Displaying publications 61 - 80 of 191 in total

Abstract:
Sort:
  1. Hill SD, Aryal A, Pawley MDM, Ji W
    Integr Zool, 2018 Mar;13(2):194-205.
    PMID: 29078034 DOI: 10.1111/1749-4877.12284
    Song plays a fundamental role in intraspecific communication in songbirds. The temporal and structural components of songs can vary in different habitats. These include urban habitats where anthropogenic sounds and alteration of habitat structure can significantly affect songbird vocal behavior. Urban-rural variations in song complexity, song length and syllable rate are not fully understood. In this study, using the oriental magpie-robin (Copsychus saularis) as a model, we investigated urban-rural variation in song complexity, song length, syllable rate, syllable length and inter-syllable interval. Comparing urban and rural songs from 7 countries across its natural Asiatic range (Bangladesh, India, Malaysia, Nepal, Singapore, Sri Lanka and Thailand), we found no significant differences in oriental magpie-robin song complexity. However, we found significant differences in temporal song variables between urban and rural sites. Longer songs and inter-syllable intervals in addition to slower syllable rates within urban sites contributed the most to this variance. This indicates that the urban environment may have driven production of longer and slower songs to maximize efficient transmission of important song information in urban habitats.
    Matched MeSH terms: Noise
  2. Lu TS, Flaherty GT
    J Travel Med, 2018 01 01;25(1).
    PMID: 30346571 DOI: 10.1093/jtm/tay106
    Matched MeSH terms: Hearing Loss, Noise-Induced/prevention & control*
  3. Noraidah Ismail, Sarah Rahmat
    MyJurnal
    This paper aims to synthesize available literature on occupational noise in Malaysia and to relate this to the current noise management practices and control. The review focuses on several main
    scopes; i) history of occupational noise management in Malaysia; ii) legislative developments and legal precedents of occupational noise in Malaysia ; and iii) the hearing conservation programs (HCP) and hearing loss prevention programs (HLPP). Narrative review and synthesis. Related publications and references were identified through several ways: i) by structured searches in PubMed, Google scholar, Web of Knowledge and Science Direct using the combinations of ‘occupational noise’, ‘noise induced hearing loss; ‘hearing’, ‘knowledge’, awareness’, ‘hearing conservation program’, ‘hearing protection devices’ as key words ii) by inspecting the reference lists of relevant articles. The number of publications within the audiology which address this topic, is rather limited. All the above mentioned scopes were discussed and synthesis of literature from other related fields such as medical, health and occupational safety and health were also referred to facilitate the discussion. This paper concludes that there are an emerging trend for the studies of occupational noise Malaysia in the literature. However, the effectiveness of HCP in Malaysia, and to what extent it is accepted and being implemented is yet to be investigated.
    Matched MeSH terms: Hearing Loss, Noise-Induced; Noise, Occupational
  4. Asaritaminaziah binti Hisam, Siti Marwanis binti Anua
    MyJurnal
    Workers who are exposed to high noise level were at risk of noise-induced hearing loss (NIHL). This crosssectional study was conducted to investigate the noise exposure level and hearing symptoms among workers exposed to noise in a teaching hospital. Utilising convenience sampling method, 20 laundry workers and 17 mechanical cutters were recruited into this study. Noise exposure levels were measured using noise dosimeter for 8 hours and information on hearing symptoms were gathered using a modified questionnaire adopted from the American Speech Language Hearing Association (ASHA). A significantly higher mean noise level (85±2 dB(A)) was reported among mechanical cutters as compared to laundry workers (80±3 dB(A)), p=0.001 although the former had shorter duration of noise exposure (20±3 hours per week vs. 28±12 hours per week). Fourteen (70%) laundry workers and six (35%) mechanical cutters had reported having hearing problem in noisy background. Higher proportion of laundry workers (n=8, 57%) had reported hearing symptoms compared to mechanical cutters (n=6, 43%) and longer work years was found to be significantly associated with hearing symptoms (p=0.049). There is a need of appropriate education and training on noise exposure, NIHL and hearing protection devices usage in the workplaces
    Matched MeSH terms: Hearing Loss, Noise-Induced; Noise, Occupational
  5. Siti Nur Masturah Abdul Malek, Sayed Inayatullah Shah
    MyJurnal
    In ultrasound imaging there is compromise between the penetration of signal at certain depths into the object and image resolution as the ultrasound probe only can transmit single frequency signals in one transmission. Using curvilinear ultrasound probe with 2 to 5 MHz frequency bandwidth, this study investigated the use of multi-frequency imaging to enhance the quality of phantom images.
