Displaying publications 141 - 160 of 276 in total

Abstract:
Sort:
  1. Mohamed Abdelrasoul, Jahangir Bin Kamaldin, Jer Ping Ooi, Ahmed Abd El-Fattah, Gihan Kotry, Omneya Ramadan, et al.
    MyJurnal
    Introduction: Melatonin (MEL) loaded alginate-chitosan/beta-tricalcium phosphate (Alg-CH/β-TCP) composite hy- drogel has been formulated as a scaffold for bone regeneration. MEL in the scaffold was anticipated to accelerate bone regeneration. The objective of this study is to observe signs of systemic toxicity and physical changes on surface defected bone for bone regenerative performance of the composite. Methods: The proximal-medial metaphyseal cortex of the left tibia of New Zealand white rabbit was the surgical site of the defect. A total of nine rabbits were randomly allocated to three groups; Group I; implanted with MEL loaded Alg-CH/β-TCP, Group II; Alg-CH/β-TCP and Group III defects were sham control. The rabbits were daily observed to determine systemic toxicity effects by composites. The physical changes to implanted site were observed using digital x-ray radiography and computerized tomography at weeks 0, 2, 4, 6 and 8 of post-implantation. Results: There were no clinical signs of systemic toxicity for all groups of rabbits. Digital radiography did not show adverse effects to the bone. Computerized tomography showed reduction in the area size and depth volume of the implantation site, but accelerated regeneration within the 8 weeks was not significantly different (P
    Matched MeSH terms: X-Rays
  2. A. N. Azahari, N. D.M Yusob, H.A. Saidun, N.K.Y Ali, R. Abdullah, R. Hashim, et al.
    MyJurnal
    Introduction: Various phantom with varied materials has been proposed to replace the human body. Besides, there is always a demand to use the local material as a phantom material, which is readily available and inexpensive. Wood is usually preferred because it is multifunction, environmentally friendly, low in toxic, inexpensive, as well as easy to use and prepare. Previous studies have found that Rhizophora spp. is a suitable natural source material and has been suggested due to its comparable dosimetric properties to commercial phantom. Methods: In this study, fabricated Rhizophora spp. particleboards phantom was opted as a solid-equivalent phantom medium at low energy photon beams using Gafchromic film x-ray quality assurance 2 (XRQA2). Additionally, the characteristics of XRQA2 film in the diagnostic energy range were generated. Results: Interestingly, the density of the fabricated Rhizophora spp particleboards was observed to have the same density with the water equivalent material (ρ= 1.00 g.cm-3) and has shown to have loosened agreement with PDD of water phantom at approximately 25% of the dose error. Also, further analysis using XRQA 2 film showed that energy was independent at different ranges. Conclusion: The analysis of fabricated Rhizophora spp particleboards undertaken here has extended our knowledge of the possibility of man- ufacturing cost-effective water equivalent phantom by using binder-less particleboard from Rhizophora spp. There- fore, a definite need for smaller interspacing particles should be considered to elevate the potential of Rhizophora spp particle boards as water equivalent materials.
    Matched MeSH terms: X-Rays
  3. Ching SM, Hassan F, Paimin F
    MyJurnal
    The National Clinical Practice Guideline in Tuberculosis (TB) was designed to improve the quality of tuberculosis care. However, it remains unknown whether primary care doctors adhere to it well. This audit aims to assess the quality of care in the process of TB contact tracing in a primary care setting. Methods: Data on TB contact tracing from 1st February 2013 to 15th February 2013 was obtained retrospectively from all medical records of diagnosed pulmonary TB in a public primary care clinic. All patients who fulfilled the inclusion and exclusion criteria were included in the study. Results: A total of 102 medical records of adult TB contacts were recruited. The median age of the TB contact was 34 (IQR=10) years and 65 % were male. Seventy two percent of the adult TB contact had a TBIS 10C3 form created, and 95% of the medical records were fully documented. History taking and physical examination were recorded on 97% and 99% of patients respectively during the first follow-up at the polyclinic. Eighty five percent and 100% of the patients had a chest-x-ray and sputum direct smear for acid-fast bacilli done respectively. The turn-up rate for the first, second, third and fourth visit was 100% to 32%, 10% and 2% respectively. Conclusion: The quality of care for adult TB contacts tracing in this clinical audit was found to be suboptimal. There is a difference between the current national guidelines and practice in the clinic. Certain measures to improve the quality of care for adult TB contact tracing
    are urgently needed.
