Displaying all 15 publications

Abstract:
Sort:
  1. Abdul Razak, K., Mariam, A., Amirin, S., Mohd Zaini, A.
    MyJurnal
    Introduction: The study was done at the aim to assess the functionality and viability of the β cells of the streptozotocin-induced diabetic rats model following repetitive dosage of administration of ethanolic extracts of Andrographis paniculata. Materials and Methods: The diabetic rats were treated with the extracts for fourteen days and at the dose given was 500 mg/kg twice daily. The assessments were made on fasting blood glucose, insulin, and immunohistochemical aspect of β cells before and after treatment. Results: The results showed that there was a signifi cant reduction on fasting blood glucose levels in metformin, 95% and 50% ethanolic plant extracts-treated groups but on insulin level only 95% and 50% ethanolic extracts-treated groups gave a signifi cant reduction(p
  2. Ridhuan NS, Abdul Razak K, Lockman Z
    Sci Rep, 2018 09 13;8(1):13722.
    PMID: 30213995 DOI: 10.1038/s41598-018-32127-5
    Highly oriented ZnO nanorod (NR) arrays were fabricated on a seeded substrate through a hydrothermal route. The prepared ZnO nanorods were used as an amperometric enzyme electrode, in which glucose oxidase (GOx) was immobilised through physical adsorption. The modified electrode was designated as Nafion/GOx/ZnO NRs/ITO. The morphology and structural properties of the fabricated ZnO nanorods were analysed using field-emission scanning electron microscope and X-ray diffractometer. The electrochemical properties of the fabricated biosensor were studied by cyclic voltammetry and amperometry. Electrolyte pH, electrolyte temperature and enzyme concentration used for immobilisation were the examined parameters influencing enzyme activity and biosensor performance. The immobilised enzyme electrode showed good GOx retention activity. The amount of electroactive GOx was 7.82 × 10-8 mol/cm2, which was relatively higher than previously reported values. The Nafion/GOx/ZnO NRs/ITO electrode also displayed a linear response to glucose ranging from 0.05 mM to 1 mM, with a sensitivity of 48.75 µA/mM and a low Michaelis-Menten constant of 0.34 mM. Thus, the modified electrode can be used as a highly sensitive third-generation glucose biosensor with high resistance against interfering species, such as ascorbic acid, uric acid and L-cysteine. The applicability of the modified electrode was tested using human blood samples. Results were comparable with those obtained using a standard glucometer, indicating the excellent performance of the modified electrode.
  3. Makhadmeh GN, Abdul Aziz A, Abdul Razak K
    Artif Cells Nanomed Biotechnol, 2016 May;44(3):1018-22.
    PMID: 25707443 DOI: 10.3109/21691401.2015.1008511
    This study analyzed the physical effects of methylene blue (MB) encapsulated within silica nanoparticles (SiNPs) in photodynamic therapy.
  4. Makhadmeh GN, Abdul Aziz A, Abdul Razak K
    Artif Cells Nanomed Biotechnol, 2016 Aug;44(5):1285-9.
    PMID: 25811998 DOI: 10.3109/21691401.2015.1024843
    The synthesis of methylene blue (MB) encapsulated in silica nanoparticles (SiNPs) as an application for photodynamic therapy is reported in this study. Semi-rigid tissues with optical properties similar to that of human tissues were used as sample materials to determine the applicability of MB encapsulated in SiNPs.
  5. Yahaya ML, Zakaria ND, Noordin R, Abdul Razak K
    Biotechnol Appl Biochem, 2021 Oct;68(5):1095-1106.
