Displaying publications 1 - 20 of 22 in total

Abstract:
Sort:
  1. Baashar Y, Alkawsi G, Wan Ahmad WN, Alomari MA, Alhussian H, Tiong SK
    PMID: 36900951 DOI: 10.3390/ijerph20053940
    Head-mounted displays (HMDs) have the potential to greatly impact the surgical field by maintaining sterile conditions in healthcare environments. Google Glass (GG) and Microsoft HoloLens (MH) are examples of optical HMDs. In this comparative survey related to wearable augmented reality (AR) technology in the medical field, we examine the current developments in wearable AR technology, as well as the medical aspects, with a specific emphasis on smart glasses and HoloLens. The authors searched recent articles (between 2017 and 2022) in the PubMed, Web of Science, Scopus, and ScienceDirect databases and a total of 37 relevant studies were considered for this analysis. The selected studies were divided into two main groups; 15 of the studies (around 41%) focused on smart glasses (e.g., Google Glass) and 22 (59%) focused on Microsoft HoloLens. Google Glass was used in various surgical specialities and preoperative settings, namely dermatology visits and nursing skill training. Moreover, Microsoft HoloLens was used in telepresence applications and holographic navigation of shoulder and gait impairment rehabilitation, among others. However, some limitations were associated with their use, such as low battery life, limited memory size, and possible ocular pain. Promising results were obtained by different studies regarding the feasibility, usability, and acceptability of using both Google Glass and Microsoft HoloLens in patient-centric settings as well as medical education and training. Further work and development of rigorous research designs are required to evaluate the efficacy and cost-effectiveness of wearable AR devices in the future.
    Matched MeSH terms: Surgery, Computer-Assisted*
  2. Waran V, Pancharatnam D, Thambinayagam HC, Raman R, Rathinam AK, Balakrishnan YK, et al.
    PMID: 23315670 DOI: 10.1055/s-0032-1330960
    Navigation in neurosurgery has expanded rapidly; however, suitable models to train end users to use the myriad software and hardware that come with these systems are lacking. Utilizing three-dimensional (3D) industrial rapid prototyping processes, we have been able to create models using actual computed tomography (CT) data from patients with pathology and use these models to simulate a variety of commonly performed neurosurgical procedures with navigation systems.
    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  3. Alirr OI, Abd Rahni AA
    Int J Comput Assist Radiol Surg, 2020 Feb;15(2):239-248.
    PMID: 31617057 DOI: 10.1007/s11548-019-02078-x
    PURPOSE: For the liver to remain viable, the resection during hepatectomy procedure should proceed along the major vessels; hence, the resection planes of the anatomic segments are defined, which mark the peripheries of the self-contained segments inside the liver. Liver anatomic segments identification represents an essential step in the preoperative planning for liver surgical resection treatment.

    METHOD: The method based on constructing atlases for the portal and the hepatic veins bifurcations, the atlas is used to localize the corresponding vein in each segmented vasculature using atlas matching. Point-based registration is used to deform the mesh of atlas to the vein branch. Three-dimensional distance map of the hepatic veins is constructed; the fast marching scheme is applied to extract the centerlines. The centerlines of the labeled major veins are extracted by defining the starting and the ending points of each labeled vein. Centerline is extracted by finding the shortest path between the two points. The extracted centerline is used to define the trajectories to plot the required planes between the anatomical segments.

    RESULTS: The proposed approach is validated on the IRCAD database. Using visual inspection, the method succeeded to extract the major veins centerlines. Based on that, the anatomic segments are defined according to Couinaud segmental anatomy.

    CONCLUSION: Automatic liver segmental anatomy identification assists the surgeons for liver analysis in a robust and reproducible way. The anatomic segments with other liver structures construct a 3D visualization tool that is used by the surgeons to study clearly the liver anatomy and the extension of the cancer inside the liver.

    Matched MeSH terms: Surgery, Computer-Assisted*
  4. Che S, Ismail NH, Wang W, Awang RA
    Medicine (Baltimore), 2025 Mar 14;104(11):e41922.
    PMID: 40101046 DOI: 10.1097/MD.0000000000041922
    RATIONALE: This case series explores dynamic navigation systems (DNS) in transmandibular nerve canal implantation for patients with limited jaw space due to the proximity of the inferior alveolar nerve (IAN). The aim is to demonstrate how DNS improves implant placement precision and safety in cases where traditional methods face challenges.

