Displaying publications 1 - 20 of 45 in total

Abstract:
Sort:
  1. Arvin B, Prepageran N, Raman R
    Indian J Otolaryngol Head Neck Surg, 2013 Dec;65(Suppl 3):480-4.
    PMID: 24427701 DOI: 10.1007/s12070-011-0356-x
    The objective of this study is to determine whether presbycusis occurs much earlier than previously believed if the high frequency (above 8 kHz) are included. Tertiary referral center (a teaching University). This is a cross-sectional observational study. Healthy adults from 20 to 49 years of age who had essentially normal hearing were included into the study. They were subjected to high frequency pure tone audiometry (until 16 kHz). Participants were grouped based on age ranges of 10 years (e.g., 20-29, 30-39, and 40-49) and the presence of symmetrical high frequency sensor neural hearing loss were documented. There is a significant presence of symmetrical high frequency sensor neural hearing loss (not attributed to any known risk factors) as early as from the age group of 40 to 49 years. Seven of 43 participants (16%) from age group of 20 to 29 years and 12 of 24 participants (50%) from age group of 30 to 39 years had significant high frequency hearing loss. High frequency hearing loss (high frequency Presbycusis) may occur much earlier than previously believed.
    Matched MeSH terms: Audiometry, Pure-Tone
  2. Lim EY, Tang IP, Peyman M, Ramli N, Narayanan P, Rajagopalan R
    Eur Arch Otorhinolaryngol, 2015 Nov;272(11):3109-13.
    PMID: 25205300 DOI: 10.1007/s00405-014-3232-y
    High acoustic noise level is one of the unavoidable side effects of 3 T magnetic resonance imaging (MRI). A case of hearing loss after 3 T MRI has been reported in this institution and hence this study. The objective of this study was to determine whether temporary threshold shift (TTS) in high frequency hearing occurs in patients undergoing 3 T MRI scans of the head and neck. A total of 35 patients undergoing head and neck 3 T MRI for various clinical indications were tested with pure tone audiometry in different frequencies including high frequencies, before and after the MRI scan. Any threshold change from the recorded baseline of 10 dB was considered significant. All patients were fitted with foamed 3 M earplugs before the procedure following the safety guidelines for 3 T MRI. The mean time for MRI procedure was 1,672 s (range 1,040-2,810). The noise dose received by each patient amounted to an average of 3,906.29% (1,415-9,170%). The noise dose was derived from a normograph used by Occupational Noise Surveys. This was calculated using the nomograph of L eq, L EX, noise dose and time. There was no statistically significant difference between the hearing threshold before and after the MRI procedures for all the frequencies (paired t test, P > 0.05). For patients using 3 M foamed earplugs, noise level generated by 3 T MRI during routine clinical sequence did not cause any TTS in high frequency hearing.
    Matched MeSH terms: Audiometry, Pure-Tone
  3. Ibrahim IA, Ting HN, Moghavvemi M
    J Int Adv Otol, 2019 Apr;15(1):87-93.
    PMID: 30924771 DOI: 10.5152/iao.2019.4553
    OBJECTIVES: This study uses a new approach for classifying the human ethnicity according to the auditory brain responses (electroencephalography [EEG] signals) with a high level of accuracy. Moreover, the study presents three different algorithms used to classify the human ethnicity using auditory brain responses. The algorithms were tested on Malays and Chinese as a case study.

    MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.

    RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.

    CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.

    Matched MeSH terms: Audiometry, Pure-Tone/methods
  4. Mukari SZS, Ishak WS, Maamor N, Wan Hashim WF
    Ann Otol Rhinol Laryngol, 2017 Oct;126(10):697-705.
    PMID: 28845678 DOI: 10.1177/0003489417727547
    OBJECTIVES: Studies in cognitive aging demonstrated inconsistent association between hearing and cognition in older adults. Furthermore, it is still unclear if hearing loss at high frequencies, which is the earliest to be affected, is associated with cognitive functioning. This study aimed to determine the association between global cognitive status and pure tone average (PTA) at 0.5, 1, and 2 kHz (PTA low) and PTA at 4 and 8 kHz (PTA high).

