Displaying publications 121 - 140 of 1723 in total

Abstract:
Sort:
  1. Md Saad M, Ali NS, Meon S
    Trop Life Sci Res, 2020 Apr;31(1):19-43.
    PMID: 32963709 DOI: 10.21315/tlsr2020.31.1.2
    Basal stem rot (BSR) is a devastating disease to Malaysian oil palm. Current techniques employed for BSR disease detection on oil palm are laborious, time consuming, costly, and subjected to accuracy limitations. An ergosterol detection method was developed, whereby it correlated well with the degree of infection in oil palm. This current study was designed to study the relationship between Ganoderma biomass, ergosterol concentration, BSR disease progress and to validate the efficiency of microwave assisted extraction (MAE) method for extraction of ergosterol compound. In addition, testing on the sensitivity of thin layer chromatography (TLC) analysis for detection of ergosterol was also the aim of this study. The optimised procedure involved extracting a small amount of Ganoderma-infected oil palm root tissues suspended in low volumes of solvent followed by irradiation in a conventional microwave oven at 70°C and medium high power for 30 s, resulting in simultaneous extraction and saponification. Based on the results obtained, MAE method may be effective in extracting low to high yields of ergosterol from infected oil palm roots demonstrating disease scale 2, 3 and 4. Positive relationship was observed between ergosterol content and inoculation period starting day 3 in the inoculated oil palm seedlings and hour 6 in germinated seeds. TLC analysis demonstrated a good correlation with high performance liquid chromatography (HPLC) quantification. Therefore, a semi-quantitative TLC analysis may be applied for handling a large amount of samples during onset field survey.
    Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Thin Layer
  2. Tan NH, Poh CH, Tan CS
    Toxicon, 1989;27(9):1065-70.
    PMID: 2799837
    Bungarus candidus venom exhibited high hyaluronidase, acetylcholinesterase and phospholipase A activities; low proteinase, 5'-nucleotidase, alkaline phosphomonoesterase and phosphodiesterase activities and moderately high L-amino acid oxidase activity. SP-Sephadex C-50 ion exchange chromatographic fractionation of the venom and Sephadex G-50 chromatography of the major lethal venom fractions indicate that the venom contains at least two highly lethal, basic phospholipases A with LD50 (i.v.) values of 0.02 micrograms/g (F6A) and 0.18 micrograms/g (F4A), respectively; as well as two polypeptide toxins with LD50 (i.v.) values of 0.17 micrograms/g and 0.83 micrograms/g, respectively. The major lethal toxin is the basic lethal phospholipase A, F6A, which accounts for approximately 13% of the venom protein and has a mol. wt of 21,000.
    Matched MeSH terms: Chromatography, Gel; Chromatography, Ion Exchange
  3. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  4. Julianto T, Yuen KH, Noor AM
    J Chromatogr B Biomed Sci Appl, 1999 Sep 10;732(1):227-31.
    PMID: 10517240
    A simple high-performance liquid chromatographic method using UV detection was developed for the determination of alpha-tocopherol in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile-tetrahydrofuran (3:2). The mobile phase comprised methanol-tetrahydrofuran (94:6) and analysis was run at a flow-rate of 1.5 ml/min with the detector operating at 292 nm. A Crestpak C18S (5 microm, 250 mm x 4.6 mm ID) was used for the chromatographic separation. The method had a mean recovery of 93%, while the within-day and between-day coefficients of variation and percentage errors were all less than 7%. The speed, specificity, sensitivity and reproducibility of this method make it particularly suitable for routine determination of alpha-tocopherol in human plasma. Moreover, only a small sample plasma volume (100 microl) is required for the analysis.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Wong CF, Peh KK, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1998 Oct 23;718(1):205-10.
    PMID: 9832378
    A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate-acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15-2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  6. Myint S, Daud WR, Mohamad AB, Kadhum AA
    J Chromatogr B Biomed Appl, 1996 Apr 26;679(1-2):193-5.
    PMID: 8998560
    An ethanolic extract of cloves was analyzed by gas chromatography directly to identify eugenol and other major phenolic compounds without previous separation of other components. Separation was performed on a fused-silica capillary column of 30 m x 0.53 mm I.D., 0.53 microns film thickness. The detector was a flame ionization detector. Helium gas at a flow-rate of 3 ml/min was used as a carrier gas. The analysis were performed with linear temperature programming. Nine components were detected and special attention was given to the major phenolic compound, eugenol.