    PATIENT CONCERNS: The patients had limited bone height and proximity to the IAN, making traditional implant techniques challenging. Concerns included the risk of nerve damage and difficulties in achieving optimal implant placement due to anatomical constraints.

    DIAGNOSES: Both patients had severe bone resorption and insufficient bone height in the posterior mandible, with concerns about IAN positioning. The first patient had grade III mobility in tooth #46 with a periapical infection, while the second had bilateral posterior mandibular pain and grade III mobility in tooth #47.

    INTERVENTIONS: Implants were placed using DNS, allowing precise planning and real-time guidance during surgery. Based on cone beam computed tomography, preoperative planning assessed bone height and IAN proximity. DNS ensured accurate implant placement, avoiding nerve interference, while bone grafts and growth factors were applied for healing.

    OUTCOMES: Both cases showed successful implant placement without complications like nerve damage or implant misplacement. Follow-up cone beam computed tomography scans confirmed well-positioned implants, with minimal bone resorption in the first case over 2 years and stable conditions in the second case after 6 months.

    LESSONS: This series highlights DNS's effectiveness in improving implant accuracy and reducing nerve injury risks, suggesting its value in complex dental implant surgeries.

    Matched MeSH terms: Surgery, Computer-Assisted/methods
  5. Kwan MK, Chiu CK, Chan CYW, Zamani R, Hansen-Algenstaedt N
    J Orthop Surg (Hong Kong), 2017 7 28;25(2):2309499017722438.
    PMID: 28748740 DOI: 10.1177/2309499017722438
    PURPOSE: This study analysed the accuracy and safety of the fluoroscopic guided percutaneous screws in the upper thoracic vertebrae (T1-T6).

    METHODS: Computed tomography scans from 74 patients were retrospectively evaluated between January 2008 and December 2012. Pedicle perforations were classified by two types of grading systems. For medial, lateral, superior and inferior perforations: grade 0 - no violation; grade 1 - <2 mm; grade 2 - 2-4 mm and grade 3 - >4 mm. For anterior perforations: grade 0 - no violation; grade 1 - <4 mm; grade 2 - 4-6 mm and grade 3 - >6 mm.

    RESULTS: There were 35 (47.3%) male and 39 (52.7%) female patients with a total 260 thoracic pedicle screws (T1-T6) analysed. There were 32 screw perforations which account to a perforation rate of 12.3% (11.2% grade 1, 0.7% grade 2 and 0.4% grade 3). None led to pedicle screw-related complications. The perforation rate was highest at T1 (33.3%, all grade 1 perforations), followed by T6 (14.5%) and T4 (14.0%).

    CONCLUSION: Fluoroscopic guided percutaneous pedicle screws of the upper thoracic spine (T1-T6) are technically more demanding and carry potential risks of serious complications. Extra precautions need to be taken when fluoroscopic guided percutaneous pedicle screws are placed at T1 and T2 levels, due to high medial pedicular angulation and obstruction of lateral fluoroscopic images by the shoulder girdle and at T4-T6 levels, due to smaller pedicular width.

    Matched MeSH terms: Surgery, Computer-Assisted/adverse effects*; Surgery, Computer-Assisted/instrumentation
  6. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2015 Jan;25(1):246-57.
    PMID: 25189152 DOI: 10.1007/s00330-014-3391-7
    OBJECTIVE: This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system.

    METHODS: Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance.

    RESULTS: Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method.

    CONCLUSION: This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients.

    KEY POINTS: • Clinical experience on liver thermal ablation using CT-guided robotic system is reported. • The technical success, radiation dose, safety and performance level were assessed. • Thermal ablations were successfully performed, with an average performance score of 4.4/5.0. • Robotic-assisted ablation can potentially increase capabilities of less skilled interventional radiologists. • Cost-effectiveness needs to be proven in further studies.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  7. Hwang CF, Chen Y, Lin HC, Narayanan P, Oh SH, Truy E
    Biomed Res Int, 2015;2015:683967.
    PMID: 26240825 DOI: 10.1155/2015/683967
    Matched MeSH terms: Surgery, Computer-Assisted/trends*
  8. Afzal MR, Daoud EG, Cunnane R, Mulpuru SK, Koay A, Hussain A, et al.
    Heart Rhythm, 2018 06;15(6):841-846.
    PMID: 29427820 DOI: 10.1016/j.hrthm.2018.02.008
    BACKGROUND: Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval.

    OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS.

    METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site.

    RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals.

    CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  9. Tan BH, Sockalingam S, Ganesan D
    Br J Neurosurg, 2025 Apr;39(2):262-265.
    PMID: 37345453 DOI: 10.1080/02688697.2023.2225611
    OBJECTIVES: Posterior cervical foraminotomy is a surgical procedure used to treat unilateral cervical radiculopathy. It provides direct decompression of the nerve root without the necessity of fusion while maintaining cervical mobility. With the advancement in image-guidance technology and minimal access techniques, intra-operative CT has provided a safer, more accurate instrumentation placement with less radiation exposure to operative staff and provides better anatomical visualization quality compared to traditional intra-operative imaging techniques. This case series aims to address the applications of advanced image guidance in posterior cervical foraminotomy and describe the nuances.

    METHOD: A technical report on a series of seven cases on intraoperative CT navigation for posterior cervical foraminotomy surgery. Posterior cervical foraminotomy was performed in all patients under CT guided navigation system without an image intensifier. In one case after the foraminotomy, the extruded disc was carefully removed by gentle retraction.

    RESULT: From 1 January 2020 to 31 December 2021, a total of seven patients with nine cervical foraminotomy procedures were performed using the aid of CT-guided navigation. The series comprised five women and two men whose mean age was 50.6 years. In all cases, the radiculopathy symptoms were diminished significantly. There were no cases of instability on the dynamic cervical radiograph. There were no complications during the surgical procedure.

    CONCLUSION: The navigation also allows the surgeon to localise the index level accurately and appraise the adequacy of the intended decompression in three planes of the CT scan image. The ability to perform accurate spine navigation would be the precursor for robotic spinal surgery.

    Matched MeSH terms: Surgery, Computer-Assisted/methods
  10. Waran V, Tang IP, Karuppiah R, Abd Kadir KA, Chandran H, Muthusamy KA, et al.
    Br J Neurosurg, 2013 Dec;27(6):742-6.
    PMID: 23647078 DOI: 10.3109/02688697.2013.791667
    Abstract The endoscopic transnasal, transsphenoidal surgical technique for pituitary tumour excision has generally been regarded as a less invasive technique, ranging from single nostril to dual nostril techniques. We propose a single nostril technique using a modified nasal speculum as a preferred technique. We initially reviewed 25 patients who underwent pituitary tumour excision, via endoscopic transnasal transsphenoidal surgery, using this new modified speculum-guided single nostril technique. The results show shorter operation time with reduced intra- and post-operative nasal soft tissue injuries and complications.
    Matched MeSH terms: Surgery, Computer-Assisted/instrumentation*; Surgery, Computer-Assisted/methods*
  11. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2014 Jan;24(1):79-85.
    PMID: 23928933 DOI: 10.1007/s00330-013-2979-7
    OBJECTIVE: Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles.

    METHODS: We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions).

    RESULTS/CONCLUSION: Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff.

    KEY POINTS: • An early experience of robotic-assisted radiofrequency ablation is reported • Robotic-assisted RFA improves accuracy of hepatic lesion targeting • Robotic-assisted RFA makes the procedure technically easier with significant lower radiation dose.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  12. Vairavan N, Tajunisah I, Subrayan V, Waran V
    Orbit, 2009;28(6):442-3.
    PMID: 19929682 DOI: 10.3109/01676830903103365
    Surgical approaches are becoming increasingly minimally invasive, without compromising either safety or ease. Penetrating ocular foreign bodies has traditionally been approached either by intraocular or supraorbital access. We successfully attempted a minimally invasive approach to remove a retrobulbar foreign body under computer-assisted image guidance in a 19-year-old man involved in an industrial mishap.
    Matched MeSH terms: Surgery, Computer-Assisted*
  13. Habib MA, Ibrahim F, Mohktar MS, Kamaruzzaman SB, Rahmat K, Lim KS
    World Neurosurg, 2016 Apr;88:576-585.
    PMID: 26548833 DOI: 10.1016/j.wneu.2015.10.096
    BACKGROUND: Electroencephalography source imaging (ESI) is a promising tool for localizing the cortical sources of both ictal and interictal epileptic activities. Many studies have shown the clinical usefulness of interictal ESI, but very few have investigated the utility of ictal ESI. The aim of this article is to examine the clinical usefulness of ictal ESI for epileptic focus localization in patients with refractory focal epilepsy, especially extratemporal lobe epilepsy.