    PMID: 32935878 DOI: 10.1002/bab.2029
    Salmonella and Shigella genera are common pathogens that contaminate foods and beverages. Lateral flow assays (LFA) are commonly used to detect these pathogens. However, most of the developed LFAs are for single detection. Simultaneous detection of pathogens is required to reduce cost and time. In this work, 40 nm gold nanoparticles (AuNPs) were synthesized using the seeding growth method as labeling agent. The AuNPs were characterized and conjugated with mouse anti-Gram negative endotoxin antibody. The nitrocellulose membrane HF135 was immobilized with anti-mouse IgG antibody as a control line and two separate test lines with either anti-Shigella or anti-Salmonella antibody, respectively. Color intensity of test lines was observed for positive samples. A milk sample was used as proof of concept to mimic actual contamination. The limit of detection of the LFA was 3.0 × 106 CFU/mL for multiplex detection of Shigella flexneri and Salmonella Typhi and for both single detections. The result was comparable with the enzyme-linked immunosorbent assay (ELISA) analysis. The produced LFA could differentiate between Shigella flexneri, Shigella boydii, Salmonella Enteritidis, and Salmonella Typhi. The developed LFA was able to identify Shigella flexneri and Salmonella Typhi with good sensitivity in milk samples, thus, beneficial to ensure the safety of food before entering the market.
  6. Mohamad Nor N, Ridhuan NS, Abdul Razak K
    Biosensors (Basel), 2022 Dec 06;12(12).
    PMID: 36551103 DOI: 10.3390/bios12121136
    This review covers the progress of nanomaterial-modified electrodes for enzymatic and non-enzymatic glucose biosensors. Fundamental insights into glucose biosensor components and the crucial factors controlling the electrochemical performance of glucose biosensors are discussed in detail. The metal, metal oxide, and hybrid/composite nanomaterial fabrication strategies for the modification of electrodes, mechanism of detection, and significance of the nanomaterials toward the electrochemical performance of enzymatic and non-enzymatic glucose biosensors are compared and comprehensively reviewed. This review aims to provide readers with an overview and underlying concept of producing a reliable, stable, cost-effective, and excellent electrochemical performance of a glucose biosensor.
  7. Mohamad Nor N, Nasrul SN, Zakaria ND, Abdul Razak K
    ACS Omega, 2023 May 16;8(19):16587-16599.
    PMID: 37214679 DOI: 10.1021/acsomega.2c07085
    In this work, indium tin oxide (ITO) electrodes were functionalized with varying 3-aminopropyltriethoxysilane (APTES) concentration percentages (0.5, 0.75, 1.0, and 2.0 wt %) to obtain the optimum conditions for the assembly of the as-synthesized gold nanoparticles (AuNPs). The AuNP coverage, wettability, and electrochemical performance of the modified electrodes were evaluated. The AuNP/0.75% APTES-ITO-modified electrode exhibited uniform coverage of AuNPs and high electrochemical performance for the simultaneous detection of Cd(II), Pb(II), and Cu(II) ions. Under the optimum conditions, the AuNP/0.75% APTES-ITO-modified electrode showed a linear detection range of 5-120 ppb and limit of detection of 0.73, 0.90, and 0.49 ppb for the simultaneous detection of Cd(II), Pb(II), and Cu(II) ions, respectively, via square wave anodic stripping voltammetry. The modified electrode demonstrated good anti-interference toward other heavy metal ions, good reproducibility, and suitability for application in environmental sample analysis.
  8. Makhadmeh GN, Abdul Aziz A, Abdul Razak K, Abu Noqta O
    IET Nanobiotechnol, 2015 Dec;9(6):381-5.
    PMID: 26647815 DOI: 10.1049/iet-nbt.2015.0003
    This study analysed the physical effects of Cichorium Pumilum (CP), as a natural photosensitizer (PS), and Protoporphyrin IX (PpIX), as a synthetic PS, encapsulated with silica nanoparticles (SiNPs) in photodynamic therapy. The optimum concentrations of CP and PpIX, needed to destroy Red Blood Cells (RBC), were determined and the efficacy of encapsulated CP and PpIX were compared with naked CP and PpIX was verified. The results confirmed the applicability of CP and PpIX encapsulated in SiNPs on RBCs, and established a relationship between the encapsulated CP and PpIX concentration and the time required to rupture 50% of the RBCs (t50). The CP and PpIX encapsulated in SiNPs exhibited higher efficacy compared with that of naked CP and PpIX, respectively, and CP had less efficacy compared with PpIX.
