Displaying publications 1 - 20 of 39 in total

Abstract:
Sort:
  1. Acar Y, Tezel O, Salman N, Cevik E, Algaba-Montes M, Oviedo-García A, et al.
    Crit Ultrasound J, 2016 Sep;8(Suppl 1):12.
    PMID: 27604617 DOI: 10.1186/s13089-016-0046-8
    TABLE OF CONTENTS: A1 Point-of-care ultrasound examination of cervical spine in emergency departmentYahya Acar, Onur Tezel, Necati SalmanA2 A new technique in verifying the placement of a nasogastric tube: obtaining the longitudinal view of nasogastric tube in addition to transverse view with ultrasoundYahya Acar, Necati Salman, Onur Tezel, Erdem CevikA3 Pseudoaneurysm of the femoral artery after cannulation of a central venous line. Should we always use ultrasound in these procedures?Margarita Algaba-Montes, Alberto Oviedo-García, Mayra Patricio-BordomásA4 Ultrasound-guided supraclavicular subclavian vein catheterization. A novel approach in emergency departmentMargarita Algaba-Montes, Alberto Oviedo-García, Mayra Patricio-BordomásA5 Clinical ultrasound in a septic and jaundice patient in the emergency departmentMargarita Algaba-Montes, Alberto Oviedo-García, Mayra Patricio-BordomásA6 Characterization of the eyes in preoperative cataract Saudi patients by using medical diagnostic ultrasoundMustafa Z. Mahmoud, Abdelmoneim SuliemanA7 High-frequency ultrasound in determining the causes of acute shoulder joint painMustafa Z. MahmoudA8 Teaching WINFOCUS Ultrasound Life Support Basic Level 1 for Providers in resource-limited countriesAbbas Ali, Alrayah Mustafa, Ihab Abdelrahman, Mustafa Bahar, Osama Ali, H. Lester Kirchner, Gregor ProsenA9 Changes of arterial stiffness and endothelial function during uncomplicated pregnancyAjda Anzic, Paul LeesonA10 Cardiovascular haemodynamic properties before, during and after pregnancyAjda Anzic, Paul LeesonA11 An old man with generalized weaknessMaryam Bahreini, Fatemeh RasooliA12 Ultrasonography for non-specific presentations of abdominal painMaryam Bahreini, Houman HosseinnejadA13 Introduction of a new imaging guideline for suspected renal colic in the emergency department: effect on CT Urogram utilisationGabriel Blecher, Robert Meek, Diana Egerton-WarburtonA14 Transabdominal ultrasound screening for pancreatic cancer in Croatian military veterans: a retrospective analysis from the first Croatian veteran's hospitalEdina Ćatić Ćuti, Stanko Belina, Tihomir Vančina, Idriz KovačevićA15 The challenge of AAA: unusual case of obstructive jaundiceEdina Ćatić Ćuti, Nadan RustemovićA16 Educational effectiveness of easy-made new simulator model for ultrasound-guided procedures in pediatric patients: vascular access and foreign body managementIkwan Chang, Jin Hee Lee, Young Ho Kwak, Do Kyun KimA17 Detection of uterine rupture by point-of-care ultrasound at emergency department: a case reportChi-Yung Cheng, Hsiu-Yung Pan, Chia-Te KungA18 Abdominal probe in the hands of interns as a relevant diagnostic tool in revealing the cause of heart failureEla Ćurčić, Ena Pritišanac, Ivo Planinc, Marijana Grgić Medić, Radovan RadonićA19 Needs assessment of the potential utility of point-of-care ultrasound within the Zanzibar health systemAbiola Fasina, Anthony J. Dean, Nova L. Panebianco, Patricia S. HenwoodA20 Ultrasonographic diagnosis of tracheal compressionOliviero Fochi, Moreno Favarato, Ezio BonanomiA21 The role of ultrasound in the detection of lung infiltrates in critically ill patients: a pilot studyMarijana Grgić Medić, Ivan Tomić, Radovan RadonićA22 The SAFER Lasso; a novel approach using point-of-care ultrasound to evaluate patients with abdominal complaints in the emergency departmentYoungrock Ha, Hongchuen TohA23 Awareness and use of clinician-performed ultrasound among clinical clerkship facultyElizabeth Harmon, Wilma Chan, Cameron Baston, Gail Morrison, Frances Shofer, Nova Panebianco, Anthony J. DeanA24 Clinical outcomes in the use of lung ultrasound for the