    Matched MeSH terms: Chromatography, Gas/methods
  7. Mohd Adzim Khalili, R.,, Norhayati, A.H., Rokiah,M. Y., Asmah, R., Siti Muskinah, M., Abdul Manaf, A.
    MyJurnal
    This study was conducted to determine radical scavenging activity and vitamin antioxidant composition in red pitaya from organic plantation. For antioxidant vitamins analysis, a reverse-phase high performance liquid chromatography was used and radical scavenging activity of methanolic and water extract were determined using 1,1-diphenyl-2-pircrylhydrazyl assay. Results for radical scavenging activity, red pitaya methanolic extract achieved the highest percentage 70.13% compared with water extract (47.13%). Antioxidant vitamins composition in red pitaya showed that the concentration of vitamin A is 120.13 ± 0.69 μg/100 g freeze-dried sample, vitamin C is 540.27 ± 0.59 μg/100 g fresh samples and vitamin E is 105.67 ± 0.56 μg/100 g freeze-dried samples. This shows that red pitaya may become an alternative and potential source of natural antioxidant.
    Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Reverse-Phase
  8. Mohd Zainol, M.K., Abdul-Hamid A., Abu Bakar, F., Pak Dek, S.
    MyJurnal
    The effect of different drying methods on the degradation of flavonoids in Centella asiatica was evaluated. C. asiatica leaf, root and petiole were dried using air-oven, vacuum oven and freeze drier. Flavonoid was determined utilizing reverse-phase high performance liquid chromatography (RP-HPLC). Results of the study revealed the presence of high concentration of flavonoids in C. asiatica leaf, root and petiole, which include, naringin (4688.8 ± 69 μg/100 g, 3561.3 ± 205 μg/ 100 g, and 978.3 ± 96 μg/ 100 g), rutin (905.6 ± 123 μg/ 100 g, 756.07 ± 95 μg/ 100 g, and 557.25 ± 58 μg/ 100 g), quercetin (3501.1 ± 107 μg/ 100 g, 1086.31 ± 90 μg/ 100 g, and 947.63 ± 83 μg/ 100 g) and catechin (915.87 ± 6.01 μg/ 100 g, 400.6 ± 67 μg/ 100 g, and 250.56 ± 18 μg/ 100g). Luteolin, kaempferol and apigenin on the other hand, were inconsistently present in some parts of C. asiatica. Air-oven treatment resulted in the highest total flavonoids degradation followed by vacuum oven and freeze dried with percent degradation of 97%, 87.6% and 73%, respectively. Catechin and rutin were found to be the most stable flavonoids with percent degradation up to 35%, 66% and 76% for freeze dried, vacuum oven and air oven, respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Reverse-Phase
  9. Hidayah, N., Abu Bakar, F., Mahyudin, N.A., Faridah, S., Nur-Azura, M.S., Zaman, M.Z.
    MyJurnal
    This article summarises the current methods for total malachite green (MG) detection which is known as a sum of MG and leuco-malachite green (LMG) that has been used extensively in aquaculture as fungicide, dye color in textile and other purposes in food industries. LMG is a reducing form of MG, where the MG is easily reduced due to the photo-oxidative de-methylation process. Nevertheless, the use of MG had become an issue due to its toxicity effects. Many analytical instruments such as HPLC, LC—MS/MS, GC—MS, and spectrometry have been widely used for detection of MG. However, these methods require long time sample preparation and analysis, expensive, use hazardous reagents and indirect measurements. Hence, other analytical methods which are more sensitive, safe, rapid, inexpensive and portable are required. Alternatively, biosensors promise a more sensitive and rapid detection method for MG and LMG.
    Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Liquid
  10. Gan EK, Sam TW
    Med J Malaysia, 1976 Sep;31(1):33-5.
    PMID: 1023010
    Matched MeSH terms: Chromatography, Gas; Chromatography, Thin Layer
  11. Ping BTY, Aziz HA, Idris Z
    J Oleo Sci, 2018;67(3):265-272.