    METHODS: This study involved 307 adults aged 60 years and older. Participants had their hearing and cognition measured using pure tone audiometry and Mini Mental State Examination (MMSE), respectively.

    RESULTS: Pure tone average (low) accounted for significant but minimal amount of variance in measure of MMSE. Multiple regression analyses were also performed on normal and impaired hearing cohorts and cohorts with younger (60-69 years) and older (≥70 years) groups. The results revealed a significant relationship between PTA (low) and MMSE only in the younger age group. In contrast, no significant relationship was found between PTA (high) and cognition in any of the cohorts.

    CONCLUSION: Pure tone average (low) is significantly but minimally related to measure of general cognitive status. Similar relationship is not observed between high-frequency hearing and cognition. Further research using a more comprehensive cognitive test battery is needed to confirm the lack of association between high-frequency hearing and cognition.

    Matched MeSH terms: Audiometry, Pure-Tone*
  5. Krishnan G
    Med J Malaysia, 1994 Mar;49(1):44-8.
    PMID: 8057990
    The common investigations done were pure tone audiometry, electronystagmography, X-ray of the internal auditory meatus, CT-scan of the internal auditory meatus and X-ray of the cervical spine. After the examinations and investigations only 52 patients out of the 107 could be given any diagnosis. The most common diagnosis for the vertigo was Meniere's disease.
    Matched MeSH terms: Audiometry, Pure-Tone
  6. Lim CC, Misron K, Liew YT, Wong EHC
    BMJ Case Rep, 2019 Nov 04;12(11).
    PMID: 31690691 DOI: 10.1136/bcr-2019-232275
    Acoustic neuroma (AN) usually manifests with asymmetric hearing loss, tinnitus, dizziness and sense of disequilibrium. About 10% of patients complain of atypical symptoms, which include facial numbness or pain and sudden onset of hearing loss. Patients with atypical symptoms also tend to have larger tumours due to the delay in investigation. We report a particularly interesting case of a patient presented to us with numbness over her right hemifacial region after a dental procedure without significant acoustic and vestibular symptoms. Physical examination and pure tone audiometry revealed no significant findings but further imaging revealed a cerebellopontine angle mass. The changing trends with easier access to further imaging indicate that the presentation of patients with AN are also changing. Atypical symptoms which are persistent should raise clinical suspicion of this pathology among clinicians.
    Matched MeSH terms: Audiometry, Pure-Tone
  7. Goh LC, Azman A, Siti HBK, Khoo WV, Muthukumarasamy PA, Thong MK, et al.
    Int J Pediatr Otorhinolaryngol, 2018 Jun;109:50-53.
    PMID: 29728184 DOI: 10.1016/j.ijporl.2018.03.010
    OBJECTIVE: To study the audiological outcome and early screening of pre-school going children with craniosynostosis under follow-up at the University of Malaya Medical Center(UMMC), Kuala Lumpur, Malaysia over a 10 year period.

    METHODS: A retrospective descriptive cohort study on the audiological findings detected during the first hearing assessment done on a child with craniosynostosis using otoacoustic emissions, pure tone audiometry or auditory brainstem response examination. The main aim of this study was to evaluate the type and severity of hearing loss when compared between syndromic and non-sydromic craniosynostosis, and other associated contributory factors.

    RESULTS: A total of 31 patients with 62 ears consisting of 14 male patients and 17 female patients were evaluated. Twenty two patients (71%) were syndromic and 9 (29%) were non-syndromic craniosynostosis. Amongst the syndromic craniosynostosis, 9 (41%) had Apert syndrome, 7 (32%) had Crouzon syndrome, 5 (23%) had Pfieffer syndrome and 1 (4%) had Shaethre Chotzen syndrome. Patients with syndromic craniosynostosis were more likely to present with all types and severity of hearing loss, including severe to profound sensorineural hearing loss while children with non-syndromic craniosynostosis were likely to present with normal hearing (p 

    Matched MeSH terms: Audiometry, Pure-Tone
  8. Hu S, Anschuetz L, Huth ME, Sznitman R, Blaser D, Kompis M, et al.
    JMIR Res Protoc, 2019 Jan 09;8(1):e12270.
    PMID: 30626571 DOI: 10.2196/12270
    BACKGROUND: Electroencephalography (EEG) studies indicate possible associations between tinnitus and changes in the neural activity. However, inconsistent results require further investigation to better understand such heterogeneity and inform the interpretation of previous findings.

