METHODS AND RESULTS: We evaluated 54 subjects (43 patients with a clinical indication for CMR and 11 healthy volunteers) in a study comparing TTE- and CMR-derived LA reservoir strain (ƐR), conduit strain (ƐCD), and contractile strain (ƐCT). The LA strain components were evaluated using four dedicated types of post-processing software. We evaluated the correlation and systematic bias between modalities and within each modality. Intervendor and intermodality correlation was: ƐR [intraclass correlation coefficient (ICC 0.64-0.90)], ƐCD (ICC 0.62-0.89), and ƐCT (ICC 0.58-0.77). There was evidence of systematic bias between vendors and modalities with mean differences ranging from (3.1-12.2%) for ƐR, ƐCD (1.6-8.6%), and ƐCT (0.3-3.6%). Reproducibility analysis revealed intraobserver coefficient of variance (COV) of 6.5-14.6% and interobserver COV of 9.9-18.7%.
CONCLUSION: Vendor derived ƐR, ƐCD, and ƐCT demonstrates modest to excellent intervendor and intermodality correlation depending on strain component examined. There are systematic differences in measurements depending on modality and vendor. These differences may be addressed by future studies, which, examine calibration of LA geometry/higher frame rate imaging, semi-quantitative approaches, and improvements in reproducibility.
METHODS: The morphological features of the disc that is characteristic of glaucoma are clearly seen in the fundus images. However, manual inspection of the acquired fundus images may be prone to inter-observer variation. Therefore, a computer-aided detection (CAD) system is proposed to make an accurate, reliable and fast diagnosis of glaucoma based on the optic nerve features of fundus imaging. In this paper, we reviewed existing techniques to automatically diagnose glaucoma.
RESULTS: The use of CAD is very effective in the diagnosis of glaucoma and can assist the clinicians to alleviate their workload significantly. We have also discussed the advantages of employing state-of-art techniques, including deep learning (DL), when developing the automated system. The DL methods are effective in glaucoma diagnosis.
CONCLUSIONS: Novel DL algorithms with big data availability are required to develop a reliable CAD system. Such techniques can be employed to diagnose other eye diseases accurately.
Material and Methods: In this study, we have introduced a new technique to reduce the motion artifacts, based on data binning and low rank plus sparse (L+S) reconstruction method for DCE MRI. For Data binning, radial k-space data is acquired continuously using the golden-angle radial sampling pattern and grouped into various motion states or bins. The respiratory signal for binning is extracted directly from radially acquired k-space data. A compressed sensing- (CS-) based L+S matrix decomposition model is then used to reconstruct motion sorted DCE MR images. Undersampled free breathing 3D liver and abdominal DCE MR data sets are used to validate the proposed technique.
Results: The performance of the technique is compared with conventional L+S decomposition qualitatively along with the image sharpness and structural similarity index. Recovered images are visually sharper and have better similarity with reference images.
Conclusion: L+S decomposition provides improved MR images with data binning as preprocessing step in free breathing scenario. Data binning resolves the respiratory motion by dividing different respiratory positions in multiple bins. It also differentiates the respiratory motion and contrast agent (CA) variations. MR images recovered for each bin are better as compared to the method without data binning.