Displaying publications 61 - 80 of 117 in total

Abstract:
Sort:
  1. Safari MJ, Wong JHD, Jong WL, Thorpe N, Cutajar D, Rosenfeld A, et al.
    Phys Med, 2017 Mar;35:66-72.
    PMID: 28256398 DOI: 10.1016/j.ejmp.2017.02.002
    PURPOSE: The purpose of this study was to investigate the effects of routine exposure parameters on patient's dose during neuro-interventional radiology procedures.

    METHODS: We scrutinized the routine radiological exposure parameters during 58 clinical neuro-interventional procedures such as, exposure direction, magnification, frame rate, and distance between image receptor to patient's body and evaluate their effects on patient's dose using an anthropomorphic phantom. Radiation dose received by the occipital region, ears and eyes of the phantom were measured using MOSkin detectors.

    RESULTS: DSA imaging technique is a major contributor to patient's dose (80.9%) even though they are used sparingly (5.3% of total frame number). The occipital region of the brain received high dose largely from the frontal tube constantly placed under couch (73.7% of the total KAP). When rotating the frontal tube away from under the couch, the radiation dose to the occipital reduced by 40%. The use of magnification modes could increase radiation dose by 94%. Changing the image receptor to the phantom surface distance from 10 to 40cm doubled the radiation dose received by the patient's skin at the occipital region.

    CONCLUSION: Our findings provided important insights into the contribution of selected fluoroscopic exposure parameters and their impact on patient's dose during neuro-interventional radiology procedures. This study showed that the DSA imaging technique contributed to the highest patient's dose and judicial use of exposure parameters might assist interventional radiologists in effective skin and eye lens dose reduction for patients undergoing neuro-interventional procedures.

    Matched MeSH terms: Phantoms, Imaging
  2. Adibah Yusof NA, Abdul Karim MK, Asikin NM, Paiman S, Awang Kechik MM, Abdul Rahman MA, et al.
    Curr Med Imaging, 2023;19(10):1105-1113.
    PMID: 35975862 DOI: 10.2174/1573405618666220816160544
    BACKGROUND: For almost three decades, computed tomography (CT) has been extensively used in medical diagnosis, which led researchers to conduct linking of CT dose exposure with image quality.

    METHODS: In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. We utilize PubMed, ScienceDirect, Google Scholar and Scopus databases to search related published articles from the year 2011 until 2020. The notable keywords comprise "computed tomography", "CT phantom", and "low contrast detectability". Of 52 articles, 20 articles are within the inclusion criteria in this systematic review.

    RESULTS: The dichotomous outcomes were chosen to represent the results in terms of risk ratio as per meta-analysis study. Notably, the noise in iterative reconstruction (IR) reduced by 24%, 33% and 36% with the use of smooth, medium and sharp filters, respectively. Furthermore, adaptive iterative dose reduction (AIDR 3D) improved image quality and the visibility of smaller less dense objects compared to filtered back-projection. Most of the researchers used 120 kVp tube voltage to scan phantom for quality assurance study.

    CONCLUSION: Hence, optimizing primary factors such as tube potential reduces the dose exposure significantly, and the optimized IR technique could substantially reduce the radiation dose while maintaining the image quality.

    Matched MeSH terms: Phantoms, Imaging
  3. Moey, Soo-Foon, Nur Farah Hani Muhd Jaafar, Nursyahirah Saidin
    MyJurnal
    Introduction: Various medium and high tube potentials were utilized to conduct chest x-rays. There
    are advantages and disadvantages with regards to image quality and radiation dose when using
    medium and high kilovoltage (kVp) technique. However, radiographers have misconstrued
    understanding pertaining to the choice of tube potential as well as grid usage when performing chest radiography. Methods: The experimental study was conducted using the PBU-50 phantom by exposing it with medium kVp utilizing grid and non-grid as well as high kVp with grid. All images obtained were evaluated using the modified evaluation criteria for PA chest established by the Commission of European Communities, 1996 whilst the dose area product (DAP) was determined using the Dose Area Product (DAP) meter. The value obtained from the DAP meter was converted to entrance surface dose (ESD) usingCALDOSE_X5.0 software and mathematical formula. Results: The Wilcoxon Signed-Rank Test indicated a significant difference in ESD when using medium and high kVp; Z= -2.666, p
    Matched MeSH terms: Phantoms, Imaging
  4. Rabba JA, Suhaimi FM, Mat Jafri MZ, Jaafar HA, Osman ND
    Radiography (Lond), 2023 May;29(3):533-538.
    PMID: 36913788 DOI: 10.1016/j.radi.2023.02.028
    INTRODUCTION: The daily image quality assessment involves large datasets that consume a lot of time and effort. This study aims to evaluate a proposed automated calculator for image distortion analysis in 2-dimensional (2D) panoramic imaging mode for a dental cone beam computed tomography (CBCT) system in comparison with present manual calculations.

