MATERIAL AND METHODS: A total of 66 adult patients underwent elective surgery under general anaes-thesia, and they were randomized to two groups: the Air-Q (AQ) group (n = 33) and the Ambu AuraGain (AA) group (n = 33). A simulated cervical spine injury was created using a cervical collar, which was applied after the induction of general anaesthesia. Ease of insertion, time taken for successful insertion, time taken for successful FO guided endotracheal intubation, oropharyngeal leak pressure (OLP), Brimacombe score for FO laryngeal view, post-intubation complications and haemodynamic changes were recorded for both groups.
RESULTS: The OLP was significantly higher in the AA group than in the AQ group (34.9 ± 6.4 vs. 28.6 ± 7.8 cm H 2 O; P = 0.001). Otherwise, there were no significant differences in the ease of insertion, time taken for successful insertion, time taken for successful FO guided endotracheal intubation, Brimacombe score for FO laryngeal view, haemodynamic parameters or complication rate between the two groups.
CONCLUSIONS: Air-Q was comparably effective as Ambu AuraGain as a conduit for FO endotracheal intubation in patients with a simulated cervical spine injury; however, Ambu AuraGain has a better seal with significant OLP.
METHODS: The study looked at the thermoluminescence dosimeters (TLDs) records of 50 medical professionals who were exposed to radiation while working at KFMC from 2019 to 2020 in Taif city, Saudi Arabia. In Riyadh, radiation exposure is read from skin TLDs using Harshaw model 6600 plus detectors. The Excel software was utilized to process the obtained data for calculating effective doses. A questionnaire was also distributed to the medical staff to assess their radiation protection procedures. The Statistical Package for Social Sciences (SPSS) program version 23 was used to analyze the obtained data.
RESULTS: The mean annual effective doses of the medical staff in 2019 and 2020 were determined to be 1.14 mSv and 1.4645 mSv, respectively, with no significant difference in effective doses between males and females in either year. The socio-demographic features of the medical personnel were examined, and the findings revealed that the majority of participants were male radiological technologists. The rate of adherence to radiation protection techniques was 68%, with a normally distributed dispersal. The amount of adherence varied significantly depending on nationality, occupation, and academic qualification.
CONCLUSION: According to the research, the mean annual effective dosage for medical professionals at KFMC was significantly below the recommended level, indicating satisfactory compliance with the ALARA radiation safety concept.