Displaying all 20 publications

Abstract:
Sort:
  1. Noor MA
    Injury, 1988 Nov;19(6):377-8.
    PMID: 3267638
    A simple and inexpensive external fixator has been designed. It is constructed of galvanized iron pipe and mild steel bolts and nuts. It can easily be manufactured in a hospital workshop with a minimum of tools.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  2. Mirzasadeghi A, Narayanan SS, Ng MH, Sanaei R, Cheng CH, Bajuri MY, et al.
    Biomed Mater Eng, 2014;24(6):2177-86.
    PMID: 25226916 DOI: 10.3233/BME-141029
    The application of bone substitutes and cements has a long standing history in augmenting fractures as a complement to routine fracture fixation techniques. Nevertheless, such use is almost always in conjunction with definite means of fracture fixation such as intramedullary pins or bone plates. The idea of using biomaterials as the primary fixation bears the possibility of simultaneous fixation and bone enhancement. Intramedullary recruitment of bone cements is suggested in this study to achieve this goal. However, as the method needs primary testings in animal models before human implementation, and since the degree of ambulation is not predictable in animals, this pilot study only evaluates the outcomes regarding the feasibility and safety of this method in the presence of primary bone fixators. A number of two sheep were used in this study. Tibial transverse osteotomies were performed in both animals followed by external skeletal fixation. The medullary canals, which have already been prepared by removing the marrow through proximal and distal drill holes, were then injected with calcium phosphate cement (CPC). The outcomes were evaluated postoperatively by standard survey radiographs, morphology, histology and biomechanical testings. Healing processes appeared uncomplicated until week four where one bone fracture recurred due to external fixator failure. The results showed 56% and 48% cortical thickening, compared to the opposite site, in the fracture site and proximal and distal diaphyses respectively. This bone augmentative effect resulted in 264% increase in bending strength of the fracture site and 148% increase of the same value in the adjacent areas of diaphyses. In conclusion, IMCO, using CPC in tibia of sheep, is safe and biocompatible with bone physiology and healing. It possibly can carry the osteopromotive effect of the CPCs to provide a sustained source of bone augmentation throughout the diaphysis. Although the results must be considered preliminary, this method has possible advantages over conventional methods of bone fixation at least in bones with compromised quality (i.e. osteoporosis and bone cysts), where rigid metal implants may jeopardize eggshell cortices.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  3. Latifi MH, Ganthel K, Rukmanikanthan S, Mansor A, Kamarul T, Bilgen M
    Biomed Eng Online, 2012;11:23.
    PMID: 22545650 DOI: 10.1186/1475-925X-11-23
    Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractures in the subtrochancteric region has yet to be explored. Therefore, this comparative study was undertaken to demonstrate the merits of the LP implant in treating the subtrochancteric fracture by comparing its performance limits against those obtained with the more traditional implants; angle blade plate (ABP) and dynamic condylar screw plate (DCSP).
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  4. Afshar R, Fong TS, Latifi MH, Kanthan SR, Kamarul T
    J Hand Surg Eur Vol, 2012 Jun;37(5):396-401.
    PMID: 22019989 DOI: 10.1177/1753193411424557
    The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse midshaft osteotomies were created in 20 metacarpals harvested from three cadavers. Fractures were stabilised using 2.0 mm mini fragment plates fixed with either bicortical or unicortical screw fixation. These fixations were tested to failure with a three-point bending cyclic loading protocol using an electromechanical microtester and a 1 kN load cell. The mean load to failure was 370 N (SD 116) for unicortical fixation and 450 N (SD 135) for bicortical fixation. Significant differences between these two constructs were observed. A biomechanical advantage was found when using bicortical screws in metacarpal fracture plating.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  5. Abdul-Rahman MR, Seong NK, Hee TG, Aljada ME, Reda TA, Sumin JO, et al.
    Heart Surg Forum, 2009 Jun;12(3):E184-6.
    PMID: 19546075 DOI: 10.1532/HSF98.20091016
    Various techniques of sternal stabilization via either metal plates or wires have been described. We describe an alternative technique of simple median sternotomy followed by reduction and wire fixation of the sternal fracture. The 2 patients described in this report had traumatic comminuted and displaced sternal fractures. Even though wire repair was deemed to be tedious and achieved poor approximation of the bone, we performed median sternotomy and achieved simple wire fixation with an excellent result.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  6. Tan WJ, Kwan MK, Deepak AS, Saw A, Peng BC, Jalalullah W
    Med J Malaysia, 2006 Dec;61 Suppl B:18-22.
    PMID: 17600988
    Fracture of the femur is most commonly treated with interlocking nailing. We conducted this study to describe and analyze the size of femoral interlocking nails used in our local population. This is a retrospective study on reamed intramedullary interlocking nailing procedures performed between 1st July 1998 and 30th June 2003. Demographic data, the diameter and length of femoral nails used were obtained from patient's medical record. A total of 267 procedures were included. The most common diameter used was 10 mm (56.9%), followed by 11 mm (27.0%) and 12 mm (13.1%). Only 2.6% of the nails were less than 10 mm in diameter. The most common nail length was 38 cm (31.1%), followed by 36 cm (24.9%) and 40 cm (19.5%). The longest nail used was 46 cm while the shortest 32 cm. The most commonly used femoral nails were of 10 mm diameter with the length ranging from 36 to 40 cm, which is smaller than those reported in the English literature. Nails with diameter smaller than 10 mm were required in 2.6% of patients.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  7. Hussain PB, Mohammad M
    Med J Malaysia, 2004 May;59 Suppl B:180-1.
    PMID: 15468877
    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  8. Shanmugam R, Ernst M, Stoffel K, Fischer MF, Wahl D, Richards RG, et al.
    Clin Biomech (Bristol, Avon), 2015 Jun;30(5):405-10.
    PMID: 25846324 DOI: 10.1016/j.clinbiomech.2015.03.019
    Dorsal plating is commonly used in proximal phalanx fractures but it bears the risk of interfering with the extensor apparatus. In this study, dorsal and lateral plating fixation methods are compared to assess biomechanical differences using conventional 1.5mm non-locking plates and novel 1.3mm lateral locking plates.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  9. Gan JT, Chandrasekaran SK, Tuan Jusoh TB
    Acta Orthop Traumatol Turc, 2020 Sep;54(5):483-487.
    PMID: 33155556 DOI: 10.5152/j.aott.2020.19219
    OBJECTIVE: The aim of this study was to compare the clinical outcomes and operative cost of a locked compression plate (LCP) and a nonlocked reconstruction plate in the treatment of displaced midshaft clavicle fracture.

