Displaying publications 161 - 180 of 191 in total

Abstract:
Sort:
  1. Chandralekha G, Jeganathan R, Viswanathan, Charan JC
    Malays J Med Sci, 2005 Jan;12(1):51-6.
    PMID: 22605947
    Even though extensive studies have been conducted on the effect of noise exposure on hearing apparatus / auditory system, information on the effect of noise on the other body functions is sparse. The present study examined the effect of exposure of albino rats to acute and chronic noise stress on two important interlaced endocrine levels. In acute experiments the animals were exposed to 120 dB noise for a duration of 1, 2, 3 hrs. In chronic experiments the animals were exposed to noise for one hour daily for 30, 60 and 90 days. Plasma corticosterone and leptin levels were measured in these animals. There was significant elevation in the levels of corticosterone and leptin after exposure to noise stress. The elevation in corticosterone level after noise stress is in agreement with earlier reports. So noise acts like a stressor and elevates the secretion of the corticosterone, the stress hormone and leptin, the product of the ob gene there is an elevation in leptin levels after noise stress.
    Matched MeSH terms: Noise
  2. Maamor N, Billings CJ
    Neurosci Lett, 2017 01 01;636:258-264.
    PMID: 27838448 DOI: 10.1016/j.neulet.2016.11.020
    The purpose of this study was to determine the effects of noise type, signal-to-noise ratio (SNR), age, and hearing status on cortical auditory evoked potentials (CAEPs) to speech sounds. This helps to explain the hearing-in-noise difficulties often seen in the aging and hearing impaired population. Continuous, modulated, and babble noise types were presented at varying SNRs to 30 individuals divided into three groups according to age and hearing status. Significant main effects of noise type, SNR, and group were found. Interaction effects revealed that the SNR effect varies as a function of noise type and is most systematic for continuous noise. Effects of age and hearing loss were limited to CAEP latency and were differentially modulated by energetic and informational-like masking. It is clear that the spectrotemporal characteristics of signals and noises play an important role in determining the morphology of neural responses. Participant factors such as age and hearing status, also play an important role in determining the brain's response to complex auditory stimuli and contribute to the ability to listen in noise.
    Matched MeSH terms: Signal-To-Noise Ratio*
  3. Masoud F, Sapuan SM, Ariffin MKAM, Nukman Y, Bayraktar E
    Polymers (Basel), 2021 Feb 26;13(5).
    PMID: 33652612 DOI: 10.3390/polym13050706
    In this paper, the influence of processing input parameters on the heat-affected zone (HAZ) of three different material thicknesses of sugar palm fiber reinforced unsaturated polyester (SPF-UPE) composites cut with a CO2 laser was investigated. Laser power, traverse speed, and gas pressure were selected as the most influential input parameters on the HAZ to optimize the HAZ response with fixing all of the other input parameters. Taguchi's method was used to determine the levels of parameters that give the best response to the HAZ. The significance of input parameters was also determined by calculating the max-min variance of the average of the signal-to-noise ratio (S/N) ratio for each parameter. Analysis of variation (ANOVA) was used to determine each input parameter's contribution to the influence on HAZ depth. The general results show that the minimum levels of laser power and the highest levels of traverse speed and gas pressure gave the optimum response to the HAZ. Gas pressure had the most significant effect on the HAZ, with contribution decreases as the material thickness increased, followed by the traverse speed with contribution increases with the increase in material thickness. Laser power came third, with a minimal contribution to the effect on the HAZ, and it did not show a clear relationship with the change in material thickness. By applying the optimum parameters, the desired HAZ depth could be obtained at relatively low values.
    Matched MeSH terms: Signal-To-Noise Ratio
  4. Salina H, Abdullah A, Mukari SZ, Azmi MT
    Eur Arch Otorhinolaryngol, 2010 Apr;267(4):495-9.