diagnosis of pediatric pneumoniasAngela Hua, Sharon Kim, James TsungA25 Effectiveness of ultrasound in hypotensive patientsIsa Gunaydin, Zeynep Kekec, Mehmet Oguzhan AyA26 Moderate-to-severe left ventricular ejection fraction related to short-term mortality of patients with post-cardiac arrest syndrome after out-of-hospital cardiac arrestJinjoo Kim, Jinhyun Kim, Gyoosung Choi, Dowon ShimA27 Usefulness of abdominal ultrasound for acute pyelonephritis diagnosis after kidney transplantationJi-Han LeeA28 Lung ultrasound for assessing fluid tolerance in severe preeclampsiaJana Ambrozic, Katja Prokselj, Miha LucovnikA29 Optic nerve sheath ultrasound in severe preeclampsiaGabrijela Brzan Simenc, Jana Ambrozic, Miha LucovnikA30 Focused echocardiography monitoring in the postoperative period for non-cardiac patientsAsta Mačiulienė, Almantas Maleckas, Algimantas Kriščiukaitis, Vytautas Mačiulis, Andrius MacasA31 POCUS-guided paediatric upper limb fracture reduction: algorithm, tricks, and tipsSharad MohiteA32 Point-of-care lung ultrasound: a good diagnostic tool for pneumonia in a septic patientZoltan Narancsik, Hugon MožinaA33 A case of undergraduate POCUS (r)evolutionSara Nikolić, Jan Hansel, Rok Petrovčič, Una Mršić, Gregor ProsenA34 The Graz Summer School for ultrasound: from first contact to bedside application: three-and-a-half-day undergraduate ultrasound training: résumé after two years of continuous developmentSimon Orlob, Markus Lerchbaumer, Niklas Schönegger, Reinhard KaufmannA35 Usefulness of point-of-care ultrasound in the emergency room in a patient with acute abdominal painAlberto Oviedo-García, Margarita Algaba-Montes, Mayra Patricio-BordomásA36 Use of bedside ultrasound in a critically ill patient. A case reportAlberto Oviedo-García, Margarita Algaba-Montes, Mayra Patricio-BordomásA37 Diagnostic yield of clinical echocardiography for the emergency physicianAlberto Oviedo-García, Margarita Algaba-Montes, Mayra Patricio-BordomásA38 Focused cardiac ultrasound in early diagnosis of type A aortic dissection with atypical presentationChun-I Pan, Hsiu-Yung Pan, Chien-Hung WuA39 Detection of imperforated hymen by point-of-care ultrasoundHsiu-yung Pan, Chia-Te KungA40 Developing a point-of-care ultrasound curriculum for pediatric nurse practitioners practicing in the pediatric emergency departmentSarah Pasquale, Stephanie J. Doniger, Sharon Yellin, Gerardo ChiricoloA41 Use of transthoracic echocardiography in emergency setting: patient with mitral valve abscessMaja Potisek, Borut Drnovšek, Boštjan LeskovarA42 A young man with syncopeFatemeh Rasooli, Maryam BahreiniA43 Work-related repetitive use injuries in ultrasound fellowsKristine Robinson, Clara Kraft, Benjamin Moser, Stephen Davis, Shelley Layman, Yusef Sayeed, Joseph MinardiA44 Lung ultrasonography in the evaluation of pneumonia in childrenIrmina Sefic Pasic, Amra Dzananovic, Anes Pasic, Sandra Vegar ZubovicA45 Central venous catheter placement with the ultrasound aid: two years' experience of the Interventional unit, Division of Intensive Care Medicine, KBC ZagrebAna Godan Hauptman, Marijana Grgic Medic, Ivan Tomic, Ana Vujaklija Brajkovic, Jaksa Babel, Marina Peklic, Radovan RadonicA46 Duplicitas casui: two patients admitted due to acute liver failureVedran Radonic, Ivan Tomic, Luka Bielen, Marijana Grgic MedicA47 A pilot survey on an understanding of Bedside Point-of-Care Ultrasound (POCUS) among medical doctors in internal medicine: exposure, perceptions, interest, and barriers to trainingPeh Wee MingA48 Unusual case of defecation syncopeNur hafiza Yezid, Fatahul Laham MohammedA49 A case report of massive pulmonary embolism; a multidisciplinary approachZainal Abidin Huda, Wan Nasarudin Wan Ismail, W.Yus Haniff W.Isa, Hashairi Fauzi, Praveena Seeva, Mohd Zulfakar Mazlan.
  2. Usman F, Dennis JO, Meriaudeau F, Ahmed AY, Seong KC, Fen YW, et al.
    Molecules, 2020 Sep 25;25(19).