    Methods: Siemen Acuson X150 with curvilinear ultrasound transducer was used to scan the organs of interest (kidney, gallbladder and pancreas) of the ultrasound abdominal phantom. Different images at the different selected frequencies (2.5, 3.6 and 5.0 MHz) were created by fixing the position and the orientation of the transducer in each of the scanning process. Different-frequency images were generated and combined to produce composite (multi-frequency) image. Results: In this study, the quality of the composite image was evaluated based on signal-to noise ratio (SNR) and the obtained results were compared with the single frequency images. Besides, the comparison was also made in terms of overall image quality (noise and sharpness of organ outline) through perceived image quality analysis. Based on calculated SNR, the composite image of the kidney, gallbladder and pancreas recorded higher SNR value as compared to the single frequency images. However, through perceived image quality, most of the observers viewed that the quality of the composite image of the kidney, gallbladder and pancreas is poor as compared to the single frequency image. Conclusions: Image quality of ultrasound imaging is improved by combining multiple ultrasound frequency images into a single composite image. This is achieved as high SNR is obtained in the composite image. However, through perceived image quality, the overall image quality of the composite image was poor.
    Matched MeSH terms: Signal-To-Noise Ratio
  6. Bilal M, Shah JA, Qureshi IM, Kadir K
    Int J Biomed Imaging, 2018;2018:7803067.
    PMID: 29610569 DOI: 10.1155/2018/7803067
    Transformed domain sparsity of Magnetic Resonance Imaging (MRI) has recently been used to reduce the acquisition time in conjunction with compressed sensing (CS) theory. Respiratory motion during MR scan results in strong blurring and ghosting artifacts in recovered MR images. To improve the quality of the recovered images, motion needs to be estimated and corrected. In this article, a two-step approach is proposed for the recovery of cardiac MR images in the presence of free breathing motion. In the first step, compressively sampled MR images are recovered by solving an optimization problem using gradient descent algorithm. TheL1-norm based regularizer, used in optimization problem, is approximated by a hyperbolic tangent function. In the second step, a block matching algorithm, known as Adaptive Rood Pattern Search (ARPS), is exploited to estimate and correct respiratory motion among the recovered images. The framework is tested for free breathing simulated andin vivo2D cardiac cine MRI data. Simulation results show improved structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and mean square error (MSE) with different acceleration factors for the proposed method. Experimental results also provide a comparison betweenk-tFOCUSS with MEMC and the proposed method.
    Matched MeSH terms: Signal-To-Noise Ratio
  7. Nashrah Maamor, Nurul Huda Bani, Wan Syafira Ishak, Siti Zamratol Mai-Sarah Mukari, Kalaivani Chellapan
    Jurnal Sains Kesihatan Malaysia, 2018;16(101):215-215.
    MyJurnal
    This paper describes the systematic process followed in the development of culturally appropriate equalized speech-in-noise sentences suitable for use in an adaptive Speech-In-Noise training protocol for adults in Malaysia. The process involved three iterative phases of development. They were (1) analysis, (2) design and (3) development phases. In the analysis phase, important variables that needed to be considered for speech-in-noise materials were identified through literature review and discussion with the experts in the field. Next, in the design phase, the compilation and formation of sentences, evaluation of naturalness and recording of the speech materials were done. The last phase was the development phase which involved the evaluation of performance intensity function and equalization of intelligibility. The final outcome of these phases were 171 sentences with equal intelligibility that can be used interchangeably in a speech-in-noise training protocol for adults in Malaysia.
    Matched MeSH terms: Noise
  8. Ahmad Nazlim Yusoff, Khairiah Abdul Hamid, Farah Nabila Ab Rahman, Mazlyfarina Mohamad, Khairiah Abdul Hamid, Siti Zamratol-Mai Sarah Mukari
    MyJurnal
    In this study, the asymmetry of the main effects of action, background and tonal frequency during a pitch memory processing
    were investigated by means of brain activation. Eighteen participants (mean age 27.6 years) were presented with low and
    high frequency tones in quiet and in noise. They listen, discriminate and recognize the target tone against the final tone
    in a series of four distracting tones. The main effects were studied using the analysis of variance (ANOVA) with action (to
    wring (rubber bulb) vs. not to wring), background (in quiet vs. in noise) and frequency (low vs. high) as the factors (and
    levels respectively). The main effect of action is in the right pre-central gyrus (PCG), in conformation with its contralateral
    behavior. The main effect of background indicated the bilateral primary auditory cortices (PAC) and is right lateralized,
    attributable to white noise. The main effect of frequency is also observed in PAC but bilaterally equal and attributable to
    low frequency tones. Despite the argument that the temporo-spectral lateralization dichotomy is not especially rigid as
    revealed by the main effect of frequency, right lateralization of PAC for the respective main effect of background clearly
    demonstrates its functional asymmetry suggesting different perceptual functionality of the right and left PAC.
    Matched MeSH terms: Noise
  9. Guest H, Dewey RS, Plack CJ, Couth S, Prendergast G, Bakay W, et al.
    Trends Hear, 2018;22:2331216518803213.
    PMID: 30295145 DOI: 10.1177/2331216518803213