    PMID: 19727788 DOI: 10.1007/s00405-009-1080-y
    Transient-evoked otoacoustic emission (TEOAE) is a well-established screening tool for universal newborn hearing screening. The aims of this study are to measure the effects of background noise on recording of TEOAE and the duration required to complete the test at various noise levels. This study is a prospective study from June 2006 until May 2007. The study population were newborns from postnatal wards who were delivered at term pregnancy. Newborns who were more than 8-h old and passed a hearing screening testing using screening auditory brainstem response (SABRe) were further tested with TEOAE in four different test environments [isolation room in the ward during non-peak hour (E1), isolation room in the ward during peak hour (E2), maternal bedside in the ward during non-peak hour (E3) and maternal bedside in the ward during peak hour (E4)]. This study showed that test environment significantly influenced the time required to complete testing in both ears with F [534.23] = 0.945; P < 0.001 on the right ear and F [636.54] = 0.954; P < 0.001 on the left. Our study revealed that TEOAE testing was efficient in defining the presence of normal hearing in our postnatal wards at maternal bedside during non-peak hour with a specificity of 96.8%. Our study concludes that background noise levels for acceptable and accurate TEOAE recording in newborns should not exceed 65 dB A. In addition, when using TEOAE assessment in noisy environments, the time taken to obtain accurate results will greatly increase.
    Matched MeSH terms: Noise*
  5. Zakaria MN, Abdul Wahab NA, Awang MA
    Noise Health, 2017 12 2;19(87):112-113.
    PMID: 29192621 DOI: 10.4103/nah.NAH_2_17
    Matched MeSH terms: Noise, Occupational*
  6. Saffree Jeffree M, Ismail N, Awang Lukman K
    J Occup Health, 2016 Sep 30;58(5):434-443.
    PMID: 27488035
    INTRODUCTION: Hearing impairment remains the main occupational health problem in the manufacturing industry, and its contributing factors have not been well controlled.

    METHODS: Unmatched case control and comparative studies were carried out among fertilizer factory workers in Sarawak with the aim of determining contributing factors for hearing impairment. Respondents consisted of 49 cases that were diagnosed from 2005 to 2008 with 98 controls from the same work places. Chi-square test and Mann-Whitney test were used in a univariate analysis to determine the association between hearing impairment and the contributing risks being studied.

    RESULTS: The results of the univariate analysis showed that hearing impairment was significantly (p<0.05) associated with older age, lower education level, high smoking dose, high occupational daily noise dose, longer duration of service, infrequent used of hearing protection device (HPD), and low perception of sound on HPD usage. Multivariate logistic regression of hearing impairment after controlling for age found the following five variables: occupational daily noise dose ≥50% (OR 3.48, 95% CI 1.36-8.89), ≥15 years of services (OR 2.92, 95% CI 1.16-7.33), infrequent use of HPD (OR 2.79, 95% CI 1.15-6.77), low perception of sound on HPD (POR 2.77, 95% CI 1.09-6.97), and smoking more than 20 packs per year (OR 4.71, 95% CI 1.13-19.68).

    DISCUSSION: In conclusion, high occupational noise exposure level, longer duration of service, low perception of sound on HPD, infrequent used of HPD, and smoking more than 20 packs per year were the contributing factors to hearing impairment, and appropriate intervention measures should be proposed and taken into considerations.

    Matched MeSH terms: Hearing Loss, Noise-Induced/etiology*; Hearing Loss, Noise-Induced/prevention & control; Noise, Occupational/adverse effects*
  7. Hanafi SA, Zulkifli I, Ramiah SK, Chung ELT, Kamil R, Awad EA
    Poult Sci, 2023 Feb;102(2):102390.
