Displaying publications 81 - 100 of 312 in total

Abstract:
Sort:
  1. Butt AM, Mohd Amin MC, Katas H
    Int J Nanomedicine, 2015;10:1321-34.
    PMID: 25709451 DOI: 10.2147/IJN.S78438
    BACKGROUND: Doxorubicin (DOX), an anthracycline anticancer antibiotic, is used for treating various types of cancers. However, its use is associated with toxicity to normal cells and development of resistance due to overexpression of drug efflux pumps. Poloxamer 407 (P407) and vitamin E TPGS (D-α-tocopheryl polyethylene glycol succinate, TPGS) are widely used polymers as drug delivery carriers and excipients for enhancing the drug retention times and stability. TPGS reduces multidrug resistance, induces apoptosis, and shows selective anticancer activity against tumor cells. Keeping in view the problems, we designed a mixed micelle system encapsulating DOX comprising TPGS for its selective anticancer activity and P407 conjugated with folic acid (FA) for folate-mediated receptor targeting to cancer cells.

    METHODS: FA-functionalized P407 was prepared by carbodiimide crosslinker chemistry. P407-TPGS/FA-P407-TPGS-mixed micelles were prepared by thin-film hydration method. Cytotoxicity of blank micelles, DOX, and DOX-loaded micelles was determined by alamarBlue(®) assay.

    RESULTS: The size of micelles was less than 200 nm with encapsulation efficiency of 85% and 73% for P407-TPGS and FA-P407-TPGS micelles, respectively. Intracellular trafficking study using nile red-loaded micelles indicated improved drug uptake and perinuclear drug localization. The micelles show minimal toxicity to normal human cell line WRL-68, enhanced cellular uptake of DOX, reduced drug efflux, increased DOX-DNA binding in SKOV3 and DOX-resistant SKOV3 human ovarian carcinoma cell lines, and enhanced in vitro cytotoxicity as compared to free DOX.

    CONCLUSION: FA-P407-TPGS-DOX micelles show potential as a targeted nano-drug delivery system for DOX due to their multiple synergistic factors of selective anticancer activity, inhibition of multidrug resistance, and folate-mediated selective uptake.

    Matched MeSH terms: Polyethylene Glycols/pharmacokinetics; Polyethylene Glycols/chemistry
  2. Tiede A, Abdul-Karim F, Carcao M, Persson P, Clausen WHO, Kearney S, et al.
    Haemophilia, 2017 Jul;23(4):547-555.
    PMID: 28233381 DOI: 10.1111/hae.13191
    INTRODUCTION: Nonacog beta pegol (N9-GP) is a glycoPEGylated recombinant factor IX (FIX) with an extended half-life developed for routine prophylaxis and the prevention and treatment of bleeding episodes in patients with haemophilia B.

    AIM: The aim of this study was to evaluate the pharmacokinetics (PK) of N9-GP.

    METHODS: Data from 41 previously treated haemophilia B patients, enrolled globally (16 adolescents/adults and 25 children; FIX activity ≤0.02 IU mL-1) with no history of FIX inhibitors, were included. N9-GP was administered once-weekly as 10 IU kg-1or 40 IU kg-1in adolescents/adults and 40 IU kg-1in children. Blood was sampled up to 168 h (1 week) post dose. Standard PK was estimated on the basis of plasma FIX activity vs. time (PK profiles) using non-compartmental methods. Furthermore, a population PK analysis and FIX activity predictions were performed.

    RESULTS: Incremental recoveries were 0.02 (IU mL-1)/(IU kg-1) in both adolescents/adults and children. The extended half-life resulted in mean trough levels of 0.27 IU mL-1for adolescents/adults and 0.17 IU mL-1for children at steady-state after weekly dosing at 40 IU kg-1. The population PK analysis confirmed a mono-exponential decay in FIX activity and allowed for predictions of FIX activity for adolescents/adults above 0.15 IU mL-1at all times and 6.4 days week-1in children.

    CONCLUSION: N9-GP has the potential to shift previously treated haemophilia B patients from a severe/moderate disease state into a mild- or non-haemophilic range for most of the dosing interval, which is expected to reduce the number of bleeding episodes.