    Matched MeSH terms: X-Rays
  4. Nur Aishah Jusnaidi, Nurul Fadhlina Ismail
    MyJurnal
    Assessing the repeat rate is crucial to reduce unnecessary dose to the patient by identifying the major cause for repeating the x-rays exposure to the patient and apply corrective measures. To analyse the repeat rate of routine lower limb projections in direct digital radiography (DR) from general radiology department of Pantai Klang Hospital. 26 months retrospective repeated radiograph was acquired from Picture Archiving and Communication System (PACS) at Hospital Pantai Klang. The retrieved radiographs were grouped based on the reason for the i radiographs being rejected which are incorrect positioning, incorrect collimation, patient movement, incorrect exposure factors, artefact, and other reasons. Total repeated radiographs retrieved for basic lower limbs projections were 13616. Knee was the highest repeted examination and the lowest repeat rate was tibia fibula. (repeat rate: knee = 1.04%, tibia fibula = 0.57%). incorrect positioning is the major causes for repeat exposure for all examinations type, followed by incorrect collimation, other categories, centring ray error, incorrect exposure factors and artifact.
    Matched MeSH terms: X-Rays
  5. Purmal, Kathiravan, Nambiar, Phrabhakaran
    Malaysian Dental Journal, 2008;29(2):104-112.
    MyJurnal
    Radiology is important in the diagnostic assessment, treatment and monitoring progress of patients having dental and maxillofacial diseases. The central question in dental radiology is whether there is any risk with regard to low doses of radiation and what are the necessary protection needed to prevent any hazardous outcome with X-raying. With the emergence of the new millennium, major changes are happening in the field of science and technology. More efficient equipments are being discovered and more researches are being conducted to elicit better understanding of the radiation process and its effect on the human health. This article will review the latest guidelines for proper radiographic practice from the USA and Europe. It will address topics like the risks from dental radiography, selection criteria, protection for patients and staff, improvement to X-ray equipments, room dimensions and lead lining requirements. We have limited our research to intraoral, panoramic and cephalometric radiographs because these are the radiographs or images that are commonly taken in the general practice setting. (Copied from article).
    Matched MeSH terms: X-Rays
  6. Yusof, Z.Y.M., Nambiar, P.
    Malaysian Dental Journal, 2007;28(1):51-58.
    MyJurnal
    Quality radiographs of diagnostic value are important in root canal treatment. The dentist who has knowledge and skills in the use of radiographs for diagnostic purposes has a professional responsibility to ensure that the radiographs are obtained with minimum risk of radiation dose to and for the benefit of the patient. This article reviews the effectiveness of radiography techniques required for successful root canal treatment with the patient’s interest in mind. Awareness of effectual radiographic techniques, their constraints and applicable techniques for improvements are discussed. It seeks to reduce potentially harmful ionising radiation dose to patients and optimise the use of X-rays to produce diagnostic radiographs during root canal treatment.
    Matched MeSH terms: X-Rays
  7. Baharum NN, Ariffin F, Hanafiah M, Sulaiman SH
    Korean J Fam Med, 2021 Jan;42(1):84-87.