    PMID: 36608455 DOI: 10.1016/j.psj.2022.102390
    Prenatal stress may evoke considerable physiological consequences on the developing poultry embryos and neonates. The present study aimed to determine prenatal auditory stimulation effects on serum levels of ceruloplasmin (CPN), alpha-1-acid glycoprotein (AGP), corticosterone (CORT), and heat shock protein 70 (Hsp70) regulations in developing chicken embryos and newly hatched chicks. Hatching eggs were subjected to the following auditory treatments; 1) control (no additional sound treatment other than the background sound of the incubator's compressors at 40 dB), 2) noise exposure (eggs were exposed to pre-recorded traffic noise at 90 dB) (NOISE), and 3) music exposure (eggs were exposed to Mozart's Sonata for Two Pianos in D Major, K 488 at 90 dB) (MUSIC). The NOISE and MUSIC treatments were for 20 min/h for 24 h (a total of 8 h/d), starting from embryonic days (ED) 12 to hatching. The MUSIC (1.37 ± 0.1 ng/mL) and NOISE (1.49 ± 0.2 ng/mL) treatments significantly elevated CPN at ED 15 compared to the Control (0.82 ± 0.04 ng/mL) group and post-hatch day 1 (Control, 1.86 ± 0.2 ng/mL; MUSIC, 2.84 ± 0.4 ng/mL; NOISE, 3.04 ± 0.3 ng/mL), AGP at ED 15 (Control, 39.1 ± 7.1 mg/mL; MUSIC, 85.5 ± 12.9 mg/mL; NOISE, 85.4 ± 15.1 mg/mL) and post-hatch day 1 (Control, 20.4 ± 2.2 mg/mL; MUSIC, 30.5 ± 4.7 mg/mL; NOISE, 30.3 ± 1.4 mg/mL). CORT significantly increased at ED 15 in both MUSIC (9.024 ± 1.4 ng/mL) and NOISE (12.15 ± 1.6 ng/mL) compared to the Control (4.39 ± 0.7 ng/mL) group. On the other hand, MUSIC exposed embryos had significantly higher Hsp70 expression than their Control and NOISE counterparts at ED 18 (Control, 12.9 ± 1.2 ng/mL; MUSIC, 129.6 ± 26.4 ng/mL; NOISE, 13.3 ± 2.3 ng/mL) and post-hatch day 1 (Control, 15.2 ± 1.7 ng/mL; MUSIC, 195.5 ± 68.5 ng/mL; NOISE, 13.2 ± 2.7 ng/mL). In conclusion, developing chicken embryos respond to auditory stimulation by altering CPN, AGP, CORT, and Hsp70. The alterations of these analytes could be important in developing embryos and newly hatched chicks to cope with stress attributed to auditory stimulation.
    Matched MeSH terms: Noise/adverse effects
  8. Kamaruddin NH, Bakar AAA, Mobarak NN, Zan MSD, Arsad N
    Sensors (Basel), 2017 Oct 06;17(10).
    PMID: 28984826 DOI: 10.3390/s17102277
    The study of binding affinity is essential in surface plasmon resonance (SPR) sensing because it allows researchers to quantify the affinity between the analyte and immobilised ligands of an SPR sensor. In this study, we demonstrate the derivation of the binding affinity constant, K, for Pb2+and Hg2+ions according to their SPR response using a gold/silver/gold/chitosan-graphene oxide (Au/Ag/Au/CS-GO) sensor for the concentration range of 0.1-5 ppm. The higher affinity of Pb2+to binding with the CS-GO sensor explains the outstanding sensitivity of 2.05 °ppm-1against 1.66 °ppm-1of Hg2+. The maximum signal-to-noise ratio (SNR) upon detection of Pb2+is 1.53, and exceeds the suggested logical criterion of an SNR. The Au/Ag/Au/CS-GO SPR sensor also exhibits excellent repeatability in Pb2+due to the strong bond between its functional groups and this cation. The adsorption data of Pb2+and Hg2+on the CS-GO sensor fits well with the Langmuir isotherm model where the affinity constant, K, of Pb2+and Hg2+ions is computed. The affinity of Pb2+ions to the Au/Ag/Au/CS-GO sensor is significantly higher than that of Hg2+based on the value of K, 7 × 10⁵ M-1and 4 × 10⁵ M-1, respectively. The higher shift in SPR angles due to Pb2+and Hg2+compared to Cr3+, Cu2+and Zn2+ions also reveals the greater affinity of the CS-GO SPR sensor to them, thus supporting the rationale for obtaining K for these two heavy metals. This study provides a better understanding on the sensing performance of such sensors in detecting heavy metal ions.
