Affiliations 

  • 1 Department of Optometry, Faculty of Health Sciences, National University of Malaysia, Kuala Lumpur, Malaysia
Clin Exp Optom, 2004 Nov;87(6):386-9.
PMID: 15575812 DOI: 10.1111/j.1444-0938.2004.tb03099.x

Abstract

PURPOSE: Non-linear regression analysis was used to determine dark adaptation indices in people with retinitis pigmentosa and in control subjects.
METHODS: Dark adaptation data were collected for 13 people with retinitis pigmentosa and 21 controls using the Goldmann-Weekers Dark Adaptometer. Data were analysed using an exponential non-linear regression model and dark adaptation indices derived. The results were compared to age-related values.
RESULTS: The mean cone threshold of the group with RP (4.73 +/- 0.19 log units) was significantly greater than that found in the control group (3.69 +/- 0.12 log units). The rate of cone dark adaptation in the RP group was not significantly different from that of the control group. The a break in the RP group (6.46 +/- 0.70 minutes) was delayed when compared to the control group (4.29 +/- 0.21 minutes) and the rate of rod dark adaptation in the RP group was slower (10 +/- 2 per cent per minute) than that of the control group (15 +/- 1 per cent per minute).
CONCLUSIONS: This study has shown that a relatively simple data analysis can provide a more quantitative and intuitive description of dark adaptation rates in people with retinal disease. This technique will enable more effective use of dark adaptometry as a supplement to objective electrophysiology, when monitoring people with retinitis pigmentosa.
Study site: Retinitis Pigmentosa Society of NSW, the National Foundation of Blind Citizens in New South Wales and the Low Vision Clinic of the School of Optometry University of NSW, Australia

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.