    METHODS: Both ictal and interictal ESI were performed by the use of patient-specific realistic forward models and 3 different linear distributed inverse models. Lateralization as well as concordance between ESI-estimated focuses and single-photon emission computed tomography (SPECT) focuses were assessed.

    RESULTS: All the ESI focuses (both ictal and interictal) were found lateralized to the same hemisphere as ictal SPECT focuses. Lateralization results also were in agreement with the lesion sides as visualized on magnetic resonance imaging. Ictal ESI results, obtained from the best-performing inverse model, were fully concordant with the same cortical lobe as SPECT focuses, whereas the corresponding concordance rate is 87.50% in case of interictal ESI.

    CONCLUSIONS: Our findings show that ictal ESI gives fully lateralized and highly concordant results with ictal SPECT and may provide a cost-effective substitute for ictal SPECT.

    Matched MeSH terms: Surgery, Computer-Assisted/methods*
  14. Chiu CK, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2017 May-Aug;25(2):2309499017713938.
    PMID: 28705124 DOI: 10.1177/2309499017713938
    PURPOSE: This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients.

    METHODS: Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation.

    RESULTS: In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%).

    CONCLUSION: The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
    Matched MeSH terms: Surgery, Computer-Assisted*
  15. Philip R, Prepageran N, Waran V
    J Laryngol Otol, 2007 Sep;121(9):e14.
    PMID: 17625037
    Sphenoid sinus mucoceles comprise 1-2 per cent of paranasal sinus mucoceles. Endoscopic marsupialisation is currently the treatment of choice.
    Matched MeSH terms: Surgery, Computer-Assisted
  16. Anderson I, Kumar R, Patankar T, Tyagi A
    BMJ Case Rep, 2014;2014.
    PMID: 25257888 DOI: 10.1136/bcr-2014-205736
    We present the case of a 24-year-old man who presented with vertigo and right-sided weakness. Subsequent imaging demonstrated a lateral ventricle haemangioblastoma. This is the first case ever to be treated with surgical excision augmented by preoperative endovascular embolisation, as illustrated with perfusion CT scanning performed pre-embolisation and postembolisation. We present the case followed by a summary of the previously published cases and a discussion of the advantages of perfusion scanning and endovascular embolisation in these highly vascular (and therefore potentially dangerous) lesions.
    Matched MeSH terms: Surgery, Computer-Assisted
  17. Azlan CA, Mohd Nasir NF, Saifizul AA, Faizul MS, Ng KH, Abdullah BJ
    Australas Phys Eng Sci Med, 2007 Dec;30(4):288-91.
    PMID: 18274069
    Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.
    Matched MeSH terms: Surgery, Computer-Assisted
  18. Chai FY, Farizal F, Jegan T
    Turk Neurosurg, 2013;23(4):561-3.
    PMID: 24101284 DOI: 10.5137/1019-5149.JTN.5724-12.1
    Ventriculostomy or external ventricular drain (EVD) placement by free-hand technique has a high malplacement rate. It is a blind procedure that often requires multiple attempts and revisions. To date, no neurological complication due to EVD malplacement has been reported in the literature. In this report, we present the first case of coma induced by a malplaced EVD and the patient regained consciousness after the drain was adjusted. Our discussion focused on various techniques that can improve the accuracy of EVD insertion. EVD insertion under image guidance provides better accuracy with limited disadvantages. We hypothesized that the patient's coma was due to the mass effect and irritation of the malplaced EVD exerted onto the ventral periaqueductal grey matter and the ascending neurons from upper brainstem.
    Matched MeSH terms: Surgery, Computer-Assisted
  19. Nair SR, Rahmat K, Alhabshi SM, Ramli N, Seong MK, Waran V
    Clin Neurol Neurosurg, 2013 Jul;115(7):1150-3.
    PMID: 23031746 DOI: 10.1016/j.clineuro.2012.09.014
    Matched MeSH terms: Surgery, Computer-Assisted
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links