Displaying publications 81 - 100 of 123 in total

Abstract:
Sort:
  1. Ng AH, Ng KH, Dharmendra H, Perkins AC
    Appl Radiat Isot, 2009 Oct;67(10):1864-8.
    PMID: 19049851 DOI: 10.1016/j.apradiso.2008.10.010
    A simple sphere test phantom has been developed for routine performance testing of SPECT systems in situations where expensive commercial phantoms may not be available. The phantom was based on a design with six universal syringe hubs set in the frame to support a circular array of six glass blown spheres of different sizes. The frame was then placed into a water-filled CT abdomen phantom and scanned with a triple head camera system (Philips IRIX, USA). Comparison was made with a commercially available phantom (Deluxe Jaszczak phantom). Whereas the commercial phantom demonstrates cold spot resolution, an important advantage of the sphere test phantom was that hot spot resolution could be easily measured using almost half (370MBq) of the activity recommended for use in the commercial phantom. Results showed that the contrast increased non-linearly with sphere volume and radionuclide concentration. The phantom was found to be suitable as an inexpensive option for daily performance tests.
  2. How SH, Ng KH, Jamalludin AR, Shah A, Rathor Y
    Med J Malaysia, 2005 Dec;60(5):606-13.
    PMID: 16515112
    We conducted a retrospective review of 135 patients with melioidosis in Pahang from January 2000 to June 2003. Patients were mostly male (78.5%) and Malay (83%) with a median age of 51 years. Seventy four percent of patients were diabetic. Common presentations were pneumonia (40.7%), septicaemic without obvious source of infection (19.3%) and multiple organ involvement (15.6%). Only 32.7% were given appropriate antibiotics empirically. The overall mortality was 54% with most deaths (65%) occurring within 48 hours of admission. Patients with pneumonia, multiple organ involvement and septicaemic of unknown source had higher mortality as compared to patients with subcutaneous, musculoskeletal or single internal organ involvement without pneumonia (p < 0.001). The relapse rate was 19.2%.
  3. Ramli K, Abdullah BJ, Ng KH, Mahmud R, Hussain AF
    Australas Radiol, 2005 Dec;49(6):460-6.
    PMID: 16351609
    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P > 0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (chi(2) tests).
  4. Azlan CA, Ng KH, Anandan S, Nizam MS
    Australas Phys Eng Sci Med, 2006 Sep;29(3):278-80.
    PMID: 17058591
    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
  5. Lim CK, Yew KM, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2002 Sep;25(3):144-50.
    PMID: 12416592 DOI: 10.1007/BF03178776
    Development of computer-based medical inference systems is always confronted with some difficulties. In this paper, difficulties of designing an inference system for the diagnosis of arthritic diseases are described, including variations of disease manifestations under various situations and conditions. Furthermore, the need for a huge knowledge base would result in low efficiency of the inference system. We proposed a hierarchical model of the fuzzy inference system as a possible solution. With such a model, the diagnostic process is divided into two levels. The first level of the diagnosis reduces the scope of diagnosis to be processed by the second level. This will reduce the amount of input and mapping for the whole diagnostic process. Fuzzy relational theory is the core of this system and it is used in both levels to improve the accuracy.
  6. Ng KH, Ong SH, Bradley DA, Looi LM
    Appl Radiat Isot, 1997 Jan;48(1):105-9.
    PMID: 9022216
    Discriminant analysis of six trace element concentrations measured by instrumental neutron activation analysis (INAA) in 26 paired-samples of malignant and histologically normal human breast tissues shows the technique to be a potentially valuable clinical tool for making malignant-normal classification. Nonparametric discriminant analysis is performed for the data obtained. Linear and quadratic discriminant analyses are also carried out for comparison. For this data set a formal analysis shows that the elements which may be useful in distinguishing between malignant and normal tissues are Ca, Rb and Br, providing correct classification for 24 out of 26 normal samples and 22 out of 26 malignant samples.
  7. Wong KK, Ng KH, Nah SH, Yusof K, Rajeswari K
    Asia Oceania J Obstet Gynaecol, 1994 Mar;20(1):19-23.
    PMID: 8172522
    The general lack of specialist obstetricians in a developing country such as Malaysia prompted us to develop a computer expert system for the management of fetal distress in rural hospitals. It was based on accepted production rules and implemented on a microcomputer. The clinical prototype was evaluated by 8 specialist obstetricians and 21 non-specialist doctors involved in obstetric care. The initial impression was that this type of expert system may help in diagnosis, decision-making and teaching.
  8. Ng KH, Tan KL, Gan SK, Looi LM
    Malays J Pathol, 1992 Jun;14(1):29-33.
