Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Raman S, Ramanujam T, Lim CT
    J Obstet Gynaecol Res, 1996 Aug;22(4):375-8.
    PMID: 8870422
    Extensive haemangioma with platelet consumption (Kasabach-Merritt syndrome) is rare. The lesion is usually a single cutaneous cavernous haemangioma similar to that found in our patient. Multiple superficial strawberry naevi were also seen all over the rest of the body. This condition was diagnosed antenatally in this patient with the use of colour Doppler. There is one recent report where the thrombocytopaenia was diagnosed by cordocentesis. Unfortunately the baby developed heart failure with intractable coagulopathy and died 2 days later.
    Matched MeSH terms: Ultrasonography, Prenatal*
  2. Japaraj RP, Mimin TS, Mukudan K
    J Obstet Gynaecol Res, 2007 Aug;33(4):431-7.
    PMID: 17688608
    To determine the accuracy of transabdominal and transvaginal gray-scale and color Doppler in diagnosing placenta previa accreta in patients with previous cesarean sections.
    Matched MeSH terms: Ultrasonography, Prenatal/methods*
  3. Menon DK
    Twin Res Hum Genet, 2005 Jun;8(3):259-61.
    PMID: 15989753
    The aim of this study was to determine the accuracy of sonographic chorionicity determination in the largest sample of twin pregnancies to date. We retrospectively analyzed 463 twin pregnancies delivered over a 6-year period to determine in each case what the antenatal sonographic prediction of chorionicity was, and then what the subsequent post partum pathological diagnosis of chorionicity was. Out of 436 twin pregnancies, 428 were correctly diagnosed for chorionicity as confirmed by pathology reports. Sonography as a screening tool for monochorionic twin pregnancies has a sensitivity of 100%, a specificity of 97.9% and a predictive value positive of 88.2%. Transvaginal scanning in the first trimester determined twin chorionicity with a sensitivity and a specificity of 100%. This study has confirmed in the largest sample to date that sonographic chorionicity determination is best done in the first trimester using vaginal scans, where it has 100% accuracy.
    Matched MeSH terms: Ultrasonography, Prenatal*
  4. McKelvey A, Pateman K, Balchin I, Peebles DM, Rodeck CH, David AL
    Ultrasound Obstet Gynecol, 2017 Jan;49(1):54-60.
    PMID: 26990029 DOI: 10.1002/uog.15917
    OBJECTIVES: To investigate the relationship between total uterine artery blood volume flow rate (TVFR) and birth weight and gestational age at delivery, and to establish normal ranges of TVFR throughout pregnancy.

    METHODS: This was a prospective cohort study of 334 nulliparous women booking antenatal care at University College London Hospital between August 2008 and September 2009. Women underwent a transabdominal ultrasound examination of uterine arteries for measurement of TVFR at 12, 20 and 24 weeks' gestation. Pregnancy outcomes were recorded and linear regression was used to study the relationship between TVFR and gestational age at delivery and birth weight.

    RESULTS: A total of 551 ultrasound scans were performed. There was a significant, positive correlation between TVFR at 11-13 weeks (TVFR1) and at 22-26 weeks (TVFR3) and birth weight. For every 100-mL/min increase in TVFR1 and TVFR3, there was an increase in birth weight of 45 g and 27 g, respectively. There was also a positive association between TVFR1 and gestational age at delivery, with a 1.4-day increase in gestational age for every 100-mL/min increase of TVFR1.