    PMID: 32447880 DOI: 10.4082/kjfm.19.0021
    Avascular necrosis, or osteonecrosis of the femoral head, is a debilitating condition which leads to the destruction of the hip joint due to an interruption in the blood supply to the bony region and is most commonly due to trauma. The case discussed here has been highlighted as it presented as non-traumatic osteonecrosis of the femoral head with an absence of risk factors in a healthy adult male. A 37-year-old male presented with a 4-month history of recurrent left hip pain, which worsened with initiation of movement and weightbearing on the affected side. The patient was overweight but normotensive with a full range of movement of the hips bilaterally. There were no abnormalities detected on initial X-ray images of the left hip. However, due to the persistent pain and sclerotic changes in a subsequent X-ray, a magnetic resonance image of the bilateral hips was obtained, leading to the diagnosis of osteonecrosis of the bilateral femoral heads. Due to the lack of improvement with physiotherapy and analgesia, the patient was subjected to conservative surgery of the symptomatic left hip with concurring evidence of avascular necrosis based on intraoperative anatomical biopsy. This case emphasizes the importance of identifying underlying issues during history taking and physical examination in adults without risk factors. The early diagnosis of osteonecrosis assists in preventing joint collapse and can delay the requirement of joint replacements. High levels of suspicion are necessary to instigate investigation in persistent cases without the presence of risk factors.
    Matched MeSH terms: X-Rays
  8. Arinima P, Ishak A
    Korean J Fam Med, 2018 Jul;39(4):266-269.
    PMID: 29972896 DOI: 10.4082/kjfm.17.0117
    A 16-year-old Malay boy presented to Kota Bharu Health Care Centre, Kelantan, with left shoulder pain after sustaining a fall. On further history taking, it was noted that the pain preceded the fall by 1 month. The early changes of osteosarcoma were visible on an X-ray during the initial presentation; however, this was missed by the primary care doctors. Three months later, the patient presented with persistent pain in the left shoulder and was diagnosed with osteosarcoma.
    Matched MeSH terms: X-Rays
  9. Shakinah Salleh, Affrida Abu Hassan, Shuhaimi Shamsudin, Yahya Awang, Ab. Kahar Sandrang, Abdullah, Thohirah Lee
    MyJurnal
    Chrysanthemum morfolium is an important temperate cut flower and potted plant for Malaysian local market and exporter. Considering chrysanthemum as a popular vegetatively propagated ornamental plant, induce mutations for breeding purposes are more beneficial. Several of physical mutagens have been used in mutation breeding including x-rays, gamma rays and ion beams. Gamma rays and ion beams are from two different linear energy transfer (LET) which are low and high, respectively. The objective of this study was to compare the effectiveness of acute gamma and ion beam irradiation in generating flower colour mutations on nodal explants of Chrysanthemum morifblium cv. Reagan Red'. The nodal explants were irradiated with acute gamma (0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110 and 120 Gy) and ion beam (0, 0.5, 1.0, 2.0, 3.0, 5.0, 8.0, 10, 15, 20 and 30 Gy). The optimal dose for in vitro shoot regeneration using acute gamma was in the range of 10 to .15.0Gy and for ion beam was between 3.5 to 4.OGv. Relative biological effectiveness for ion beam was found 3.75 higher than the acute gamma. The regenerated plantlets were planted in the greenhouse at MARDI, Cameron Highland for morphological screening. The highest frequency of flower colour mutation for acute gamma was 77.8% whilst for ion beam were between 42.3 to 58.3%.
    Matched MeSH terms: X-Rays
  10. Khairiah Yazid @ Khalid, Roslan Yahya, Nadira Kamarudini, Mohd. Zaid Abdullah, Mohd Ashhar Khalid, Abdul Aziz Mohamed
    MyJurnal
    Detection and analysis of resin is particularly significant since the commercial value of agarwood is related to the quantity of resins that are present. This article explores the potential of a scanning electron microscope in combination with new non-destructive 3D visualization technique, X-ray micro-computed tomography, as imaging tools to visualize micro-structure resin in agarwood. These techniques were used to compare two samples of agarwood chips: high grade and low grade. From the results, it can be concluded that a wood cell filled with resin deposit have a higher attenuation. It can be shown that the combination of scanning electron microscopy and micro-CT can offer high resolution images concerning the localization and structure of resin inside Agarwood. While the second allows the 3D investigation of internal structure of agarwood, the first technique can provide details 2D morphological information. These imaging techniques, although sophisticated can be used for standard development especially in grading of agarwoodlbr commercial activities.
    Matched MeSH terms: X-Rays
  11. Husaini Salleh, Supian Samat, Mohd Khalid Matori, Muhammad Jamal Md Isa, Mohd Ramli Arshad, Shahrul Azlan Azizan, et al.