    METHODS: A ball phantom was scanned using panoramic mode of the Planmeca ProMax 3D Mid CBCT unit (Planmeca, Helsinki, Finland) with standard exposure settings used in clinical practice (60 kV, 2 mA, and maximum FOV). An automated calculator algorithm was developed in MATLAB platform. Two parameters associated with panoramic image distortion such as balls diameter and distance between middle and tenth balls were measured. These automated measurements were compared with manual measurement using the Planmeca Romexis and ImageJ software.

    RESULTS: The findings showed smaller deviation in distance difference measurements by proposed automated calculator (ranged 3.83 mm) as compared to manual measurements (ranged 5.00 for Romexis and 5.12 mm for ImageJ software). There was a significant difference (p 

    Matched MeSH terms: Phantoms, Imaging
  5. Hall SK, Ooi EH, Payne SJ
    Crit Rev Biomed Eng, 2014;42(5):383-417.
    PMID: 25745803
    Minimally invasive tumor ablations (MITAs) are an increasingly important tool in the treatment of solid tumors across multiple organs. The problems experienced in modeling different types of MITAs are very similar, but the development of mathematical models is mostly performed in isolation according to modality. Fundamental research into the modeling of specific types of MITAs is indeed required, but to choose the optimal treatment for an individual the primary clinical requirement is to have reliable predictions for a range of MITAs. In this review of the mathematical modeling of MITAs 4 modalities are considered: radiofrequency ablation, microwave ablation, cryoablation, and irreversible electroporation. The similarities in the mathematical modeling of these treatments are highlighted, and the analysis of the models within a general framework is discussed. This will aid in developing a deeper understanding of the sensitivity of MITA models to physiological parameters and the impact of uncertainty on predictions of the ablation zone. Through robust validation and analysis of the models it will be possible to choose the best model for a given application. This is important because many different models exist with no objective comparison of their performance. The collection of relevant in vivo experimental data is also critical to parameterize such models accurately. This approach will be necessary to translate the field into clinical practice.
    Matched MeSH terms: Phantoms, Imaging
  6. Hashikin NAA, Yeong CH, Guatelli S, Abdullah BJJ, Ng KH, Malaroda A, et al.
    Phys Med Biol, 2017 Aug 22;62(18):7342-7356.
    PMID: 28686171 DOI: 10.1088/1361-6560/aa7e5b
    We aimed to investigate the validity of the partition model (PM) in estimating the absorbed doses to liver tumour ([Formula: see text]), normal liver tissue ([Formula: see text]) and lungs ([Formula: see text]), when cross-fire irradiations between these compartments are being considered. MIRD-5 phantom incorporated with various treatment parameters, i.e. tumour involvement (TI), tumour-to-normal liver uptake ratio (T/N) and lung shunting (LS), were simulated using the Geant4 Monte Carlo (MC) toolkit. 108track histories were generated for each combination of the three parameters to obtain the absorbed dose per activity uptake in each compartment ([Formula: see text], [Formula: see text], and [Formula: see text]). The administered activities, A were estimated using PM, so as to achieve either limiting doses to normal liver, [Formula: see text] or lungs, [Formula: see text] (70 or 30 Gy, respectively). Using these administered activities, the activity uptake in each compartment ([Formula: see text], [Formula: see text], and [Formula: see text]) was estimated and multiplied with the absorbed dose per activity uptake attained using the MC simulations, to obtain the actual dose received by each compartment. PM overestimated [Formula: see text] by 11.7% in all cases, due to the escaped particles from the lungs. [Formula: see text] and [Formula: see text] by MC were largely affected by T/N, which were not considered by PM due to cross-fire exclusion at the tumour-normal liver boundary. These have resulted in the overestimation of [Formula: see text] by up to 8% and underestimation of [Formula: see text] by as high as  -78%, by PM. When [Formula: see text] was estimated via PM, the MC simulations showed significantly higher [Formula: see text] for cases with higher T/N, and LS  ⩽  10%. All [Formula: see text] and [Formula: see text] by MC were overestimated by PM, thus [Formula: see text] were never exceeded. PM leads to inaccurate dose estimations due to the exclusion of cross-fire irradiation, i.e. between the tumour and normal liver tissue. Caution should be taken for cases with higher TI and T/N, and lower LS, as they contribute to major underestimation of [Formula: see text]. For [Formula: see text], a different correction factor for dose calculation may be used for improved accuracy.
    Matched MeSH terms: Phantoms, Imaging*
  7. Ng AH, Alqahtani MS, Jambi LK, Bugby SL, Lees JE, Perkins AC
    Br J Radiol, 2019 Jun;92(1098):20190020.
    PMID: 30864832 DOI: 10.1259/bjr.20190020
    OBJECTIVE: To examine the imaging capability of a novel small field of view hybrid gamma camera (HGC) using 125I seeds prior to surgical use.