    Lifetime noise exposure is generally quantified by self-report. The accuracy of retrospective self-report is limited by respondent recall but is also bound to be influenced by reporting procedures. Such procedures are of variable quality in current measures of lifetime noise exposure, and off-the-shelf instruments are not readily available. The Noise Exposure Structured Interview (NESI) represents an attempt to draw together some of the stronger elements of existing procedures and to provide solutions to their outstanding limitations. Reporting is not restricted to prespecified exposure activities and instead encompasses all activities that the respondent has experienced as noisy (defined based on sound level estimated from vocal effort). Changing exposure habits over time are reported by dividing the lifespan into discrete periods in which exposure habits were approximately stable, with life milestones used to aid recall. Exposure duration, sound level, and use of hearing protection are reported for each life period separately. Simple-to-follow methods are provided for the estimation of free-field sound level, the sound level emitted by personal listening devices, and the attenuation provided by hearing protective equipment. An energy-based means of combining the resulting data is supplied, along with a primarily energy-based method for incorporating firearm-noise exposure. Finally, the NESI acknowledges the need of some users to tailor the procedures; this flexibility is afforded, and reasonable modifications are described. Competency needs of new users are addressed through detailed interview instructions (including troubleshooting tips) and a demonstration video. Limited evaluation data are available, and future efforts at evaluation are proposed.
    Matched MeSH terms: Hearing Loss, Noise-Induced/diagnosis*; Hearing Loss, Noise-Induced/epidemiology*; Noise, Occupational/adverse effects*
  10. Zakaria MN, Abdul Wahab NA, Awang MA
    Noise Health, 2017 12 2;19(87):112-113.
    PMID: 29192621 DOI: 10.4103/nah.NAH_2_17
    Matched MeSH terms: Noise, Occupational*
  11. Billings CJ, Grush LD, Maamor N
    Physiol Rep, 2017 Nov;5(20).
    PMID: 29051305 DOI: 10.14814/phy2.13464
    The effects of background noise on speech-evoked cortical auditory evoked potentials (CAEPs) can provide insight into the physiology of the auditory system. The purpose of this study was to determine background noise effects on neural coding of different phonemes within a syllable. CAEPs were recorded from 15 young normal-hearing adults in response to speech signals /s/, /ɑ/, and /sɑ/. Signals were presented at varying signal-to-noise ratios (SNRs). The effects of SNR and context (in isolation or within syllable) were analyzed for both phonemes. For all three stimuli, latencies generally decreased and amplitudes generally increased as SNR improved, and context effects were not present; however, the amplitude of the /ɑ/ response was the exception, showing no SNR effect and a significant context effect. Differential coding of /s/ and /ɑ/ likely result from level and timing differences. Neural refractoriness may result in the lack of a robust SNR effect on amplitude in the syllable context. The stable amplitude across SNRs in response to the vowel in /sɑ/ suggests the combined effects of (1) acoustic characteristics of the syllable and noise at poor SNRs and (2) refractory effects resulting from phoneme timing at good SNRs. Results provide insights into the coding of multiple-onset speech syllables in varying levels of background noise and, together with behavioral measures, may help to improve our understanding of speech-perception-in-noise difficulties.
    Matched MeSH terms: Signal-To-Noise Ratio
  12. Kamaruddin NH, Bakar AAA, Mobarak NN, Zan MSD, Arsad N
    Sensors (Basel), 2017 Oct 06;17(10).
    PMID: 28984826 DOI: 10.3390/s17102277
    The study of binding affinity is essential in surface plasmon resonance (SPR) sensing because it allows researchers to quantify the affinity between the analyte and immobilised ligands of an SPR sensor. In this study, we demonstrate the derivation of the binding affinity constant, K, for Pb2+and Hg2+ions according to their SPR response using a gold/silver/gold/chitosan-graphene oxide (Au/Ag/Au/CS-GO) sensor for the concentration range of 0.1-5 ppm. The higher affinity of Pb2+to binding with the CS-GO sensor explains the outstanding sensitivity of 2.05 °ppm-1against 1.66 °ppm-1of Hg2+. The maximum signal-to-noise ratio (SNR) upon detection of Pb2+is 1.53, and exceeds the suggested logical criterion of an SNR. The Au/Ag/Au/CS-GO SPR sensor also exhibits excellent repeatability in Pb2+due to the strong bond between its functional groups and this cation. The adsorption data of Pb2+and Hg2+on the CS-GO sensor fits well with the Langmuir isotherm model where the affinity constant, K, of Pb2+and Hg2+ions is computed. The affinity of Pb2+ions to the Au/Ag/Au/CS-GO sensor is significantly higher than that of Hg2+based on the value of K, 7 × 10⁵ M-1and 4 × 10⁵ M-1, respectively. The higher shift in SPR angles due to Pb2+and Hg2+compared to Cr3+, Cu2+and Zn2+ions also reveals the greater affinity of the CS-GO SPR sensor to them, thus supporting the rationale for obtaining K for these two heavy metals. This study provides a better understanding on the sensing performance of such sensors in detecting heavy metal ions.
    Matched MeSH terms: Signal-To-Noise Ratio
  13. Manakandan SK, Rosnah I, Mohd Ridhuan J, Priya R
    Med J Malaysia, 2017 08;72(4):228-235.
    PMID: 28889134 MyJurnal
    BACKGROUND: The most crucial step in forming a set of survey questionnaire is deciding the appropriate items in a construct. Retaining irrelevant items and removing important items will certainly mislead the direction of a particular study. This article demonstrates Fuzzy Delphi method as one of the scientific analysis technique to consolidate consensus agreement within a panel of experts pertaining to each item's appropriateness. This method reduces the ambiguity, diversity, and discrepancy of the opinions among the experts hence enhances the quality of the selected items. The main purpose of this study was to obtain experts' consensus on the suitability of the preselected items on the questionnaire.