    PMID: 32992942 DOI: 10.3390/molecules25194414
    The optical constants of Para-Toluene sulfonic acid-doped polyaniline (PANI), PANIchitosan composites, PANI-reduced graphene-oxide composites and a ternary composite comprising of PANI, chitosan and reduced graphene-oxide dispersed in diluted p-toluene sulfonic acid (PTSA) solution and N-Methyl-2-Pyrrolidone (NMP) solvent have been evaluated and compared. The optical constant values were extracted from the absorbance spectra of thin layers of the respective samples. The potential utilization of the materials as the active sensing materials of surface plasmon resonance biosensors has also been assessed in terms of the estimated value of the penetration depth through a dielectric medium. The results show a reasonable dependence of the optical constant parameters on the solvent type. Higher real part refractive index (n) and real part complex dielectric permittivity (ε') values were observed for the samples prepared using PTSA solution, while higher optical conductivity values were observed for the NMP-based samples due to their relatively higher imaginary part refractive index (k) and imaginary part complex dielectric permittivity (ε″) values. In addition, NMP-based samples show improvement in terms of the penetration depth through a dielectric medium by around 9.5, 1.6, 4.4 and 2.9 times compared to PTSA-based samples for the PANI, PANI-chitosan, PANI-RGO and the ternary composites, respectively. Based on these, it is concluded that preparation of these materials using different dispersion solvents could produce materials of different optical properties. Thus, the variation of the dispersion solvent will allow the flexible utilization of the PANI and the composites for diverse applications.
  3. Alnaaimi M, Sulieman A, Tamam N, Alkhorayef M, Alduaij M, Mohammedzein T, et al.
    Appl Radiat Isot, 2021 Dec;178:109965.
    PMID: 34688024 DOI: 10.1016/j.apradiso.2021.109965
    The positron emitters (18F-Sodium Fluoride (NaF)) and X-rays used in Positron emission tomography (PET) combined with computed tomography (PET/CT) imaging have a high radiation dose, which results in a high patient dose. The present research intends to determine the radiation dose and risks associated with PET/CT- 18F-Sodium fluoride examinations in patients. The 18F-NaF PET/CT was used to investigate the doses of 86 patients. Patient exposure parameters and ImPACT software were used to calculate mean effective doses. The administered activity of 185 MBq (5.0 mCi) per procedure has a mean and range based on the patient's BMI (BMI). The range of patient effective doses per procedure was found to be 4-10 mSv, with a radiation risk of 1 × 10-5 per procedure. Patient doses are determined by the patient's size, scanner type, imaging protocol, and reconstruction method. For further dose reduction, proper justification and radiation dose optimization is required.
  4. Abedin MJ, Khandaker MU, Uddin MR, Karim MR, Uddin Ahamad MS, Islam MA, et al.
    Chemosphere, 2022 Jun;297:134022.
    PMID: 35202672 DOI: 10.1016/j.chemosphere.2022.134022
    This study investigates the Covid-19 driven indiscriminate disposal of PPE wastes (mostly face mask and medical wastes) in Chittagong metropolitan area (CMA), Bangladesh. Based on the field monitoring, the mean PPE density (PPE/m2± SD) was calculated to be 0.0226 ± 0.0145, 0.0164 ± 0.0122, and 0.0110 ± 0.00863 for July, August, and September 2021, respectively (during the peak time of Covid-19 in Bangladesh). Moreover, gross information on PPE waste generation in the city was calculated using several parameters such as population density, face mask acceptance rate by urban population, total Covid-19 confirmed cases, quarantined and isolated patients, corresponding medical waste generation rate (kg/bed/day), etc. Moreover, the waste generated due to face mask and other PPEs in the CMA during the whole Covid-19 period (April 4, 2020 to September 5, 2021) were calculated to be 64183.03 and 128695.75 tons, respectively. It has been observed that the negligence of general people, lack of awareness about environmental pollution, and poor municipal waste management practices are the root causes for the contamination of the dwelling environment by PPE wastes. As a result, new challenges have emerged in solid waste management, which necessitates the development of an appropriate waste management strategy. The ultimate policies and strategies may help to achieve the SDG goals 3, 6, 11, 12, 13, and 15, and increase public perception on the use and subsequent disposal of PPEs, especially face masks.
  5. Bose R, Jayawant M, Raut R, Lakkakula J, Roy A, Alghamdi S, et al.
    Front Pharmacol, 2023;14:1218867.