    PMID: 29491321 DOI: 10.5650/jos.ess17164
    High-Performance Liquid Chromatography (HPLC) methods via evaporative light scattering (ELS) and refractive index (RI) detectors are used by the local palm oil industry to monitor the TAG profiles of palm oil and its fractions. The quantitation method used is based on area normalization of the TAG components and expressed as percentage area. Although not frequently used, peak-area ratios based on TAG profiles are a possible qualitative method for characterizing the TAG of palm oil and its fractions. This paper aims to compare these two detectors in terms of peak-area ratio, percentage peak area composition, and TAG elution profiles. The triacylglycerol (TAG) composition for palm oil and its fractions were analysed under similar HPLC conditions i.e. mobile phase and column. However, different sample concentrations were used for the detectors while remaining within the linearity limits of the detectors. These concentrations also gave a good baseline resolved separation for all the TAGs components. The results of the ELSD method's percentage area composition for the TAGs of palm oil and its fractions differed from those of RID. This indicates an unequal response of TAGs for palm oil and its fractions using the ELSD, also affecting the peak area ratios. They were found not to be equivalent to those obtained using the HPLC-RID. The ELSD method showed a better baseline separation for the TAGs components, with a more stable baseline as compared with the corresponding HPLC-RID. In conclusion, the percentage area compositions and peak-area ratios for palm oil and its fractions as derived from HPLC-ELSD and RID were not equivalent due to different responses of TAG components to the ELSD detector. The HPLC-RID has a better accuracy for percentage area composition and peak-area ratio because the TAG components response equally to the detector.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  12. Babar ZM, Azizi WM, Ichwan SJ, Ahmed QU, Azad AK, Mawa I
    Nat Prod Res, 2019 Aug;33(15):2266-2270.
    PMID: 30037274 DOI: 10.1080/14786419.2018.1493587
    The current study provides a way of extraction for both active NSO and WSE from Nigella sativa seeds using 98% methanol. About 1 kg of ground seeds was macerated by 1:2.5 w/v (g/mL) for 72 hours. After rotary evaporation and 7 days of continuous drying and chilling at 50 and 4 °C, NSO and WSE were obtained at the same instant. Solubility tests of 24 solvents and 11 thin layer chromatographic analyses while 2, 2-diphenyl-1-picrylhydrazyl free radical scavenging assay of NSO (73.66) , WSE (33.32) and NSO + WSE (78.22) against ascorbic acid (IC50 = 4.28 mg/mL) was performed. WSE was found to be highly soluble in water and 5% NaOH exhibiting the same Rf value of 0.95 for EtOH:DMSO (9:1) against the honey. WSE has revealed more than twofold higher anti-oxidant activity than others. Formulation of WSE with Tualang honey may provide better targeted hydrophilic drug delivery systems.
    Matched MeSH terms: Chromatography, Thin Layer/methods
  13. Zainal Abidin SA, Rajadurai P, Chowdhury MEH, Ahmad Rusmili MR, Othman I, Naidu R
    Basic Clin Pharmacol Toxicol, 2018 Nov;123(5):577-588.
    PMID: 29908095 DOI: 10.1111/bcpt.13060
    The aim of this study was to investigate the cytotoxic, antiproliferative activity and the induction of apoptosis by L-amino acid oxidase isolated from Calloselasma rhodostoma crude venom (CR-LAAO) on human colon cancer cells. CR-LAAO was purified using three chromatographic steps: molecular exclusion using G-50 gel filtration resin, ion-exchange by MonoQ column and desalted on a G25 column. The purity and identity of the isolated CR-LAAO was confirmed by SDS-PAGE and LC-MS/MS. CR-LAAO demonstrated time- and dose-dependent cytotoxic activity on SW480 (primary human colon cancer cells) and SW620 (metastatic human colon cancer cells) with an EC50 values of 6 μg/ml and 7 μg/ml at 48 hr, respectively. Quantification of apoptotic cells based on morphological features demonstrated significant increase in apoptotic cell population in both SW480 and SW620 cells which peaked at 48 hr. Significant increase in caspase-3 activity and reduction in Bcl-2 levels were demonstrated following CR-LAAO treatment. These data provide evidence on the potential anticancer activity of CR-LAAO from the venom of C. rhodostoma for therapeutic intervention of human colon cancer.
    Matched MeSH terms: Chromatography, Gel; Chromatography, Liquid
  14. Eamsobhana P, Tungtrongchitr A, Wanachiwanawin D, Yong HS
    Int J Infect Dis, 2018 Aug;73:69-71.
    PMID: 29908250 DOI: 10.1016/j.ijid.2018.06.005
    OBJECTIVES: The serological diagnosis of human infection with Angiostrongylus cantonensis remains problematic because there are no commercially available validated tests. Most laboratories use domestically prepared tests such as the enzyme-linked immunosorbent assay (ELISA) or immunoblotting. Since laboratory facilities are not always available in endemic areas, we developed and assessed a rapid lateral flow immunochromatographic assay (AcQuickDx Test) to detect anti-A. cantonensis antibodies in human serum.

