Displaying publications 61 - 80 of 114 in total

Abstract:
Sort:
  1. Emami Moghaddam SA, Harun R, Mokhtar MN, Zakaria R
    Biomed Res Int, 2018;2018:6563196.
    PMID: 30643814 DOI: 10.1155/2018/6563196
    The interest in utilizing algae for wastewater treatment has been increased due to many advantages. Algae-wastewater treatment system offers a cost-efficient and environmentally friendly alternative to conventional treatment processes such as electrocoagulation and flocculation. In this biosystem, algae can assimilate nutrients in the wastewater for their growth and simultaneously capture the carbon dioxide from the atmosphere during photosynthesis resulting in a decrease in the greenhouse gaseousness. Furthermore, the algal biomass obtained from the treatment process could be further converted to produce high value-added products. However, the recovery of free suspended algae from the treated effluent is one of the most important challenges during the treatment process as the current methods such as centrifugation and filtration are faced with the high cost. Immobilization of algae is a suitable approach to overcome the harvesting issue. However, there are some drawbacks with the common immobilization carriers such as alginate and polyacrylamide related to low stability and toxicity, respectively. Hence, it is necessary to apply a new carrier without the mentioned problems. One of the carriers that can be a suitable candidate for the immobilization is zeolite. To date, various types of zeolite have been used for the immobilization of cells of bacteria and yeast. If there is any possibility to apply them for the immobilization of algae, it needs to be considered in further studies. This article reviews cell immobilization technique, biomass immobilization onto zeolites, and algal immobilization with their applications. Furthermore, the potential application of zeolite as an ideal carrier for algal immobilization has been discussed.
    Matched MeSH terms: Acrylic Resins
  2. Akbari S, Mahmood SM, Tan IM, Ling OL, Ghaedi H
    Polymers (Basel), 2017 Oct 04;9(10).
    PMID: 30965788 DOI: 10.3390/polym9100480
    The viscosity of four new polymers was investigated for the effect of aging at high temperature, with varying degrees of salinity and hardness. The four sulfonated based polyacrylamide co-polymers were FLOCOMB C7035; AN132 VHM; SUPERPUSHER SAV55; and THERMOASSOCIATIF copolymers. All polymer samples were aged at 80 °C for varying times (from zero to at least 90 days) with and without isobutyl alcohol (IBA) as an antioxidant. To see the effect of divalent ions on the polymer solution viscosity, parallel experiments were performed in a mixture of CaCl₂-NaCl of the same ionic strength as 5 wt % NaCl. The polymers without IBA showed severe viscosity reduction after aging for 90 days in both types of preparation (5 wt % NaCl or CaCl₂-NaCl). In the presence of IBA, viscosity was increased when aging time was increased for 5 wt % NaCl. In CaCl₂-NaCl, on the other hand, a viscosity reduction was observed as aging time was increased. This behavior was observed for all polymers except AN132 VHM.
    Matched MeSH terms: Acrylic Resins
  3. Akbari S, Mahmood SM, Tan IM, Ghaedi H, Ling OL
    Polymers (Basel), 2017 Nov 27;9(12).
    PMID: 30965947 DOI: 10.3390/polym9120647
    This research aims to test four new polymers for their stability under high salinity/high hardness conditions for their possible use in polymer flooding to improve oil recovery from hydrocarbon reservoirs. The four sulfonated based polyacrylamide co-polymers were FLOCOMB C7035; SUPERPUSHER SAV55; THERMOASSOCIATIF; and AN132 VHM which are basically sulfonated polyacrylamide copolymers of AM (acrylamide) with AMPS (2-Acrylamido-2-Methylpropane Sulfonate). AN132 VHM has a molecular weight of 9⁻11 million Daltons with 32 mol % degree of sulfonation. SUPERPUSHER SAV55 mainly has about 35 mol % sulfonation degree and a molecular weight of 9⁻11 million Daltons. FLOCOMB C7035, in addition, has undergone post-hydrolysis step to increase polydispersity and molecular weight above 18 million Daltons but