    METHODS: From January 2013 till March 2018, a total of 55 patients with acute unilateral closed midshaft clavicle fracture were treated with either a 3.5-mm pre-contoured LCP [32 patients; 25 men and 7 women; mean age: 35 years (range: 19-63 years)] or a 3.5-mm nonlocked reconstruction plate [23 patients; 20 men and 3 women; mean age: 31.4 years (range: 17-61 years)]. The clinical outcomes in terms of fracture union, Quick Disability of Arm, Shoulder and Hand (DASH) score, implant irritation, failure rate, and reoperation rate were evaluated retrospectively. The patient billing records were reviewed to obtain primary operation, reoperation, and total operative cost for midshaft clavicle fracture. These values were analyzed and converted from Malaysia Ringgit (RM) to United States Dollar (USD) at the exchange rate of RM 1 to USD 0.24. All patients were followed up for at least one-year duration.

    RESULTS: The mean time to fracture union, implant irritation, implant failure, and reoperation rate showed no significant difference between the two groups of patients. The mean Quick DASH score was significantly better in the reconstruction plate group with 13 points compared with 28 points in the LCP group (p=0.003). In terms of total operative cost, the LCP group recorded a cost of USD 391 higher than the reconstruction plate group (p<0.001).

    CONCLUSION: The 3.5-mm reconstruction plate achieved not only satisfactory clinical outcomes but was also more cost-effective than the LCP in the treatment of displaced midshaft clavicle fractures.

    LEVEL OF EVIDENCE: Level III, Therapeutic study.