    CONCLUSION: Ultrasound measurement of TVFR in the first trimester is significantly associated with both birth weight and gestational age at delivery. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

    Matched MeSH terms: Ultrasonography, Prenatal/methods*
  5. Tan NH, Abu M, Woo JL, Tahir HM
    Aust N Z J Obstet Gynaecol, 1995 Feb;35(1):42-5.
    PMID: 7771998 DOI: 10.1111/j.1479-828x.1995.tb01828.x
    Transvaginal sonography was performed in 70 patients diagnosed to have placenta praevia by transabdominal sonography. The diagnosis was confirmed either by digital examination in theatre at term or operative finding at delivery. Forty-nine cases (70%) were correctly diagnosed to have placenta praevia by both modes of sonography. Transvaginal sonography ruled out placenta praevia in 12 cases (17%) thought to be placenta praevia by transabdominal ultrasound. Both transabdominal and transvaginal sonography demonstrated 'placental migration' in 4 cases (6%) which were no longer praevia at delivery. Five patients (7%) were erroneously believed to have placenta praevia by both sonographic techniques. Overall, the diagnostic accuracy of transvaginal sonography was 92.8% compared with 75.7% for transabdominal sonography. None of the subjects experienced any exacerbation of bleeding or other complications. The results suggest that transvaginal sonographic localization of the placenta is safe and superior to the transabdominal route.
    Matched MeSH terms: Ultrasonography, Prenatal/methods*
  6. Chandran R, Serra-Serra V, Sellers SM, Redman CW
    Br J Obstet Gynaecol, 1993 Feb;100(2):139-44.
    PMID: 8476805
    OBJECTIVE: To establish reference ranges for the human fetal middle cerebral artery pulsatility index (MCA PI) for the local obstetric population, and to compare computerised antenatal fetal heart rate (FHR) analysis with the MCA PI as indicators of fetal compromise.

    DESIGN: Prospective data collection for selected patients.

    SETTING: High risk pregnancy unit of a teaching hospital.

    SUBJECTS: Group 1 consisted of 18 healthy women with uncomplicated singleton pregnancies. Group 2 consisted of 27 women admitted to the high risk pregnancy unit over a 9 month period with intrauterine growth retardation and other related problems; all these women were delivered by prelabour caesarean section.

    INTERVENTION: Serial Duplex sonography to determine fetal MCA PI in Groups 1 and 2. Serial FHR analysis using computerised numerical techniques in Group 2 only.

    MAIN OUTCOME MEASURES: Serial MCA PI values from 24 to 39 completed weeks of gestation in Group 1. Comparison of serial MCA PI values with FHR analysis in relation to fetal outcome in Group 2.

    RESULTS: In Group 1 the MCA PI diminished significantly as gestation advanced from 1.73 (SD 0.25) at 24 weeks to 1.38 (SD 0.26) at 39 weeks (P < 0.01). In Group 2 eleven babies were hypoxaemic at delivery: all had low MCA PI values while only nine had an abnormal FHR prior to delivery.

    CONCLUSION: In normal pregnancy, there is a fall in the fetal MCA PI with advancing gestation which probably reflects a decreasing vascular resistance to fetal cerebral blood flow. Hypoxaemia at delivery appeared to be better recognised by the fetal MCA flow velocity waveform than the FHR analysis. This increased sensitivity, however, was achieved at the expense of a reduced specificity. Larger studies are needed to confirm the findings of this preliminary investigation.