    PMID: 37601050 DOI: 10.3389/fphar.2023.1218867
    The field of cancer nanotheranostics is rapidly evolving, with cyclodextrin (CD)-based nanoparticles emerging as a promising tool. CDs, serving as nanocarriers, have higher adaptability and demonstrate immense potential in delivering powerful anti-cancer drugs, leading to promising and specific therapeutic outcomes for combating various types of cancer. The unique characteristics of CDs, combined with innovative nanocomplex creation techniques such as encapsulation, enable the development of potential theranostic treatments. The review here focuses mainly on the different techniques administered for effective nanotheranostics applications of CD-associated complex compounds in the domain of cancer treatments. The experimentations on various loaded drugs and their complex conjugates with CDs prove effective in in vivo results. Various cancers can have potential nanotheranostics cures using CDs as nanoparticles along with a highly efficient process of nanocomplex development and a drug delivery system. In conclusion, nanotheranostics holds immense potential for targeted drug delivery and improved therapeutic outcomes, offering a promising avenue for revolutionizing cancer treatments through continuous research and innovative approaches.
  6. Isinkaye MO, OlaOlorun OA, Chandrasekaran A, Adekeye AS, Dada TE, Tamilarasi A, et al.
    Heliyon, 2023 Nov;9(11):e22451.
    PMID: 38034673 DOI: 10.1016/j.heliyon.2023.e22451
    Assessment of activity levels of radionuclides that exist in soil, granite, and charnockite rock samples is very crucial because it exhibits an enhanced elemental concentration of uranium (U) and thorium (Th) contributing higher natural background activity than usual in the environment and it may cause health risk to human health through the external and internal exposure. This study determined the radioactivity levels of 238U, 232Th, and 40K radionuclides in soil, granite, and charnockite rock samples collected from selected fields in Ekiti State, Nigeria using Caesium iodide CsI(Tl) scintillation gamma spectrometer. It also evaluated indices of the radiological parameters consisting of radium equivalent activity (Raeq), absorbed dose rate (DR), annual effective dose equivalent (AEDE), internal hazard index (Hin), and excess lifetime cancer risk (ELCR). The calculated average activity concentrations of 238U, 232Th, and 40K are 30.40 ± 0.71 Bq kg-1, 3.31 ± 0.05 Bq kg-1, and 222.25 ± 14.72 Bq kg-1, respectively, which were lower than their respective world average values. Comparatively, potassium concentrations in these collected samples have a higher value than concentrations of uranium and thorium (40K > 238U > 232Th). All the evaluated values of the radiological parameters (except DR) of the appraised radionuclides were below the global permissible limits. The granite rocks, charnockite rocks, and soils from Ekiti State in Nigeria do not pose any hazardous risk to humans, but continued monitoring is necessary when these materials are used as building materials, which cause long-term radiation exposure.
  7. Zango ZU, Lawal MA, Usman F, Sulieman A, Akhdar H, Eisa MH, et al.
    Chemosphere, 2024 Mar;351:141218.
    PMID: 38266876 DOI: 10.1016/j.chemosphere.2024.141218
    The widespread consumption of pharmaceutical drugs and their incomplete breakdown in organisms has led to their extensive presence in aquatic environments. The indiscriminate use of antibiotics, such as sulfonamides, has contributed to the development of drug-resistant bacteria and the persistent pollution of water bodies, posing a threat to human health and the safety of the environment. Thus, it is paramount to explore remediation technologies aimed at decomposing and complete elimination of the toxic contaminants from pharmaceutical wastewater. The review aims to explore the utilization of metal-oxide nanoparticles (MONPs) and graphitic carbon nitrides (g-C3N4) in photocatalytic degradation of sulfonamides from wastewater. Recent advances in oxidation techniques such as photocatalytic degradation are being exploited in the elimination of the sulfonamides from wastewater. MONP and g-C3N4 are commonly evolved nano substances with intrinsic properties. They possessed nano-scale structure, considerable porosity semi-conducting properties, responsible for decomposing wide range of water pollutants. They are widely applied for photocatalytic degradation of organic and inorganic substances which continue to evolve due to the low-cost, efficiency, less toxicity, and more environmentally friendliness of the materials. The review focuses on the current advances in the application of these materials, their efficiencies, degradation mechanisms, and recyclability in the context of sulfonamides photocatalytic degradation.
  8. Zango ZU, Jumbri K, Sambudi NS, Ramli A, Abu Bakar NHH, Saad B, et al.
    Polymers (Basel), 2020 Nov 10;12(11).