it has a sulfonation degree much lower than 32 mol %. THERMOASSOCIATIF has a molecular weight lower than 12 million Daltons and a medium sulfonation degree of around 32 mol %, and also contains LCST (lower critical solution temperature) type block, which is responsible for its thermoassociative characteristics. This paper discusses the rheological behavior of these polymers in aqueous solutions (100⁻4500 ppm) with NaCl (0.1⁻10 wt %) measured at 25 °C. The effect of hardness was investigated by preparing a CaCl₂-NaCl solution of same ionic strength as the 5 wt % of NaCl. In summary, it can be concluded that the rheological behavior of the newly modified co-polymers was in general agreement to the existing polymers, except that THERMOASSOCIATIF polymers showed unique behavior, which could possibly make them a better candidate for enhanced oil recovery (EOR) application in high salinity conditions. The other three polymers, on the other hand, are better candidates for EOR applications in reservoirs containing high divalent ions. These results are expected to be helpful in selecting and screening the polymers for an EOR application.
    Matched MeSH terms: Acrylic Resins
  4. Teo KT, Hassan A, Gan SN
    Polymers (Basel), 2018 Dec 11;10(12).
    PMID: 30961299 DOI: 10.3390/polym10121374
    Palm fatty acid distillate (PFAD), is a by-product of the crude palm oil refining process. It comprises mainly of free fatty acids-around 45% palmitic and 33% oleic acids-as the major components. Ultra-violet (UV) curable urethane acrylate (UA) oligomers could be synthesized from PFAD, by the following procedure. A hydroxyl terminated macromer was first prepared by reacting PFAD with a mixture of isophthalic acid, phthalic anhydride, neopentagylcol (NPG), and pentaerythritol. The macromer was then reacted with 2-hydroxylethylacrylate (2HEA) and toluene diisocynate (TDI) to generate a resin, containing acrylate side chains for UV curable application. A series of UA resins were prepared by using 15, 25, 45, 55, and 70% of PFAD, respectively. The UA resin has Mw in the range of 3,200 to 27,000. They could be cured by UV irradiation at an intensity of 225 mW/cm². Glass transition temperature (Tg) of the cured film was measured by differential scanning calorimeter (DSC), and hardness of the film was determined by a pendulum hardness tester, according to American Society for Testing and Materials (ASTM)4366. The resins were used in a wood-coating application. All of the cured films showed good adhesion, hardness, and chemical resistance except for the one using the 70% PFAD, which did not cure properly.
    Matched MeSH terms: Acrylic Resins
  5. Liew CW, Ng HM, Numan A, Ramesh S
    Polymers (Basel), 2016 May 18;8(5).
    PMID: 30979292 DOI: 10.3390/polym8050179
    Nanocomposite polymer electrolyte membranes (NCPEMs) based on poly(acrylic acid)(PAA) and titania (TiO₂) are prepared by a solution casting technique. The ionic conductivity of NCPEMs increases with the weight ratio of TiO₂.The highest ionic conductivity of (8.36 ± 0.01) × 10-4 S·cm-1 is obtained with addition of 6 wt % of TiO₂ at ambient temperature. The complexation between PAA, LiTFSI and TiO₂ is discussed in Attenuated total reflectance-Fourier Transform Infrared (ATR-FTIR) studies. Electrical double layer capacitors (EDLCs) are fabricated using the filler-free polymer electrolyte or the most conducting NCPEM and carbon-based electrodes. The electrochemical performances of fabricated EDLCs are studied through cyclic voltammetry (CV) and galvanostatic charge-discharge studies. EDLC comprising NCPEM shows the specific capacitance of 28.56 F·g-1 (or equivalent to 29.54 mF·cm-2) with excellent electrochemical stability.
    Matched MeSH terms: Acrylic Resins
  6. Abdulkader YC, Kamaruddin AF, Mydin RBSMN
    Saudi Dent J, 2020 Sep;32(6):306-313.
    PMID: 32874071 DOI: 10.1016/j.sdentj.2019.09.010
    Objectives: This study compared the effects of normal salivary pH, and acidic pH found in patients with poor oral hygiene, on the durability of aesthetic archwire coated with epoxy resin and polytetrafluoroethylene (PTFE).