  9. Mohamed MI, Mohammad MK, Abdul Razak HR, Abdul Razak K, Saad WM
    Biomed Res Int, 2015;2015:183525.
    PMID: 26075217 DOI: 10.1155/2015/183525
    Emerging syntheses and findings of new metallic nanoparticles (MNPs) have become an important aspect in various fields including diagnostic imaging. To date, iodine has been utilized as a radiographic contrast medium. However, the raise concern of iodine threats on iodine-intolerance patient has led to search of new contrast media with lower toxic level. In this animal modeling study, 14 nm iron oxide nanoparticles (IONPs) with silane-polyethylene glycol (SiPEG) and perchloric acid have been assessed for toxicity level as compared to conventional iodine. The nanotoxicity of IONPs was evaluated in liver biochemistry, reactive oxygen species production (ROS), lipid peroxidation mechanism, and ultrastructural evaluation using transmission electron microscope (TEM). The hematological analysis and liver function test (LFT) revealed that most of the liver enzymes were significantly higher in iodine-administered group as compared to those in normal and IONPs groups (P < 0.05). ROS production assay and lipid peroxidation indicator, malondialdehyde (MDA), also showed significant reductions in comparison with iodine group (P < 0.05). TEM evaluation yielded the aberration of nucleus structure of iodine-administered group as compared to those in control and IONPs groups. This study has demonstrated the less toxic properties of IONPs and it may postulate that IONPs are safe to be applied as radiographic contrast medium.
  10. Zakaria ND, Omar MH, Ahmad Kamal NN, Abdul Razak K, Sönmez T, Balakrishnan V, et al.
    ACS Omega, 2021 Sep 28;6(38):24419-24431.
    PMID: 34604624 DOI: 10.1021/acsomega.1c02670
    Electrodeposition is an electrochemical method employed to deposit stable and robust gold nanoparticles (AuNPs) on electrode surfaces for creating chemically modified electrodes (CMEs). The use of several electrodeposition techniques with different experimental parameters allow in obtaining various surface morphologies of AuNPs deposited on the electrode surface. By considering the electrodeposition of AuNPs in various background electrolytes could play an important strategy in finding the most suitable formation of the electrodeposited AuNP films on the electrode surface. This is because different electrode roughnesses can have different effects on the electrochemical activities of the modified electrodes. Thus, in this study, the electrodeposition of AuNPs onto the glassy carbon (GC) electrode surfaces in various aqueous neutral and acidic electrolytes was achieved by using the cyclic voltammetry (CV) technique with no adjustable CV parameters. Then, surface morphologies and electrochemical activities of the electrodeposited AuNPs were investigated using scanning electron microscopy (SEM), atomic force microscopy (AFM), CV, and electrochemical impedance spectroscopy (EIS). The obtained SEM and 3D-AFM images show that AuNPs deposited at the GC electrode prepared in NaNO3 solution form a significantly better, uniform, and homogeneous electrodeposited AuNP film on the GC electrode surface with nanoparticle sizes ranging from ∼36 to 60 nm. Meanwhile, from the electrochemical performances of the AuNP-modified GC electrodes, characterized by using a mixture of ferricyanide and ferrocyanide ions [Fe(CN6)3-/4-], there is no significant difference observed in the case of charge-transfer resistances (R ct) and heterogeneous electron-transfer rate constants (k o), although there are differences in the surface morphologies of the electrodeposited AuNP films. Remarkably, the R ct values of the AuNP-modified GC electrodes are lower than those of the bare GC electrode by 18-fold, as the R ct values were found to be ∼6 Ω (p < 0.001, n = 3). This has resulted in obtaining k o values of AuNP-modified GC electrodes between the magnitude of 10-2 and 10-3 cm s-1, giving a faster electron-transfer rate than that of the bare GC electrode (10-4 cm s-1). This study confirms that using an appropriate supporting background electrolyte plays a critical role in preparing electrodeposited AuNP films. This approach could lead to nanostructures with a more densely, uniformly, and homogeneously electrodeposited AuNP film on the electrode surfaces, albeit utilizing an easy and simple preparation method.