    Matched MeSH terms: Signal-To-Noise Ratio
  9. Ishak WS, Zhao F, Rajenderkumar D, Arif M
    Int Tinnitus J, 2013;18(1):35-44.
    PMID: 24995898 DOI: 10.5935/0946-5448.20130006
    The general consensus on the roles of hearing loss in triggering tinnitus seems not applicable in patients with normal hearing thresholds. The absence of hearing loss on the audiogram in this group of patients poses a serious challenge to the cochlear theories in explaining tinnitus generation in this group of patients.
    Matched MeSH terms: Noise*
  10. Chow LS, Rajagopal H, Paramesran R, Alzheimer's Disease Neuroimaging Initiative
    Magn Reson Imaging, 2016 07;34(6):820-831.
    PMID: 26969762 DOI: 10.1016/j.mri.2016.03.006
    Medical Image Quality Assessment (IQA) plays an important role in assisting and evaluating the development of any new hardware, imaging sequences, pre-processing or post-processing algorithms. We have performed a quantitative analysis of the correlation between subjective and objective Full Reference - IQA (FR-IQA) on Magnetic Resonance (MR) images of the human brain, spine, knee and abdomen. We have created a MR image database that consists of 25 original reference images and 750 distorted images. The reference images were distorted with six types of distortions: Rician Noise, Gaussian White Noise, Gaussian Blur, DCT compression, JPEG compression and JPEG2000 compression, at various levels of distortion. Twenty eight subjects were chosen to evaluate the images resulting in a total of 21,700 human evaluations. The raw scores were then converted to Difference Mean Opinion Score (DMOS). Thirteen objective FR-IQA metrics were used to determine the validity of the subjective DMOS. The results indicate a high correlation between the subjective and objective assessment of the MR images. The Noise Quality Measurement (NQM) has the highest correlation with DMOS, where the mean Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are 0.936 and 0.938 respectively. The Universal Quality Index (UQI) has the lowest correlation with DMOS, where the mean PLCC and SROCC are 0.807 and 0.815 respectively. Student's T-test was used to find the difference in performance of FR-IQA across different types of distortion. The superior IQAs tested statistically are UQI for Rician noise images, Visual Information Fidelity (VIF) for Gaussian blur images, NQM for both DCT and JPEG compressed images, Peak Signal-to-Noise Ratio (PSNR) for JPEG2000 compressed images.
    Matched MeSH terms: Signal-To-Noise Ratio
  11. Rahma MS, Mustafa BE, Razali A, Shamsuddin N, Althunibat OY
    Noise Health, 2013 Nov-Dec;15(67):375-8.
    PMID: 24231415 DOI: 10.4103/1463-1741.121223
    Several epidemiologic studies have reported that exposure to noise is associated with cardiovascular disease. The increased body weight is often associated with metabolic as well as increased blood pressure. The aim of this study is to investigate the correlation between the elevation of blood pressure and serum leptin hormones due to the effects of noise in the work place. A total of 80 volunteer males where included in this study with an age range between of 20 and 45 years, they were divided in two groups equally, the 1 st group were exposed to noise in the workplace while the 2 nd group were not. The individual noise exposure was determined by using a sound level meter. The range of noise was 80-100 dBA. Body Mass Index was also taken for each individual by a standard measure, blood pressure was measured by OMRON sphygmomanometer and serum leptin was measured through venous blood sample analysis enzyme linked immunosorbent assay. Spearman rank order correlation was used to examine the correlations between Blood pressure value (Systolic, Diastolic) and Leptin. All the relationships between parameters showed a positive correlation. Systolic and diastolic blood pressure values had a significant correlation to leptin hormone level in comparison to the control. There was a significant relation between leptin and blood pressure. leptin effects on the sympathetic nervous system may provide a partial explanation. Therefore, Leptin might have diverse cardiovascular actions.
