METHODS: This cross-sectional study was conducted between December 2020 and March 2021 at Sarawak General Hospital, Malaysia. Convenience sampling was used to recruit patients with glaucoma who self-administered their eye drops. Participants' background information were obtained using an investigator-administered questionnaire before their eye drop instillation technique was assessed. Those with imperfect techniques were counselled by a pharmacist before being reassessed. Differences in eye drop instillation competency were determined using paired T-test.
KEY FINDINGS: A total of 138 participants were recruited. Participants were on a median of two eye drops (IQR 2-4) for a median of five years (IQR 2-8). Prior to being counselled, they demonstrated a mean total of 8.4/13 steps (SD 2.33) correctly. A statistically significant improvement in eye drop instillation technique was observed post-pharmacists' counselling, with a mean increase of 4.3 steps demonstrated correctly (95% CI, 4.0 to 4.7, P < 0.001). The majority of participants agreed that pharmacists are knowledgeable in providing counselling on eye drop administration techniques.
CONCLUSIONS: Patients with glaucoma treated at Sarawak General Hospital had imperfect eye drop instillation techniques, despite most having used their eye drops for several years. Interventions by pharmacists to improve eye drop instillation are crucial to optimise the medical treatment of patients with glaucoma.
METHODS: Scanning electron microscopy was performed on P50 and P200 devices. Bench-top flow studies were performed to find the resistances of the devices. Devices were also incorporated into a perfused, ex vivo porcine sclera model to test and compare their control of pressure, with and without overlying scleral flaps, and with trabeculectomies.
RESULTS: The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively. Those of the P50 device were 205.0±5.8 and 206.9±3.7 μm, respectively. There were no significant differences between the P200 and P50 devices (all P>0.05). The resistances of the P200 and P50 devices were 0.010±0.001 and 0.054±0.002 mm Hg/μL/min, respectively (P<0.05). Equilibrium pressures with overlying scleral flaps were 17.81±3.30 mm Hg for the P50, 17.31±4.24 mm Hg for the P200, and 16.28±6.67 mm Hg for trabeculectomies (P=0.850).
CONCLUSIONS: The luminal diameters of both devices are externally similar. The effective luminal diameter of the P50 is much larger than 50 μm. Both devices have low resistance values, making them unlikely to prevent hypotony on their own. They lead to similar equilibrium pressures as the trabeculectomy procedure when inserted under the scleral flap.
DESIGN: A combined cross-sectional and prospective study on PAC and PACG.
METHODS: A total of 35 eyes were included in the study for each group of normal control, PAC, and PACG patients from eye clinics in Kota Bharu, state of Kelantan, Malaysia, from January 2007 to November 2009. The PAC and PACG patients were divided into thin and thick CCT groups. They were followed up for 12 to 18 months for visual field progression assessment with their mean Advanced Glaucoma Intervention Study (AGIS) score.
RESULTS: The CCT was 516.8 ± 26.0 µm for PAC and 509.7 ± 27.4 µm for PACG. Both were significantly thinner compared with the control group with CCT of 540 ± 27.8 µm (P < 0.001). There was a statistically significant increase in the mean AGIS score after 12.9 ± 1.7 months of follow-up in the thin CCT group for PACG (P = 0.002). However, no significant increase in the mean AGIS score was found for the thick CCT group in PACG and for both thin and thick CCT in PAC.
CONCLUSIONS: The PAC and PACG had statistically significant thinner CCT compared with the controls. Thin CCT was associated with visual field progression based on the mean AGIS score in PACG.
PURPOSE: This study aimed to determine the prevalence of depression among patients with POAG and examine the relationship between depression and the severity of POAG in older adults.
MATERIALS AND METHODS: Three hundred and sixty patients with POAG aged 60 years or above were recruited from 2 tertiary centers located in an urban and suburban area. The participants were stratified according to the severity of their glaucoma based on the scores from the modified Advanced Glaucoma Intervention Study (AGIS) to mild, moderate, severe, and end stage. Face-to-face interviews were performed using the Malay Version Geriatric Depression Scale 14 (mGDS-14) questionnaire. Depression is diagnosed when the score is ≥8. One-way analysis of variance was used to compare the subscores between the groups. Multifactorial analysis of variance was also applied with relevant confounding factors.
RESULTS: Depression was detected in 16% of older adults with POAG; a higher percentage of depression was seen in those with end stage disease. There was a significant increase in the mean score of mGDS-14 according to the severity of POAG. There was evidence of an association between depression and severity of visual field defect (P<0.001). There was a significant difference in mGDS-14 score between the pairing of severity of POAG [mild-severe (P=0.003), mild-end stage (P<0.001), moderate-severe (P<0.001), and moderate-end stage (P<0.001)] after adjustment to living conditions, systemic disease, and visual acuity.
CONCLUSION: Ophthalmologists should be aware that older adults with advanced visual field defects in POAG may have depression. The detection of depression is important to ensure adherence and persistence to the treatment of glaucoma.