    Matched MeSH terms: Polyethylene Glycols/pharmacokinetics*; Polyethylene Glycols/therapeutic use
  3. Adam A, Marzuki A, Abdul Rahman H, Abdul Aziz M
    Vet Hum Toxicol, 1997 Jun;39(3):147-51.
    PMID: 9167243
    The toxicities of ROUNDUP and its component chemicals, glyphosate (N-phosphonomethylglycine) and polyoxyethyleneamine (POEA), were determined at 0, 1, 3, 6 and 24 h following administration to rats. The intratracheal administration of glyphosate (0.2 g/kg), POEA (0.1 g/kg), a mixture of glyphosate (0.2 g/kg) + POEA (0.1 g/kg), or ROUNDUP (containing 0.2 g/kg glyphosate and 0.1 g/kg POEA) elicited immediate respiratory effects which were more severe and which lasted longer in the groups receiving the POEA-containing preparations than in the glyphosate alone group. By 1 h, all test preparations had caused deaths, but more occurred from the POEA-containing preparations than from glyphosate. The po administration of POEA (1 g/kg), the mixture of glyphosate (2 g/kg) +POEA (1 g/kg), or ROUNDUP (containing 2 g/kg glyphosate and 1 g/kg POEA) produced diarrhea and blood-stained weeping from noses. Death was only seen from POEA at 24 h. Glyphosate (2 g/kg po) produced transient diarrhea without nose bleeds; POEA caused diarrhea at 1 h; and the mixture of POEA + glyphosate produced diarrhea later that increased in severity with time. Bloody nose secretions were seen only with the preparations that contained POEA. No deaths, respiratory effects or bloody nose secretions occurred in controls given saline. Both POEA and glyphosate caused lung hemorrhages and lung epithelial cell damage with po or intratracheal exposures. These results indicate POEA and preparations that contained POEA were more toxic than glyphosate.
    Matched MeSH terms: Polyethylene Glycols/administration & dosage; Polyethylene Glycols/toxicity*
  4. Chan WK, Azmi N, Mahadeva S, Goh KL
    World J Gastroenterol, 2014 Oct 21;20(39):14488-94.
    PMID: 25339836 DOI: 10.3748/wjg.v20.i39.14488
    To compare same-day whole-dose vs split-dose of 2-litre polyethylene glycol electrolyte lavage solution (PEG-ELS) plus bisacodyl for colon cleansing for morning colonoscopy.
    Matched MeSH terms: Polyethylene Glycols/administration & dosage*; Polyethylene Glycols/adverse effects
  5. Carcao M, Zak M, Abdul Karim F, Hanabusa H, Kearney S, Lu MY, et al.
    J Thromb Haemost, 2016 Aug;14(8):1521-9.
    PMID: 27174727 DOI: 10.1111/jth.13360
    Essentials Nonacog beta pegol is a recombinant glycoPEGylated factor IX with an extended half-life. This phase 3 trial investigated its safety/efficacy in previously treated hemophilia B boys ≤ 12 years. A 40 IU kg(-1) dose provided effective once-weekly prophylaxis and hemostasis when used to treat bleeds. Nonacog beta pegol was well tolerated in previously treated boys ≤ 12 years with hemophilia B.

