Displaying all 18 publications

Abstract:
Sort:
  1. Noor Azlinda Ahmad, Zawani Amirah Rasid, Zuraimy Adzis
    MyJurnal
    Lightning is among the most deadly natural phenomena to mankind. This phenomenon
    is seen to increase globally as well as in Malaysia. Lightning does strike open areas
    such as playing fields and playgrounds and these areas are places people gather.
    Sensors that can detect the early occurrence of lightning have been developed for
    detecting approaching lightning activity in this project. The main objective is to provide
    early lightning warning system to the public and hence to reduce the number of
    fatalities due to lightning strike. The warning circuit was designed and simulated using
    Multism11. Basic operational method of the circuit is based on the comparative
    voltage method using LM339N integrated circuit comparator (IC). Light Emitting Diodes
    (LEDs) were used as indicators to indicate if the incoming voltage level is higher or
    lower than that of the safety level.
    Matched MeSH terms: Lightning; Lightning Injuries
  2. Abd Rahman FA, Ab Kadir MZA, Ungku Amirulddin UA, Osman M
    Materials (Basel), 2021 Mar 29;14(7).
    PMID: 33805583 DOI: 10.3390/ma14071684
    The fourth rail transit is an interesting topic to be shared and accessed by the community within that area of expertise. Several ongoing works are currently being conducted especially in the aspects of system technical performances including the rail bracket component and the sensitivity analyses on the various rail designs. Furthermore, the lightning surge study on railway electrification is significant due to the fact that only a handful of publications are available in this regard, especially on the fourth rail transit. For this reason, this paper presents a study on the electrical performance of a fourth rail Direct Current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was modelled by means of the Rusck model and the sum of two Heidler functions. The simulations were carried out using the EMTP-RV software which included the performance comparison of polymer-insulated rail brackets, namely the Cast Epoxy (CE), the Cycloaliphatic Epoxy A (CEA), and the Glass Reinforced Plastic (GRP) together with the station arresters when subjected by 30 kA (5/80 µs) and 90 kA (9/200 µs) lightning currents. The results obtained demonstrated that the GRP material has been able to slightly lower its induced overvoltage as compared to other materials, especially for the case of 90 kA (9/200 µs), and thus serves better coordination with the station arresters. This improvement has also reflected on the recorded residual voltage and energy absorption capacity of the arrester, respectively.
    Matched MeSH terms: Lightning; Lightning Injuries
  3. Sharifah Sakinah, Tuan Othman, Jasronita, Jasni, Mohd Nazim, Mohtar
    MyJurnal
    Lightning is a natural phenomenon that generates a high electric field during thunderstorm. It has been
    reported that lightning strikes amid storms can occur around 100 times per second. The atmospheric
    electric field is an imperative parameter during a thunderstorm. Therefore, monitoring the electric field
    and its parameters is the best way for local lightning forecast. The electric field monitoring data can
    validate the accuracy of weather prediction in a local area from meteorology department or by using
    equipment specially designed to measure this electric field that exists when the phenomenon of lightning occurs. In this paper, the relationship between lightning, air humidity and temperature is discussed to understand the post lightning effect on these electric parameters. Additionally, the characteristics of the parameters are observed and analysed.
    Matched MeSH terms: Lightning; Lightning Injuries
  4. Chandima Gomes, Riyadh Z. Sabry
    MyJurnal
    The grounding system of a lightning protection scheme is designed basically to avoid arcing and
    dangerous step potentials. The grounding impedance of the system varies depending on soil structure and frequency. This paper describes the effect of harmonic impedance (also called frequency dependence of soil) on potential distribution under lightning strike to a metal tower with single grounding path, for different soil types. The results show that the peak value of ground potential rise (GPR) and step voltage (SP) may reach extremely hazardous values even at distances in the order of 90 m from the tower footing, especially when soil resistivity is high. Hence, we emphasise that, in contrast to power grounding, when designing of grounding systems that are meant to handle transient or high frequency currents as well, the frequency dependent soil parameters should be considered to avoid hazardous situations, especially at locations with a high probability of lightning strikes such as metal towers.
    Matched MeSH terms: Lightning; Lightning Injuries
  5. Nazri K, Lim SC, Gomes C
    F1000Res, 2021;10:921.