    PMID: 33182825 DOI: 10.3390/polym12112648
    Water-borne emerging pollutants are among the greatest concern of our modern society. Many of these pollutants are categorized as endocrine disruptors due to their environmental toxicities. They are harmful to humans, aquatic animals, and plants, to the larger extent, destroying the ecosystem. Thus, effective environmental remediations of these pollutants became necessary. Among the various remediation techniques, adsorption and photocatalytic degradation have been single out as the most promising. This review is devoted to the compilations and analysis of the role of metal-organic frameworks (MOFs) and their composites as potential materials for such applications. Emerging organic pollutants, like dyes, herbicides, pesticides, pharmaceutical products, phenols, polycyclic aromatic hydrocarbons, and perfluorinated alkyl substances, have been extensively studied. Important parameters that affect these processes, such as surface area, bandgap, percentage removal, equilibrium time, adsorption capacity, and recyclability, are documented. Finally, we paint the current scenario and challenges that need to be addressed for MOFs and their composites to be exploited for commercial applications.
  9. Tamam N, Sulieman A, Omer H, Toufig H, Alsaadi M, Salah H, et al.
    Appl Radiat Isot, 2022 Dec;190:110452.
    PMID: 36183658 DOI: 10.1016/j.apradiso.2022.110452
    CT scanning deliver much higher radiation doses than planar radiological procedures, which puts patients to high risks. This study measures and evaluates patient doses during chest and abdomen computed tomography procedures. Particular attention is given to measuring the dose to the equivalent breast (mSv) and to estimate the associated risks of breast cancer to young female patients (15-35 years). Data was obtained from standard examinations from three hospitals. The measured values of CT dose indexes, CTDI (mGy) as well as exposure-related parameters were used for assessment. Breast and effective doses were extrapolated using a software. The results showed remarkable variations of the mean organ equivalent doses for similar CT examinations in the studied hospitals. This could be attributed to the variation in CT scanning imaging technique, and clinical indications. The average effective dose to the chest was 7.9 mSv (2.3-47.0 mSv) and for the abdomen the mean dose was 6.6 mSv, ranging from (3.3-27 mSv). The breast received equivalent doses from chest and abdomen procedures as follows: 10.2 (1.6-33 mSv) and 10.1(2.3-19 mS) Sv respectively. Each procedure yielded high risks of breast cancer for young females. Implementation of accurate referral criteria is recommended to avoid unnecessary breast radiation exposure.
  10. Osman H, Raafat BM, Faizo NL, Ahmed RM, Alamri S, Alghamdi AJ, et al.
    Appl Radiat Isot, 2021 Nov 27;180:110049.
    PMID: 34864437 DOI: 10.1016/j.apradiso.2021.110049
    The current study was aimed to estimate the entrance surface air kerma (ESAK, mGy) for adult patients undergoing conventional radiography of Anteroposterior pelvis examination, and finally to establish a local diagnostic reference level (DRL). A total of 500 patients were exposed to diagnostic radiation in four hospitals (coded A, B, C, and D) in Taif and Kharaj city, Saudi Arabia, with different X-ray equipment specifications. Patient demographic data like age (y), body mass index (BMI) in kg/m2 as well as exposure factors and X-ray tube output were recorded. ESAK (mGy) was first calculated using the exposure data and tube output values, then the ESAK values were used to estimate entrance surface dose (ESD). The average BMI was 23.9 kg/m2. The mean tube potential used in A, B, C, and D hospitals and the corresponding estimated ESD were found to be 74.2, 69.8, 73, 76,7 kVp, and 2.54, 2.64, 2.94, 3.03 mGy respectively. The correlation coefficient between ESAK and BMI was found to be 0.98. When compared to computed radiography (CR), the conventional X-ray digital radiography reduces the radiation exposure in pelvic imaging by a factor of 1.18. The third quartile of median proposed a lower than the DRL of the previous studies.
  11. Aamry A, Sulieman A, Tamam N, Abuhadi NH, Johary Y, Aamri H, et al.
    Appl Radiat Isot, 2022 Mar;181:110097.