    SUMMARY: Background Nonacog beta pegol is a recombinant glycoPEGylated factor IX with an extended half-life, developed to improve care for patients with hemophilia B. Objectives To investigate the safety, efficacy and pharmacokinetics of nonacog beta pegol for the prophylaxis and treatment of bleeds in previously treated children with hemophilia B. Patients/Methods This phase 3 trial, paradigm(™) 5, enrolled and treated 25 children (aged ≤ 12 years) with hemophilia B (FIX ≤ 2%). Patients were stratified by age (0-6 years and 7-12 years), and received once-weekly prophylaxis with 40 IU kg(-1) nonacog beta pegol for 50 exposure days. Results No patient developed inhibitors, and no safety concerns were identified. Forty-two bleeds in 15 patients were reported to have been treated; the overall success rate was 92.9%, and most bleeds (85.7%) resolved after one dose. The median annualized bleeding rates (ABRs; bleeds per patient per year) were 1.0 in the total population, 0.0 in the 0-6-year group, and 2.0 in the 7-12-year group; the estimated mean ABRs were 1.44 in the total population, 0.87 in the 0-6-year group, and 1.88 in the 7-12-year group. For 22 patients who had previously been receiving prophylaxis, the estimated mean ABR was 1.38 versus a historical ABR of 2.51. Estimated mean steady-state FIX trough levels were 0.153 IU mL(-1) (0-6 years) and 0.190 IU mL(-1) (7-12 years). Conclusion Nonacog beta pegol was well tolerated in previously treated children with hemophilia B; a 40 IU kg(-1) dose provided effective once-weekly prophylaxis and hemostasis when bleeds were treated.

    Matched MeSH terms: Polyethylene Glycols/pharmacokinetics*; Polyethylene Glycols/therapeutic use
  6. Xuan L, Hui D, Cheng W, Wong AHH, Han G, Tan WK, et al.
    Materials (Basel), 2017 Jul 12;10(7).
    PMID: 28773150 DOI: 10.3390/ma10070789
    The effects of alkaline copper quaternary (ACQ) and zinc borate (ZB) on the resistance of corn stalk fiber (CSF)-reinforced high-density polyethylene (HDPE) composites to biodegradation were examined. Both biocides could inhibit termites, mold fungi, and wood-decay fungi, even at high CSF formulations (i.e., 60%). Additionally, ACQ enhanced the resistance of the composite materials to certain biotic stresses better than ZB. The CSF/HDPE composites treated with ACQ at the 3.0% level exhibited a superior performance against termites, white rot fungi, and brown rot fungi. ACQ treatment at the 1% level was optimal for inhibiting soft rot fungi. Furthermore, mold growth was not observed on ACQ-treated CSF/HDPE samples. The untreated CSF/HDPE composites were more susceptible to mold infections and decay than the untreated poplar/HDPE composites, likely because of an incomplete removal of the pith. The chemical features of the corn stalk may also have influenced these differences, but this possibility will need to be explored in future investigations. Furthermore, the CSF component of CSF/HDPE composites is highly susceptible to fungal attacks, with the soft rot fungus inducing the largest mass losses, followed by the white rot fungus, and then the brown rot fungus.
    Matched MeSH terms: Polyethylene
  7. Safri LS, Md Noh MSF, Hariz Ramli AR, Md Pauzi SH, Md Idris MA, Harunarashid H
    J Vasc Surg Cases Innov Tech, 2018 Jun;4(2):160-162.
    PMID: 29942910 DOI: 10.1016/j.jvscit.2018.03.004
    Aortic malignant neoplasms are rare; these may be primary or secondary (metastatic). Increasing use of cross-sectional imaging has allowed better detection and diagnosis of these conditions. We encountered a young woman presenting with acute abdomen who was found on cross-sectional imaging to have a malignant tumor involving the aortic bifurcation. An en bloc excision of the tumor was performed, with distal aorta reconstruction using an aortoiliac Dacron graft; this was complicated with infection and graft occlusion, necessitating total removal and extra-anatomic bypass. A pathologic diagnosis of metastatic adenocarcinoma involving the aortic bifurcation, with an unknown primary, was made.
    Matched MeSH terms: Polyethylene Terephthalates
  8. Norshazila, S., Othman, R., Jaswir, I., Yumi Zuhanis, H.H.
    MyJurnal
    In nature, environmental factors highly influence the carotenoid composition in pumpkin plants and these factors were difficult to control; thus, carotenoid content is varied quantitatively and qualitatively. However, certain parameters can be controlled and this can be conducted in the laboratory through biogenesis manipulation. This approach uses environmental stress as a tool to alter the carotenoid pathway in the plants. The main objective of this study was to observe the inhibiting and enhancing effect of abiotic stress on individual carotenoid accumulation in pumpkin plants under light and dark conditions. The abiotic stresses used were plant elicitors which consisted of Ultra Violet light exposure, Polyethylene Glycol 4000, Salicylic Acid, and half strength nutrients using Murashige and Skoog Salt. After two weeks of treatments, the pumpkin leaves and stems were harvested, freeze dried and extracted to determine the carotenoids compound using High-Performance Liquid Chromatography (HPLC). Results showed that there was a significant difference (p
