Displaying publications 61 - 67 of 67 in total

Abstract:
Sort:
  1. Osman, Z., Othman, L., Md Isa, K.B., Ahmad, A., Kamarulzaman, N.
    ASM Science Journal, 2010;4(1):55-61.
    MyJurnal
    In this study polymer electrolytes composed of poly(methyl methacrylate) (PMMA) as a host polymer and ethylene carbonate (EC) as a plasticizer complexed with different lithium salts, i.e. lithium tetrafluoroborate (LiBF4) and lithium triflate (LiCF3SO3) were prepared by the solution casting technique. The conductivities of the films were characterized by impedance spectroscopy. At room temperature, the highest conductivities were 4.07 × 10–7S cm–1 and 3.40 × 10–5 S cm–1 achieved, respectively from the films containing 30 wt% LiBF4 in the PMMA-EC-LiBF4 system and 35 wt% LiCF3SO3 in the PMMA-EC-LiCF3SO3 system. The conductivity-temperature dependence of the films seemed to obey the Arrhenius equation in which the ion transport in these materials was thermally assisted. Scanning electron microscopy analysis showed that the surface of PMMA-EC-LiCF3SO3 film was smooth and homogeneous, hence lithium ions could traverse through the PMMA-EC-LiCF3SO3 film more easily compared to the PMMA-EC-LiBF4 film. X-Ray diffraction studies revealed that complexation had occurred and the complexes formed were amorphous.
    Matched MeSH terms: Pharmaceutical Solutions
  2. Firdaus, M., Nor Sheereen, Z.
    MyJurnal
    Introduction: The purpose of the present study was to investigate exploratory factor analysis of the
    Beck Anxiety Inventory (BAI) and reports its reliability and validity in Malaysia. Method: One thousand
    and ninety participants from four different samples (namely students, general population, medical and
    psychiatric patients) completed the Malay version of Beck Anxiety Inventory, as well as additional
    questionnaires such as Fear Questionnaire, Anxiety Sensitivity Index, Depression Anxiety Stress Scale, and Catastrophic Cognition Questionnaire. Results: Exploratory factor analysis revealed a three factor solution and accounted for 48.01% of the total variance. The three-factor structure appeared to be; subjective anxiety, autonomic, and neurophysiology. The Cronbach alpha coefficients (α) ranged from 0.66 to 0.89 with satisfactory overall alpha value (.91). Evidence was also found acceptable concurrent validity of the BAI-Malay (range between r=.22 to r=.67). Conclusion: This study shows that the BAIMalay is a reliable and valid instrument to measure symptoms of anxiety in the Malay population
    and can be used in research and clinical service in Malaysia. However, replication of study by using
    confirmatory factor analysis and application of the instrument among anxiety patients worth of further
    investigation.
    Matched MeSH terms: Pharmaceutical Solutions
  3. Shodiya, S., Azhar, A. A., Darus, A. N.
    MyJurnal
    HCFCs, in addition to destroying the ozone layer, have been recognized as a contributing factor that increases global warming. It is widely used as working fluid in window air-conditioning system, where capillary tube serves as an expansion device. Literature reports have shown that no single refrigerant can solve the problem of ozone layer depletion and global warming. Refrigerant HC290/HC600a/HFC407C mixture, an eco-friendly refrigerant, has been recognized as an alternative to HCFC22. The objective of this study is to, for cost effectiveness, develop an empirical correlation to predict the refrigerant HC290/ HC600a/HFC407C mixture mass flow rate using statistical experimental design approach. A review of relevant literature shows that refrigerant’s mass flow rate depends on condensing temperature, degree of subcooling, inner diameter and length of capillary tube. The relationship between the mass flow rate and the four independent variables was established as an empirical mathematical correlation using central composite design (CCD), a response surface methodology (RSM). This empirical correlation was examined using analysis of variance (ANOVA) of 5% level of significance. The results of these analysis showed that the correlation fitted well with the experimental data yielding an average and standard deviation of 1.05% and 2.62%, respectively. The validity of the present correlation was further assessed by comparing it with published empirical correlation in literature and the result showed that the present correlation is consistent.