    METHODS: The imaging performance of the camera system was assessed quantitatively and qualitatively at different source depths, source to collimator distances (SCD), activity levels, acquisition times and source separations, utilising bespoke phantoms.

    RESULTS: The system sensitivity and spatial resolution of the HGC for 125I were 0.41 cps/MBq (at SCD 48 mm) and 1.53 ± 0.23 mm (at SCD 10 mm) respectively. The camera was able to detect the 125I seed at a SCD of 63 mm (with no scattering material in place) in images recorded within a 1-min acquisition time. The detection of the seeds beneath scattering material (simulating deep-seated tumours) was limited to depths of less than 20 mm beneath the skin surface with a SCD of 63 mm and seed activity of 2.43 MBq. Subjective assessments of the hybrid images acquired showed the capability of the HGC for localising the 125I seeds.

    CONCLUSION: This preliminary ex vivo study demonstrates that the HGC is capable of detecting 125I seeds and could be a useful tool in radioactive seed localisation with the added benefit of providing hybrid optical γ images for guiding breast conserving surgery.

    ADVANCES IN KNOWLEDGE: The SFOV HGC could provide high resolution fused optical-gamma images of 125I radioactive seeds indicating the potential use in intraoperative surgical procedure such as RSL.

    Matched MeSH terms: Phantoms, Imaging
  8. Alsadig AA, Abbas S, Kandaiya S, Ashikin NARNN, Qaeed MA
    Appl Radiat Isot, 2017 Nov;129:130-134.
    PMID: 28843699 DOI: 10.1016/j.apradiso.2017.08.021
    Phantoms are devices that simulate human tissues including soft tissues, lungs, and bones in medical and health physics. The purpose of this work was to investigate the differential dose absorption in several commercially available low-cost materials as substitutes to human tissues using Gafchromic XR-QA2 film. The measurement of absorbed dose by different materials of various densities was made using the film to establish the relationship between the absorbed dose and the material density. Materials investigated included soft board materials, Perspex, chicken bone, Jeltrate, chalk, cow bone, marble, and aluminum, which have varying densities from 0.26 to 2.67gcm-3. The absorbed dose increased as the density and atomic number of the material increased. The absorbed dose to the density can be well represented by a polynomial function for the materials used.
    Matched MeSH terms: Phantoms, Imaging*
  9. Hairenanorashikin Sharip, Rafidah Supar
    MyJurnal
    This experimental study investigated the significant different in image quality and dose between different
    automatic exposure of exposure parameter (AOP) mode in full field digital mammography (FFDM) system.
    CIRS012A and PMMA breast phantom (4cm, 5cm and 6 cm thickness) were used as subject using
    Senographe Essential FFDM system. TLD chip was used as dose measurement tool. Exposures were taken
    in cranio-caudal projection. 2 radiographers with more than 10 years of working experience in performing
    mammography scored the image independently. Kappa finds a good agreement between raters (kappa
    value=0.9, p0.05). DOSE mode is the preferred selection in optimizing between dose and image quality.
    Matched MeSH terms: Phantoms, Imaging
  10. Ramli N, Khairy AM, Seow P, Tan LK, Wong JH, Ganesan D, et al.
    Eur Radiol, 2016 Jul;26(7):2019-29.
    PMID: 26560718 DOI: 10.1007/s00330-015-4045-0
    OBJECTIVES: We evaluated the feasibility of using chemical shift gradient-echo (GE) in- and opposed-phase (IOP) imaging to grade glioma.