    Matched MeSH terms: Polyethylene Glycols
  9. Tan, Hui San, Abdoreza Soleimani Farjam, Goh, Yong Meng, Idrus Zulkifli, Evi Croes, Sarathi Karmakar Partha, et al.
    MyJurnal
    This research was done to evaluate the effect of a commercial exogenous emulsifier
    (polyethylene glycol ricinoleate (PEGR)) with high hydrophilic-to-lipophilic balance (HLB)
    supplementation to broiler chicken diets on growth performance, digestibility of fat and
    apparent metabolisable energy (AME) content in week 1, 3 and 5. A total of 360 one-day-old
    male Cobb broiler chicks were assigned in groups of 30 to 12 battery cages. The chicks were
    randomly assigned to two dietary treatments, with 6 replicate cages per treatment. The diets
    were either standard broiler starter and finisher, with rice bran oil (RBO) as supplemented fat
    source or similar diets + 0.05% emulsifier (RBOV). Feed intakes of RBOV groups significantly
    increased compared to those of RBO groups from week 2 till 4 while body weights of RBOV
    diets significantly increased in week 4 and 5. Both RBOV and RBO groups had similar FCR
    except for week 5. Addition of this strongly hydrophilic emulsifier showed no significant
    difference in fat digestibility of both RC and RV groups but higher AME was noted for the
    treatment than for the control groups at week 5. Therefore, supplementing the exogenous
    emulsifier into a broiler diet enriched with rice bran oil improved body weight and AME
    content at week 5 with minimal effect on fat digestibility.
    Matched MeSH terms: Polyethylene Glycols
  10. Chew KW, Chia SR, Krishnamoorthy R, Tao Y, Chu DT, Show PL
    Bioresour Technol, 2019 Sep;288:121519.
    PMID: 31128541 DOI: 10.1016/j.biortech.2019.121519
    Liquid biphasic flotation (LBF), an integrated process of liquid biphasic system (LBS) and adsorptive bubbles flotation, was used for the purification of C-phycocyanin from S. platensis microalgae. Various experimental parameters such as type of phase forming polymer and salt, concentration of phase forming components, system pH, volume ratio, air flotation time and crude extract concentration were evaluated to maximise the C-phycocyanin recovery yield and purity. The optimal conditions for the LBF system achieving C-phycocyanin purification fold of 3.49 compared to 2.43 from the initial LBF conditions was in polyethylene glycol (PEG) 4000 and potassium phosphate combination, with 250 g/L of polymer and salt concentration each, volume ratio of 1:0.85, system pH of 7.0, air flotation duration of 7 min and phycocyanin crude extract concentration of 0.625 %w/w. The LBF has effectively enhanced the purification of C-phycocyanin in a cost effective and simple processing.
    Matched MeSH terms: Polyethylene Glycols
  11. Rahmadini Syafri, Ishak Ahmad, Ibrahim Abdullah
    Sains Malaysiana, 2011;40:1123-1127.
    Surface modification of rice husk (RH) with alkali pre-treatment (NaOH solution 5% w/v) was carried out at the initial state to investigate the effect of surface treatment of fibre on the surface interaction between fibre and rubber. Further modification of RH surfaces after alkali treatment was using Liquid Epoxidized Natural Rubber (LENR) coating at three concentrations, 5%, 10%, and 20% wt LENR solution in toluene. Interfacial morphology and chemical reactions between RH fibre and rubber were analyzed by FTIR and Scanning Electron Microscope (SEM). It was found that 10% wt LENR solution gave the optimum interaction between fibre and rubber. Matrix and composite blends derived from 60% natural rubber (NR), 40% high density polyethylene (HDPE) reinforced with RH fibre were prepared using an internal mixer (Brabender Plasticoder). Result showed that pre-treatment of RH treated with 5% NaOH followed by treatment with 10% LENR solution given the maximum interaction between fibre and matrix that gave rise to better mechanical properties of the composites.