    PMID: 35063867 DOI: 10.1016/j.apradiso.2022.110097
    Staff occupational radiation exposure is limited to 20 mSv annually to preclude tissue reaction and lower risk of cancer effect. Staff occupational exposure arises during the preparation, injection, and scanning of the patients. Recent studies reported that nuclear medicine personnel might exceed the annual dose limit in high workload and poor radiation protection circumstances. Therefore, an accurate estimation of the annual dose limit is recommended. The goal of this research is to calculate the cumulative external effective dose (mSv) per year for nuclear medicine physicians, technologists, and nurses at SPECT/CT department. A total of 15 staff worked in the nuclear medicine department at King Saud Medical City (KSMC), Riyadh, Saudi Arabia were evaluated for the last six years. 99mTc is used more frequently for most of the patients. The procedures include renal, cardiac scintigraphy procedures. Staff dose was quantified using calibrated thermoluminecnt dosimeters (TLD-100) with an automatic TLD reader (Harshaw 6600). Exposure to ionizing radiation was evaluated in terms of deep doses (Hp(10) were evaluated. The overall average and standard deviation of the external doses for nuclear medicine physicians, technologists' and nurses were 1.8 ± 0.7, 1.9 ± 0.6, 2.0 ± 0.9, 2.2 ± 0.8, 6.0 ± 2.8, and 3.6 ± 1.3 for the years 2015,2016,2017,2018,2019, and 2020, respectively. Technologists and nurses received higher doses of compared to the nuclear medicine physicians. Technologists and nurses involved in radionuclide preparation, patients' injection, and image acquisition. Staff annual exposure is below the annual dose limits; however, this external dose is considered high compared to the current workload.
  12. Johary YH, Albarakati S, AlSohaim A, Aamry A, Aamri H, Tamam N, et al.
    Appl Radiat Isot, 2023 Mar;193:110648.
    PMID: 36669265 DOI: 10.1016/j.apradiso.2023.110648
    Occupational radiation exposure can occur due to various human activities, including the use of radiation in medicine. Occupationally exposed personnel surpassing 7.4 millions, and respresent the biggest single group of employees who are exposed to artificial radiation sources at work. This study compares the occupational radiation dose levels for 145 workers in four different hospitals located in the Aseer region in Saudi Arabia. The occupational exposure was quantified using thermoluminescence dosimeters (TLD-100). The levels of annual occupational exposures in targeted hospitals were calculated and compared with the levels of the international atomic energy agency (IAEA) Safety Standards. An average yearly cumulative dose for the two consecutive years. The average, highest and lowest resulted occupational doses under examination in this work is 1.42, 3.9 mSv and 0.72 for workers in various diagnostic radiology procedures. The resulted annual effective dose were within the IAEA approved yearly dose limit for occupational exposure of workers over 18, which is 20 mSv. Staff should be monitored on a regular basis, according to current practice, because their annual exposure may surpass 15% of the annual effective doses.
  13. Abedin MJ, Khandaker MU, Uddin MR, Karim MR, Ahamad MSU, Islam MA, et al.
    Environ Sci Pollut Res Int, 2022 Apr;29(18):27521-27533.
    PMID: 34981371 DOI: 10.1007/s11356-021-17859-8
    The present study focuses on the indiscriminate disposal of personal protective equipment (PPEs) and resulting environmental contamination during the 3rd wave of COVID-19-driven global pandemic in the Chittagong metropolitan area, Bangladesh. Because of the very high rate of infection by the delta variant of this virus, the use of PPEs by the public is increased significantly to protect the ingestion/inhalation of respiratory droplets in the air. However, it is a matter of solicitude that general people throw away the PPEs to the dwelling environment unconsciously. With the increase of inappropriate disposal of PPEs (i.e., mostly the disposable face masks made from plastic microfibers), the possibility of transmission of the virus to the general public cannot be neglected completely. This is because this virus can survive for several days on the inanimate matter like plastics and fibers. At the same time, the result of environmental contamination by microplastic/microfiber has been widespread which eventually creates the worst impact on ecosystems and organisms. The present results may help to increase public perception of the use and subsequent disposal of PPEs, especially the face masks.
  14. Khandaker MU, Chijioke NO, Heffny NAB, Bradley DA, Alsubaie A, Sulieman A, et al.
    Foods, 2021 Feb 10;10(2).
    PMID: 33578933 DOI: 10.3390/foods10020381
    While the consumption of seaweed and seaweed-based products is very common amongst East Asian nations, forming a notable component of the daily diet, relatively very few studies have concerned the concentrations of heavy metals in these together with potential effects on human health. The present study analyses the concentrations of 17 elements in locally resourced seaweed, also assessing potential noncarcinogenic and carcinogenic risks. The samples were ground, homogenized, and quantified using the ICP-OES technique. It has been found that the essential elements K, Ca, Mg, Zn, and Na typically show concentrations somewhat greater than a number of potentially toxic metals, in particular, Cd, Pb, Ag, and As, with exceptions being Ni, Cr-VI, and Si. Statistical analysis indicates all of the latter to have similar origin, with increased concentration of these metals within the marine ecosystem. While the daily estimated intake of most metals is seen to be within the daily dietary allowance level recommended by various international organizations, the noncarcinogenic risk shows a value greater than unity, estimated via the hazard quotient. This indicates a potential for adverse effects to health arising from consumption of the sampled seaweed. The carcinogenic risk resulting from nonessential elements shows values greater than the United States Environmental Protection Agency (US-EPA) reference limit of 10-4. Considering the nonbiodegradability of heavy metals and metalloids and their potential accumulation in seaweed, there is need for critical examination of metal levels in the seaweeds obtained from the present study locations, together with the introduction of practices of removal of heavy metals via bio-adsorbent techniques.