    Matched MeSH terms: Noise, Occupational/adverse effects*
  12. Yahaya Rashid AS, Ramli R, Mohamed Haris S, Alias A
    ScientificWorldJournal, 2014;2014:190214.
    PMID: 25101312 DOI: 10.1155/2014/190214
    The dynamic behavior of a body-in-white (BIW) structure has significant influence on the noise, vibration, and harshness (NVH) and crashworthiness of a car. Therefore, by improving the dynamic characteristics of BIW, problems and failures associated with resonance and fatigue can be prevented. The design objectives attempt to improve the existing torsion and bending modes by using structural optimization subjected to dynamic load without compromising other factors such as mass and stiffness of the structure. The natural frequency of the design was modified by identifying and reinforcing the structure at critical locations. These crucial points are first identified by topology optimization using mass and natural frequencies as the design variables. The individual components obtained from the analysis go through a size optimization step to find their target thickness of the structure. The thickness of affected regions of the components will be modified according to the analysis. The results of both optimization steps suggest several design modifications to achieve the target vibration specifications without compromising the stiffness of the structure. A method of combining both optimization approaches is proposed to improve the design modification process.
    Matched MeSH terms: Noise*
  13. Mohamed Moubark A, Ali SH
    ScientificWorldJournal, 2014;2014:107831.
    PMID: 25197687 DOI: 10.1155/2014/107831
    This paper presents a new practical QPSK receiver that uses digitized samples of incoming QPSK analog signal to determine the phase of the QPSK symbol. The proposed technique is more robust to phase noise and consumes up to 89.6% less power for signal detection in demodulation operation. On the contrary, the conventional QPSK demodulation process where it uses coherent detection technique requires the exact incoming signal frequency; thus, any variation in the frequency of the local oscillator or incoming signal will cause phase noise. A software simulation of the proposed design was successfully carried out using MATLAB Simulink software platform. In the conventional system, at least 10 dB signal to noise ratio (SNR) is required to achieve the bit error rate (BER) of 10(-6), whereas, in the proposed technique, the same BER value can be achieved with only 5 dB SNR. Since some of the power consuming elements such as voltage control oscillator (VCO), mixer, and low pass filter (LPF) are no longer needed, the proposed QPSK demodulator will consume almost 68.8% to 99.6% less operational power compared to conventional QPSK demodulator.
    Matched MeSH terms: Signal-To-Noise Ratio
  14. Azman KF, Zakaria R, AbdAziz C, Othman Z, Al-Rahbi B
    Noise Health, 2015 Mar-Apr;17(75):83-9.
    PMID: 25774610 DOI: 10.4103/1463-1741.153388
    Recent evidence has exhibited dietary influence on the manifestation of different types of behavior induced by stressor tasks. The present study examined the effects of Tualang honey supplement administered with the goal of preventing or attenuating the occurrence of stress-related behaviors in male rats subjected to noise stress. Forty-eight adult male rats were randomly divided into the following four groups: i) nonstressed with vehicle, ii) nonstressed with Tualang honey, iii) stressed with vehicle, and iv) stressed with honey. The supplement was given once daily via oral gavage at 0.2 g/kg body weight. Two types of behavioral tests were performed, namely, the novel object recognition test to evaluate working memory and the forced swimming test to evaluate depressive-like behavior. Data were analyzed by a two-way analysis of variance (ANOVA) using IBM SPSS 18.0. It was observed that the rats subjected to noise stress expressed higher levels of depressive-like behavior and lower memory functions compared to the unexposed control rats. In addition, our results indicated that the supplementation regimen successfully counteracted the effects of noise stress. The forced swimming test indicated that climbing and swimming times were significantly increased and immobility times significantly decreased in honey-supplemented rats, thereby demonstrating an antidepressant-like effect. Furthermore, cognitive function was shown to be intensely affected by noise stress, but the effects were counteracted by the honey supplement. These findings suggest that subchronic exposure to noise stress induces depressive-like behavior and reduces cognitive functions, and that these effects can be attenuated by Tualang honey supplementation. This warrants further studies to examine the role of Tulang honey in mediating such effects.