    METHODS: The test device was assembled with purified 31-kDa glycoprotein as diagnostic antigen and with gold-labelled anti-human immunoglublin-G as the detector reagent. A total of 97 serum samples were tested - 19 samples from clinically diagnosed patients with detectable A. cantonensis-specific antibody in immunoblotting; 43 samples from patients with other parasitic diseases, i.e. gnathostomiasis (n=13), toxocariasis (n=2), trichinellosis (n=2), hookworm infection (n=4), filariasis (n=5), cysticercosis (n=9), paragonimiasis (n=2), opisthorchiasis (n=3), and malaria (n=3); and 35 samples from normal healthy subjects.

    RESULTS: The sensitivity, specificity, positive predictive value and negative predictive value of AcQuickDx Test to detect anti-A. cantonensis specific antibodies in serologically confirmed angiostrongyliasis cases, were 100%, 98.72%, 95% and 100%, respectively. Positive AcQuickDx was observed in 1 of 4 cases with hookworm infections. No positive AcQuickDx was observed in cases with other parasitic diseases, and the individual healthy subjects.

    CONCLUSIONS: AcQuickDx Test is rapid, highly sensitive and specific, and easy to perform without additional equipment or ancillary supplies. It yields results that are interpreted visually, and possesses a long shelf-life at room temperature. Thus, it can be applied as an additional test for clinical diagnostic support of angiostrongyliasis either in conventional laboratories or for remote areas where laboratory infrastructure is not available.

    Matched MeSH terms: Chromatography, Affinity/methods*
  15. Lawal A, Tan GH, Alsharif AM
    J AOAC Int, 2016 Nov 01;99(6):1383-1394.
    PMID: 27667201 DOI: 10.5740/jaoacint.16-0272
    Food quality and food safety are major challenges affecting agricultural and industrial aspects of production. Many contaminants from different sources contaminate foods and drinks, leading to disastrous health problems like gene mutations and cancer. Previously, many different methods have been used for the analysis of these contaminants. Liquid-liquid extraction (LLE) has been the most well-known conventional technique used, but its limitations are its tediousness, time required, and the use of large quantities of toxic organic solvents. These limitations have led to the search for other, efficient techniques that are more environmentally friendly. Hence, this review highlights recent advances in liquid-phase (single-drop, hollow fiber, and dispersive liquid-liquid) microextraction procedures for food and drink analyses. Such modifications can be justified for solving limitations associated with the traditional LLE method. The objective of this review is to serve as a reference platform for providing effective management tools for solving problems of pollution, clean-up, and control of food quality and safety globally.
    Matched MeSH terms: Chromatography, Liquid; Gas Chromatography-Mass Spectrometry
  16. Tan CH, Tan KY, Tan NH
    Methods Mol Biol, 2019;1871:83-92.
    PMID: 30276733 DOI: 10.1007/978-1-4939-8814-3_5
    Snake venoms are complex mixtures of proteins and peptides that play vital roles in the survival of venomous snakes. As with their diverse pharmacological activities, snake venoms can be highly variable, hence the importance of understanding the compositional details of different snake venoms. However, profiling venom protein mixtures is challenging, in particular when dealing with the diversity of protein subtypes and their abundances. Here we described an optimized strategy combining a protein decomplexation method with in-solution trypsin digestion and mass spectrometry of snake venom proteins. The approach involves the integrated use of C18 reverse-phase high-performance liquid chromatography (RP-HPLC), sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), and nano-electrospray ionization tandem mass spectrometry (nano-ESI-LC-MS/MS).
    Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Reverse-Phase
  17. Zihad SMNK, Bhowmick N, Uddin SJ, Sifat N, Rahman MS, Rouf R, et al.
    Front Pharmacol, 2018;9:1164.
    PMID: 30374304 DOI: 10.3389/fphar.2018.01164
    Present study was undertaken to evaluate the analgesic activity of the ethanol extract of Chrysopogon aciculatus. In addition to bioassays in mice, chemical profiling was done by LC-MS and GC-MS to identify phytochemicals, which were further docked on the catalytic site of COX-2 enzymes with a view to suggest the possible role of such phytoconstituents in the observed analgesic activity. Analgesic activity of C. aciculatus was evaluated by acetic acid induced writhing reflex method and hot plate technique. Phytochemical profiling was conducted using liquid chromatography mass spectrometry (LC-MS) and gas chromatography mass spectrometry (GC-MS). In docking studies, homology model of human COX-2 enzyme was prepared using Easy Modeler 4.0 and the identified phytoconstituents were docked using Autodock Vina. Preliminary acute toxicity test of the ethanol extract of C. aciculatus showed no sign of mortality at the highest dose of 4,000 mg/kg. The whole plant extract significantly (p < 0.05) inhibited acetic acid induced writhing in mice at the doses of 500 and 750 mg/kg. The extract delayed the response time in hot plate test in a dose dependent manner. LC-MS analysis of the plant extract revealed the presence of aciculatin, nudaphantin and 5α,8α-epidioxyergosta-6,22-diene-3β-ol. Three compounds namely citronellylisobutyrate; 2,4-dihydroxy-7-methoxy-(2H)-1,4-benzoxazin-3(4H)-one and nudaphantin were identified in the n-hexane fraction by GC-MS. Among these compounds, six were found to be interacting with the binding site for arachidonic acid in COX-2 enzyme. Present study strongly supports the traditional use of C. aciculatus in the management of pain. In conclusion, compounds (tricin, campesterol, gamma oryzanol, and citronellyl isobutyrate) showing promising binding affinity in docking studies, along with previously known anti-inflammatory compound aciculatin can be held responsible for the observed activity.