  15. Khandaker MU, Zayadi NSB, Sani SFA, Bradley DA, Osman H, Alzamil Y, et al.
    Radiat Prot Dosimetry, 2023 Nov 02;199(18):2174-2178.
    PMID: 37934995 DOI: 10.1093/rpd/ncad179
    Present study concerns the radiological character of Malaysian honey. A total of 18 samples (representative of the various most common types) were obtained from various honey bee farms throughout the country. Using a high-purity germanium γ-ray spectroscopic system, the samples were analysed for the naturally occurring radionuclides 226Ra, 228Ra and 40K. The respective range of activities (in Bq/kg) was: 3.49 ± 0.35 to 4.51 ± 0.39, 0.99 ± 0.37 to 1.74 ± 0.39 and 41.37 ± 3.26 to 105.02 ± 6.91. The estimated associated committed effective doses were derived from prevailing data on national consumption of honey, the annual dose being found low compared with the UNSCEAR reference dose limit of 290 μSv y-1. The estimated threshold consumption rate for honey indicates a maximum intake of 339 g/d, which poses an insignificant radiological risk to public health; however, the total dietary exposure may not, the guidance level of 290 μSv y-1 being applicable to dietary intake of all foodstuffs. The study is in support of the cultivation of a healthy lifestyle, acknowledging prevailing radioactivity within the environment.
  16. Usman F, Dennis JO, Mkawi EM, Al-Hadeethi Y, Meriaudeau F, Fen YW, et al.
    Polymers (Basel), 2020 Nov 04;12(11).
    PMID: 33158093 DOI: 10.3390/polym12112586
    To non-invasively monitor and screen for diabetes in patients, there is need to detect low concentration of acetone vapor in the range from 1.8 ppm to 5 ppm, which is the concentration range of acetone vapor in diabetic patients. This work presents an investigation for the utilization of chitosan-polyethylene glycol (PEG)-based surface plasmon resonance (SPR) sensor in the detection of trace concentration acetone vapor in the range of breath acetone in diabetic subjects. The structure, morphology, and elemental composition of the chitosan-PEG sensing layer were characterized using FTIR, UV-VIS, FESEM, EDX, AFM, and XPS methods. Response testing was conducted using low concentration of acetone vapor in the range of 0.5 ppm to 5 ppm using SPR technique. All the measurements were conducted at room temperature and 50 mL/min gas flow rate. The sensor showed good sensitivity, linearity, repeatability, reversibility, stability, and high affinity toward acetone vapor. The sensor also showed better selectivity to acetone compared to methanol, ethanol, and propanol vapors. More importantly, the lowest detection limit (LOD) of about 0.96 ppb confirmed the applicability of the sensor for the non-invasive monitoring and screening of diabetes.
  17. Alkhorayef M, Sulieman A, Alzahrani K, Abuzaid M, Alomair OI, Almuwannis M, et al.
    Appl Radiat Isot, 2021 Feb;168:109520.
    PMID: 33307438 DOI: 10.1016/j.apradiso.2020.109520
    The various technological advancements in computed tomography (CT) have resulted in remarkable growth in the use of CT imaging in clinical practice, not the least of which has been its establishment as the most valuable imaging examination for the assessment of cardiovascular system disorders. The objective of this study was to assess the effective radiation dose and radiation risk for patients during cardiac CT procedures, based on studies from four different hospitals equipped with 128 slice CT equipment. A total of eighty-three patients were investigated in this study with different clinical indications. Effective doses were also calculated using software based on Monte Carlo simulation. The mean patient age (years), weight (kg), and body mass index (BMI (kg/m2)) were 49 ± 11, 82 ± 12, and 31 ± 6, respectively. The results of the study revealed that the tube voltage (kVp) and tube current-exposure time product (mAs) ranged between 100 to 140 and 50 to 840 respectively. The overall average patient dose values for the volume CT dose index [(CTDIvol), in mGy)] and dose length product (DLP) (in mGy·cm) were 34.8 ± 15 (3.7-117.0) and 383.8 ± 354 (46.0-3277.0) respectively. The average effective dose (mSv) was 15.2 ± 8 (1.2-61.8). The radiation dose values showed wide variation between different hospitals and even within the same hospital. The results indicate the need to optimize radiation dose and to establish diagnostic reference levels (DRLs) for patients undergoing coronary computed tomography angiography (CCTA), also to harmonize the imaging protocols to ensure reduced radiation risk.