    Matched MeSH terms: Noise*
  15. Abass AK, Al-Mansoori MH, Jamaludin MZ, Abdullah F, Al-Mashhadani TF
    Appl Opt, 2013 Jun 1;52(16):3764-9.
    PMID: 23736332 DOI: 10.1364/AO.52.003764
    We experimentally investigate the performance of L-band multiwavelength Brillouin-Raman fiber laser (MBRFL) under forward and backward pumped environments utilizing a linear cavity. A short length of 1.18 km dispersion compensating fiber is used as a nonlinear gain medium for both Brillouin and Raman gain. Experimental results indicate that the gain in the copumped laser configuration is higher than the gain in the counterpumped configuration. A stable and constant number of Brillouin Stokes lines up to 23 Stokes, with channel spacing of 0.08 nm and more than 20 dB of optical signal to noise ratio, can be generated as well as tuning over 20 nm in the L-band region from 1570 to 1590 nm. The laser generating the Brillouin Stokes lines exhibits flat amplitude bandwidth and high average output power of 0.8 and 1.6 dBm for the copropagation and counterpropagation pumps, respectively. Moreover, the tuning range bandwidth of the MBRFL can be predicted from the oscillated Brillouin pump gain profile.
    Matched MeSH terms: Signal-To-Noise Ratio
  16. Usmani S, Rasheed R, Al Kandari F
    J Nucl Med Technol, 2020 Jun;48(2):181-183.
    PMID: 32111663 DOI: 10.2967/jnmt.119.235986
    Textitis is a new term used to refer to the degenerative-strain osteoarthritis that comes from excessive use of a smart phone. 18F-NaF is increasingly used in diagnosing skeletal pain that is not identified on radiographs. We report a case of a 26-y-old woman with left breast cancer referred for 18F-NaF PET/CT, who was complaining of right thumb and wrist pain. Findings were negative for bone secondaries. Dedicated hands views were acquired on a positron emission mammography scanner and showed focal uptake at the first carpometacarpal and second metacarpophalangeal joints. On the basis of the strong history, the findings were likely due to active arthritic changes caused by repetitive strain injury from excessive text messaging.
    Matched MeSH terms: Signal-To-Noise Ratio*
  17. Ng, Sok Bee, Ahmad Nazlim Yusoff, Teng, Xin Ling, Aini Ismafairus Abd. Hamid
    MyJurnal
    Knowledge about the hemodynamic model that mediates synaptic activity and measured magnetic resonance signal is essential in understanding brain activation. Neural efficacy is a hemodynamic parameter that would change the evoked hemodynamic responses. In this work, brain activation and neural efficacy of the activated brain areas during simple addition task in two different backgrounds were studied using fMRI. The objectives were to determine the activated areas during the performance of arithmetic addition in quiet (AIQ) and noisy (AIN) background and to investigate the relationship between neural efficacy and height extent of activation for the respective areas. Eighteen healthy male participants performed simple arithmetic addition in quiet and in noise. Bilateral cerebellum, superior temporal gyrus (STG), temporal pole (TP) and supplementary motor area (SMA) were significantly (p < 0.05) activated during AIQ and AIN. Left middle frontal gyrus (L-MFG), right superior frontal gyrus (R-SFG), right superior orbital gyrus (R-SOG) and bilateral insula were more active in quiet as compared to in noise while the left middle cingulate cortex (L-MCC), left amygdala (L-AMG), right temporal pole (R-TP) and left cerebellum (L-CER) were more active in noise as compared to in quiet. The t value for most of the activated regions was found to be inversely proportional to the neural efficacy. Significant (p < 0.05) negative relationship between t value and neural efficacy were found for R-STG and bilateral cerebellum during AIQ, while for AIN, similar relationships were found in R-CER, R-STG and R-TP. This study suggests that while being significantly activated, the hemodynamic responses of these brain regions could have been suppressed by the stimulus resulting in an intensity decrease with increasing neural efficacy.