    METHODS: A phantom study was performed to investigate the correlation of (1)H MRS-visible lipids with the signal loss ratio (SLR) obtained using IOP imaging. A cross-sectional study approved by the institutional review board was carried out in 22 patients with different glioma grades. The patients underwent scanning using IOP imaging and single-voxel spectroscopy (SVS) using 3T MRI. The brain spectra acquisitions from solid and cystic components were obtained and correlated with the SLR for different grades.

    RESULTS: The phantom study showed a positive linear correlation between lipid quantification at 0.9 parts per million (ppm) and 1.3 ppm with SLR (r = 0.79-0.99, p 

    Matched MeSH terms: Phantoms, Imaging
  11. Dabbagh A, Abdullah BJ, Abu Kasim NH, Ramasindarum C
    Int J Hyperthermia, 2014 Feb;30(1):66-74.
    PMID: 24286257 DOI: 10.3109/02656736.2013.854930
    The emergence of thermal modalities has promoted the use of heat-sensitive phantoms for calibration, measurement, and verification purposes. However, development of durable phantoms with high precision ability to represent the temperature distribution remains a challenge. This study aims to introduce a reusable phantom that provides an accurate assessment of the heated region in various thermal modalities.
    Matched MeSH terms: Phantoms, Imaging*
  12. Sanusi MSM, Hassan WMSW, Hashim S, Ramli AT
    Appl Radiat Isot, 2021 Aug;174:109791.
    PMID: 34062400 DOI: 10.1016/j.apradiso.2021.109791
    Terrestrial radioactivity monitoring of 238U and 232Th series, and 40K in soil is an essential practice for radioactivity and radiation measurement of a place. In conventional practice, only basic data can be in-situ measured using a survey instrument, for example radioactivity concentration in soil and ambient dose equivalent rate. For other physical quantities, for example organ absorbed dose and organ equivalent dose, the measurement is impossible to be performed and can only be computed using Monte Carlo radiation transport simulations. In the past, most of the works only focused on calculating air-kerma-to-effective dose conversion factors. However, the information on organ dose conversion factors is scarcely documented and reported. This study was conducted to calculate organ absorbed and tissue-weighted equivalent dose conversion factors as a result of exposure from terrestrial gamma radiation. Series of organ dose conversion factors is produced based on computations from Monte Carlo MCNP5 simulations using modelled gamma irradiation geometry and established adult MIRD phantom. The study found out that most of the radiation exposed organs absorb energy at comparable rates, except for dense and superficial tissues i.e., skeleton and skin, which indicated slightly higher values. The good agreement between this work and previous studies demonstrated that our gamma irradiation geometry and modelling of gamma radiation sources are adequate. Therefore, the proposed organ dose conversion factors from this study are reasonably acceptable for dose estimation in environmental radioactivity monitoring practices.
    Matched MeSH terms: Phantoms, Imaging
  13. Hani AF, Kumar D, Malik AS, Razak R
    Magn Reson Imaging, 2013 Sep;31(7):1059-67.
    PMID: 23731535 DOI: 10.1016/j.mri.2013.01.007
    Osteoarthritis is a common joint disorder that is most prevalent in the knee joint. Knee osteoarthritis (OA) can be characterized by the gradual loss of articular cartilage (AC). Formation of lesion, fissures and cracks on the cartilage surface has been associated with degenerative AC and can be measured by morphological assessment. In addition, loss of proteoglycan from extracellular matrix of the AC can be measured at early stage of cartilage degradation by physiological assessment. In this case, a biochemical phenomenon of cartilage is used to assess the changes at early degeneration of AC. In this paper, a method to measure local sodium concentration in AC due to proteoglycan has been investigated. A clinical 1.5-T magnetic resonance imaging (MRI) with multinuclear spectroscopic facility is used to acquire sodium images and quantify local sodium content of AC. An optimised 3D gradient-echo sequence with low echo time has been used for MR scan. The estimated sodium concentration in AC region from four different data sets is found to be ~225±19mmol/l, which matches the values that has been reported for the normal AC. This study shows that sodium images acquired at clinical 1.5-T MRI system can generate an adequate quantitative data that enable the estimation of sodium concentration in AC. We conclude that this method is potentially suitable for non-invasive physiological (sodium content) measurement of articular cartilage.
    Matched MeSH terms: Phantoms, Imaging
  14. Safari MJ, Wong JH, Ng KH, Jong WL, Cutajar DL, Rosenfeld AB
    Med Phys, 2015 May;42(5):2550-8.
    PMID: 25979047 DOI: 10.1118/1.4918576