    Matched MeSH terms: Polyethylene
  12. Nur Sha'dah Z, Iskandar S, Azhar A, Suhaimi M, Nur Lina R, Halimah M
    Sains Malaysiana, 2014;43:953-958.
    The effects of the X-ray irradiation and chemical etching on the physical and optical properties of cR-39 plastic detectors were investigated for different doses of X-ray. cR-39 detectors were etched in the solution of the 3 M of NaOH after irradiation for revelations of the track. The tracks formed on cR-39 either by irradiated X-ray or due to the effect of environment. The changes in the thickness after exposed have significant decrease in 60 kVp and started to increase in the range of 70 kVp up to 100 kVp due to the formation of oxidation layer on surface by free radicals. The optical band gaps before etching and after etching were determined by using Ultraviolet-visible (uv-Vis) spectroscopy. The optical band gap is attributed to the indirect transition due to its amorphous nature which is significantly decline trend energy in increase of the energy fluence of radiation. The Urbach's energy, is defined as the width of the tail localized states in the forbidden band gap which change increment trend as increase in dose delivered due to the distortion structure of the cR-39 in terms of the electron charges in valences electron hence attributes to the induced modification of angle bond between the neighboring atoms.
    Matched MeSH terms: Polyethylene Glycols
  13. Lee WC, Wee L
    Malays Orthop J, 2019 Mar;13(1):42-44.
    PMID: 31001383 DOI: 10.5704/MOJ.1903.008
    We present a unique case of tibial post fracture of a posterior-stabilised total knee arthroplasty (PS-TKA) using highly crosslinked polyethylene (HXLPE) in the unafflicted limb of a patient who had poliomyelitis. The tibial post is an upright structure perpendicular to the PE insert articular surface which articulates with the cam of the femoral component to prevent excessive posterior translation of the tibia. We explore the choice of PS polyethylene (PE) inserts in patients with neuromuscular disorders (NMD). A 74-year old gentleman presented with recurrent knee pain seven years after the index PS-TKA with HXLPE. The TKA was performed on the unafflicted left limb (contralateral to the weak side affected by poliomyelitis). The posterior drawer test was positive. During the single-stage revision surgery, the HXLPE tibial post was noted to be broken. The liner was replaced with a thicker non-HXLPE. The patient achieved an excellent outcome at one-year post-surgery. This is the first report of HXLPE tibial post fracture in the unaffected knee of a patient with NMD affecting the lower limb. The HXLPE's reduced resistance to fatigue crack propagation might not be suitable in PS-TKA where there might be focal stress points on the tibial post, which was amplified in this case as it was the limb that the patient most depended on. When managing end-stage osteoarthritis with TKA in the unafflicted knee of a patient with NMD causing lower limb weakness, the selection of polyethylene material in PS-TKA may need more consideration than previously thought.
    Matched MeSH terms: Polyethylene
  14. Roslinah M, Wan Hitam WH, Md Salleh MS, Abdul Hamid SS, Shatriah I
    Cureus, 2019 Jan 25;11(1):e3954.
    PMID: 30956907 DOI: 10.7759/cureus.3954
    We aimed to compare clinical and pathological reactions towards locally synthesized bovine bone derived from hydroxyapatite (bone docosahexaenoic acid (dHA)) and commercially available porous polyethylene (Medpor®, Porex Surgical Incorporation, Georgia, USA) orbital implants in animal models. An experimental study was performed on 14 New Zealand white rabbits. Group A (n=7) was implanted with bovine bone dHA and group B (n=7) was implanted with Medpor®. Clinical examinations were performed on Days 1, 7, 14, 28, and 42 post-implantation. The implanted eyes were enucleated on Day 42 and were sent for pathological evaluation. Serial clinical examinations included urine color and odor; feeding and physical activity demonstrated normal wellbeing in all the subjects. Localized minimal infection was observed in both groups during the first two weeks following implantation, and the subjects responded well to topical moxifloxacin. Both groups exhibited evidence of wound breakdown. No signs of implant migration or extrusion were observed in either group. The histopathological examination revealed no statistically significant difference in inflammatory cell reactions and fibrovascular tissue maturation between both types of implants. However, all (100%) of the bovine bone dHA implants displayed complete fibrovascular ingrowth compared to Medpor® implants (57.1%) at six weeks post-implantation (p=0.001). In conclusion, bovine bone dHA and Medpor® orbital implants were well-tolerated clinically and displayed similar inflammatory reactions and fibrovascular tissue maturation. Locally synthesized bovine bone dHA orbital implants displayed significantly greater complete fibrovascular ingrowth in comparison with Medpor® implants.
