Displaying publications 121 - 140 of 681 in total

Abstract:
Sort:
  1. Ng MH, Choo YM, Ma AN, Chuah CH, Hashim MA
    Lipids, 2004 Oct;39(10):1031-5.
    PMID: 15691027
    Previous reports showed that vitamin E in palm oil consists of various isomers of tocopherols and tocotrienols [alpha-tocopherol (alpha-T), alpha-tocotrienol, gamma-tocopherol, gamma-tocotrienol, and delta-tocotrienol), and this is normally analyzed using silica column HPLC with fluorescence detection. In this study, an HPLC-fluorescence method using a C30 silica stationary phase was developed to separate and analyze the vitamin E isomers present in palm oil. In addition, an alpha-tocomonoenol (alpha-T1) isomer was quantified and characterized by MS and NMR. (alpha-T1 constitutes about 3-4% (40+/-5 ppm) of vitamin E in crude palm oil (CPO) and is found in the phytonutrient concentrate (350+/-10 ppm) from palm oil, whereas its concentration in palm fiber oil (PFO) is about 11% (430+/-6 ppm). The relative content of each individual vitamin E isomer before and after interesterification/transesterification of CPO to CPO methyl esters, followed by vacuum distillation of CPO methyl esters to yield the residue, remained the same except for alpha-T and gamma-T3. Whereas alpha-T constitutes about 36% of the total vitamin E in CPO, it is present at a level of 10% in the phytonutrient concentrate. On the other hand, the composition of gamma-T3 increases from 31% in CPO to 60% in the phytonutrient concentrate. Vitamin is present at 1160+/-43 ppm, and its concentrations in PFO and the phytonutrient concentrate are 4,040+/-41 and 13,780+/-65 ppm, respectively. The separation and quantification of alpha-T1 in palm oil will lead to more in-depth knowledge of the occurrence of vitamin E in palm oil.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  2. Parthasarathy S, Ramanathan S, Murugaiyah V, Hamdan MR, Said MI, Lai CS, et al.
    Forensic Sci Int, 2013 Mar 10;226(1-3):183-7.
    PMID: 23385139 DOI: 10.1016/j.forsciint.2013.01.014
    Mitragyna speciosa, a native plant of Thailand and Malaysia known as 'ketum', is a plant of considerable interest. It exhibits strong antinociceptive effect and yet, acts like a psychostimulant. Due to the affordability and its ease of availability, the abuse of this plant as a substitute for other banned narcotics has become a major concern in many societies. In countries such as Thailand, Myanmar, Australia and Malaysia, the use of ketum is illegal. However, for a person to be charged for possessing or selling ketum, a reliable analytical method is needed in order to detect and identify the plant and its products. Mitragynine is the major alkaloid of ketum. This compound manifests its antinociceptive effects by acting on the opioid receptors. Since M. speciosa contain large quantity of mitragynine and it is exclusive to the species, the present analytical method is developed and validated for the purpose of screening ketum products based on this unique compound as the analytical marker. The method uses a HPLC-DAD system with Inertsil C8 (4.6 mm × 150 mm, 5 μm) as the column and a mixture of acetonitrile and formic acid, 50:50 (v/v), as the mobile phase. This method not only detects mitragynine, it can also be used to quantify the amount of mitragynine in the sample. The limit of detection is 0.25 μg/ml, while the limit of quantification is 0.50 μg/ml. The method is quick, simple and reliable with an accuracy of 97.27-101.74% and coefficient of variations of between 0.91 and 3.96%. The method has been tested and found suitable for the identification and quantification of mitragynine in dried plants, a variety of ketum extracts, as well as ketum drink obtained from the market.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  3. Nessa F, Ismail Z, Karupiah S, Mohamed N
    J Chromatogr Sci, 2005 Sep;43(8):416-20.