    Matched MeSH terms: Ultrasonography, Prenatal*
  7. Yip KW, Cheng YKY, Leung TY
    Med J Malaysia, 2017 04;72(2):126-127.
    PMID: 28473678 MyJurnal
    In-utero intestinal volvulus is a rare but potential life threatening foetal complications. It is a surgical emergency and delay in diagnosis or treatment can increase the morbidity and mortality to the foetus. We report a case of mild foetal bowel dilatation diagnosed at 21 weeks of gestation. She was closely follow up and at 31 weeks of gestation, in-utero intestinal volvulus was diagnosed with the characteristic 'whirlpool' sign on ultrasound examination. This case emphasises the importance of early recognition and quick decision to delivery when intestinal volvulus is diagnosed. This enabled early surgical intervention to prevent further foetal morbidity.
    Matched MeSH terms: Ultrasonography, Prenatal*
  8. Hong J, Hong J, Thomas J, Kumar S
    Ultrasound Obstet Gynecol, 2024 Jul;64(1):120-121.
    PMID: 38197232 DOI: 10.1002/uog.27574
    Matched MeSH terms: Ultrasonography, Prenatal
  9. Lim PS, Ng BK, Ali A, Shafiee MN, Kampan NC, Mohamed Ismail NA, et al.
    ScientificWorldJournal, 2014;2014:860107.
    PMID: 24587759 DOI: 10.1155/2014/860107
    To determine the maternal and fetal outcomes of successful external cephalic version (ECV) as well as factors predicting vaginal birth.
    Matched MeSH terms: Ultrasonography, Prenatal
  10. Amelia A, Mohd Nizam MB
    Med J Malaysia, 2013 Aug;68(4):374-5.
    PMID: 24145275 MyJurnal
    Primary cardiac tumours in the foetuses and neonates are uncommon. Foetuses with cardiac tumour have risk for heart failure and hydrops fetalis. Therefore, an early decision for delivery should be made in the evidence of foetal compromise. Early neonatal care varies on tumour size, type, location and obstructive features. Antenatal detection of foetal cardiac tumours ensures better prenatal and postnatal management. We describe our 5- year experience in managing 5 cases of primary cardiac tumours from 1st January 2006 to 31st December 2010.
    Matched MeSH terms: Ultrasonography, Prenatal
  11. Raman S, Rachagan SP, Lim CT
    J Clin Ultrasound, 1991 Sep;19(7):434-7.
    PMID: 1658071
    Matched MeSH terms: Ultrasonography, Prenatal
  12. Nadzirah Mohamad Radzi, Farah Wahida Ahmad Zaiki
    MyJurnal
    The application of ultrasound technology has been widely accepted in clinical settings, particularly in Obstetrics and Gynaecology. This is in light of its ability to detect early foetal malformations apart from enabling foetal monitoring throughout gestation. While ultrasonography is an imaging method that is regularly used in Obstetrics, it is questionable as to whether it is safe for foetuses. The purpose of this paper was to review the evidence regarding the thermal effects of ultrasound exposure on foetal development, particularly. It is hoped that the importance of prudent usage of prenatal ultrasonography will be impressed on clinicians and the public in order to avoid the unnecessary usage of ultrasonography when it is not medically indicated. This is so that the welfare of pregnant women will be looked after, besides contributing to the better health of the next generation by ensuring that the benefits outweigh the known risks or potential harms.
    Matched MeSH terms: Ultrasonography, Prenatal
  13. Azian AA, Roslani AL
    Med J Malaysia, 2011 Dec;66(5):510-2.
    PMID: 22390115 MyJurnal
    An acardiac twin is rare and the diagnosis is commonly achieved from antenatal ultrasound (US) scans. However there have been cases where the appearances of the acardiac twin can be confusing and mimics a mass or tumour, for example, a teratoma. We experienced a case where the findings were unclear from the antenatal ultrasound scans and we had to resort to Magnetic Resonance Imaging (MRI), where we finally made the correct diagnosis based on the identification of two umbilical cords, supplying the normal fetus and the 'mass' (acardiac twin) respectively.
    Matched MeSH terms: Ultrasonography, Prenatal*
  14. Rahmatullah B, Besar R
    J Med Eng Technol, 2009;33(6):417-25.
    PMID: 19637083 DOI: 10.1080/03091900802451232
    The motivation of this paper is to analyse the efficiency and reliability of our proposed algorithm of femur length (FL) measurement for the estimation of gestational age. The automated methods are divided into the following components: threshold, segmentation and extraction. Each component is examined, and improvements are made with the objective of finding the optimal result for FL measurement. The methods are tested with a total of 200 different digitized ultrasound images from our database collection. Overall, the study shows that the watershed-based segmentation method combined with enhanced femur extraction algorithm and a 12 x 12 block averaging seed-point threshold method perform identically well with the expert measurements for every image tested and superior as compared to a previous method.
    Matched MeSH terms: Ultrasonography, Prenatal/methods*