    Matched MeSH terms: Fracture Fixation, Internal/instrumentation
  10. Shanmugam R, Jian CYCCS, Haseeb A, Aik S
    J Orthop Surg (Hong Kong), 2018 10 3;26(3):2309499018802511.
    PMID: 30270746 DOI: 10.1177/2309499018802511
    PURPOSE: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion.

    METHOD: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion.

    RESULTS: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group.

    CONCLUSION: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.

    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  11. Yusof MI, Ming LK, Abdullah MS
    J Orthop Surg (Hong Kong), 2007 Aug;15(2):187-90.
    PMID: 17709859
    To measure the cervical pedicles and assess the feasibility of transpedicular fixation in a Malay population.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  12. Ling HT, Kwan MK, Chua YP, Deepak AS, Ahmad TS
    Med J Malaysia, 2006 Dec;61 Suppl B:8-12.
    PMID: 17600986
    Treatment of radius or ulna nonunion requires both osteogenic environment and mechanical stability. We would like to report three radial and six ulnar diaphyseal nonunions treated with 3.5 mm locking compression plate (LCP) fixation. To assess the effectiveness of 3.5 mm LCP in treating diaphyseal nonunion of the forearm bones, we prospectively reviewed nine patients with the mean age of 33 years with diaphyseal nonunion of the radius or ulna. All patients were treated with 3.5 mm LCP. Bone grafting was only performed for atrophic nonunion. Surgical and functional outcome were evaluated. There were three atrophic nonunion of the radius, four atrophic nonunion of the ulna and two hypertrophic nonunion of the ulna. All nonunion united successfully with satisfactory functional outcome. 3.5 mm LCP is effective in the treatment of nonunion of ulna or radius.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  13. Ngeow WC, Lian CB
    Singapore Dent J, 1996 Jul;21(1):16-8.
    PMID: 10597177
    Fractures of the mandible and their management are discussed in detail in textbooks and articles dealing with facial trauma. This paper presents the management and treatment of a case of a unilateral comminuted and complicated fracture of the mandible due to dog attack on a geriatric patient. The attack also severed the patient's right arm. Due to the severity of the trauma, an emergency surgery was performed on the mandible and arm.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation
  14. Devnani AS
    Singapore Med J, 2002 Apr;43(4):205-7.
    PMID: 12188067
    Fracture neck of the femur is rare in children and occurs following severe trauma. Several recommendations have been made for the treatment of displaced transcervical fracture type 11 (Delbet classification). However there are no recommendations when such a fracture occurs after recent acute osteomyelits of the neck of the femur. The management of a case is described with the outcome after 36 months.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  15. Foead A, Penafort R, Saw A, Sengupta S
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):76-82.
    PMID: 15237126
    To conduct a prospective randomised controlled study to compare the stability and risk of nerve injury between fractures treated by medial-lateral pin fixation and those treated by 2-lateral pin fixation.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  16. Nordin S, Zulkifli O, Faisham WI
    Med J Malaysia, 2001 Dec;56 Suppl D:12-7.
    PMID: 14569760
    We studied 60 intertrochanteric fractures of the femur fixed with Dynamic Hip Screw (DHS). There were 10 cases (16.7%) with cutting-out of device through femoral head and neck. Stable fracture pattern, postero-inferior and central position of screw in the femoral neck and head produced high percentage of good result, whereas anterior or superior position of screw produced higher incidence of cut-out. We found osteoporosis and distance of screw tip to subchondral bone to have no influence on the final outcome.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  17. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  18. Ahmad AA, Ubaidah Mustapa Kamal MA, Ruslan SR, Abdullah S, Ahmad AR
    J Shoulder Elbow Surg, 2020 Nov;29(11):2319-2325.
    PMID: 32499198 DOI: 10.1016/j.jse.2020.03.003
    BACKGROUND: Fixation of clavicle fractures has now become a more popular option as it provides better outcome compared with conservative management. Wide-awake local anesthesia no tourniquet (WALANT) has been effectively used in plating of distal radius and olecranon fractures. This paper expands the usage of WALANT into the shoulder girdle, namely plating of the clavicle that has not been described. The operation is typically performed under general anesthesia.