    PMID: 34909192 DOI: 10.12688/f1000research.73064.2
    Introduction: Malaysia is one of the countries with the highest lightning flash density globally. While sufficiency of lightning protection system is crucial to ensure human safety against lightning strikes, the public awareness towards lightning safety is also equally important in Malaysia. Hence, this study was conducted to understand the current lightning safety awareness level of the Malaysian population. Methods: An online questionnaire survey which consists of 22 scientific statements of lightning was first developed in Malay and English. The questionnaire allows the respondent to also check their own score upon completion of the questionnaire. It was then distributed to the public for data collection. The sample size comprised of both genders, all layers of society from various educational level and social background. Results: Overall, the awareness on lightning safety amongst Malaysian is at moderate level with an average score of slightly above 50%. Urbanites scored marginally better than their rural counterparts. One's education level does not dictate their awareness level of lightning safety. Discussion: In conclusion, the public in Malaysia needs to be better educated on lightning safety. Similar studies should be replicated in other countries experiencing similar levels of lightning activity to better understand the public's perception on lightning.
    Matched MeSH terms: Lightning*
  6. Gomes C
    Int J Biometeorol, 2012 Nov;56(6):1011-23.
    PMID: 22215021 DOI: 10.1007/s00484-011-0515-5
    This paper addresses a concurrent multidisciplinary problem: animal safety against lightning hazards. In regions where lightning is prevalent, either seasonally or throughout the year, a considerable number of wild, captive and tame animals are injured due to lightning generated effects. The paper discusses all possible injury mechanisms, focusing mainly on animals with commercial value. A large number of cases from several countries have been analyzed. Economically and practically viable engineering solutions are proposed to address the issues related to the lightning threats discussed.
    Matched MeSH terms: Lightning*; Lightning Injuries/economics; Lightning Injuries/prevention & control; Lightning Injuries/veterinary*
  7. Kumar V
    Med Sci Law, 2007 Apr;47(2):171-3.
    PMID: 17520964
    Lightning is a powerful natural electrostatic discharge produced during a thunderstorm. The electric current passing through the discharge channels is direct with a potential of 1000 million volts or more. Lightning can kill or injure a person by a direct strike, a side-flash, or conduction through another object. Lightning can cause a variety of injuries in the skin and the cardiovascular, neurological and ophthalmic systems. Filigree burn of lightning is a superficial burn and very rare. Two cases of death from lightning which have this rare finding are reported and discussed.
    Matched MeSH terms: Lightning*
  8. Izadi M, Abd Rahman MS, Ab-Kadir MZ, Gomes C, Jasni J, Hajikhani M
    PLoS One, 2017;12(2):e0172118.
    PMID: 28234930 DOI: 10.1371/journal.pone.0172118
    Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.
    Matched MeSH terms: Lightning*
  9. Krishnan R
    Family Physician, 1991;3:57-58.
    A 7 year-old Malay child with lightning burns is reported. Lightning injuries are rare. Victims who are clinically 'dead' may recover normally if resuscitation is carried out for prolonged periods.
    Matched MeSH terms: Lightning; Lightning Injuries
  10. Rozali, A., Khairuddin, H., Sherina, M.S., Chia, L.M.
    MyJurnal
    Lightning strikes have been known to cause fatal injuries. However, these cases have not been adequately highlighted in Malaysia. This paper reports on three cases of military personnel who lost their lives after being struck by lightning while on operational duties. It is extremely important to implement adequate safety measures and ensure that all military personnel are adequately trained on emergency procedures, such as Cardio Pulmonary Resuscitation (CPR) to prevent casualties of lightning strikes in future. This paper addresses several issues to avoid similar occurrences; the importance of taking extra safety precautions and recognizing signs of lightning strikes, as well as the immediate administration of CPR on victims.
    Matched MeSH terms: Lightning
  11. Chandima Gomes, Muhammad Noh Hamzah
    MyJurnal
    This paper presents the chaotic pulse train (CPT) waveforms of the vertical electric field generated by lightning observed in Malaysia. Focusing on the position where these electric field changes occur in a number of cloud to ground (CG) flashes, these CPTs were detected in different ways of occurrences, durations, intensities and amplitudes. Seventy-six chaotic pulse trains were found in this study from a sum of 172 CG flash records from three thunderstorm days. The fast field antenna was employed to do the field measurements. As opposed to the typical occurrence of chaotic pulse trains prior to subsequent strokes as reported in the literature, this study has found chaotic pulse trains occurring in different places along the CG electric field waveforms.
    Matched MeSH terms: Lightning
  12. Murty OP
    J Forensic Leg Med, 2007 May;14(4):225-7.