    PMID: 16212782
    A selective and sensitive reversed-phase (RP) high-performance liquid chromatographic method is developed for the quantitative analysis of five naturally occurring flavonoids of Blumea balsamifera DC, namely dihydroquercetin-7,4'-dimethyl ether (DQDE), blumeatin (BL), quercetin (QN), 5,7,3',5'-tetrahydroxyflavanone (THFE), and dihydroquercetin-4'-methyl ether (DQME). These compounds have been isolated using various chromatographic methods. The five compounds are completely separated within 35 min using an RP C18, Nucleosil column and with an isocratic methanol-0.5% phosphoric acid (50:50, v/v) mobile phase at the flow rate of 0.9 mL/min. The separation of the compounds is monitored at 285 nm using UV detection. Identifications of specific flavonoids are made by comparing their retention times with those of the standards. Reproducibility of the method is good, with coefficients of variation of 1.48% for DQME, 2.25% for THFE, 2.31% for QN, 2.23% for DQDE, and 1.51% for BL. The average recoveries of pure flavonoids upon addition to lyophilized powder and subsequent extraction are 99.8% for DQME, 99.9% for THFE, 100.0% for BL, 100.6% for DQDE, and 97.4% for QN.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  4. Saad B, Bari MF, Saleh MI, Ahmad K, Talib MK
    J Chromatogr A, 2005 May 06;1073(1-2):393-7.
    PMID: 15909546
    A reversed-phased HPLC method that allows the separation and simultaneous determination of the preservatives benzoic (BA) and sorbic acids (SA), methyl- (MP) and propylparabens (PP) is described. The separations were effected by using an initial mobile phase of methanol-acetate buffer (pH 4.4) (35:65) to elute BA, SA and MP and changing the mobile phase composition to methanol-acetate buffer (pH 4.4) (50:50) thereafter. The detector wavelength was set at 254 nm. Under these conditions, separation of the four components was achieved in less than 23 min. Analytical characteristics of the separation such as limit of detection, limit of quantification, linear range and reproducibility were evaluated. The developed method was applied to the determination of 67 foodstuffs (mainly imported), comprising soft drinks, jams, sauces, canned fruits/vegetables, dried vegetables/fruits and others. The range of preservatives found were from not detected (nd)--1260, nd--1390, nd--44.8 and nd--221 mg kg(-1) for BA, SA, MP and PP, respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Reddy AV, Jaafar J, Aris AB, Majid ZA, Umar K, Talib J, et al.
    J Sep Sci, 2015 Aug;38(15):2580-7.
    PMID: 25989063 DOI: 10.1002/jssc.201500250
    A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid-liquid extraction using 200 μL of human plasma extracted with methyl tert-butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 μm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 μL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra-day and inter-day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  6. Ramanathan S, Parthasarathy S, Murugaiyah V, Magosso E, Tan SC, Mansor SM
    Molecules, 2015 Mar 18;20(3):4915-27.
    PMID: 25793541 DOI: 10.3390/molecules20034915
    Varied pharmacological responses have been reported for mitragynine in the literature, but no supportive scientific explanations have been given for this. These studies have been undertaken without a sufficient understanding of the physicochemical properties of mitragynine. In this work a UV spectrophotometer approach and HPLC-UV method were employed to ascertain the physicochemical properties of mitragynine. The pKa of mitragynine measured by conventional UV (8.11 ± 0.11) was in agreement with the microplate reader determination (8.08 ± 0.04). Mitragynine is a lipophilic alkaloid, as indicated by a logP value of 1.73. Mitragynine had poor solubility in water and basic media, and conversely in acidic environments, but it is acid labile. In an in vitro dissolution the total drug release was higher for the simulated gastric fluid but was prolonged and incomplete for the simulated intestinal fluid. The hydrophobicity, poor water solubility, high variability of drug release in simulated biological fluids and acid degradable characteristics of mitragynine probably explain the large variability of its pharmacological responses reported in the literature. The determined physicochemical properties of mitragynine will provide a basis for developing a suitable formulation to further improve its solubility, stability and oral absorption for better assessment of this compound in preclinical studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  7. Kósa A, Cserháti T, Forgács E, Morais H, Mota T, Ramos AC
    J Chromatogr A, 2001 Apr 27;915(1-2):149-54.
    PMID: 11358243
    The colour pigments of five chili powders of different origins were separated and quantified by reversed-phase high-performance liquid chromatography (RP-HPLC). The similarities and dissimilarities of pigment composition of chili powders were elucidated by principal component analysis (PCA). RP-HPLC separated 50-100 pigment fractions depending on the detection wavelength and on the origin of chili powder. It was found that the pigment composition of chili powders from Malaysia and China and from India and Pakistan show marked similarities while the composition of colour pigments of chili powder from Thailand was different. It was further established that the chromatograms are similar in the first 5-35 min of development, they are highly different between 35 and 75 min and moderately different at the end of the chromatograms. It was concluded that RP-HPLC followed by PCA can be successfully used for the identification of chili powders according to the composition of their colour pigments.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  8. Ali N, Hashim NH, Yoshizawa T
    Food Addit Contam, 1999 Jul;16(7):273-80.