  11. Budiman F, Tan WK, Kawamura G, Muto H, Matsuda A, Abdul Razak K, et al.
    ACS Omega, 2021 Oct 26;6(42):28203-28214.
    PMID: 34723018 DOI: 10.1021/acsomega.1c04280
    Coral-like and nanowire (NW) iron oxide nanostructures were produced at 700 and 800 °C, respectively, through thermal oxidation of iron foils in air- and water vapor-assisted conditions. Water vapor-assisted thermal oxidation at 800 °C for 2 h resulted in the formation of highly crystalline α-Fe2O3 NWs with good foil surface coverage, and we propose that their formation was due to a stress-driven surface diffusion mechanism. The Cr(VI) adsorption property of an aqueous solution on α-Fe2O3 NWs was also evaluated after a contact time of 90 min. The NWs had a removal efficiency of 97% in a 225 mg/L Cr(VI) solution (pH 2, 25 °C). The kinetic characteristic of the adsorption was fitted to a pseudo-second-order kinetic model, and isothermal studies indicated that the α-Fe2O3 NWs exhibited an adsorption capacity of 66.26 mg/g. We also investigated and postulated a mechanism of the Cr(VI) adsorption in an aqueous solution of α-Fe2O3 NWs.
  12. Mohamad Nor N, Arivalakan S, Zakaria ND, Nilamani N, Lockman Z, Abdul Razak K
    ACS Omega, 2022 Feb 01;7(4):3823-3833.
    PMID: 35128290 DOI: 10.1021/acsomega.1c07158
    Carboxyl (-COOH)-stabilized iron oxide nanoparticles (IONPs) synthesized through co-precipitation were used to modify an indium tin oxide (ITO) electrode, which was chemically functionalized with 3-aminopropyltriethoxysilane (APTES) for heavy metal detection. The effect of soaking time (30, 60, 90, and 120 min) of IONP-COOH self-assembled on an APTES-ITO electrode was studied. Cyclic voltammetry and scanning electron microscopy were applied to analyze the electrochemical properties and morphologies of IONP-COOH/APTES-ITO modified electrode. The modified electrodes were then employed for the simultaneous detection of Cd(II) and Pb(II) by using square wave anodic stripping voltammetry. At 90 min of soaking time, excellent electrochemical performance and larger effective surface area (A e) were obtained. The linear range for the simultaneous detection of Cd(II) and Pb(II) ions using the modified electrode was 10-100 ppb with limits of detection of 0.90 and 0.60 ppb, respectively. The interference study revealed a low interference effect from Cr(III), Hg(II), Zn(II), Cu(II), Mg(II), Na(I), and K(I) toward the simultaneous detection of Cd(II) and Pb(II). Finally, the IONP-COOH/APTES-ITO-modified electrode was applied to analyze seawater samples and was able to simultaneously detect Cd(II) and Pb(II) ions.
  13. Mohamad Nor N, Ramli NH, Poobalan H, Qi Tan K, Abdul Razak K
    Crit Rev Anal Chem, 2023;53(2):253-288.
    PMID: 34565248 DOI: 10.1080/10408347.2021.1950521
    Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.
  14. Talik Sisin NN, Abdul Razak K, Zainal Abidin S, Che Mat NF, Abdullah R, Ab Rashid R, et al.
    Int J Nanomedicine, 2020;15:7805-7823.
    PMID: 33116502 DOI: 10.2147/IJN.S269214
    Purpose: This study aimed to quantify synergetic effects induced by bismuth oxide nanoparticles (BiONPs), cisplatin (Cis) and baicalein-rich fraction (BRF) natural-based agent on the reactive oxygen species (ROS) generation and radiosensitization effects under irradiation of clinical radiotherapy beams of photon, electron and HDR-brachytherapy. The combined therapeutic responses of each compound and clinical radiotherapy beam were evaluated on breast cancer and normal fibroblast cell line.