    PMID: 1469915
    The use of the colloidal-gold technique in electron microscopy immunocytochemistry has provided important information on the in situ localisation of intracellular antigens. We have developed a post-embedding technique for prolactin localisation on resin-embedded human pituitary tissue sections by the use of the protein-A gold conjugate. Human pituitary tissue obtained at autopsy was processed for electron microscopical study without post-osmication and then embedded in Epon. The indirect immunoperoxidase method was used for light microscopical targetting of lactotroph cells for subsequent electron microscopical antigen localisation. Ultra-thin sections were labelled with human anti-human prolactin followed by protein-A gold conjugate. Specific labelling was observed over secretory granules with a density of 15-30 particles per granule, as determined by the Quantimet 570 image analysis system. This technique provides a means of studying the pathophysiology of hormonal secretion at ultrastructural level and can be a useful tool in diagnostic and research investigations.
  9. Abdul Rahman A, Sinnathuray TA, Sivanesaratnam V, Ng KH
    Med J Malaysia, 1981 Jun;36(2):92-9.
    PMID: 6211595
    The early Malaysian experience of laparoscopic sterilisation with the Fallope tubal rings, as undertaken at the Obstetrical and Gynaecological Unit of the University Hospital, University of Malaya in Kuala Lumpur, Malaysia is reported in a study of 291 consecutive females that had had the procedure undertaken during the one year period, May 1975 to April 1976. Of the 291 cases, 247 women were sterilised in the "interval" period, 43 after "menstrual regulation" procedure and one after a spontaneous abortion. General anaesthesia was used in all except one case. The salient socio-demographic, contraceptive and reproductive characteristics of study cases are presented and discussed. The technical problems, the early complications and morbidity encountered in this study are presented and discussed in the light of other similar studies, and in relation to sterilisation by laparoscopic tubal electrocoagulation. The overall impression is that laparoscopic sterilisation with the Fallope tubal rings is preferred to that by tubal electrocoagulation, in view of the possible inadvertent serious electrical burns of other structures during the use of the latter procedure.
  10. Siar CH, Ng KH, Ngui CH, Chuah CH
    J Laryngol Otol, 1990 Mar;104(3):252-4.
    PMID: 2341785
    Clinical, radiological and histological characteristics of the peripheral ameloblastoma are briefly outlined. A case found occurring in the palate and presenting with atypical histological features is reported. The differential diagnosis of this lesion, its treatment and histogenesis are discussed.
  11. Karim MKA, Sabarudin A, Muhammad NA, Ng KH
    Radiol Phys Technol, 2019 Dec;12(4):374-381.
    PMID: 31468370 DOI: 10.1007/s12194-019-00532-8
    This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.
  12. Sim GS, Wong JH, Ng KH
    J Appl Clin Med Phys, 2013 Jul 08;14(4):4182.
    PMID: 23835383 DOI: 10.1120/jacmp.v14i4.4182
    Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek ScanMaker 9800XL scanner and the subsequent use in the dosimetric verification of a 3D conformal radiotherapy treatment. The film reproducibility and scanner uniformity of the Microtek ScanMaker 9800XL was studied. A three-field 3D conformal radiotherapy treatment was planned on an anthropomorphic phantom and EBT2 film measurements were carried out to verify the treatment. The interfilm reproducibility was found to be 0.25%. Over a period of three months, the films darkened by 1%. The scanner reproducibility was ± 2% and a nonuniformity was ±1.9% along the direction perpendicular to the scan direction. EBT2 measurements showed an underdose of 6.2% at high-dose region compared to TPS predicted dose. This may be due to the inability of the treatment planning system to predict the correct dose distribution in the presence of tissue inhomogeneities and the uncertainty of the scanner reproducibility and uniformity. The use of EBT2 film in conjunction with the axial CT image of the anthropomorphic phantom allows the evaluation of the anatomical location of dose discrepancies between the EBT2 measured dose distribution and TPS predicted dose distribution.
  13. Cheah SH, Ng KH, Johgalingam VT, Ragavan M
    J Endocrinol, 1995 Aug;146(2):331-7.
    PMID: 7561646
    The effects of exogenously introduced oestradiol-17 beta (E) and relaxin (RLX) on cervical extensibility and collagen organisation were tested in rats ovariectomised in late pregnancy. When the cervices were stretched in vitro by 1 mm increments, it was found that those from rats given E alone generated significantly higher tensions than those from control rats, while cervices from rats given both E and RLX had tensions similar to controls. Examination of cervical sections under the light microscope and ultra-thin sections under the electron microscope showed that the collagen fibres in the cervices from E-treated rats were highly organised, whereas those from animals given E+RLX and control animals were disorganised and dispersed. It was concluded that E decreased cervical extensibility, while RLX counteracted the effect of E to maintain a soft and easily extensible cervix.
  14. Siar CH, Nakano K, Ng KH, Tomida M, Nagatsuka H, Kawakami T
    Eur J Med Res, 2010 Apr 08;15(4):180-4.
    PMID: 20554499
    BACKGROUND: Squamous odontogenic tumor (SOT) is a rare benign odontogenic epithelial neoplasm. A slow-growing painless expansive swelling is the common presenting symptom. Histopathologically, SOT can be easily misdiagnosed as an acanthomatous ameloblastoma. Although Notch receptors and ligands have been shown to play a role in cell fate decisions in ameloblastomas, the role of these cell signaling molecules in SOT is unknown.