    PMID: 10656052
    For application to the analysis of aflatoxins (AF) in commercial peanut and corn products, the ISOLUTE multimode column (IMC, solid phase multifunctional column) method was validated by comparing with the modified Florisil column (MFC) method. Twenty-two peanut and eight corn products from Malaysia and the Philippines were analysed for AFB1, AFB2, AFG1 and AFG2 firstly by the MFC method and then by the IMC method. For peanut products, 14 out of 22 samples were positive by the two methods in the range of 1-378 micrograms/kg of AF, and correlation coefficients (r) for AFB1 and AFB2 were 0.987 and 0.997, respectively. For corn and corn products, all the samples were positive in the range of 1-130 micrograms/kg, and r values were 0.992 and 0.805 for AFB1 and AFB2 respectively. Thus, the results were significantly (p < 0.01) in close agreement, particularly for lower range of 1-50 micrograms/kg of AF concentrations in all the samples. For the occurrence of AF, 11 (65%) of peanut products from Malaysia were contaminated with AF at a mean level of 50 micrograms/kg (maximum 180 micrograms/kg) and two (40% products from the Philippines were contaminated with as high as 375 micrograms/kg and 177 micrograms/kg of AF, respectively. All the corn products from the Philippines were contaminated with AF at a mean level of 44 micrograms/kg (maximum 130 micrograms/kg). Contamination of commercial foods with high levels of AF is a very important issue to both the countries since these foods are very popular among children.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  9. Jones CR, Ovenell SM
    J. Chromatogr., 1979 Jun 11;163(2):179-85.
    PMID: 541369
    A high-performance liquid chromatographic method was developed to enable dapsone, monoacetyl dapsone and pyrimethamine to be measured simultaneously in plasma samples from volunteers in England and Malaysia who had been dosed with Maloprim. Mean half-lives of 25 and 80 h were calculated for dapsone and pyrimethamine, respectively, but there was wide individual variation. All subjects were found to be classifiable as "slow acetylators".
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  10. Tahmasebi-Boldaji R, Hatamipour MS, Khanahmadi M, Sadeh P, Najafipour I
    Ultrason Sonochem, 2019 Oct;57:89-97.
    PMID: 31208622 DOI: 10.1016/j.ultsonch.2019.05.018
    This paper presents the successful application of ultrasound-assisted packed-bed (UAE-PB) method for the extraction of hypericin from the Hypericum perfuratum L. The Soxhlet system was utilized for the determination of suitable solvent from ethanol, methanol or from the mixture of different proportions of ethanol-methanol. The mixture of 50:50 v/v ethanol-methanol was obtained to be the most suitable solvent since it led to the highest extraction amount of hypericin. The extraction amount of hypericin increased by 13.6% and 21.4% when the solvent changed from pure methanol to the mixture of 50:50 v/v ethanol-methanol for the extraction time of 3 and 8 h, respectively. Subsequently, the extraction was conducted through the UAE-PB, and the effects of temperature, time, and the ratio of solvent to the dried plant were studied. The response surface method (RSM) was used to investigate the effect of parameters on the extraction in the UAE-PB system. At the temperature of 60 °C, extraction time of 105 min, and the solvent to plant ratio of 15.3, the maximum extraction yield of hypericin was achieved. In the optimal conditions, the amount of extraction was 0.112 mg hypericin/g dried plant, which was in accordance with the optimized predicted value (0.111 mg hypericin/g dried plant) from Design-Expert software.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  11. Ali N, Hashim NH, Saad B, Safan K, Nakajima M, Yoshizawa T
    Food Chem Toxicol, 2005 Dec;43(12):1763-72.