    MyJurnal
    Heel Effect is the well known phenomena in x-ray production. It contributes the effect to image
    formation and as well as scattered radiation. But there is paucity in the study related to heel effect.
    This study is for mapping and profiling the dose on the surface of water phantom by using mobile
    C-arm unit Toshiba SXT-1000A. Based on the result the dose profile is increasing up to at least
    about 57% from anode to cathode bound of the irradiated area. This result and information can be
    used as a guide to manipulate this phenomenon for better image quality and radiation safety for
    this specific and dedicated fluoroscopy unit.
    Matched MeSH terms: X-Rays
  12. Muhammad Rawi Mohamed Zin, Mahendrasingam, Arumugam, Konkel, Chris, Narayanan, Theyencheri
    MyJurnal
    Changes in molecular structure configuration during strain induced crystallisation of an amorphous Poly(Lactic Acid) (PLA 4032D) polymer was monitored in-situ by simultaneously recording the wide angle x-ray scattering (WAXS) and small angle x-ray scattering (SAXS) patterns together with polymer deformation images and force data. The amorphous chain orientation from the beginning of deformation until the onset of crystallisation was studied from the WAXS patterns. The true mechanical behaviour described by the true stress-true strain curve related to an amorphous chain orientation exhibited a linear behaviour. Approaching critical amorphous orientation, the true stress-true strain curve deviated from linear into non-linear behaviour. After the onset of crystallization, when the deformed polymer became a semicrystalline state, the true mechanical behaviour exhibited true strain hardening which greatly affected by the formation of the morphology. The gradual true strain hardening was associated with the formation of micro-fibrillar structure containing thin crystallite morphology whilst sharp increased in true strain hardening was associated with the formation of stacked lamellar morphology in the form of macro-lattice structure. The study was accomplished by the application of high brilliance synchrotron radiation at beamline ID2 of ESRF, Grenoble in France and the usage of the high contrast resolution of WAXS and SAXS charge-couple device (CCD) camera as well as 40 milliseconds temporal resolution of data acquisition system.
    Matched MeSH terms: X-Rays
  13. Amal Hayati Zainal Abidin, Khairul Osman, Sri Pawita Albakri Amir Hamzah, Noor Hazfalinda Hamzah, Ab Halim Mansar, Normaizatul Afizah Ismail
    MyJurnal
    The study was conducted to create specific formulae for stature estimation of adult male population in Malaysia based on measurements of femur, tibia and fibula lengths using radiographic method. A number of thirty two Malaysians from hospitals involved as subjects in this study. The subjects were Malays (14), Chinese (8) and Indians (10) from 25-45 years old. The standing height of the subject was recorded before femur, tibia and fibula were scanned with an x-ray
    machine. The bones length was measured on the x-ray film in centimetres (cm) and analysed using Statistical Package for Social Sciences (SPSS) version 19.0 for Windows. The results showed a significant relationship (p < 0.05) between stature and measurements of length of femur, tibia and fibula. Stature of Malays and Indians were significant (p < 0.05) with measurements of length of femur, tibia and fibula but insignificant in Chinese. Simple Linear Regression Analysis was used to derive regression equation for single bone and Multiple Linear Regression Analysis was used to derive regression equation for combination of femur, tibia and fibula. Six formulae for stature estimation of adult male population in Malaysia were derived. The formulae consist of three formulae for single bone, a formulae for combination bones with unknown race, a formulae for combination bones of Malays population and a formulae for combination bones of Indians population. Formulae for combination bones had the highest correlation coefficient compared to the formula using a single bone. Standard error was found to be high in all the formulae due to small sample size. Extension for this study is essential to provide Malaysia with accurate formulae.
    Matched MeSH terms: X-Rays
  14. Halmi Shamsudin, Norman Nordin, Sa’don Samian, Hafiz Salahudin, Azrul, A.B., Nik Azuan, N.I., et al.
    Jurnal Inovasi Malaysia, 2018;2(1):31-50.
