METHODS: This was a prospective study conducted at a tertiary hospital in Malaysia, from 1st August 2010 until 31st July 2011. Children aged between 1 mo and 12 y who were admitted for CAP and had blood cultures performed before starting intravenous antibiotics were recruited. Children with congenital pneumonia, immunodeficiency, chronic cardiac or respiratory disorders, nosocomial pneumonia or those on corticosteroids, were excluded. Decision for admission was made by the attending Accident and Emergency physician.
RESULTS: One hundred and seventy-one children were enrolled. The median age was 13 mo (range: 38 d-10 y 3 mo) and 59 % were males. Blood cultures were positive in 1.2 % (2/171) of patients while the contamination rate was 1.8 % (3/171). Doctors altered antibiotics based on blood culture results in only one patient.
CONCLUSIONS: Both the yield and the impact of blood culture results on the adjustment of empiric antibiotic treatment were very small. There was a high contamination rate. The recommended practice of performing blood cultures in all children admitted with CAP should be reviewed.
METHODS: Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance.
RESULTS: Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method.
CONCLUSION: This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients.
KEY POINTS: • Clinical experience on liver thermal ablation using CT-guided robotic system is reported. • The technical success, radiation dose, safety and performance level were assessed. • Thermal ablations were successfully performed, with an average performance score of 4.4/5.0. • Robotic-assisted ablation can potentially increase capabilities of less skilled interventional radiologists. • Cost-effectiveness needs to be proven in further studies.