    PMID: 16019122
    Traditional herbal medicines, popularly known as 'jamu' and 'makjun' in Malaysia and Indonesia, are consumed regularly to promote health. In consideration of their frequent and prolonged consumption, the natural occurrence of aflatoxins (AF) in these products was determined using immunoaffinity column clean-up and high-performance liquid chromatography with pre-column derivatization. The evaluated method, which entails dilution of sample extracts with Tween 20-phosphate buffered saline (1:9, v/v) and a chromatographic system using isocratic mobile phase composed of water-methanol-acetonitrile (70:20:10, v/v/v), was effective in separating AFB1, AFG1 and AFG2 from interference at their retention times. Results were confirmed using post-column derivatization with photochemical reactor. For 23 commercial samples analyzed, mean levels (incidence) of AFB(1), AFB(2) and AFG1 in positive samples were 0.26 (70%), 0.07 (61%) and 0.10 (30%) microg/kg, respectively; one sample was positive for AFG2 at a level of 0.03 (4%) microg/kg. In contrast to the high levels of AF in crude herbal drugs and medicinal plants reported previously by other researchers, the low contamination levels reported in this study may be attributed to the higher selectivity to AF of the method applied. Based on the AFB1 levels and the daily consumption of positive samples, a mean probable daily intake of 0.022 ng/kg body weight was calculated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  12. Sharma A, Kamble SH, León F, Chear NJ, King TI, Berthold EC, et al.
    Drug Test Anal, 2019 Aug;11(8):1162-1171.
    PMID: 30997725 DOI: 10.1002/dta.2604
    Kratom (Mitragyna speciosa) is a psychoactive plant popular in the United States for the self-treatment of pain and opioid addiction. For standardization and quality control of raw and commercial kratom products, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of ten key alkaloids, namely: corynantheidine, corynoxine, corynoxine B, 7-hydroxymitragynine, isocorynantheidine, mitragynine, mitraphylline, paynantheine, speciociliatine, and speciogynine. Chromatographic separation of diastereomers, or alkaloids sharing same ion transitions, was achieved on an Acquity BEH C18 column with a gradient elution using a mobile phase containing acetonitrile and aqueous ammonium acetate buffer (10mM, pH 3.5). The developed method was linear over a concentration range of 1-200 ng/mL for each alkaloid. The total analysis time per sample was 22.5 minutes. The analytical method was validated for accuracy, precision, robustness, and stability. After successful validation, the method was applied for the quantification of kratom alkaloids in alkaloid-rich fractions, ethanolic extracts, lyophilized teas, and commercial products. Mitragynine (0.7%-38.7% w/w), paynantheine (0.3%-12.8% w/w), speciociliatine (0.4%-12.3% w/w), and speciogynine (0.1%-5.3% w/w) were the major alkaloids in the analyzed kratom products/extracts. Minor kratom alkaloids (corynantheidine, corynoxine, corynoxine B, 7-hydroxymitragynine, isocorynantheidine) were also quantified (0.01%-2.8% w/w) in the analyzed products; however mitraphylline was below the lower limit of quantification in all analyses.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  13. Nair AB, Gandhi D, Patel SS, Morsy MA, Gorain B, Attimarad M, et al.
    Molecules, 2020 Oct 26;25(21).
    PMID: 33114598 DOI: 10.3390/molecules25214947
    Sinigrin, a precursor of allyl isothiocyanate, present in the Raphanus sativus exhibits diverse biological activities, and has an immense role against cancer proliferation. Therefore, the objective of this study was to quantify the sinigrin in the R. sativus roots using developed and validated RP-HPLC method and further evaluated its' anticancer activity. To achieve the objective, the roots of R. sativus were lyophilized to obtain a stable powder, which were extracted and passed through an ion-exchange column to obtain sinigrin-rich fraction. The RP-HPLC method using C18 analytical column was used for chromatographic separation and quantification of sinigrin in the prepared fraction, which was attained using the mobile phase consisting of 20 mM tetrabutylammonium: acetonitrile (80:20%, v/v at pH 7.0) at a flow rate of 0.5 mL/min. The chromatographic peak for sinigrin was showed at 3.592 min for pure sinigrin, where a good linearity was achieved within the concentration range of 50 to 800 µg/mL (R2 > 0.99), with an excellent accuracy (-1.37% and -1.29%) and precision (1.43% and 0.94%), for intra and inter-day, respectively. Finally, the MTT assay was performed for the sinigrin-rich fraction using three different human cancer cell lines, viz. prostate cancer (DU-145), colon adenocarcinoma (HCT-15), and melanoma (A-375). The cell-based assays were extended to conduct apoptotic and caspase-3 activities, to determine the mechanism of action of sinigrin in the treatment of cancer. MTT assay showed IC50 values of 15.88, 21.42, and 24.58 µg/mL for DU-145, HCT-15, and A-375 cell lines, respectively. Increased cellular apoptosis and caspase-3 expression were observed with sinigrin-rich fraction, indicating significant increase in overexpression of caspase-3 in DU-145 cells. In conclusion, a simple, sensitive, fast, and accurate RP-HPLC method was developed for the estimation of sinigrin in the prepared fraction. The data observed here indicate that sinigrin can be beneficial in treating prostate cancer possibly by inducing apoptosis.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  14. Che Zain MS, Osman MF, Lee SY, Shaari K
    Molecules, 2021 Feb 19;26(4).