  15. Mansor W, Crowe JA, Woolfson M, Hayes-Gill BR, Blanchfield P, Bister M
    Conf Proc IEEE Eng Med Biol Soc, 2007 10 20;2006:1383-6.
    PMID: 17945640
    In fetal heart monitoring using Doppler ultrasound signals the cardiac information is commonly extracted from non-directional signals. As a consequence often some of the cardiac events cannot be observed clearly which may lead to the incorrect detection of the valve and wall motions. Here, directional signals were simulated to investigate their enhancement of cardiac events, and hence provide clearer information regarding the cardiac activities. First, fetal Doppler ultrasound signals were simulated with signals encoding forward and reverse motion then obtained using a pilot frequency. The simulation results demonstrate that the model has the ability to produce realistic Doppler ultrasound signals and a pilot frequency can be used in the mixing process to produce directional signals that allow the simulated cardiac events to be distinguished clearly and correctly.
    Matched MeSH terms: Ultrasonography, Prenatal/methods*
  16. Raman S, Urquhart R, Yusof M
    Aust N Z J Obstet Gynaecol, 1992 Aug;32(3):196-9.
    PMID: 1445124
    A prospective study was carried out on 50 patients who had their fetal weight estimated by 3 clinicians of different seniority and compared to the ultrasound estimated fetal weights using 3 different formulas. All the patients delivered within 24 hours of their clinical and ultrasound estimates. A wide range of birth-weights (1,800-4,500 g) was estimated among the 3 different races (Malay, Chinese and Indians). The results showed that there was no significant difference in birth-weight estimation amongst the 3 clinicians as well as between the 3 ultrasound formulas used. There was however significant difference between these 2 groups when compared with the actual birthweight with clinical estimation being superior to ultrasound estimation in our population. This level of significance did not extend beyond 4,000 g fetal weight (actual) thus making both clinical and ultrasound estimation of fetal weight equally accurate after 4,000 g. This has important implications for developing countries where there is a lack of technologically advanced ultrasound machines capable of doing sophisticated functions like fetal weight estimations but has experienced clinicians who could perform this function equally well if not better.
    Matched MeSH terms: Ultrasonography, Prenatal*
  17. Raman S, Chan LL, Chang KW, Rachagan SP
    Med J Malaysia, 1992 Sep;47(3):228-30.
    PMID: 1491650
    A case of intestinal obstruction due to ileal atresia where the diagnosis was made prenatally by ultrasound is presented. Close monitoring of the fetus was done ultrasonographically to look for any evidence of meconium peritonitis. The baby was delivered preterm but weighed 3.3 kg. Laparotomy and enterostomy was done and the baby is currently well.
    Matched MeSH terms: Ultrasonography, Prenatal*
  18. Neoh HS, Kumarasamy S, Raman S
    Med J Malaysia, 1990 Mar;45(1):37-41.
    PMID: 2152067
    This report deals with the use of a relatively new investigative technique (Doppler ultrasound) in the management of a case of early onset pre-eclampsia and discusses the benefit of this new technique over conventional methods of fetal monitoring.
    Matched MeSH terms: Ultrasonography, Prenatal*
  19. Omar PM, Lim WT, Ting YH, Lao TT, Law KM, Cheung AHK, et al.
    J Matern Fetal Neonatal Med, 2019 Oct;32(19):3315-3317.
    PMID: 29631451 DOI: 10.1080/14767058.2018.1459556
    The association between hypoechoic hepatomegaly in the third trimester and transient abnormal myelopoiesis (TAM) was reported previously in six fetuses with trisomy 21 (T21). We report a series of three cases of T21 in which hypoechoic liver (HL) was found in the second trimester but without evidence of TAM on both hematological and histological examination. We postulate that the hypo-echogenicity may be due to liver congestion secondary to hemodynamic disturbances seen in T21 fetuses. All three cases had negative first trimester Down syndrome screening and one case was detected solely because of the isolated finding of HL. HL per se may be associated with T21 and more positive cases are required to support this association.
    Matched MeSH terms: Ultrasonography, Prenatal*
  20. Jahanfar S, Ho JJ, Jaafar SH, Abraha I, Noura M, Ross CR, et al.
    Cochrane Database Syst Rev, 2021 03 09;3:CD012553.
    PMID: 33686672 DOI: 10.1002/14651858.CD012553.pub2
    BACKGROUND: There is a need to standardize monitoring in obstetric research of twin pregnancies. Identification of birth weight discordance (BWD), defined as a difference in the birth weights of twins, is a well-documented phenomenon in twin pregnancies. Ultrasound for the diagnosis of BWD informs complex decision making including whether to intervene medically (via laser photo coagulation) or deliver the twins to avoid fetal morbidities or even death. The question is, how accurate is this measurement?