    Matched MeSH terms: Polyethylene
  15. Reza Hashemi Farzad, Azman Hassan, M. Jawaid, M.A.M. Piah
    Sains Malaysiana, 2013;42:801-810.
    Polymeric materials such as polypropylene (PP), polyethylene (PE) and ethylene propylene diene monomer (EPDM) are widely used as insulators for cable applications. We investigated the effect of alumina trihydrate (ATH) loading on the mechanical properties of PP/EPDM blend. Preliminary study showed that PP/EPDM (60:40) was the optimum composition. ATH filled PP/EPDM composites was prepared by using twin screw extruder. In this study, the tensile properties and hardness of the composites were evaluated. The tensile modulus and hardness increased while elongation at break and tensile strength decreased with increasing ATH content. Scanning electron microscope was used to study the morphology of ATH in PP/EPDM blend.
    Matched MeSH terms: Polyethylene
  16. Abdullahi A, Choudhury I, Azuddin M, Nahar N
    Sains Malaysiana, 2017;46:477-483.
    A suitable and cost-effective microfabrication technique for processing aluminum micropart is required, as the choice
    of aluminum microparts for aerospace, electronics and automobile components is preferred over other metals due to its
    excellent properties. Meanwhile, powder injection molding (PIM) is identified as an economical manufacturing technique
    for processing ceramic and micro-metal powders into microparts and or components. Therefore, this study investigates
    formulation and processing of aluminum PIM feedstock using a custom-made machine. The investigation is focused on
    the effect of mixing process parameters (powder loading, rotor speed and mixing temperature) and the suitability of
    the backbone polymer. The formulated PIM feedstock constituents are paraffin wax (PW), stearic acid (SA), high-density
    polyethylene (HDPE)/ medium-density polyethylene (MDPE) alternatively and aluminum micro-metal powder. Taguchi
    method is used for the design of experiments (DOEs) and analysis. In addition, response surface methodology (RSM) is
    employed to develop empirical viscosity models. The optimum powder-binder mixing ratio of 58:42 vol. % with rotor
    speed of 43 rpm were determined for preparing aluminum PIM feedstock using mini-lab mixer developed. The empirical
    model developed for aluminum PIM feedstock viscosity shows a good fit with R2
    values of 0.84 using HDPE and 0.96 for
    MDPE binder system. This investigation demonstrates preparation and suitability of aluminum PIM feedstock using waxbased
    binder system.
    Matched MeSH terms: Polyethylene
  17. Sri Yulis M. Amin, Norhamidi Muhamad, Khairur Rijal Jamaludin, Fayyaz A, Heng SY
    Sains Malaysiana, 2014;43:123-128.
    Feedstock preparation, as well as its characterization, is crucial in the production of highly sintered parts with minimal defect. The hard metal powder - particularly, cemented carbide (wc-co) used in this study was investigated both physically and thermally to determine its properties before the mixing and injection molding stage. Several analyses were conducted, such as scanning electron microscopy, energy dispersive X-ray diffraction, pycnometer density, critical powder volume percentage (cPvP), as well as thermal tests, such as thermogravimetric analysis and differential scanning calorimetry. On the basis of the CPVP value, the feedstock, consisting of wc-co powder, was mixed with 60% palm stearin and 40% polyethylene at an optimal powder loading, within 2 to 5% lower than the CPVP value. The CPVP spotted value was 65%. The feedstock optimal value at 61% showed good rheological properties (pseudoplastic behavior) with an n value lower than 1, considerably low activation energy and high moldability index. These preliminary properties of the feedstock serve as a benchmark in designing the schedule for the next whole steps (i.e. injection, debinding and sintering processes).