    PMID: 33669484 DOI: 10.3390/molecules26041084
    Luteolin and apigenin derivatives present in oil palm (Elaeis guineensis) leaves (OPL) are reported to possess excellent antioxidant properties relating to numerous health benefits. To meet the global demand for flavonoids, OPL, which is plentifully generated as an agricultural by-product from oil palm plantations, can be further exploited as a new source of natural antioxidant compounds. However, to produce a standardized herbal preparation, validation of the quantification method for these compounds is required. Therefore, in this investigation, we developed and validated an improved and rapid analytical method, ultra-high-performance liquid chromatography equipped with ultraviolet/photodiode array (UHPLC-UV/PDA) for the quantification of 12 luteolin and apigenin derivatives, particularly focusing on flavonoid isomeric pairs: orientin/isoorientin and vitexin/isovitexin, present in various OPL extracts. Several validation parameters were assessed, resulting in the UHPLC-UV/PDA technique offering good specificity, linearity, accuracy, precision, and robustness, where the values were within acceptable limits. Subsequently, the validated method was employed to quantify luteolin and apigenin derivatives from OPL subjected to different drying treatments and extraction with various solvent systems, giving total luteolin (TLC) and apigenin content (TAC) in the range of 2.04-56.30 and 1.84-160.38 µg/mg extract, respectively. Additionally, partial least square (PLS) analysis disclosed the combination of freeze dry-aqueous methanol yielded OPL extracts with high TLC and TAC, which are strongly correlated with antioxidant activity. Therefore, we provide the first validation report of the UHPLC-UV/PDA method for quantification of luteolin and apigenin derivatives present in various OPL extracts, suggesting that this approach could be employed in standardized herbal preparations by adopting orientin, isoorientin, vitexin, and isovitexin as chemical markers.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  15. Soliman K, Jirjees F, Sonawane R, Sheshala R, Wang Y, Jones D, et al.
    J Chromatogr Sci, 2021 Jan 01;59(1):64-70.
    PMID: 33047781 DOI: 10.1093/chromsci/bmaa078
    Anti-glaucoma latanoprost-loaded ocular implants provide prolonged delivery and enhanced bioavailability relative to the conventional eye drops. This study aims at the development and validation of a reversed-phase high-performance liquid chromatography method for quantitative analysis of nanogram levels of latanoprost in the eye, and for the first time, compares the use of fluorescence vs ultraviolet (UV) detectors in latanoprost quantification. The mobile phase was composed of acetonitrile:0.1% v/v formic acid (60:40, v/v) with a flow rate of 1 mL/min and separation was done using a C18 column at temperature 40°C. The fluorescence excitation and emission wavelengths were set at 265 and 285 nm, respectively, while the UV absorption was measured at 200 nm. The latanoprost concentration-peak area relationship maintained its linearity (R2 = 0.9999) over concentration ranges of 0.063-10 μg/mL and 0.212-10 μg/mL for the fluorescence and UV detectors, respectively. The UV detector showed better precision, while the fluorescence detector exhibited higher robustness and greater sensitivity, with a detection limit of 0.021 μg/mL. The fluorescence detector was selected for quantification of latanoprost released from ocular implants in vitro and in porcine ocular tissues. The developed method is a robust, rapid and cost-effective alternative to liquid chromatography-mass spectrometry for routine analysis of latanoprost released from ocular implants.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Amiri A, Ghaemi F
    J Chromatogr A, 2021 Jul 05;1648:462168.