    OBJECTIVES: To determine the diagnostic accuracy (sensitivity and specificity) of ultrasound estimated fetal weight discordance (EFWD) of 20% and 25% using different estimated biometric ultrasound measurements compared with the actual BWD as the reference standard in twin pregnancies.

    SEARCH METHODS: The search for this review was performed on 15 March 2019. We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), seven other databases, conference proceedings, reference lists and contacted experts. There were no language or date restrictions applied to the electronic searches, and no methodological filters to maximize sensitivity.

    SELECTION CRITERIA: We selected cohort-type studies with delayed verification that evaluated the accuracy of biometric measurements at ultrasound scanning of twin pregnancies that had been proposed for the diagnosis of estimated BWD, compared to BWD measurements after birth as a reference standard. In addition, we only selected studies that considered twin pregnancies and applied a reference standard for EFWD for the target condition of BWD.

    DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility, and extracted data to create 2 × 2 tables. Two review authors independently performed quality assessment using the QUADAS-2 tool. We excluded studies that did not report data in sufficient detail to construct 2 × 2 tables, and where this information was not available from the primary investigators. We assessed the certainty of the evidence using the GRADE approach.

    MAIN RESULTS: We included 39 eligible studies with a median study sample size of 140. In terms of risk of bias, there were many unclear statements regarding patient selection, index test and use of proper reference standard. Twenty-one studies (53%) were of methodological concern due to flow and timing. In terms of applicability, most studies were of low concern. Ultrasound for diagnosis of BWD in twin pregnancies at 20% cut-off Twenty-two studies provided data for a BWD of 20% and the summary estimate of sensitivity was 0.51 (95% CI 0.42 to 0.60), and the summary estimate of specificity was 0.91 (95% CI 0.89 to 0.93) (8005 twin pregnancies; very low-certainty evidence). Ultrasound for diagnosis of BWD in twin pregnancies at 25% cut-off Eighteen studies provided data using a BWD discordance of 25%. The summary estimate of sensitivity was 0.46 (95% CI 0.26 to 0.66), and the summary estimate of specificity was 0.93 (95% CI 0.89 to 0.96) (6471 twin pregnancies; very low-certainty evidence). Subgroup analyses were possible for both BWD of 20% and 25%. The diagnostic accuracy did not differ substantially between estimation by abdominal circumference and femur length but femur length had a trend towards higher sensitivity and specificity. Subgroup analyses were not possible by sex of twins, chorionicity or gestational age due to insufficient data.

    AUTHORS' CONCLUSIONS: Very low-certainty evidence suggests that EFWD identified by ultrasound has low sensitivity but good specificity in detecting BWD in twin pregnancies. There is uncertain diagnostic value of EFWD; this review suggests there is insufficient evidence to support this index as the sole measure for clinical decision making to evaluate the prognosis of twins with growth discordance. The diagnostic accuracy of other measures including amniotic fluid index and umbilical artery Doppler resistive indices in combination with ultrasound for clinical intervention requires evaluation. Future well-designed studies could also evaluate the impact of chorionicity, sex and gestational age in the diagnostic accuracy of ultrasound for EFWD.

    Matched MeSH terms: Ultrasonography, Prenatal/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links