    Methods: In this study, individual BiONPs, Cis, and BRF, as well as combinations of BiONPs-Cis (BC), BiONPs-BRF (BB) and BiONPs-Cis-BRF (BCB) were treated to the cells before irradiation using HDR brachytherapy with 0.38 MeV iridium-192 source, 6 MV photon beam and 6 MeV electron beam. The individual or synergetic effects from the application of the treatment components during the radiotherapy were elucidated by quantifying the ROS generation and radiosensitization effects on MCF-7 and MDA-MB-231 breast cancer cell lines as well as NIH/3T3 normal cell line.

    Results: The ROS generated in the presence of Cis stimulated the most substantial amount of ROS compared to the BiONPs and BRF. Meanwhile, the combination of the components had induced the higher ROS levels for photon beam than the brachytherapy and electron beam. The highest ROS enhancement relative to the control is attributable to the presence of BC combination in MDA-MB-231 cells, in comparison to the BB and BCB combinations. The radiosensitization effects which were quantified using the sensitization enhancement ratio (SER) indicate the highest value by BC in MCF-7 cells, followed by BCB and BB treatment. The radiosensitization effects are found to be more prominent for brachytherapy in comparison to photon and electron beam.

    Conclusion: The BiONPs, Cis and BRF are the potential radiosensitizers that could improve the efficiency of radiotherapy to eradicate the cancer cells. The combination of these potent radiosensitizers might produce multiple effects when applied in radiotherapy. The BC combination is found to have the highest SER, followed by the BCB combination. This study is also the first to investigate the effect of BRF in combination with BiONPs (BB) and BC (BCB) treatments.

  15. Sisin NNT, Abdul Razak K, Zainal Abidin S, Che Mat NF, Abdullah R, Ab Rashid R, et al.
    Int J Nanomedicine, 2019;14:9941-9954.
    PMID: 31908451 DOI: 10.2147/IJN.S228919
    Purpose: The aim of this study was to investigate the potential of the synergetic triple therapeutic combination encompassing bismuth oxide nanoparticles (BiONPs), cisplatin (Cis), and high dose rate (HDR) brachytherapy with Ir-192 source in breast cancer and normal fibroblast cell line.

    Methods: In vitro models of breast cancer cell lines (MCF-7, MDA-MB-231) and normal fibroblast cell line (NIH/3T3) were employed. Cellular localization and cytotoxicity studies were conducted prior to inspection on the radiosensitization effects and generation of reactive oxygen species (ROS) on three proposed radiosensitizers: BiONPs, Cis, and BiONPs-Cis combination (BC). The optimal, non-cytotoxic concentration of BiONPs (0.5 mM) and the 25% inhibitory concentration of Cis (1.30 µM) were applied. The radiosensitization effects were evaluated by using a 0.38 MeV Iridium-192 HDR brachytherapy source over a prescribed dose range of 0 Gy to 4 Gy.

    Results: The cellular localization of BiONPs was visualized by light microscopy and accumulation of the BiONPs within the vicinity of the nuclear membrane was observed. Quantification of the sensitization enhancement ratio extrapolated from the survival curves indicates radiosensitization effects for MCF-7 and MDA-MB-231 when treated with BiONPs, Cis, and BC. However, NIH/3T3 cells exhibited contradictive behavior as it only reacted towards the BC combination. Nonetheless, the MCF-7 cell line loaded with BC shows the highest SER of 4.29. ROS production analysis, on the other hand, shows that Cis and BC radiosensitizers generated the highest free radicals in comparison to BiONPs alone.

    Conclusion: A BiONPs-Cis combination was unveiled as a novel approach that offers promising radiosensitization enhancement that will increase the efficiency of tumor control while preserving the normal tissue at a reduced dose. This data is the first precedent to prove the synergetic implication of BiONPs, Cis, and HDR brachytherapy that will be beneficial for future chemoradiotherapy strategies in cancer care.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links