    Methods: The posterior parts of the archwires were sectioned into 20 mm segments (N = 102) and divided among six groups. Four groups were treated with different pH levels and two served as controls. The specimens were immersed in individual test tubes containing 10 ml of artificial saliva adjusted to a pH of 6.75 or 3.5. The tubes were sealed and stored in a 37 °C water bath for 28 days. After 28 days, the specimens were ligated to brackets embedded in an acrylic block and subjected to mechanical stress using an electronic toothbrush for 210 s. The specimens were photographed, and images were measured for coating loss using AutoCAD® software. Surface morphology was observed using a scanning electron microscope (SEM).

    Results: Significant coating loss (p 

    Matched MeSH terms: Acrylic Resins
  7. Zainal M, Mohamad Zain N, Mohd Amin I, Ahmad VN
    Saudi Dent J, 2021 Feb;33(2):105-111.
    PMID: 33551624 DOI: 10.1016/j.sdentj.2020.01.008
    The objective of this study is to determine the therapeutic efficacy of allicin against Candida albicans (C. albicans) and Staphylococcus aureus (S. aureus), the common etiological agents for denture stomatitis (DS). The minimum inhibitory concentration (MICs), minimum bactericidal concentrations (MBCs) and minimum fungicidal concentration (MFCs) of allicin were determined by the broth microdilution method followed by checkerboard microdilution method for a synergistic interaction between allicin + nystatin and allicin + CHX. The potential of allicin to eradicate C. albicans and S. aureus biofilms was assessed by treating biofilm formed on self- polymerized acrylic resin with allicin at a sub-MIC concentration for 5 min. The commercial denture cleanser (brand X) was used as a positive control. A Kruskal-Wallis test followed by the post-hoc Mann-Whitney U test was applied (SPSS 20.0), and the level of significance was set at P 
    Matched MeSH terms: Acrylic Resins
  8. Erni Noor, Al-Bayaty, Fouad Hussain, Muhammad Qadri Bin Mohd Shukri, Mohamad Syahir Bin Zulkiflee
    Compendium of Oral Science, 2019;6(1):15-25.
    MyJurnal
    Objective: To evaluate the root debridement skill in periodontology pre-clinical module among dental students and to estimate the effectiveness of conducting periodontology pre-clinical module before entering clinical module. Materials and Method: : A total of 47 pre-clinical dental students (Year 2) were included in this study. Single rooted extracted teeth were collected, mounted on acrylic resin and set into the level of 1/3 of the root length. Each of them were instructed to prepare a mounted teeth and to perform root debridement procedure on the labial surface of the tooth only within 10 minutes using Gracey curette #5/6. The similar samples were distributed back to the same students (which were already in clinical year (year 4) to repeat the same procedure on the lingual surface of the same tooth. Root surface roughness was evaluated by using scanning electron microscope (SEM) and profilometer for both labial and lingual surfaces. Statistical analysis was done using Mann-Whitney U test and T-test. Significance level of p ≤ 0.05 was assumed for all analysis. Results: SEM photomicrographs of root surfaces with magnifications of 100x and 800x revealed that there were incomplete removal of the dental calculus in both surfaces and significant roughness root surfaces noted. Conclusion: : No significant differences noted between the students’ root debridement skill in the pre-clinical and also clinical year. Objectives of the current module were fulfilled but in order to meet the highest standard, current module need to be improved in the future.
    Matched MeSH terms: Acrylic Resins
  9. Masudi, S.M., Padtong, E.A.
    MyJurnal