    Matched MeSH terms: Polyethylene
  18. Sabet M, Soleimani H
    Heliyon, 2019 Jul;5(7):e02053.
    PMID: 31334378 DOI: 10.1016/j.heliyon.2019.e02053
    The spread of graphene in low-density polyethylene (LDPE) improves LDPE/graphene nanocompounds' thermal/mechanical/electrical characteristics. The images of scanning electron microscopy (SEM) verify full graphene exfoliation at 1000 °C. Inclusion graphene develops crystallinity; increases the local order of lattice and thermal stability of LDPE/graphene nanocompounds. The consistent distributions and further inclusion of graphene caused the great heat breakdown strength, increasing heat breakdown activation energy and a superior melting point (Tm) for LDPE nanocompounds. Percolation occurs with the graphene incorporation of 0.5 wt%. The complex viscosity test showed Newtonian behavior for LDPE at a very low frequency. But, graphene inclusion to LDPE changed the viscosity performance from liquid-like to solid-like which caused a decrease in the melt flow rate (MFR) values for all LDPE/graphene nanocompounds.
    Matched MeSH terms: Polyethylene
  19. Akbari A, Mohammadian E, Alavi Fazel SA, Shanbedi M, Bahreini M, Heidari M, et al.
    ACS Omega, 2019 Nov 19;4(21):19183-19192.
    PMID: 31763542 DOI: 10.1021/acsomega.9b02474
    An increase of nucleate pool boiling with the use of different fluid properties has received much attention. In particular, the presence of nanostructures in fluids to enhance boiling was given special consideration. This study compares the effects of graphene nanoplatelet (GNP), functionalized GNP with polyethylene glycol (PEG), and multiwalled carbon nanotube (CNT) nanofluids on the pool boiling heat transfer coefficient and the critical heat flux (CHF). Our findings showed that at the same concentration, CHF for functionalized GNP with PEG (GNP-PEG)/deionized water (DW) nanofluids was higher in comparison with GNP- and CNT-based nanofluids. The CHF of the GNP/DW nanofluids was also higher than that of CNT/DW nanofluids. The CHF of GNP-PEG was 72% greater than that of DW at the concentration of 0.1 wt %. There is good agreement between measured critical heat fluxes and the Kandlikar correlation. In addition, the current results proved that the GNP-PEG/DW nanofluids are highly stable over 3 months at a concentration of 0.1 wt %.
    Matched MeSH terms: Polyethylene Glycols
  20. Choo YSL, Giamberini M, Antonio J, Waddell PG, Benniston AC
    Org Biomol Chem, 2020 Nov 04;18(42):8735-8745.
    PMID: 33094783 DOI: 10.1039/d0ob01533d
    The reaction of diethyl 2,5-bis(tert-butyl)phenoxy-3,6-dihydroxyterephthalate (1) with tetraethylene glycol di(p-toluenesulfonate) under high-dilution conditions afforded several isolated products. Two products were identified as macrocycles with one being the 1 + 1 crown ether derivative 3 (10% yield), and the second being the 2 + 2 crown ether compound D3 (19% yield). The X-ray structure for 3 was determined with the asymmetric unit observed to comprise half of the molecule. The small crown ether ring of 3 interacts with K+ or H+ ions in MeOH, but binding is weak and the macrocyclic cavity is too small to fully encapsulate the K+ ion. Transesterification of compounds 1, its methylated version 2 and 3 with diols such as ethylene glycol or 1,4-butandiol produced monomers (M1-M3) which were reacted with terephthaloyl chloride. Short oligomers were produced (PolyM1-PolyM3) rather than extensive polymeric materials and all displayed solid state fluorescence. The absorption and fluorescence properties of M1-M2 and their polymers can be related to subtle structural changes. The Stokes shift for M2 of 15 627 cm-1 in DCM is one of the largest observed for a simple organic chromophore in fluid solution.
    Matched MeSH terms: Polyethylene Glycols
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links