    PMID: 33984648 DOI: 10.1016/j.chroma.2021.462168
    In this research, the Cu-based metal-organic framework (MOF-199) was fabricated and coated on the stainless steel mesh as substrates through sol-gel procedure. Then the coated substrates were placed in a small column known as solid-phase extraction cartridge. The SPE based coated stainless steel mesh coupled with high-performance liquid chromatography-UV detector (HPLC-UV) was used for the fast extraction, and quantification of non-steroidal anti-inflammatory drugs (NSAIDs) from human plasma and water samples. To find optimum extraction conditions, the impacts of effective parameters on analytical performance like sample pH, sample volume, type, and volume of desorption solvent were optimized. At the optimized conditions, calibration graphs of analytes were linear in the concentration range of 0.03-300 ng mL-1 for water samples, and 0.1-200 ng mL-1 for plasma samples. The correlation coefficients were in the range of 0.9938 to 0.9989. Also, the limits of detection (LODs) were from 0.01 to 0.02 ng mL-1 for water samples and 0.03 to 0.1 ng mL-1 for plasma samples. The cartridge repeatability was studied at different values, and the relative standard deviations (RSDs%) were achieved between 3.5 and 5.1%. Consequently, this procedure was successfully used in the extraction and detection of NSAIDs in real water and plasma samples with relative recoveries ranged from 93.6 to 99.6%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  17. Salim SA, Sukor R, Ismail MN, Selamat J
    Toxins (Basel), 2021 04 15;13(4).
    PMID: 33920815 DOI: 10.3390/toxins13040280
    Rice bran, a by-product of the rice milling process, has emerged as a functional food and being used in formulation of healthy food and drinks. However, rice bran is often contaminated with numerous mycotoxins. In this study, a method to simultaneous detection of aflatoxins (AFB1, AFB2, AFG1, and AFG2), ochratoxin A (OTA), deoxynivalenol (DON), fumonisins (FB1 and FB2), sterigmatocystin (STG), T-2 toxin, HT-2 toxin, diacetoxyscirpenol (DAS) and zearalenone (ZEA) in rice bran was developed, optimized and validated using dispersive liquid-liquid microextraction (DLLME) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In DLLME, using a solvent mixture of methanol/water (80:20, v/v) as the dispersive solvent and chloroform as the extraction solvent with the addition of 5% salt improved the extraction recoveries (63-120%). The developed method was further optimized using the response surface methodology (RSM) combined with Box-Behnken Design (BBD). Under the optimized experimental conditions, good linearity was obtained with a correlation coefficient (r2) ≥ 0.990 and a limit of detection (LOD) between 0.5 to 50 ng g-1. The recoveries ranged from 70.2% to 99.4% with an RSD below 1.28%. The proposed method was successfully applied to analyze multi-mycotoxin in 24 rice bran samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid*
  18. Navaratnam V, Mansor SM, Chin LK, Mordi MN, Asokan M, Nair NK
    J Chromatogr B Biomed Appl, 1995 Jul 21;669(2):289-94.
    PMID: 7581905
    A selective reproducible high-performance liquid chromatographic assay for the simultaneous quantitative determination of the antimalarial compound artemether (ARM), dihydroartemisinin (DQHS) and artemisinin (QHS), as internal standard, is described. After extraction from plasma, ARM and DQHS were analysed using a Lichrocart/Lichrosphere 100 CN stainless-steel column and a mobile phase of acetonitrile-0.05 M acetic acid (15:85, v/v) adjusted to pH 5.0, and electrochemical detection in the reductive mode. The mean recovery of ARM and DQHS over a concentration range of 30-120 ng/ml was 81.6% and 93.4%, respectively. The within-day coefficients of variation were 0.89-7.01% for ARM and 3.45-8.11% for DQHS. The day-to-day coefficients of variation were 2.06-8.43% and 3.22-6.33%, respectively. The minimum detectable concentration for ARM and DQHS in plasma was 2.5 and 1.25 ng/ml for both compounds. The method was found to be suitable for use in clinical pharmacological studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  19. Cheah PY, Yuen KH, Liong ML
    J Chromatogr B Biomed Sci Appl, 2000 Aug 18;745(2):439-43.
    PMID: 11043762
    A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25-100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25-100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  20. Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Jun 12;710(1-2):243-6.
    PMID: 9686895
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5-4000 ng/ml.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links