    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures.
    Matched MeSH terms: Phantoms, Imaging
  15. Salim MI, Supriyanto E, Haueisen J, Ariffin I, Ahmad AH, Rosidi B
    Med Biol Eng Comput, 2013 Apr;51(4):459-66.
    PMID: 23238828 DOI: 10.1007/s11517-012-1014-5
    This paper proposes a novel hybrid magnetoacoustic measurement (HMM) system aiming at breast cancer detection. HMM combines ultrasound and magnetism for the simultaneous assessment of bioelectric and acoustic profiles of breast tissue. HMM is demonstrated on breast tissue samples, which are exposed to 9.8 MHz ultrasound wave with the presence of a 0.25 Tesla static magnetic field. The interaction between the ultrasound wave and the magnetic field in the breast tissue results in Lorentz Force that produces a magnetoacoustic voltage output, proportional to breast tissue conductivity. Simultaneously, the ultrasound wave is sensed back by the ultrasound receiver for tissue acoustic evaluation. Experiments are performed on gel phantoms and real breast tissue samples harvested from laboratory mice. Ultrasound wave characterization results show that normal breast tissue experiences higher attenuation compared with cancerous tissue. The mean magnetoacoustic voltage results for normal tissue are lower than that for the cancerous tissue group. In conclusion, the combination of acoustic and bioelectric measurements is a promising approach for breast cancer diagnosis.
    Matched MeSH terms: Phantoms, Imaging
  16. Rosli Darmawan
    MyJurnal
    The study on the possibility of using DMU Kinematics module in CAE tools for dose exposure work planning was carried out. A case scenario was created using 3D CAD software and transferred to DMU Kinematics module in a CAE software. The work plan created using DMU Kinematics module was animated to simulate a real time scenario. Data on the phantom position against the radioactive source was collected by activating positioning sensors in the module. The data collected was used to calculate the estimated dose rate exposure for the phantom. The results can be used to plan the safest and optimum procedures in carrying out the radiation related task.
    Matched MeSH terms: Phantoms, Imaging
  17. Aziz MZ, Yusoff AL, Osman ND, Abdullah R, Rabaie NA, Salikin MS
    J Med Phys, 2015 Jul-Sep;40(3):150-5.
    PMID: 26500401 DOI: 10.4103/0971-6203.165080
    It has become a great challenge in the modern radiation treatment to ensure the accuracy of treatment delivery in electron beam therapy. Tissue inhomogeneity has become one of the factors for accurate dose calculation, and this requires complex algorithm calculation like Monte Carlo (MC). On the other hand, computed tomography (CT) images used in treatment planning system need to be trustful as they are the input in radiotherapy treatment. However, with the presence of metal amalgam in treatment volume, the CT images input showed prominent streak artefact, thus, contributed sources of error. Hence, metal amalgam phantom often creates streak artifacts, which cause an error in the dose calculation. Thus, a streak artifact reduction technique was applied to correct the images, and as a result, better images were observed in terms of structure delineation and density assigning. Furthermore, the amalgam density data were corrected to provide amalgam voxel with accurate density value. As for the errors of dose uncertainties due to metal amalgam, they were reduced from 46% to as low as 2% at d80 (depth of the 80% dose beyond Zmax) using the presented strategies. Considering the number of vital and radiosensitive organs in the head and the neck regions, this correction strategy is suggested in reducing calculation uncertainties through MC calculation.
    Matched MeSH terms: Phantoms, Imaging
  18. Hossain A, Islam MT, Islam MT, Chowdhury MEH, Rmili H, Samsuzzaman M
    Materials (Basel), 2020 Nov 02;13(21).
    PMID: 33147702 DOI: 10.3390/ma13214918
    In this paper, a compact planar ultrawideband (UWB) antenna and an antenna array setup for microwave breast imaging are presented. The proposed antenna is constructed with a slotted semicircular-shaped patch and partial trapezoidal ground. It is compact in dimension: 0.30λ × 0.31λ × 0.011λ, where λ is the wavelength of the lowest operating frequency. For design purposes, several parameters are assumed and optimized to achieve better performance. The prototype is applied in the breast imaging scheme over the UWB frequency range 3.10-10.60 GHz. However, the antenna achieves an operating bandwidth of 8.70 GHz (2.30-11.00 GHz) for the reflection coefficient under-10 dB with decent impedance matching, 5.80 dBi of maximum gain with steady radiation pattern. The antenna provides a fidelity factor (FF) of 82% and 81% for face-to-face and side-by-side setups, respectively, which specifies the directionality and minor variation of the received pulses. The antenna is fabricated and measured to evaluate the antenna characteristics. A 16-antenna array-based configuration is considered to measure the backscattering signal of the breast phantom where one antenna acts as transmitter, and 15 of them receive the scattered signals. The data is taken in both the configuration of the phantom with and without the tumor inside. Later, the Iteratively Corrected Delay and Sum (IC-DAS) image reconstructed algorithm was used to identify the tumor in the breast phantom. Finally, the reconstructed images from the analysis and processing of the backscattering signal by the algorithm are illustrated to verify the imaging performance.