    MyJurnal
    Angiography procedures is one of the diagnostic imaging procedures for studying blood vessels in the arteries and veins. This angiography examination is performed by injecting a viscous liquid called contrast media into the blood vessels to clearly identify the blocked blood vessels. This procedure involves the exposure of X-Ray in certain blood vessels and is performed by the Interventionist Radiologist. There are several types of angiography examinations which include cerebral angiography, coronary angiography, pulmonary angiography, peripheral angiography and renal angiography. The main problem that occurs during the Lower Limb Angiography examination involving elderly patients aged 60 years and above who suffer from critical diabetes stage in both blood vessels. The problem arise when there is no special immobilize device to support the foot and the patients were in an uncomfortable state for a period of 2-3 hours during the examination. Hence specialists had difficulty to interpret accurately the blood vessel clot in the foot due to less optimum radiograph. IMMOLIMBTM is an innovative invention created from used waste to overcome the foot movements, providing comfort and enhancing optimum diagnostic images.
    Matched MeSH terms: X-Rays
  15. Chan PW, Goh AY, Lum LC
    J Trop Pediatr, 2000 Aug;46(4):234-6.
    PMID: 10996986
    Twenty-two (42 per cent) out of 52 patients admitted with severe bronchiolitis to our Paediatric Intensive Care Unit required ventilation. Risk factors associated with ventilation included a younger mean age, female sex, low birthweight, failure to thrive and the presence of an underlying illness. Ventilated patients were also more likely to have a higher respiratory distress assessment index (RDAI) score, pneumonic infiltration on chest X-ray, lower serum sodium and a positive respiratory syncytial virus isolation in the tracheal secretion.
    Matched MeSH terms: X-Rays
  16. Rais NNM, Bradley DA, Hashim A, Isa NM, Osman ND, Ismail I, et al.
    J Radiol Prot, 2019 Sep;39(3):N8-N18.
    PMID: 31018196 DOI: 10.1088/1361-6498/ab1c16
    Novel germanium (Ge)-doped silica glass fibres tailor-made in Malaysia are fast gaining recognition as potential media for thermoluminescence (TL) dosimetry, with active research ongoing into exploitation of their various beneficial characteristics. Investigation is made herein of the capability of these media for use in diagnostic imaging dosimetry, specifically at the radiation dose levels typically obtained in conduct of Computed Tomography (CT). As a first step within such efforts, there is need to investigate the performance of the fibres using tightly defined spectra, use being made of a Philips constant potential industrial x-ray facility, Model MG165, located at the Malaysian Nuclear Agency Secondary Standards Dosimetry Lab (SSDL). Standard radiation beam qualities (termed RQT) have been established for CT, in accord with IEC 61267: 2003 and IAEA Technical Reports Series No. 457: 2007. A calibrated ionisation chamber has also been utilised, forming a component part of the SSDL equipment. The fabricated fibres used in this study are 2.3 mol% flat fibre (FF) of dimensions 643 × 356 μm2 and 2.3 mol% cylindrical fibre (CF) of 481 μm diameter, while the commercial fibre used is 4 mol% with core diameter of 50 μm. The dopant concentrations are nominal preform values. The fibres have been irradiated to doses of 20, 30 and 40 milligray (mGy) for each of the beam qualities RQT 8, RQT 9 and RQT 10. For x-rays generated at constant potential values from 100 to 150 kV, a discernible energy-dependent response is seen, comparisons being made with that of lithium fluoride (LiF) thermoluminescence dosimeters (TLD-100). TL yield versus dose has also been investigated for x-ray doses from 2 to 40 mGy, all exhibiting linearity. Compared to TLD-100, greater sensitivity is observed for the fibres.
    Matched MeSH terms: X-Rays
  17. Chew MT, Nisbet A, Suzuki M, Matsufuji N, Murakami T, Jones B, et al.
    J Radiat Res, 2019 Jan 01;60(1):59-68.