    CASE REPORT: This paper describes a case of SOT affecting the anterior mandible of a 10-year-old Indian female. The patient was treated by local surgical excision and there has been no follow-up clinical record of recurrence 5 years after primary treatment. Histo?pathological examination revealed a solid, locally-infiltrative neoplasm composed of bland-looking squamatoid islands scattered in a mature fibrous connective tissue stroma and the diagnosis was SOT. Immunohistochemical evaluation showed positive reactivity of varying intensity in the neoplastic epithelial cells for Notch1, Notch3, Notch4, and their ligands Jagged1 and Delta1. Expression patterns showed considerable overlap. No immunoreactivity was detected for Notch2 and Jagged2.

    CONCLUSIONS: Present findings suggest that Notch receptors and their ligands play differential roles in the cytodifferentiation of SOT.

  15. Siar CH, Nakano K, Chelvanayagam PI, Ng KH, Nagatsuka H, Kawakami T
    Eur J Med Res, 2010 Mar 30;15(3):135-8.
    PMID: 20452900
    The purpose of this report is to document a case of unsuspected ameloblastoma involving the right man dibular subpontic region in a 38-year-old Cambodian female patient. This lesion was purportedly preceded by multiple radiolucencies which were diagnosed as radicular cysts and treated a few times in the past years by enucleation followed by endodontic therapy of the affected teeth. Bridgework restoration of the partially edentulous area was performed. This case report demonstrates radiographic changes that occurred in the periods before and after the diagnosis of ameloblastoma. The case may represent an example of radicular cysts and ameloblastoma occurring as a collision phenomenon, or the ameloblastoma may have arisen as a result of neoplastic transformation of the lining epithelium in an inflammatory odontogenic epithelial cyst.
  16. Siar CH, Ng KH, Chia TY, Kulkarni MG
    Singapore Med J, 1988 Feb;29(1):83-5.
    PMID: 3406779
    The aetiology, clinical and histological features of neurilemmomas of the oral and paraoral regions are briefly outlined. Two cases of atypical neurilemmomas of the tongue are described with an intent to document the partial encapsulation and multilobular distribution of the neurogenic tissue noted in these two lesions.
  17. Velayutham P, Govindasamy GK, Raman R, Prepageran N, Ng KH
    Indian J Otolaryngol Head Neck Surg, 2014 Jan;66(Suppl 1):169-72.
    PMID: 24533378 DOI: 10.1007/s12070-011-0406-4
    The objective of this study is to assess high frequency hearing (above 8 kHz) loss among prolonged mobile phone users is a tertiary Referral Center. Prospective single blinded study. This is the first study that used high-frequency audiometry. The wide usage of mobile phone is so profound that we were unable to find enough non-users as a control group. Therefore we compared the non-dominant ear to the dominant ear using audiometric measurements. The study was a blinded study wherein the audiologist did not know which was the dominant ear. A total of 100 subjects were studied. Of the subjects studied 53% were males and 47% females. Mean age was 27. The left ear was dominant in 63%, 22% were dominant in the right ear and 15% did not have a preference. This study showed that there is significant loss in the dominant ear compared to the non-dominant ear (P 
  18. Ng KH, Siar CH, Ramanathan K, Murugasu P, Chelvanayagam PI
    PMID: 3835704
    The prevalence rate of 749 cases of oral squamous cell carcinomas (SCC) recorded between 1978-1984 was studied. Results showed that the Indians formed the dominant group (63.8%) followed by the Malays (19.6%) and Chinese (16.6%). The peak incidences were generally located between the sixth and eighth decades. Only in the Chinese group a male preponderance was noted. In the Indians, the buccal mucosa was the most prevalent site; in the Malays and Chinese males, the gingiva and alveolus; and the Chinese female, the tongue. In all three groups, the well-differentiated SCC was the commonest type and the poorly differentiated least common.
  19. Yeong CH, Blackshaw PE, Ng KH, Abdullah BJ, Blaauw M, Dansereau RJ, et al.
    Appl Radiat Isot, 2011 Sep;69(9):1181-4.
    PMID: 21550260 DOI: 10.1016/j.apradiso.2011.04.017
    Neutron activation of Sm-152 offers a method of radiolabeling for the in vivo study of oral dose formulations by gamma scintigraphy. Reproducibility measurements are needed to ensure the robustness of clinical studies. 204 enteric-coated guaifenesin core tablets (10mg of Sm(2)O(3)) were irradiated by thermal neutrons to achieve 1 MBq at 48 h. Administered activities were 0.86±0.03 MBq. Good reproducibility (CV=3.5%) was observed over 24 weeks ensuring that volunteer doses were within the dose reference level of 0.8 mSv.
  20. Azlan CA, Mohd Nasir NF, Saifizul AA, Faizul MS, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2007 Dec;30(4):288-91.
    PMID: 18274069
    Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.