    METHODS: The panel consists of sixteen experts from the Occupational and Environmental Health Unit of Ministry of Health, Vector-borne Disease Control Unit of Ministry of Health and Occupational and Safety Health Unit of both public and private universities. A set of questionnaires related to noise and chemical exposure were compiled based on the literature search. There was a total of six constructs with 60 items in which three constructs for knowledge, attitude, and practice of noise exposure and three constructs for knowledge, attitude, and practice of chemical exposure. The validation process replicated recent Fuzzy Delphi method that using a concept of Triangular Fuzzy Numbers and Defuzzification process.

    RESULTS: A 100% response rate was obtained from all the sixteen experts with an average Likert scoring of four to five. Post FDM analysis, the first prerequisite was fulfilled with a threshold value (d) ≤ 0.2, hence all the six constructs were accepted. For the second prerequisite, three items (21%) from noise-attitude construct and four items (40%) from chemical-practice construct had expert consensus lesser than 75%, which giving rise to about 12% from the total items in the questionnaire. The third prerequisite was used to rank the items within the constructs by calculating the average fuzzy numbers. The seven items which did not fulfill the second prerequisite similarly had lower ranks during the analysis, therefore those items were discarded from the final draft.

    CONCLUSION: Post FDM analysis, the experts' consensus on the suitability of the pre-selected items on the questionnaire set were obtained, hence it is now ready for further construct validation process.