    OBJECTIVE: This study aims to investigate the feasibility of EEG measurements as an objective indicator for the identification of tinnitus-associated neural activities.

    METHODS: To reduce heterogeneity, participants served as their own control using residual inhibition (RI) to modulate the tinnitus perception in a within-subject EEG study design with a tinnitus group. In addition, comparison with a nontinnitus control group allowed for a between-subjects comparison. We will apply RI stimulation to generate tinnitus and nontinnitus conditions in the same subject. Furthermore, high-frequency audiometry (up to 13 kHz) and tinnitometry will be performed.

    RESULTS: This work was funded by the Infrastructure Grant of the University of Bern, Bern, Switzerland and Bernafon AG, Bern, Switzerland. Enrollment for the study described in this protocol commenced in February 2018. Data analysis is currently under way and the first results are expected to be submitted for publication in 2019.

    CONCLUSIONS: This study design helps in comparing the neural activity between conditions in the same individual, thereby addressing a notable limitation of previous EEG tinnitus studies. In addition, the high-frequency assessment will help to analyze and classify tinnitus symptoms beyond the conventional clinical standard.

    INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/12270.

    Matched MeSH terms: Audiometry, Pure-Tone
  9. Toh, Teck Hock, Nurhilda Abdullah, Chua, Soh Yian, Muhamad Rais Abdullah, Islia Nahazatul, Chieng, Lee Ling
    Int J Public Health Res, 2011;1(2):66-71.
    MyJurnal
    Introduction Special Olympics (SO) Inc. is an organization for people with intellectual disability (ID) to actively engaging in Olympic-type sport and participating in competition. Special Olympic Inc. provides Healthy Athletes Programme (HAP®) in screening and providing health education to Special Olympic Athletes. Objective To study the body mass index (BMI), blood pressure (BP), visual acuity and hearing status of children and young adult with ID in Special Olympics Sarawak. Methods Health data were collected by trained health professionals under HAP®held in conjunction with Special Olympics Sarawak State Games on 17th and 18th April 2010 in Sibu. Health data collected were athletes' weight, BMI, BP, ear canal screen and hearing status (oto-acoustic emission, pure tone audiometry), as well as eye health and visual acuity, using guidelines set by HAP®. Results 195 athletes attended the State Games in 2010 of which 138 were screened. Significant number of athletes was considered overweight / obese (31.5% for children and 36.9% for adult). More than 20% of the adult athletes were hypertensive or at risk of hypertension. Sixteen percent of the adult athletes had hearing loss. More than half of the adult and children athletes never had eye checks, and a significant numbers of them had abnormal eye tests results. Conclusions Health screening conducted during the HAP® is a useful screening program in this population. Health data collected can bring awareness to athletes and their family, and corrective measures in hearing and visual impairment can be taken immediately.
    Matched MeSH terms: Audiometry, Pure-Tone
  10. Singh AP, Prasad U, Kumar N
    Singapore Med J, 1983 Dec;24(6):367-73.
    PMID: 6681493
    Clinical synopsis and investigations on fourteen patients with blast injuries of the ear successfully treated at the ENT Unit of the University Hospital, Kuala Lumpur, revealed few interesting observations in addition to usual findings. The most outstanding one was the absence of sensorineural deafness, although it has been claimed as one of the most constant features. Conservative management alone was found to be of significant value.
    Matched MeSH terms: Audiometry, Pure-Tone
  11. Seluakumaran K, Shaharudin MN
    Int J Audiol, 2022 Oct;61(10):850-858.
    PMID: 34455907 DOI: 10.1080/14992027.2021.1969455
    OBJECTIVE: To undertake calibration and preliminary validation of a custom-designed computer-based screening audiometer connected to consumer insert phone-earmuff combination for adult pure tone audiometry.

