METHODOLOGY: Data for the study, consisting of 2553 older adults aged 60 years and older, were drawn from a nationwide household survey entitled "Determinants of Wellness among Older Malaysians: A Health Promotion Perspective" conducted in 2010.
RESULTS: Current smokers had lower rates of cognitive impairment compared to never smokers (17.4% vs 25.9%), while cognitive function in former or ex-smokers was almost similar to that of the never smokers. Findings from multiple logistic regression analysis showed that current smokers were 37% less likely to be cognitively impaired, compared to the never smokers (odds ratio [OR] = .63; 95% confidence interval [CI]: .46-.86) while controlling for potential confounders. No difference in cognitive function was observed between former smokers and never smokers (OR = .94; 95% CI: .71-1.25).
CONCLUSION: Although the findings indicated a negative association between cigarette smoking and cognitive impairment, we are unable to conclude whether this relationship is causal or affected by other unmeasured confounding factors, especially survival bias.
DESIGN: Cross sectional reliability study.
SETTING: University teaching hospital.
METHODS: Fifty healthy volunteers and 50 voice disorder patients had supervised recordings in a quiet room using OperaVOX by the iPod's internal microphone with sampling rate of 45 kHz. A five-seconds recording of vowel/a/was used to measure fundamental frequency (F0), jitter, shimmer and noise-to-harmonic ratio (NHR). All healthy volunteers and 21 patients had a second recording. The recorded voices were also analysed using the MDVP. The inter- and intrasoftware reliability was analysed using intraclass correlation (ICC) test and Bland-Altman (BA) method. Mann-Whitney test was used to compare the acoustic parameters between healthy volunteers and patients.
RESULTS: Nine of 50 patients had severe aperiodic voice. The ICC was high with a confidence interval of >0.75 for the inter- and intrasoftware reliability except for the NHR. For the intersoftware BA analysis, excluding the severe aperiodic voice data sets, the bias (95% LOA) of F0, jitter, shimmer and NHR was 0.81 (11.32, -9.71); -0.13 (1.26, -1.52); -0.52 (1.68, -2.72); and 0.08 (0.27, -0.10). For the intrasoftware reliability, it was -1.48 (18.43, -21.39); 0.05 (1.31, -1.21); -0.01 (2.87, -2.89); and 0.005 (0.20, -0.18), respectively. Normative data from the healthy volunteers were obtained. There was a significant difference in all acoustic parameters between volunteers and patients measured by the Opera-VOX (P