    Matched MeSH terms: Noise, Occupational/adverse effects
  14. Al-Qazzaz NK, Hamid Bin Mohd Ali S, Ahmad SA, Islam MS, Escudero J
    Sensors (Basel), 2017 Jun 08;17(6).
    PMID: 28594352 DOI: 10.3390/s17061326
    Characterizing dementia is a global challenge in supporting personalized health care. The electroencephalogram (EEG) is a promising tool to support the diagnosis and evaluation of abnormalities in the human brain. The EEG sensors record the brain activity directly with excellent time resolution. In this study, EEG sensor with 19 electrodes were used to test the background activities of the brains of five vascular dementia (VaD), 15 stroke-related patients with mild cognitive impairment (MCI), and 15 healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the recorded EEG signals using a novel technique that combines automatic independent component analysis (AICA) and wavelet transform (WT), that is, the AICA-WT technique; second, it aims to extract and investigate the spectral features that characterize the post-stroke dementia patients compared to the control subjects. The proposed AICA-WT technique is a four-stage approach. In the first stage, the independent components (ICs) were estimated. In the second stage, three-step artifact identification metrics were applied to detect the artifactual components. The components identified as artifacts were marked as critical and denoised through DWT in the third stage. In the fourth stage, the corrected ICs were reconstructed to obtain artifact-free EEG signals. The performance of the proposed AICA-WT technique was compared with those of two other techniques based on AICA and WT denoising methods using cross-correlation X C o r r and peak signal to noise ratio ( P S N R ) (ANOVA, p ˂ 0.05). The AICA-WT technique exhibited the best artifact removal performance. The assumption that there would be a deceleration of EEG dominant frequencies in VaD and MCI patients compared with control subjects was assessed with AICA-WT (ANOVA, p ˂ 0.05). Therefore, this study may provide information on post-stroke dementia particularly VaD and stroke-related MCI patients through spectral analysis of EEG background activities that can help to provide useful diagnostic indexes by using EEG signal processing.
    Matched MeSH terms: Signal-To-Noise Ratio
  15. Alsaih K, Lemaitre G, Rastgoo M, Massich J, Sidibé D, Meriaudeau F
    Biomed Eng Online, 2017 Jun 07;16(1):68.
    PMID: 28592309 DOI: 10.1186/s12938-017-0352-9
    BACKGROUND: Spectral domain optical coherence tomography (OCT) (SD-OCT) is most widely imaging equipment used in ophthalmology to detect diabetic macular edema (DME). Indeed, it offers an accurate visualization of the morphology of the retina as well as the retina layers.

    METHODS: The dataset used in this study has been acquired by the Singapore Eye Research Institute (SERI), using CIRRUS TM (Carl Zeiss Meditec, Inc., Dublin, CA, USA) SD-OCT device. The dataset consists of 32 OCT volumes (16 DME and 16 normal cases). Each volume contains 128 B-scans with resolution of 1024 px × 512 px, resulting in more than 3800 images being processed. All SD-OCT volumes are read and assessed by trained graders and identified as normal or DME cases based on evaluation of retinal thickening, hard exudates, intraretinal cystoid space formation, and subretinal fluid. Within the DME sub-set, a large number of lesions has been selected to create a rather complete and diverse DME dataset. This paper presents an automatic classification framework for SD-OCT volumes in order to identify DME versus normal volumes. In this regard, a generic pipeline including pre-processing, feature detection, feature representation, and classification was investigated. More precisely, extraction of histogram of oriented gradients and local binary pattern (LBP) features within a multiresolution approach is used as well as principal component analysis (PCA) and bag of words (BoW) representations.

    RESULTS AND CONCLUSION: Besides comparing individual and combined features, different representation approaches and different classifiers are evaluated. The best results are obtained for LBP[Formula: see text] vectors while represented and classified using PCA and a linear-support vector machine (SVM), leading to a sensitivity(SE) and specificity (SP) of 87.5 and 87.5%, respectively.

    Matched MeSH terms: Signal-To-Noise Ratio
  16. Khor HL, Liew SC, Zain JM
    J Digit Imaging, 2017 Jun;30(3):328-349.
    PMID: 28050716 DOI: 10.1007/s10278-016-9930-9
    Tampering on medical image will lead to wrong diagnosis and treatment, which is life-threatening; therefore, digital watermarking on medical image was introduced to protect medical image from tampering. Medical images are divided into region of interest (ROI) and region of non-interest (RONI). ROI is an area that has a significant impact on diagnosis, whereas RONI has less or no significance in diagnosis. This paper has proposed ROI-based tamper detection and recovery watermarking scheme (ROI-DR) that embeds ROI bit information into RONI least significant bits, which will be extracted later for authentication and recovery process. The experiment result has shown that the ROI-DR has achieved a good result in imperceptibility with peak signal-to-noise ratio (PSNR) values approximately 48 dB, it is robust against various kinds of tampering, and the tampered ROI was able to recover to its original form. Lastly, a comparative table with the previous research (TALLOR and TALLOR-RS watermarking schemes) has been derived, where these three watermarking schemes were tested under the same testing conditions and environment. The experiment result has shown that ROI-DR has achieved speed-up factors of 22.55 and 26.65 in relative to TALLOR and TALLOR-RS watermarking schemes, respectively.
    Matched MeSH terms: Signal-To-Noise Ratio
  17. Chian TC, Nassir NM, Ibrahim MI, Yusof AK, Sabarudin A
    Quant Imaging Med Surg, 2017 Feb;7(1):48-58.
    PMID: 28275559 DOI: 10.21037/qims.2017.02.02
    BACKGROUND: This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols.