    PMID: 16914357
    This is a case report of an environmental accident due to lightning where one school boy sustained current, blast, and flame effects of it. A bolt of lightning directly struck the pole of a football ground and the scatter struck the child. In addition to burn injuries, he showed an exit wound of lightning in left foot. The exit wound of lightning current is a very rare finding. The body of victim had flame and heat effect of atmospheric electricity on head and neck, face, and trunk. In this incidence of lightning other team mates of the victim were safe. The patient survived the attack.
    Matched MeSH terms: Lightning Injuries/pathology*
  13. Nasir MSM, Ab-Kadir MZA, Radzi MAM, Izadi M, Ahmad NI, Zaini NH
    PLoS One, 2019;14(7):e0219326.
    PMID: 31295278 DOI: 10.1371/journal.pone.0219326
    The Sustainable Energy Development Authority of Malaysia (SEDA) regularly receives complaints about damaged components and distribution boards of PV systems due to lightning strikes. Permanent and momentary interruptions of distribution circuits may also occur from the disturbance. In this paper, a solar PV Rooftop system (3.91 kWp) provided by SEDA was modelled in the PSCAD/EMTDC. The Heidler function was used as a lightning current waveform model to analyse the transient current and voltage at two different points susceptible to the influence of lightning events such as different lightning current wave shape, standard lightning current and non-standard lightning current. This study examines the effect on the system components when lightning directly strikes at two different points of the installation. The two points lie between the inverter and the solar PV array and between inverter and grid. Exceptionally high current and voltage due to the direct lightning strike on a certain point of a PV Rooftop system was also studied. The result of this case study is observed with and without the inclusion of surge protective devices (SPDs). The parameters used were 31 kA of peak current, 10 metres cable length and lightning impulse current wave shape of 8/20μs. The high current and voltage at P1 striking point were 31 kA and 2397 kV, respectively. As for the AC part, the current and voltage values were found to be 5.97 kA and 5392 kV, respectively.Therefore, SPDs with suitable rating provided by SEDA were deployed. Results showed that high transient current voltage is expected to clamp sharply at the values of 1.915 kV and 0 A at the P1 striking point. As for the AC part, the current and voltage values were found to be 0 kA and 0.751 V, respectively. Varying lightning impulse current wave shapes at striking point P2 showed that the highest voltage was obtained at waveshape 10/350 μs at 11277 kV followed by wave shapes of 2/70 μs, 8/20 μs and 0.7/6 μs. The high value of transient voltage was clamped at a lower level of 2.029 kV. Different lightning amplitudes were also applied, ranging from 2-200 kA selected based on the CIGRE distribution. It showed that the current and voltage at P1 and P2 were directly proportional. Therefore, the SPD will be designed at an acceptable rating and proper position of SPD installation at solar PV Rooftop will be proposed. The results obtained in this study can then be utilised to appropriately assign a SPD to protect the PV systems that are connected to the grid. Installing SPDs without considering the needs of lightning protection zones would expose the expensive equipment to potential damage even though the proper energy coordination of SPDs is in place. As such, the simulation results provide a basis for controlling the impacts of direct lightning strikes on electrical equipment and power grids and thus justify SPD coordination to ensure the reliability of the system.
    Matched MeSH terms: Lightning*
  14. Norhafiz Azis, Yee Von Thien, Robiah Yunus, Zaini Yaakub
    MyJurnal
    In recent years, vegetable oil such as Palm Oil (PO) has been identified as a potential alternative dielectric insulating fluid for transformers. It is biodegradable, non-toxic and has high flash and fire points. In this paper, a study on the positive lightning impulse breakdown voltages of PO under non-uniform field is carried out. The testing was carried out using needle-plane electrodes configuration at gap distances of 25 mm and 50 mm. Rising voltage, 1 and 3 shots per step testing methods were used and 3 types of Refined Bleach and Deodorized Palm Oil (RBDPO) and Mineral Oil (MO) were examined. It was found there is no significant effect on the breakdown voltages of all samples. The breakdown voltages of all RBDPO at 50% probability are comparable with MO. At 1% probability and gap distance of 50 mm, the breakdown voltages of all RBDPO are lower than MO.
    Matched MeSH terms: Lightning
  15. Murty OP, Kian CK, Ari Husin MH, Nanta Kumar RK, Mohammed Yusuf WY
    Am J Forensic Med Pathol, 2009 Sep;30(3):246-51.
