METHODS: This was a cross-sectional study involving 42 male competitive basketball players. Subjects were divided into the injured and uninjured groups based on self-reported questionnaires. Ankle range of motion (ROM) was measured using a goniometer, ankle isokinetic strength testing performed using Biodex System 4 PRO, and single-leg stability tests performed using Biodex Balance System SD.
RESULTS: Between the injured and uninjured ankles, there was a decrease in plantarflexion ROM (44.89±6.85 vs. 50.75±9.31, P<0.05) and an increase in eversion ROM (14.50±5.63 vs. 11.74±4.53, P<0.05). There was a reduction in inversion and plantarflexion strength at 30°/s peak torque and 120 °/s peak torque (P<0.05). However, no significant difference observed in the postural stability indexes between the two groups.
CONCLUSIONS: This study proves that there are residual ROM and strength deficits after an ankle sprain, however, these deficits do not affect their balance ability.
METHODS: Male participants (age 22.0±3.4) performed ramped isometric knee extensions at knee joint angles of 90°, 70°, 50° and 30° of flexion. Strain patterns of the anterior and posterior regions of the patellar tendon were determined using real-time B-mode ultrasonography at each knee joint angle. Regional strain measures were compared using an automated pixel tracking method.
RESULTS: Strain was seen to be greatest for both the anterior and posterior regions with the knee at 90° (7.76±0.89% and 5.06±0.76%). Anterior strain was seen to be significantly greater (p<0.05) than posterior strain for all knee angles apart from 30°, 90°=(7.76vs. 5.06%), 70°=(4.77vs. 3.75%), and 50°=(3.74vs. 2.90%). The relative strain (ratio of anterior to posterior), was greatest with the knee joint angle at 90°, and decreased as the knee joint angle reduced.
CONCLUSIONS: The results from this study indicate that not only are there greater absolute tendon strains with the knee in greater flexion, but that the knee joint angle affects the regional strain differentially, resulting in greater shear between the tendon layers with force application when the knee is in greater degrees of flexion. These results have important implications for rehabilitation and training.
METHODS: Seventy clavicle fractures were non-surgically treated in the Orthopedics Department at the Tuanku Ja'afar General Hospital, a tertiary care hospital in Seremban, Malaysia, an average of six months after injury. The clavicle fractures were treated conservatively with an arm sling and a figure-eight splint for three weeks. No attempt was made to reduce displaced fractures, and the patients were allowed immediate free-shoulder mobilization, as tolerated. They were prospectively evaluated clinically and radiographically. Shoulder function was evaluated using the Constant scoring technique.
RESULTS: There were statistically significant functional outcome impairments in non-surgically treated clavicle fractures that correlated with the fracture type (comminution), the fracture displacement (21 mm or more), shortening (15 mm or more) and the fracture union (malunion).
CONCLUSION: This article reveals the need for surgical intervention to treat clavicle fractures and improve shoulder functional outcomes.
RESULTS: Participants in the RPG and CG reported a statistically significant reduction in knee pain and stiffness (p ≤ 0.05) within the group. The reduction in the scores of knee pain was higher in participants in the RPG than that in participants in the CG (p=0.001). Additionally, participants in the RPG reported greater satisfaction (p=0.001) and higher self-reported exercise adherence (p=0.010) and coordinator-reported exercise adherence (p=0.046) than the participants in the CG.
CONCLUSION: Short-term effects of the LLRP appear to reduce knee pain and stiffness only, but not physical function and BMI.
Materials and Methods: This study was conducted between Oct 2010 to Dec 2015. One-hundred-fifty fracture shafts of the humerus were treated with the anteromedial plating through the anterolateral approach.
Results: One-hundred-fifty patients with a fracture shaft of the humerus were treated with anteromedial plating. Twenty were female (mean ±SD,28 years±4.5) and 130 were male (mean ± SD, 38 years±5.6). One hundred and forty-eight out of 150 (98.6%) patients achieved union at 12 months. Two of three patients developed a superficial infection, both of which were treated successfully by antibiotics and one developed a deep infection, which was treated by wound debridement, prolonged antibiotics with the removal of the plate and subsequently by delayed plating and bone grafting.
Conclusion: In the present study, we applied plate on the anteromedial flat surface of humerus using the anterolateral approach. It is an easier and quicker fixation as compared to anterolateral plating because later involved much more dissection than a medial application of the plate and this application of plate on a medial flat surface, does not required Radial nerve exposure and palsy post-operatively. The significant improvement in elbow flexion without brachialis dissection is also a potential benefit of this approach. Based on our results, we recommend the application of an anteromedial plate for treatment of midshaft fractures humerus.
METHODS AND DESIGN: A randomised, single blind controlled trial will be conducted. Twenty-eight patients aged 18 years and above with a recent grade-2 hamstring injury will be invited to take part. Participants will be randomised to receive either autologous PRP injection with rehabilitation programme, or rehabilitation programme only. Participants will be followed up at day three of study and then weekly for 16 weeks. At each follow up visit, participants will be assessed on readiness to return-to-play using a set of criteria. The primary end-point is when participants have fulfilled the return-to-play criteria or end of 16 weeks.The main outcome measure of this study is the duration to return-to-play after injury.
CONCLUSION: This study protocol proposes a rigorous and potential significant evaluation of PRP use for grade-2 hamstring injury. If proven effective such findings could be of great benefit for patients with similar injuries.
TRIAL REGISTRATION: Current Controlled Trials ISCRTN66528592.
METHODS: Forty-three participants (23 asymptomatic and 20 with CNP) underwent neck proprioception testing, returning to a NHP and THP in both sitting and standing positions (six trials for each test). A laser pointer was secured on the participant's forehead and inertial measurement unit (IMU) sensors were placed beneath the laser pointer and at the level of the spinous process of the seventh cervical vertebra. Both the absolute and the constant JPE were assessed.
FINDINGS: For the asymptomatic participants, good reliability (ICC: 0.79) was found only for right rotation of the THP task in sitting. In standing, good reliability (ICC: 0.77) was only found in flexion for the THP task. In standing, good reliability (ICC: 0.77) was only found for right rotation of the THP for the absolute JPE and left rotation (ICC: 0.85) for the constant error of the NHP task. In those with CNP, when tested in sitting, good reliability was found for flexion (ICC: 0.8) for the absolute JPE and good reliability (ICC range: 0.8-0.84) was found for flexion, extension, and right rotation for the constant JPE. In standing, good reliability (ICC range: 0.81-0.88) was found for flexion, and rotation for the absolute JPE. The constant JPE showed good reliability (ICC: 0.85) for right rotation and excellent reliability (ICC: 0.93) for flexion. Validity was weak to strong (r range: 0.26-0.83) and moderate to very strong (r range: 0.47-0.93) for absolute and constant error respectively, when tested in sitting. In standing, the validity was weak to very strong (0.38-0.96) for the absolute JPE and moderate to very strong (r range: 0.54-0.92) for the constant JPE.
CONCLUSION: The reliability of the measure of JPE when tested in sitting and standing in both groups showed good reliability, but not for all movements. The results of the current study also showed that the laser pointer correlated well with the Noraxon IMUs, but not for all movements. The results of the current study support the use of the JPE using a laser pointer in clinical and research settings.