    The objective of this study was to evaluate and compare the effect of times elapsed on the application of a single-step adhesive system and activation of light cured subsequently placed composite to the bond strength between composites and adhesives. This was an experimental study using fifteen teeth extracted human premolars, which were caries and pathology free. Sample of teeth were embedded up to cemento-enamel junction on box of acrylic resin. All teeth were cut to obtain flat occlusal dentin surfaces. The specimens were randomly selected and divided into three groups with five teeth each. All the teeth were assigned to single-step bonding system AQ Bond (Sun Medical Co. Ltd., Shiga, Japan) according to manufacturer’s direction. Group 1 was left for 45 seconds, group 2 for 2 minutes, while group 3 was 5 minutes before putting subsequently restorative material. Composite resin was applied in 3 mm diameter and 6 mm height of cylinder mold and cured according to manufacturer’s direction on the dentin surface. Shear bond strength were measured using a testing system (Instron 8874, Instron Corp., Canton, MA, USA) at a crosshead speed of 2 mm/min with cell load capacity of 25 KN. The bond-strengths between single step adhesive system (AQ Bond) and light cured composites were tested. Mann-Whitney test showed no significant differences in bond-strength between Group 1 and Group 2. However, there were significantly differences (p
    Matched MeSH terms: Acrylic Resins
  10. Mek Zah Salleh, Khairiah Badri, Sahrim Ahmad, Mohd Hilmi Mahmood
    MyJurnal
    UV-curable hyperbranched urethane acrylate (HBPUA) from oleic acid of palm oil has been synthesized through a medium aided by p-toluene sulfonic acid as a catalyst. This mixture was then used as the core (HBP) and reacted with palm oil oleic acid to form the hyperbranched polyol (HBP-1). HBPUA was prepared by reacting HBP-1 resin with diisocyanate and hydroxyl-containing acrylate monomer with the presence of 0.1-2 wt% dibutyltin dilaurate as a catalyst. The reaction was confirmed by several analytical data i.e. hydroxyl value (OHV), Fourier Transform infrared (FTIR) spectroscopy, gel permeation chromatography (GPC) and nuclear magnetic resonance (NMR) spectroscopy analyses. The HBPUA was easily curable when subjected to ultraviolet (UV) radiation.
    Matched MeSH terms: Acrylic Resins
  11. Madihah Ahmad, Bohari M. Yamin, Azwan Mat Lazim
    MyJurnal
    α-Mangostin was extracted from the pericarp of the Malaysian local Garcinia mangostana linn., The structure was characterised by Infrared red, UV-Visible and Nuclear Magnetic Resonance spectroscopic data. The fluorescence peak at 500nm in ethanol was not observed in PNIPAM microgel solution. The increase of colloidal size of the gel in the presence of α-mangostin was studied by Dynamic Light Scattering and Transmission Electron Microscope. The size of the particle also increases with increasing temperature up to 45⁰C after which it began to shrink. The TEM micrograph at 45°C showed a uniformly structured pattern of the gel occurs in the range of the lowest solution critical temperature.
    Matched MeSH terms: Acrylic Resins
  12. Hairul Azman Roslan, Nur Hafizah Azizan, Rosmawati Saat
    The molecular genetic marker, minisatellite locus D1S80 (1p35-p36), is a highly polymorphic variable number of tandem repeats (VNTR). Its polymorphic nature allows for phylogenetic studies, forensic analysis, genetic maps construction and paternity testing to be performed. A study of the hypervariable locus D1S80 was conducted to determine the allele frequency and distribution of this locus in modern Malay in Sarawak population. The polymerase chain reaction technique was employed and results were analysed on polyacrylamide gel. A total of seventy-six DNA samples of unrelated Malay individuals in UNIMAS were collected and examined. The VNTR analysis of the D1S80 locus demonstrated the presence of 17 alleles in the Malay population. Allele with the size of 577 bp (27 repeats) was determined to be the most common in the sample population with the frequency of 0.1641, followed by allele with the size of 561 bp (26 repeats) and 529 bp (24 repeats) whose frequency is 0.1172 and 0.1094, respectively. The smallest allele is allele with the size of 465 bp (20 repeats) whereas the largest is allele with the size of 753 bp (38 repeats). The sample population exhibited 57.8% heterozygosity.