    PMID: 19704405 DOI: 10.1097/PAF.0b013e31819d20a4
    Lightning strike is a natural phenomenon with potentially devastating effects and represents one of the important causes of deaths from environmental phenomena. Almost every organ system may be affected as lightning current passes through the human body taking the shortest pathways between the contact points. A 10 years retrospective study (1996-2005) was conducted at University Hospital Kuala Lumpur (20 cases) also including cases during last 3 years from Hospital Tengku Ampuan Rahimah, Klang (7 cases) from the autopsy reports at Forensic Pathology Units of these 2 hospitals. Both these hospitals are attached to University of Malaya. There were 27 fatal cases of lightning strike with male preponderance(92.59%) and male to female ratio of 12.5:1. Majority of victims of lightning strike were from the age group between 30 and 39 years old. Most of the victims were foreign workers. Indonesians workers contributed to 59.26% of overall cases. Majority of them were construction workers who attributed i.e.11 of 27 cases (40.74%). Most of the victims were brought in dead (37.04%). In majority of the cases the lightning incidence occurred in the evenings, with the frequency of 15 of 27 cases (62.5%). The month of December represented with the highest number of cases (5 cases of 23 cases); 2004 had the highest incidence of lightning strike which was 5 (19.23%). Lightning strike incidence occurred when victims had taken shelter (25.9%) under trees or shades. Lightning strike in open areas occurred in 10 of 27 cases (37.0%). Head and neck were the most commonly affected sites with the incidence of 77.78% and 74% respectively in all the victims. Only 29.63% of the cases presented with ear bleeding.
    Matched MeSH terms: Lightning Injuries/mortality*; Lightning Injuries/pathology*
  16. Dallas MP, Horner R, Li L
    World Dev, 2021 Mar;139:105324.
    PMID: 33293754 DOI: 10.1016/j.worlddev.2020.105324
    Shortages of critical medical supplies during the COVID-19 pandemic have turned global value chains (GVCs) in personal protective equipment (PPE) into a political lightning rod. Some blame excessive outsourcing and foreign dependency for causing shortages, thus urging greater state intervention; others applaud GVCs for their flexibility and scaling up of production, while blaming states for undermining GVC operations. Using policy process-tracing and monthly trade data of seven PPE products across the US, Europe, China and Malaysia, this paper goes beyond the binary debate of either the 'failure' or 'success' of GVCs to show when and under what conditions states interacted with GVCs to produce mixed outcomes in provisioning countries with PPEs. We identify interactions between the type of state intervention and two key structural features of GVCs - geographic distribution of production and technological attributes of the product. Conceptually, the paper demonstrates the mutual constraints of states and GVCs, and highlights structural factors involved in the relationship. Looking to the future of GVCs, we caution against wholesale declarations that GVCs should be abandoned or maintained, instead concluding that paying attention to GVC structure, states and their interactions are crucial.
    Matched MeSH terms: Lightning
  17. Murty OP
    J Forensic Leg Med, 2009 Apr;16(3):162-7.
    PMID: 19239970 DOI: 10.1016/j.jflm.2008.07.009
    A case is presented of a fatal environmental accidental injuries of lightning. A pedestrian was struck by lightning. The macroscopic and microscopic lightning injuries are reviewed.
    Matched MeSH terms: Lightning Injuries/pathology*
  18. Suhaimi NS, Md Din MF, Ishak MT, Abdul Rahman AR, Mohd Ariffin M, Hashim N', et al.
    Sci Rep, 2020 Dec 02;10(1):20984.
    PMID: 33268816 DOI: 10.1038/s41598-020-77810-8
    In this paper, the electrical, dielectric, Raman and small angle X-ray scattering (SAXS) structure behavior of disposed transformer oil in the presence of multi-walled carbon nanotube (MWCNT) were systematically tested to verify their versatility for preparing better alternative transformer oil in future. MWCNT nanofluids are prepared using a two-step method with concentrations ranging from 0.00 to 0.02 g/L. The test results reveal that 0.005 g/L concentration possesses the most optimum performance based on the electrical (AC breakdown and lightning impulse) and dielectric (permittivity, dissipation factor and resistivity) behavior. According to the trend of AC breakdown strength and lightning impulse pattern, there were 212.58% and 40.01% enhancement indicated for 0.005 g/L concentration compared to the disposed transformer oil. The presence of MWCNT also yielding to the decrement of dissipation factor, increased on permittivity and resistivity behavior of disposed transformer oil which reflected to the performance of electrical properties. Furthermore, it is found that these features correlated to the structural properties as systematically verify by Raman and SAXS analysis study.
    Matched MeSH terms: Lightning
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links