    Matched MeSH terms: Chromatography, Liquid; Gas Chromatography-Mass Spectrometry
  18. Baharum SN, Azizan KA
    Adv Exp Med Biol, 2018 11 2;1102:51-68.
    PMID: 30382568 DOI: 10.1007/978-3-319-98758-3_4
    Over the last decade, metabolomics has continued to grow rapidly and is considered a dynamic technology in envisaging and elucidating complex phenotypes in systems biology area. The advantage of metabolomics compared to other omics technologies such as transcriptomics and proteomics is that these later omics only consider the intermediate steps in the central dogma pathway (mRNA and protein expression). Meanwhile, metabolomics reveals the downstream products of gene and expression of proteins. The most frequently used tools are nuclear magnetic resonance (NMR) spectroscopy and mass spectrometry (MS). Some of the common MS-based analyses are gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). These high-throughput instruments play an extremely crucial role in discovery metabolomics to generate data needed for further analysis. In this chapter, the concept of metabolomics in the context of systems biology is discussed and provides examples of its application in human disease studies, plant responses towards stress and abiotic resistance and also microbial metabolomics for biotechnology applications. Lastly, a few case studies of metabolomics analysis are also presented, for example, investigation of an aromatic herbal plant, Persicaria minor metabolome and microbial metabolomics for metabolic engineering applications.
    Matched MeSH terms: Chromatography, Liquid; Gas Chromatography-Mass Spectrometry
  19. Che Hussian CHA, Raja Abd Rahman RNZ, Thean Chor AL, Salleh AB, Mohamad Ali MS
    PeerJ, 2018;6:e5833.
    PMID: 30479887 DOI: 10.7717/peerj.5833
    T1 Lipase is a thermostable secretary protein of Geobacillus zalihae strain previously expressed in a prokaryotic system and purified using three-step purification: affinity 1, affinity 2, and ion exchange chromatography (IEX). This approach is time consuming and offers low purity and recovery yield. In order to enhance the purification strategy of T1 lipase, affinity 2 was removed so that after affinity 1, the cleaved Glutathione S-transferase (GST) and matured T1 lipase could be directly separated through IEX. Therefore, a rational design of GST isoelectric point (pI) was implemented by prediction using ExPASy software in order to enhance the differences of pI values between GST and matured T1 lipase. Site-directed mutagenesis at two locations flanking the downstream region of GST sequences (H215R and G213R) was successfully performed. Double point mutations changed the charge on GST from 6.10 to 6.53. The purified lipase from the new construct GST tag mutant-T1 was successfully purified using two steps of purification with 6,849 U/mg of lipase specific activity, 33% yield, and a 44-fold increase in purification. Hence, the increment of the pI values in the GST tag fusion T1 lipase resulted in a successful direct separation through IEX and lead to successful purification.
    Matched MeSH terms: Chromatography, High Pressure Liquid; Chromatography, Ion Exchange
  20. Ibrahim WAW, Wahib SMA, Hermawan D, Sanagi MM
    Methods Mol Biol, 2019;1985:407-416.
    PMID: 31069749 DOI: 10.1007/978-1-4939-9438-0_24
    Particular attention has been paid to capillary electrophoresis as versatile and environmentally friendly approach for enantioseparations of a wide spectrum of compounds. Cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) is a method of choice to provide effective separation toward hydrophobic and uncharged stereoisomers. The chiral discrimination of the solutes relies upon the partitioning between a given CD in the aqueous phase and micelles formed from a surfactant. Synergistic combinations of chiral selectors, surfactant, and modifier contribute to successful enantioseparations of the enantiomers. In this chapter, an application of CD-MEKC for the enantioseparation of selected imidazole drugs employing a dual CDs system is described.
    Matched MeSH terms: Chromatography, Micellar Electrokinetic Capillary/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links