    Matched MeSH terms: Pharmaceutical Solutions
  4. Nooratiny, I., Sahilah, A.M., Alif Alfie, A.R., Mohd. Farouk, M.Y.
    MyJurnal
    A technique to isolate DNA from ghee was developed for the authentication of beef fat product. The method was based on pre-mixed ghee with phosphate buffer solution (PBS) prior to DNA extraction using Epicentre extraction method. The recovery of beef DNA was then analysed by polymerase chain reaction (PCR) using beef species-specific oligonucleotide primers which targeted the mitochondria DNA (mtDNA) of cytochrome b (cyt b) gene. The amplicon was 274 bp in size. The developed ghee extraction method offers a high yield of DNA providing 100 ng per μl and useful for validating beef fat product.
    Matched MeSH terms: Pharmaceutical Solutions
  5. Norhayati Mohd Noor, Aniza Abd Aziz
    MyJurnal
    The Short Form Health Survey SF-36 is a well-known generic health-related quality of life measure that has widely been used worldwide. However, given the cultural, social and ethnic differences in some countries, it might not follow the intended structure of the instrument. Hence, this study aims to determine the psychometric properties of the Malay version of Short Form Health Survey (SF-12) among postpartum mothers. A cross-sectional study was conducted among 1-month postpartum mothers attending Obstetric and Gynecology clinic, Universiti Sains Malaysia Hospital, Kelantan, Malaysia. Reliability was estimated using internal consistency and the factor structure was extracted by performing confirmatory factor analysis using SPSS v. 20 and AMOS v. 20. A total of 108 women responded. The mean (SD) score for the Physical Component Summary (PCS) score and Mental Component Summary (MCS) score were 43.3 (7.08) and 42.4 (6.87) respectively. The Cronbach alpha for PCS-12 was 0.749 and MCS-12 was 0.701. Spearman correlations of individual items and the SF-12 component summary scores showed PF, RP, BP and GH items correlated higher with the PCS score, whereas the VT, SF, RE, and MH items correlated higher with the MCS score lending support to its good convergent validity. The confirmatory factor solution showed final model with two factors structure and six items each with acceptable factor loadings, satisfactory absolute and parsimonious fitness (RMSEA=0.1, x2/df=2.4). The psychometric tests of the Malay version of SF-12 generally showed acceptable validity and reliability among postpartum women.
    Study site: Obstretic and gynecology Hospital Universiti Sains Malaysia (HUSM)
    Matched MeSH terms: Pharmaceutical Solutions
  6. Liew KB, Peh KK
    Pak J Pharm Sci, 2018 Nov;31(6):2515-2522.
    PMID: 30473526
    A stability-indicating HPLC-UV method for the simultaneous determination of sildenafil citrate and dapoxetine hydrochloride in solution and tablet was developed. The mobile phase was comprised of acetonitrile and 0.2M ammonium acetate buffer. The analyte was eluted at 3.392min and 7.255min for sildenafil citrate and dapoxetine HCl respectively using gradient system at a flow rate of 1.5mL/min. The theoretical plates count was>2000, tailing factor
    Matched MeSH terms: Pharmaceutical Solutions
  7. Ali HS, Khan S, York P, Shah SM, Khan J, Hussain Z, et al.
    Pak J Pharm Sci, 2017 Sep;30(5):1635-1643.
    PMID: 29084684
    Drug nanosuspensions have gained tremendous attraction as a platform in drug delivery. In the present work, a nanosuspension was prepared by a wet milling approach in order to increase saturation solubility and dissolution of the water insoluble drug, hydrocortisone. Size of the generated particeles was 290 nm ± 9 nm having a zeta potential of -1.9 mV ± 0.6 mV. Nanosized particles were found to have a rod shape with a narrow particle size distribution (PDI =0.17). Results of differential scanning calorimetry and X-ray diffraction analyses revealed minor modifications of crystallinity of hydrocortisone following the milling process. Solubility of hydrocortisone was enhanced by nanonization to 875µg/ml ±2.5, an almost 2.9-fold compared to the raw hydrocortisone. Moreover, the nanosuspension formulation substabtially enhanced the dissolution rate of hydrocortisone where >97% of the hydrocortisone was dissolved within 10 minutes opposed to 22.3% for the raw 50% for the raw hydrocortisone and the commercial tablet, respectively. The bioavailability study resulted in AUC 0-9h for HC nanosuspensions (31.50±2.50), which is significantly (p<0.05) higher compared to the AUC 0-9h (14.85±3.25) resulted for HC solution. The nanosuspension was physically stable at room temperature for 24 months.
    Matched MeSH terms: Pharmaceutical Solutions
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links