    Matched MeSH terms: Noise
  18. Harun, S.W., Sulaiman, A.H., Ahmad, H.
    ASM Science Journal, 2009;3(1):27-30.
    MyJurnal
    We demonstrate a multi-wavelength light source using a semiconductor optical amplifier (SOA) in conjunction with an array waveguide grating (AWG). The experimental results showed more than 20 channels with a wavelength separation of 0.8 nm and an optical signal-to-noise ratio of more than 10 dB under room temperature. The channels operated at the wavelength region from 1530.4 nm to 1548.6 nm, which corresponded to AWG filtering wavelengths with SOA drive current of 350 mA. The proposed light source had the advantages of a simple and compact structure, multi-wavelength operation and the system could be upgraded to generate more wavelengths.
    Matched MeSH terms: Signal-To-Noise Ratio
  19. Harun, S.W., Tamjis, M.R., Muhd-Yassin, S.Z., Abd-Rahman, M.K., Ahmad, H.
    ASM Science Journal, 2007;1(2):129-133.
    MyJurnal
    This paper demonstrates an erbium/ytterbium co-doped fi bre amplifi er (EYDFA) which used a pumping wavelength of 1058 nm, whereby the amplifi cation was assisted by the energy transfer between Yb and Er ions. The energy transfer increased the erbium doping concentration limit that was imposed by concentration quenching in erbium-doped fi bre. The optimum length was obtained at 4m~6m for erbium/ytterbium co-doped fi bre with Er ion concentration of 1000 p.p.m. This enabled the development of a compact amplifi er with a shorter gain medium compared to erbium-doped fi bre amplifi ers which use a gain medium of up to 15 m. A 1058 nm pumping wave-length was used for the EYDFA, as 1480 nm pumping resulted in severely degraded gain and noise fi gures because the energy transfer could not be achieved. The use of the optical isolator improved the small signal gain and noise fi gure by about 4.8 dB and 1.6 dB, respectively. Without the isolator, gain saturation and a noise fi gure penalty were observed due to the oscillating laser which was created at around 1534 nm by spurious refl ection. This showed that the usage of optical isolators was an important aspect to consider when designing an EYDFA.
    Matched MeSH terms: Noise
  20. Ahmad Syazrin Muhamad
    MyJurnal
    Sound is one of the source of energy generated by vibration and is carried through the air in a form of pressure waves (Frederick, 1975). This pressure waves consist of pulsation or vibration of molecules of an elastic medium such as gas, liquid and even solid (Gerber, 1974). Due to its nature, sound can be irritating when it is excessive. The excessive amount of sound is called noise. Exposure to noise is common to the workers working at the industry. This can lead to hearing loss. Hearing loss is one of the most common health problems in the industrialized world. Working activities have been related to noise exposure due to increase use of machine that generates sounds. Many workers throughout the world experience hazardous noise exposure which is ≥ 85 decibels (dB) (Seter, 1998). Based on the previous study in the European region, most of the employers had difficulties to compensate workers diagnosed with hearing loss or hearing impairment cause by the working nature. (Rachiotis et al., 2006). According to European Survey on Working Conditions, about 7% of the workers considered that their work affects their health in the form of hearing disorders. Occupational risk factors for hearing loss include occupational noise, whole body vibration, work-related diseases and exposure to chemical. In this report, we specified in the noise exposure level of the workers.
    Matched MeSH terms: Noise, Occupational
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links