  18. Ali SKI, Khandaker MU, Al-Mugren KS, Latif SA, Bradley DA, Okhunov AA, et al.
    Appl Radiat Isot, 2021 Jul;173:109735.
    PMID: 33915407 DOI: 10.1016/j.apradiso.2021.109735
    Copper-67 (T1/2 = 61.83 h, Eβ-mean=141 keV, Iβ-total=100%; Eγ = 184.577 keV, Iγ = 48.7%) is a promising radionuclide for theranostic applications especially in radio immunotherapy. However, one of the main drawbacks for its application is related to its limited availability. Various nuclear reaction routes investigated in the last years can result in 67Cu production, although the use of proton beams is the method of choice taken into account in this work. The goal of this work is a revision of the cross-sections aimed at 67Cu yield, which were evaluated for the 68Zn(p,2p)67Cu reaction route up to 80 MeV proton energy. A well-defined statistical procedure, i.e., the Simultaneous Evaluation on KALMAN (SOK), combined with the least-squares concept, was used to obtain the evaluated data together with the covariance matrix. The obtained evaluated data were also compared to predictions provided by the nuclear reaction model codes TALYS and EMPIRE, and a partial agreement among them has been found. These data may be useful for both existing and potential applications in nuclear medicine, to achieve an improvement and validation of the various nuclear reaction models, and may also find applications in other fields (e.g., activation analysis and thin layer activation).
  19. Sulieman A, Mayhoub FH, Salah H, Al-Mohammed HI, Alkhorayef M, Moftah B, et al.
    Appl Radiat Isot, 2020 Oct;164:109240.
    PMID: 32819499 DOI: 10.1016/j.apradiso.2020.109240
    Lutetium-177 (DOTATATE) (177Lu; T1/2 6.7 days), a labelled β- and Auger-electron emitter, is widely used in treatment of neuroendocrine tumours. During performance of the procedure, staff and other patients can potentially receive significant doses in interception of the gamma emissions [113 keV (6.4%) and 208 keV (11%)] that are associated with the particle decays. While radiation protection and safety assessment are required in seeking to ensure practices comply with international guidelines, only limited published studies are available. The objectives of present study are to evaluate patient and occupational exposures, measuring ambient doses and estimating the radiation risk. The results, obtained from studies carried out in Riyadh over an 11 month period, at King Faisal Specialist Hospital and Research Center, concerned a total of 33 177Lu therapy patients. Patient exposures were estimated using a calibrated Victoreen 451P survey meter (Fluke Biomedical), for separations of 30 cm, 100 cm and 300 cm, also behind a bed shield that was used during hospitalization of the therapy patients. Occupational and ambient doses were also measured through use of calibrated thermoluminescent dosimeters and an automatic TLD reader (Harshaw 6600). The mean and range of administered activity (in MBq)) was 7115.2 ± 917.2 (4329-7955). The ambient dose at corridors outside of therapy isolation rooms was 1.2 mSv over the 11 month period, that at the nursing station was below the limit of detection and annual occupational doses were below the annual dose limit of 20 mSv. Special concern needs to be paid to comforters (carers) and family members during the early stage of radioisotope administration.
  20. Khandaker MU, Mat Nawi SN, Bradley DA, Lam SE, Abdul Sani SF, Sulieman A
    Appl Radiat Isot, 2021 Aug;174:109757.
    PMID: 33990033 DOI: 10.1016/j.apradiso.2021.109757
    This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for different diameters PPLG samples were obtained with varying temperature from 50 to 300 °C, at a fixed heating rate of 10 °Cs-1. A number of methods (initial rise, peak shape and curve fitting) were used to fit the TL glow peaks of the PPLG samples obtained under photon dose of 200 Gy. From the fitted TL signals, the trap parameters such as the order of kinetics, the activation energy, the frequency factor, etc. for the individual peaks were numerically determined. The lifetimes of TL process were calculated assuming the first-order kinetics. The results are compared among the different methods adopted in this study. Implications about the possible results in glow curve deconvolution are discussed.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links