK, Ng KH, Yeong CH, Raja Aman RRA, Mohamed Sani F, Abdul Aziz YF, et al.
    Quant Imaging Med Surg, 2019 Apr;9(4):552-564.
    PMID: 31143647 DOI: 10.21037/qims.2019.03.13
    Background: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol.

    Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.

    Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).

    Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

  17. Teoh LY, Lai LL, Hanim Aa A, Teh MS, Jamaris S, Yahya A, et al.
    Breast J, 2020 11;26(11):2208-2212.
    PMID: 32996224 DOI: 10.1111/tbj.14060
    Oncoplastic breast surgery (OBS) improves margin clearance and produces good esthetic outcome in breast cancer treatment. This study evaluates the complications and outcome of OBS in a multiracial patient cohort. Data of 421 patients between 2011 and 2018 were analyzed. The majority were Malays (41.8%), followed by Chinese (39.7%) and Indians (16.8%). Low local complications were noted, with no significant differences in disease-free survival (P = .927) and overall survival (P = .719) between low and high OBS levels. Shared decision-making in offering OBS for Asian women has potential to become a practical option in breast cancer treatment.
  18. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Mohd Sharif NH, et al.
    Ultrasound Med Biol, 2020 01;46(1):34-45.
    PMID: 31594681 DOI: 10.1016/j.ultrasmedbio.2019.08.011
    Tissue elasticity is related to the pathologic state of kidneys and can be measured using shear wave elastography (SWE). However, SWE quantification has not been rigorously validated. The aim of this study was to evaluate the accuracy of SWE-measured stiffness and the effect of tissue anisotropy on SWE measurements. Point SWE (pSWE), 2-D SWE and dynamic mechanical analysis (DMA) were used to measure stiffness and evaluate the effect of tissue anisotropy on the measurements. SWE and DMA were performed on phantoms of different gelatin concentrations. In the tissue anisotropy study, SWE and DMA were performed on the outer cortex of sheep kidneys. In the in vivo study, 15 patients with different levels of interstitial fibrosis were recruited for pSWE measurements. Another 10 healthy volunteers were recruited for tissue anisotropy studies. SWE imaging revealed a non-linear increase with gelatin concentration. There was a significant correlation between pSWE and 2-D SWE, leading to the establishment of a linear regression equation between the two SWE ultrasound measurements. In the anisotropy study, the median difference in stiffness between shear waves oriented at 0° and 90° towards the pyramid axis was significant. In the in vivo study, there was a strong positive linear correlation between pSWE and the percentage of interstitial fibrosis. There was a significant difference in the Young's modulus (YM) between severities of fibrosis. The mean YM values were lower in control patients than in patients with mild, moderate and severe fibrosis. YM values were also significantly higher when shear waves were oriented at 0° toward the pyramid axis. Tissue stiffness and anisotropy affects SWE measurements. These factors should be recognized before applying SWE for the interpretation of measured values.
  19. Jong WL, Wong JH, Ung NM, Ng KH, Ho GF, Cutajar DL, et al.
    J Appl Clin Med Phys, 2014 Sep 08;15(5):4869.
    PMID: 25207573 DOI: 10.1120/jacmp.v15i5.4869
    In vivo dosimetry is important during radiotherapy to ensure the accuracy of the dose delivered to the treatment volume. A dosimeter should be characterized based on its application before it is used for in vivo dosimetry. In this study, we characterize a new MOSFET-based detector, the MOSkin detector, on surface for in vivo skin dosimetry. The advantages of the MOSkin detector are its water equivalent depth of measurement of 0.07 mm, small physical size with submicron dosimetric volume, and the ability to provide real-time readout. A MOSkin detector was calibrated and the reproducibility, linearity, and response over a large dose range to different threshold voltages were determined. Surface dose on solid water phantom was measured using MOSkin detector and compared with Markus ionization chamber and GAFCHROMIC EBT2 film measurements. Dependence in the response of the MOSkin detector on the surface of solid water phantom was also tested for different (i) source to surface distances (SSDs); (ii) field sizes; (iii) surface dose; (iv) radiation incident angles; and (v) wedges. The MOSkin detector showed excellent reproducibility and linearity for dose range of 50 cGy to 300 cGy. The MOSkin detector showed reliable response to different SSDs, field sizes, surface, radiation incident angles, and wedges. The MOSkin detector is suitable for in vivo skin dosimetry.
  20. Ismail UN, Azlan CA, Khairullah S, Azman RR, Omar NF, Md Shah MN, et al.
    J Magn Reson Imaging, 2021 01;53(1):190-198.
    PMID: 33237616 DOI: 10.1002/jmri.27294
    BACKGROUND: β-thalassemia is a genetic disease that causes abnormal production of red blood cells (ineffective erythropoiesis, IE). IE is a condition known to change bone marrow composition.

    PURPOSE: To evaluate the effect of IE on the marrow fat content and fat unsaturation levels in the proximal femur using 1 H-MRS.

    STUDY TYPE: Prospective.

    SUBJECTS: Twenty-three subjects were included in this study, seven control and 16 β-thalassemia subjects.

    FIELD STRENGTH/SEQUENCE: 3.0T; stimulated echo acquisition Mode (STEAM); magnetic resonance spectroscopy (MRS) sequence.

    ASSESSMENT: Multiecho MRS scans were performed in four regions of the proximal left femur of each subject, that is, diaphysis, femoral neck, femoral head, and greater trochanter. The examined regions were grouped into red (diaphysis and femoral neck) and yellow marrow regions (femoral head and greater trochanter).

    STATISTICAL TESTS: The Jonckheere-Terpstra test was used to evaluate the impact of increasing disease severity on bone marrow fat fraction (BMFF), marrow conversion index, and fat unsaturation index (UI). Pairwise comparison analysis was performed when a significant trend (P 