    METHODS: We report a case series of 16 patients who successfully underwent fixation of the clavicle under the wide-awake technique. The clavicle fractures were grouped under the AO Fracture Classification. The WALANT solution comprised 1% lidocaine, 1:100,000 epinephrine, and 10:1 sodium bicarbonate. A total of 40 mL was injected in each patient with 10 mL subcutaneously along the clavicle followed by 30 mL subperiosteally at multiple intervals and directions.

    RESULTS: The Numerical Pain Rating Score was 0 during WALANT injection and during surgery except for 2 patients with Numerical Pain Rating Scores of 1 and 2, respectively, during reduction.

    CONCLUSION: We conclude that clavicle plating under WALANT is a good alternative option of anesthesia.

    Matched MeSH terms: Fracture Fixation, Internal/instrumentation
  19. Khademolhosseini M, Abd Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 Mar;22(2):123-6.
    PMID: 23222035 DOI: 10.1097/BPB.0b013e32835b2e14
    A retrospective study of nerve injuries with displaced supracondylar fractures of the humerus in children younger than 12 years of age, treated in Hospital Universiti Kebangsaan Malaysia. Our objectives were to determine the incidence of primary and iatrogenic nerve injuries in supracondylar humerus fractures Gartland types II and III and to determine the outcome of nerve recovery. A total of 272 patients with displaced supracondylar humerus fractures who required admission to Hospital Universiti Kebangsaan Malaysia from January 2000 to December 2007 were reviewed. There were 182 boys (67%) and 90 girls (33%). The mean age was 6.0 years, ranging from 1 to 12 years. Of 272 supracondylar fractures, 79 were type II and 193 were type III. Fifty-one (19%) patients had closed reduction, 160 (59%) had closed reduction and percutaneous crossed Kirschner (K) wires, and 61 (22%) had open reduction and crossed K-wires. Associated nerve injuries involving the median, radial, and ulnar nerves were observed in 48 (18%) patients. Nerve injuries were observed in nine (3%) patients upon admission. Thirty-nine (14%) patients developed nerve injuries following treatment. Of these 39 patients, 34 had ulnar, three had radial, and two had median nerve injuries. Nerve exploration was performed in five patients (in four patients following debridement of open fracture and in one because of unacceptable postoperative radiographs, and they subsequently underwent open reduction and exploration). Except for these five patients, the K-wires were not removed earlier nor were the nerves surgically explored in others. The nerve injuries resolved clinically on an average time of 3.5 months (range from 3 weeks to 8 months). Our study found complete resolution of all patients with nerve injuries confirmed by clinical assessment. On the basis of our study, we believe that there is no indication to remove the K-wires immediately or to explore the nerve surgically following a mini-open technique, which reduces the risk of penetrating a nerve during pinning.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  20. Yeap EJ, Rao J, Pan CH, Soelar SA, Younger ASE
    Foot Ankle Surg, 2016 Sep;22(3):164-169.
    PMID: 27502224 DOI: 10.1016/j.fas.2015.06.008
    BACKGROUND: This study compares the outcomes of calcaneal fracture surgery after open reduction internal fixation and plating (ORIF) versus arthroscopic assisted percutaneous screw fixation (APSF).

    METHODS: Group I (N=12) underwent ORIF. Group II (N=15) underwent APSF. Anthropometric data, pre and post-operative stay, complications and duration off work were recorded in this retrospective case cohort study. Radiographs were analyzed for Bohler's, Gissane's angle and Sanders' classification. AOFAS Hindfoot and SF 36 scores were collected at final follow-up.

    RESULTS: Anthropometric data, Bohler's and Gissane's angles, AOFAS and SF 36 scores were not significantly different. Pre-operative duration was 12.3 days in ORIF and 6.9 days in APSF. Post-operative duration was 7.3 days vs 3.8 days. Duration off work was 6.2 months vs 2.9 months.

    CONCLUSION: The APSF group was able to have surgery earlier, go home faster, and return to work earlier. This study was not powered to demonstrate a difference in wound complication rates.

    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*