    PMID: 30452663 DOI: 10.1093/jrr/rry081
    Glioblastoma (GBM), a Grade IV brain tumour, is a well-known radioresistant cancer. To investigate one of the causes of radioresistance, we studied the capacity for potential lethal damage repair (PLDR) of three altered strains of GBM: T98G, U87 and LN18, irradiated with various ions and various levels of linear energy transfer (LET). The GBM cells were exposed to 12C and 28Si ion beams with LETs of 55, 100 and 200 keV/μm, and with X-ray beams of 1.7 keV/μm. Mono-energetic 12C ions and 28Si ions were generated by the Heavy Ion Medical Accelerator at the National Institute of Radiological Science, Chiba, Japan. Clonogenic assays were used to determine cell inactivation. The ability of the cells to repair potential lethal damage was demonstrated by allowing one identical set of irradiated cells to repair for 24 h before subplating. The results show there is definite PLDR with X-rays, some evidence of PLDR at 55 keV/μm, and minimal PLDR at 100 keV/μm. There is no observable PLDR at 200 keV/μm. This is the first study, to the authors' knowledge, demonstrating the capability of GBM cells to repair potential lethal damage following charged ion irradiations. It is concluded that a GBM's PLDR is dependent on LET, dose and GBM strain; and the more radioresistant the cell strain, the greater the PLDR.
    Matched MeSH terms: X-Rays
  18. Razali MH, Noor AFM, Yusoff M
    J Nanosci Nanotechnol, 2020 02 01;20(2):965-972.
    PMID: 31383093 DOI: 10.1166/jnn.2020.16944
    In this study, a series of copper-ion-doped titanium dioxide (Cu-ion-doped TiO₂) nanotubes (NTs) were synthesized via a hydrothermal method by the concentration variation of doped Cu ions (0.00, 0.50, 1.00, 2.50, and 5.00 mmol). In addition, the samples were characterized using X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), nitrogen gas adsorption measurements, and ultraviolet-visible (UV-Vis) diffuse-reflectance spectroscopy. The photocatalytic activity of the Cu-iondoped TiO₂ NTs was investigated for the degradation of methyl orange (MO) under sunlight. The results obtained from the structural and morphological studies revealed that, at low concentrations of Cu-doped TiO₂ NTs, Cu is incorporated into the interstitial positions of the TiO₂ lattice, affording a new phase of TiO₂ (hexagonal) instead of the anatase TiO₂ (tetragonal) observed for undoped TiO₂ NTs. EDX analysis confirmed the presence of Cu in the TiO₂-based photocatalyst. All of the investigated samples exhibited a hollow fibrous-like structure, indicative of an NT morphology. The inner and outer diameters of the NTs were 4 nm and 10 nm, respectively. The photocatalysts exhibited a large surface area due to the NT morphology and a type IV isotherm and H3 hysteresis, corresponding to the mesopores and slit-shaped pores. The Cu-ion-doped TiO₂ NTs were excited by sunlight because of their low bandgap energy; and after the incorporation of Cu ions into the interstitial positions of the TiO₂ lattice, the NTs exhibited high visible-light activity owing to the low bandgap.
    Matched MeSH terms: X-Rays
  19. Fayyadh OA, Arifin INA, Khairudin A, Hassan J, Abubakar S, Talib ZA, et al.
    J Nanosci Nanotechnol, 2020 May 01;20(5):3157-3163.
    PMID: 31635660 DOI: 10.1166/jnn.2020.17386
    Indium antimonide nanowires were synthesized by electrochemical deposition using anodic aluminum oxide template in the presence of gold film as conductive layers. Field emission scanning electron microscopy and energy dispersive X-ray spectrometry measurements were carried out to investigate the effect of adhesive insulated tape covered below the conductive layer. Results showed that the anodic aluminum oxide template covered with insulating tapes had better morphology with less presence of overgrown rough film on the topside of the anodic aluminum oxide template and it exhibited a smoother nanowire sidewall as compared to the uncovered ones. Additionally, the unique properties of anodic aluminum oxide were controllable pore diameter with a narrow size distribution at some intervals. It was evident from the energy dispersive X-ray spectrum that the nanowires synthesized from the covered template condition exhibited better InSb composition and stoichiometric ratio compared to the uncovered template condition.
    Matched MeSH terms: X-Rays
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links