    Matched MeSH terms: Acrylic Resins
  13. Md. Isa K, Othman L, Osman Z
    Sains Malaysiana, 2011;40:1179-1186.
    Polymer electrolytes based on polyacrylonitrile (PAN) containing inorganic salts; lithium triflate (LiCF3SO3) and sodium triflate (NaCF3SO3) and ethylene carbonate (EC) as plasticizer were prepared using solvent casting technique. In this study, five systems of plasticized and unplasticized polymer electrolyte films i.e. PAN-EC, PAN-LiCF3SO3, PAN-NaCF3SO3 PAN-EC-LiCF3SO3 and PAN-EC-NaCF3SO3 systems have been prepared. The structural and morphological properties of the films were studied using infrared spectroscopy and scanning electron microscopy (SEM) while the conductivity study was done by using impedance spectroscopy. The infrared results revealed that interaction had taken place between the nitrogen atoms of PAN and Li+ and Na+ ions from the salts. SEM micrographs showed that the plasticized film, PAN-EC-NaCF3SO3 has bigger pores than PAN-EC-LiCF3SO3 film resulting in the film containing NaCF3SO3 salt being more conductive. On addition of salts and plasticizer, the conductivity of pure PAN increases to three orders of magnitude. The plasticized film containing NaCF3SO3 salt has a higher conductivity compared to that containing LiCF3SO3 salt. This result showed that the interaction between Li+-ion and the nitrogen atom of PAN was stronger than that of Na+-ion. The conductivity-temperature dependence of the highest conducting film from each system follows Arrhenius equation in the temperature range of 303 to 353 K. The conductivity-pressure study in the range of 0.01 - 0.09 MPa showed that the conductivity decreased when pressure was increased. This can be explained in term of free volume model.
    Matched MeSH terms: Acrylic Resins
  14. Lim SL, Ishak Ahmad, Azwan Mat Lazim
    Sains Malaysiana, 2015;44:779-785.
    The purpose of this study was to produce a novel pH sensitive hydrogel with superior thermal stability, composed of
    poly(acrylic acid) (PAA) and cellulose nanocrystal (CNC). CNC was extracted from kenaf fiber through a series of alkali
    and bleaching treatments followed by acid hydrolysis. PAA was then subjected to chemical cross-linking using the crosslinking
    agent (N,N-methylenebisacrylamide) in CNC suspension. The mixture was casted onto petri dish to obtain disc
    shape hydrogel. PAA/cellulose hydrogel with the same composition ratio were also prepared as control. The effect of
    reaction conditions such as the ratio of PAA and CNC on the swelling behavior of the hydrogel obtained towards pH
    was studied. The obtained hydrogel was further subjected to different tests such as thermogravimetric analysis (TGA) to
    study the thermal behavior, Fourier transform infrared for functional group identification and swelling test for swelling
    behavior at different pH. The cross-linking of PAA was verified with FTIR with the absence of C=C double bond. In TGA
    test, PAA/CNC hydrogel showed significantly higher thermal stability compared with pure PAA hydrogel. The hydrogel
    obtained showed excellent pH sensitivity and experienced maximum swelling at pH7. The PAA/CNC hydrogel can be
    developed further as drug carrier
    Matched MeSH terms: Acrylic Resins
  15. Prathibha B, Reddy PP, Anjum MS, Monica M, Praveen BH
    Dent Res J (Isfahan), 2019 2 13;16(1):36-41.
    PMID: 30745917
    Background: The aim of this study is comparing the retention and caries preventive effect of the glass-ionomer fissure sealant and resin-based fissure sealant.