    Matched MeSH terms: Phantoms, Imaging
  19. Islam MT, Mahmud MZ, Islam MT, Kibria S, Samsuzzaman M
    Sci Rep, 2019 10 29;9(1):15491.
    PMID: 31664056 DOI: 10.1038/s41598-019-51620-z
    Globally, breast cancer is a major reason for female mortality. Due to the limitations of current clinical imaging, the researchers are encouraged to explore alternative and complementary tools to available techniques to detect the breast tumor in an earlier stage. This article outlines a new, portable, and low-cost microwave imaging (MWI) system using an iterative enhancing technique for breast imaging. A compact side slotted tapered slot antenna is designed for microwave imaging. The radiating fins of tapered slot antenna are modified by etching nine rectangular side slots. The irregular slots on the radiating fins enhance the electrical length as well as produce strong directive radiation due to the suppression of induced surface currents that radiate vertically at the outer edges of the radiating arms with end-fire direction. It has remarkable effects on efficiency and gain. With the addition of slots, the side-lobe levels are reduced, the gain of the main-lobe is increased and corrects the squint effects simultaneously, thus improving the characteristics of the radiation. For experimental validation, a heterogeneous breast phantom was developed that contains dielectric properties identical to real breast tissues with the inclusion of tumors. An alternative PC controlled and microcontroller-based mechanical MWI system is designed and developed to collect the antenna scattering signal. The radiated backscattered signals from the targeted area of the human body are analyzed to reveal the changes in dielectric properties in tissues. The dielectric constants of tumorous cells are higher than that of normal tissues due to their higher water content. The remarkable deviation of the scattered field is processed by using newly proposed Iteratively Corrected Delay and Sum (IC-DAS) algorithm and the reconstruction of the image of the phantom interior is done. The developed UWB (Ultra-Wideband) antenna based MWI has been able to perform the detection of tumorous cells in breast phantom that can pave the way to saving lives.
    Matched MeSH terms: Phantoms, Imaging
  20. Siti Nur Masturah Abdul Malek, Sayed Inayatullah Shah
    MyJurnal
    In ultrasound imaging there is compromise between the penetration of signal at certain depths into the object and image resolution as the ultrasound probe only can transmit single frequency signals in one transmission. Using curvilinear ultrasound probe with 2 to 5 MHz frequency bandwidth, this study investigated the use of multi-frequency imaging to enhance the quality of phantom images.
    Methods: Siemen Acuson X150 with curvilinear ultrasound transducer was used to scan the organs of interest (kidney, gallbladder and pancreas) of the ultrasound abdominal phantom. Different images at the different selected frequencies (2.5, 3.6 and 5.0 MHz) were created by fixing the position and the orientation of the transducer in each of the scanning process. Different-frequency images were generated and combined to produce composite (multi-frequency) image. Results: In this study, the quality of the composite image was evaluated based on signal-to noise ratio (SNR) and the obtained results were compared with the single frequency images. Besides, the comparison was also made in terms of overall image quality (noise and sharpness of organ outline) through perceived image quality analysis. Based on calculated SNR, the composite image of the kidney, gallbladder and pancreas recorded higher SNR value as compared to the single frequency images. However, through perceived image quality, most of the observers viewed that the quality of the composite image of the kidney, gallbladder and pancreas is poor as compared to the single frequency image. Conclusions: Image quality of ultrasound imaging is improved by combining multiple ultrasound frequency images into a single composite image. This is achieved as high SNR is obtained in the composite image. However, through perceived image quality, the overall image quality of the composite image was poor.
    Matched MeSH terms: Phantoms, Imaging