    METHODS: Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software.

    RESULTS: Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp.

    CONCLUSIONS: There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.

    Matched MeSH terms: Signal-To-Noise Ratio
  18. Quar TK, Soli SD, Chan YF, Ishak WS, Abdul Wahat NH
    Int J Audiol, 2017 02;56(2):92-98.
    PMID: 27686009 DOI: 10.1080/14992027.2016.1210828
    OBJECTIVE: This study was conducted to evaluate the speech perception of Malaysian Chinese adults using the Taiwanese Mandarin HINT (MHINT-T) and the Malay HINT (MyHINT).

    DESIGN: The MHINT-T and the MyHINT were presented in quiet and noise (front, right and left) conditions under headphones. Results for the two tests were compared with each other and with the norms for each test.

    STUDY SAMPLE: Malaysian Chinese native speakers of Mandarin (N = 58), 18-31 years of age with normal hearing.

    RESULTS: On average, subjects demonstrated poorer speech perception ability than the normative samples for these tests. Repeated measures ANOVA showed that speech reception thresholds (SRTs) were slightly poorer on the MHINT-T than on the MyHINT for all test conditions. However, normalized SRTs were poorer by 0.6 standard deviations for MyHINT as compared with MHINT-T.

    CONCLUSIONS: MyHINT and MHINT-T can be used as norm-referenced speech perception measures for Mandarin-speaking Chinese in Malaysia.

    Matched MeSH terms: Noise/adverse effects*
  19. Maamor N, Billings CJ
    Neurosci Lett, 2017 01 01;636:258-264.
    PMID: 27838448 DOI: 10.1016/j.neulet.2016.11.020
    The purpose of this study was to determine the effects of noise type, signal-to-noise ratio (SNR), age, and hearing status on cortical auditory evoked potentials (CAEPs) to speech sounds. This helps to explain the hearing-in-noise difficulties often seen in the aging and hearing impaired population. Continuous, modulated, and babble noise types were presented at varying SNRs to 30 individuals divided into three groups according to age and hearing status. Significant main effects of noise type, SNR, and group were found. Interaction effects revealed that the SNR effect varies as a function of noise type and is most systematic for continuous noise. Effects of age and hearing loss were limited to CAEP latency and were differentially modulated by energetic and informational-like masking. It is clear that the spectrotemporal characteristics of signals and noises play an important role in determining the morphology of neural responses. Participant factors such as age and hearing status, also play an important role in determining the brain's response to complex auditory stimuli and contribute to the ability to listen in noise.
    Matched MeSH terms: Signal-To-Noise Ratio*
  20. Lee, K.Y., Ho, L.Y., Tan, K.H., Tham, Y.Y., Ling, S.P., Qureshi, A.M., et al.
    MyJurnal
    In the perspective of recent bauxite mining in Malaysia, this review aims to identify the potential
    environmental and health impacts on miners and surrounding communities. The environmental issues of
    bauxite mining include, air, water and soil pollution due to bauxite dust; leaching of bauxite into water
    sources resulting in reduced soil fertility as well as affecting agricultural food products and aquatic life.
    Bauxite occupational exposure affects the health of miners, and has negative consequences on the health of
    surrounding communities, such as increased respiratory symptoms, contamination of drinking water, other
    potential health risks from ingestion of bauxite and heavy metals, including noise-induced hearing loss and
    mental stress. This review discusses the processes of bauxite mining, its constituents and residual trace
    elements, and their impact on the environment and health of exposed workers and communities. It also
    explores the Malaysian legal requirements and standards of occupational exposure to bauxite.
    Matched MeSH terms: Hearing Loss, Noise-Induced
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links