Methods: This multi-centre, international, single-arm, prospective observational study aimed at demonstrating the non-inferiority of a mid-term absorbable monofilament in comparison to braided sutures in gastrointestinal anastomosis. Monosyn suture was used to create the gastrointestinal anastomosis and the frequency of anastomotic leakage until day of discharge was chosen as the primary parameter. The outcome was compared to the results published for braided sutures in the literature. Secondary parameters were the time to perform the anastomosis, length of hospital stay, costs, and postoperative complications.
Results: The anastomosis leakage rate was 2.91%, indicating that Monosyn suture was not inferior to braided sutures used in gastrointestinal anastomosis. Of the reported anastomotic suture techniques, the single layer continuous method was the fastest and most economical technique in the present observational study.
Conclusion: Monosyn suture is safe and effective in gastrointestinal anastomosis and represents a good alternative to other sutures used for gastrointestinal anastomosis. With regard to safety, time and cost-efficiency, the single-layer continuous technique should be considered a preferred method. The transfer of results from clinical studies into daily practice with regard to surgical techniques for gastrointestinal anastomosis should be further evaluated in larger studies or in nationwide registries.
AIM: To investigate the effect of four commonly used wound care regimens on the tensile strength of suture materials.
METHODS: The failure load of 9 different suture materials was tested using the Instron Electroplus E3000 tensile testing machine (Instron Corporation, Norwood, Massachusetts). Tensile strength was represented as the failure load, measured in Newtons (N), and defined as the maximal load that could be applied across the suture prior to failure. Each suture was tested dry and after immersion in one of 4 products for 7 days and tested on day 7. The immersion agents tested were: sodium chloride 0.9%, MicroSafe® (Sonoma Pharmaceuticals, Petaluma, CA), Aqueous Povidone-iodine 10% solution (Betadine-Mundipharma), and Fucidin ointment.
RESULTS: Sodium chloride 0.9%, MicroSafe®, Aqueous Povidone-iodine 10%, and Fucidin seem to increase the failure load of most absorbable and non-absorbable sutures. However, the failure load of Polyglactin 910 suture (Surgilactin, coated, violet-Ethicon) is reduced by long-term exposure to either sodium chloride 0.9% or MicroSafe®, while the failure load of the Polydioxanone suture (PDS Plus-Ethicon) is reduced by long-term exposure to MicroSafe® only.
CONCLUSION: In our experiment, the commonly used wound care products have been shown to alter the tensile strength of suture materials. Further human studies are required to ascertain the clinical validity and applicability of our findings.
MATERIALS AND METHODS: Eight rabbits were randomized into Giftbox and Krackow groups. Tenotomy was performed on the Achilles tendon of one side of the lower limb and repaired with the respective techniques. The contralateral limb served as control. Subjects were euthanized six weeks post-operative, and both repaired and control Achilles tendons were harvested for biomechanical tensile test.
RESULTS: The means of maximum load to rupture and tenacity in the Giftbox group (156.89 ± 38.49 N and 159.98 ± 39.25 gf/tex) were significantly different than Krackow's (103.55 ± 27.48 N and 104.91 ± 26.96 gf/tex, both p = 0.043).
CONCLUSION: The tendons repaired with Giftbox technique were biomechanically stronger than those repaired with Krackow technique after six weeks of tendon healing.
METHODS: A 37-item questionnaire-based survey was conducted to capture the perioperative practices of the global community of bariatric surgeons. Data were analyzed using descriptive statistics.
RESULTS: Response of 863 bariatric surgeons from 67 countries with a cumulative experience of 520,230 SGs were recorded. A total of 689 (80%) and 764 (89%) surgeons listed 13 absolute and relative contraindications, respectively. 65% (n = 559) surgeons perform routine preoperative endoscopy and 97% (n = 835) routinely use intraoperative orogastric tube for sizing the resection. A wide variation is observed in the diameter of the tube used. 73% (n = 627) surgeons start dividing the stomach at a distance of 3-5 cm from the pylorus, and 54% (n = 467) routinely use staple line reinforcement. Majority (65%, n = 565) of surgeons perform routine intraoperative leak test at the end of the procedure, while 25% (n = 218) surgeons perform a routine contrast study in the early postoperative period. Lifelong multivitamin/mineral, iron, vitamin D, calcium, and vitamin B12 supplementation is advocated by 66%, 29%, 40%, 38% and 44% surgeons, respectively.
CONCLUSION: There is a considerable variation in the perioperative practices concerning SG. Data can help in identifying areas for future consensus building and more focussed studies.
METHODS: Patients undergoing elective midline laparotomy through standardized incisions in two tertiary hospitals from February 2017 to September 2018 were randomized to either LS or SS. The primary outcome was post-operative patient-controlled analgesia morphine usage at 24 h. Secondary outcomes were presence of surgical site infection and length of hospital stay (LOHS). Categorical variables were analysed using chi-squared analysis. Outcomes of study were tested for normal distribution. Skewed data were analysed using Mann-Whitney U-test.
RESULTS: Eighty-six patients were recruited (42 SS and 44 LS). The median age was 66 (interquartile range (IQR) 15). Majority were males (62.8%) and Chinese (50%). The median incision length was 17 cm in both groups. The median patient-controlled analgesia morphine usage 24 h post-operatively did not differ significantly (SS 21 mg, IQR 28.3; LS 18.5 mg, IQR 33.8, P = 0.829). The median pain score at rest (SS 1, IQR 1; LS 1, IQR 2, P = 0.426) and movement (SS 3, IQR 1; LS 3, IQR 2, P = 0.307) did not differ significantly. LOHS was shorter in the SS group (SS 6, IQR 4; LS 8, IQR 5, P = 0.034). The rate of surgical site infection trended lower in the SS group with no statistical difference.
CONCLUSION: There were no differences in post-operative pain between SS and LS but we found that there were shorter LOHS in SS arm as secondary outcome.
METHODS: A meta-analysis and systematic review of MEDLINE, PubMed Central (via PubMed), Embase (via Ovid), SCOPUS, ScienceDirect, Google Scholar, SCI and Cochrane Library databases were undertaken. Seven randomized controlled trials assessing the outcomes of PSR and POMR were analyzed in accordance with the PRISMA statement. The risk of bias was assessed using the Rob2 tool.
RESULTS: According to the pooled analysis, POMR significantly reduced the incidence of IH compared to the PSR (OR 5.82 [95% CI 2.69, 12.58] P