    Materials and Methods: A randomized-controlled split-mouth study was conducted to compare the retention and the caries preventive effect of light-cured resin-based sealant (3M ESPE) and glass ionomer sealant (Fuji VII). The sealants were applied to either the right or the left lower mandibular molars (7-9 yrs of age) in 120 school children, based on the randomization process. They were recalled for assessment of clinical retention at intervals of 3, 6, and 12 months. The caries-preventive effect between the two materials was tested statistically by the McNemar's test for matched pairs, and the differences observed with regard to the retention of the materials was tested by Chi-square tests. The level of significance was set to be at P < 0.05.

    Results: At the end of 12th month, sealant retention is found to be higher in the resin-based sealant group compared to the glass ionomer group. In the glass ionomer sealants placed, 101 (91%) were caries-free and 10 (9%) had caries. In the resin-based sealant, 105 (94.60%) had sound teeth and 6 (5.4%) had dental caries (P = 0.34).

    Conclusion: The glass ionomer sealant was less retentive when compared to resin sealants. The caries incidence between the glass ionomer and resin-based sealants was not statistically significant.

    Matched MeSH terms: Acrylic Resins
  16. Ng IS, Ooi CW, Liu BL, Peng CT, Chiu CY, Chang YK
    Int J Biol Macromol, 2020 Jul 01;154:844-854.
    PMID: 32194127 DOI: 10.1016/j.ijbiomac.2020.03.127
    In this study, polyacrylonitrile (PAN) nanofiber membrane was prepared by an electrospinning technique. After alkaline hydrolysis, the ion-exchange nanofiber membrane (P-COOH) was grafted with chitosan molecules to form a chitosan-modified nanofiber membrane (P-COOH-CS). Poly(hexamethylene biguanide) (PHMB) was then covalently immobilized on P-COOH and P-COOH-CS to form P-COOH-PHMB and P-COOH-CS-PHMB, respectively. The nanofiber membranes were subjected to various surface analyses as well as to the evaluations of antibacterial activity against Escherichia coli. The optimal modification conditions for P-COOH-CS-PHMB were attained by water-soluble chitosan at 50 kDa of molecular weight, coupling pH at 7, and 0.05% (w/w) of PHMB. Within 10 min of treatment, the antibacterial rate was close to 100%. Under the similar conditions of antibacterial treatment, the P-COOH-CS-PHMB exhibited a better antibacterial efficacy than the P-COOH-PHMB. When the number of bacterial cells was increased by 2000 folds, both types of nanofiber membranes still maintained the antibacterial rate close to 100%. After five cycles of repeated antibacterial treatment, the antibacterial efficacy of P-COOH-PHMB was 96%, which was higher than that of P-COOH-CS-PHMB (83%). The experimental results revealed that the PHMB-modified nanofiber membranes can be suitably applied in water treatment such as water disinfection and biofouling control.
    Matched MeSH terms: Acrylic Resins
  17. Naganthran A, Masomian M, Rahman RNZRA, Ali MSM, Nooh HM
    Molecules, 2017 Sep 19;22(9).
    PMID: 28925972 DOI: 10.3390/molecules22091577
    The use of T1 lipase in automatic dishwashing detergent (ADD) is well established, but efficiency in hard water is very low. A new enzymatic environmentally-friendly dishwashing was formulated to be efficient in both soft and hard water. Thermostable enzymes such as T1 lipase from Geobacillus strain T1, Rand protease from Bacillussubtilis strain Rand, and Maltogenic amylase from Geobacillus sp. SK70 were produced and evaluated for an automatic dishwashing detergent formulation. The components of the new ADD were optimized for compatibility with these three enzymes. In compatibility tests of the enzymes with different components, several criteria were considered. The enzymes were mostly stable in non-ionic surfactants, especially polyhydric alcohols, Glucopon UP 600, and in a mixture of sodium carbonate and glycine (30:70) buffer at a pH of 9.25. Sodium polyacrylate and sodium citrate were used in the ADD formulation as a dispersing agent and a builder, respectively. Dishwashing performance of the formulated ADDs was evaluated in terms of percent of soil removed using the Leenert's Improved Detergency Tester. The results showed that the combination of different hydrolysis enzymes could improve the washing efficiency of formulated ADD compared to the commercial ADD "Finish" at 40 and 50 C.
    Matched MeSH terms: Acrylic Resins
  18. Kannaiyan K, Rakshit P, Bhat MPS, Sadasiva SKK, Babu SC, Ummer H
    J Contemp Dent Pract, 2023 Nov 01;24(11):891-894.
    PMID: 38238278 DOI: 10.5005/jp-journals-10024-3563
    AIM: The current study aimed to determine the impact of three different disinfectants on the surface roughness and color stability of heat-cure acrylic denture material.

    MATERIALS AND METHODS: Using a stainless-steel mold, disc-shaped wax patterns with dimensions of 10 mm in diameter and 2 mm thick (in accordance with ADA Specification No. 12) were created and prepared for a total of 75 acrylic samples. Dimensions of all 75 acrylic samples were checked with a digital Vernier caliper. About 25 samples of denture base material were immersed in three different chemical disinfectants: Group I: immersed in chlorhexidine gluconate solution, group II: immersed in sodium hypochlorite solution, and group III: immersed in glutaraldehyde solution. All samples were scrubbed daily for 1 minute with the appropriate disinfectant and submerged for 10 minutes in the same disinfectant. Between disinfection cycles, samples were kept in distilled water at 37°C. Color stability was measured using a reflection spectrophotometer. Surface roughness values were measured by a profilometer at baseline following 15 days and 30 days.

    RESULTS: After 15 days, the color stability was better in chlorhexidine gluconate solution group (4.88 ± 0.24) than sodium hypochlorite solution (4.74 ± 0.18) and glutaraldehyde solution group (4.46 ± 0.16). The mean surface roughness was less in glutaraldehyde solution group (2.10 ± 0.19), followed by chlorhexidine gluconate solution group (2.48 ± 0.09) and sodium hypochlorite solution group (2.64 ± 0.03). After 30 days, the color stability was significantly better in chlorhexidine gluconate solution group (4.40 ± 0.02), followed by sodium hypochlorite solution (4.06 ± 0.16) and glutaraldehyde solution group (3.87 ± 0.17). The mean surface roughness was significantly lesser in glutaraldehyde solution group (2.41 ± 0.14), followed by chlorhexidine gluconate solution group (2.94 ± 0.08) and sodium hypochlorite solution group (3.02 ± 0.13).

    CONCLUSION: In conclusion, the color stability was significantly better in chlorhexidine gluconate solution group than sodium hypochlorite solution and glutaraldehyde solution group. But the surface roughness was significantly lesser in the glutaraldehyde solution group, followed by the chlorhexidine gluconate and sodium hypochlorite solution group.

    CLINICAL SIGNIFICANCE: The maintenance of the prosthesis requires the use of a denture disinfectant; therefore, it is crucial to select one that is effective but would not have a negative impact on the denture base resin's inherent characteristics over time. How to cite this article: Kannaiyan K, Rakshit P, Bhat MPS, et al. Effect of Different Disinfecting Agents on Surface Roughness and Color Stability of Heat-cure Acrylic Denture Material: An In Vitro Study. J Contemp Dent Pract 2023;24(11):891-894.

    Matched MeSH terms: Acrylic Resins
  19. Baig MR, Ariff FT, Yunus N
    Indian J Dent Res, 2011 Mar-Apr;22(2):210-2.
    PMID: 21891887 DOI: 10.4103/0970-9290.84288
    BACKGROUND: The clinical success of relining depends on the ability of reline resin to bond to denture base. Surface preparations may influence reline bond strength of urethane-based dimethacrylate denture base resin.
    AIM: To investigate the effect of bur preparation on the surface roughness (R a ) of eclipse denture base resin and its shear bond strength (SBS) to an intra-oral self-curing reline material. The mode of reline bonding failure was also examined.
    MATERIALS AND METHODS: Twenty-four cylindrical Eclipse™ specimens were prepared and separated into three groups of eight specimens each. Two groups were subjected to mechanical preparation using standard and fine tungsten carbide (TC) burs and the third group (control) was left unprepared. The R a of all specimens was measured using a contact stylus profilometer. Subsequently, relining was done on the prepared surface and SBS testing was carried out a day later using a universal testing machine.
    RESULTS: One-way ANOVA revealed significant differences (P<0.05) in R a and SBS values for all the groups. Post-hoc Tukey's HSD test showed significant differences (P<0.05) between all the groups in the R a values. For SBS also there were significant differences (P<0.05), except between standard bur and control.
    CONCLUSIONS: 1) There was a statistically significant difference in the R a of Eclipse™ specimens prepared using different carbide burs (P<0.05). 2) There was a statistically significant difference in the relined SBS (P<0.05) when prepared using different burs, but the difference between the standard bur and the control group was not statistically significant.
    Matched MeSH terms: Acrylic Resins/chemistry
  20. Lim AK, Goh PP, Azura R, Mariam I
    J Cataract Refract Surg, 2011 Apr;37(4):655-9.
    PMID: 21420589 DOI: 10.1016/j.jcrs.2010.10.050
    PURPOSE: To determine the prevalence of and risk factors for AcriFlex 50CSE hydrophilic acrylic intraocular lens (IOL) opacification approximately 3 years after implantation.
    SETTING: Selayang Hospital, Selangor, Malaysia.
    DESIGN: Cross-sectional study.
    METHODS: Patients who had AcriFlex 50CSE IOL implantation in 2005 and 2006 were identified from operating logbooks and recalled via telephone and letters. Opaque IOLs were explanted and sent for scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS).
    RESULTS: The review showed that 18 patients had died and 67 had declined examination or could not be contacted, leaving 239 eyes for evaluation. The age of the patients ranged from 25 to 85 years. Of the patients, 83 (34.7%) were Malay, 127 (53.1%) Chinese, and 29 (12.1%) East Indian. The male:female ratio was 1:1. Fourteen eyes of 13 patients (5.4%) had IOL opacification; 1 had bilateral opacification. Five eyes had fine deposits, and 9 eyes had dense opaque deposits. Seven opaque IOLs required explantation. There was no correlation between age (P=.645), sex (P=.319), or race (P=.860) and IOL opacification. Pearson chi-square analysis showed a strong association between diabetes mellitus and IOL opacification (P=.019). Nine (69.2%) of the 13 patients with opacification had diabetes. Scanning electron microscopy and EDS showed calcium and phosphate deposits on the optic surface and intralenticularly near the anterior surface of the optic.
    CONCLUSIONS: Results indicate that diabetes mellitus is a risk factor for AcriFlex hydrophilic acrylic IOL opacification. In some cases, opacification affected vision, necessitating explantation. The pathophysiology of this complication is unknown.
    FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
    Matched MeSH terms: Acrylic Resins*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links