    DESIGN: Part 1 involved electroacoustic measurement and biological calibration of a laptop-earphone pair used for the computer-based audiometry (CBA). Part 2 compared CBA thresholds obtained without a sound booth with those measured using the gold-standard clinical audiometry.

    STUDY SAMPLE: 17 young normal-hearing volunteers (Part 1) and 43 normal and hearing loss subjects (Part 2) recruited from an audiology clinic via convenience sampling.

    RESULTS: The transducer-device combination produced outputs suitable for measuring thresholds down to 0 dB HL. Threshold pairs obtained from the CBA and clinical audiometry were highly correlated (Spearman's correlation coefficient, ρ = 0.92, p pure tone averages of >25 dB HL.

    CONCLUSIONS: The use of a computer-based audiometer application with consumer insert phone-earmuff combination can offer a cost-effective solution for boothless screening audiometry.

    Matched MeSH terms: Audiometry, Pure-Tone
  12. Tang IP, Prepageran N, Ong CA, Puraviappan P
    J Laryngol Otol, 2010 Aug;124(8):913-5.
    PMID: 20426886 DOI: 10.1017/S0022215110000265
    To demonstrate the different clinical presentations of tuberculous otitis media and the management of selected cases.
    Matched MeSH terms: Audiometry, Pure-Tone
  13. Aziz A, Md Daud MK, Nik Othman NA, Abd Rahman N
    Otol Neurotol, 2020 09;41(8):e989-e992.
    PMID: 32472918 DOI: 10.1097/MAO.0000000000002725
    BACKGROUND: Presbycusis is an age-related sensorineural hearing loss and it may reduce quality of life. We conducted a study to establish the prevalence of high-frequency presbycusis in normal hearing individuals and to validate the role of extended high-frequency distortion product otoacoustic emission (DPOAE) in the screening.

    METHOD: A cross-sectional study was conducted among 205 normal hearing adult participants with an age range between 25 and 54 years old. Hearing analysis with extended high-frequency pure-tone audiometry (PTA) and high-frequency DPOAE was carried out for all eligible participants. High-frequency presbycusis was considered to be present when the impairment of more than 25 dB occurs at higher than 8 kHz frequencies on both ears.

    RESULTS: Prevalence of high-frequency presbycusis using extended PTA was 31.7 (95% CI: 25.3, 38.1) and using high-frequency DPOAE was 57.4 (95% CI: 50.7, 64.4). The sensitivity and specificity of high-frequency DPOAE in detecting high-frequency presbycusis were 72.3 and 49.3% respectively with positive predictive value of 39.8% and negative predictive value of 79.3%. The association between age and high-frequency presbycusis was significant based on high-frequency DPOAE (p = 0.029).

    CONCLUSIONS: The prevalence of high-frequency hearing loss is higher with increasing in age. High-frequency DPOAE may be used as a screening tool followed by confirmation using extended PTA. The early detection of presbycusis is important so that measures can be taken to prevent more severe problems developing.

    Matched MeSH terms: Audiometry, Pure-Tone
  14. Balachandran R, Prepageran N, Prepagaran N, Rahmat O, Zulkiflee AB, Hufaida KS
    J Laryngol Otol, 2012 Apr;126(4):345-8.
    PMID: 22310164 DOI: 10.1017/S0022215112000047
    The Bluetooth wireless headset has been promoted as a 'hands-free' device with a low emission of electromagnetic radiation.
    Matched MeSH terms: Audiometry, Pure-Tone
  15. Sulaiman AH, Husain R, Seluakumaran K
    Eur Arch Otorhinolaryngol, 2014 Jun;271(6):1463-70.
    PMID: 23812554 DOI: 10.1007/s00405-013-2612-z
    Although sound exposure from personal listening devices (PLDs) could potentially lead to noise-induced hearing loss (NIHL), the actual hearing risk associated with the use of these devices is still unclear. In this study, early hearing effects related to PLD usage were evaluated in 35 young adult PLD users (listening for >1 h/day, at >50% of the maximum volume setting of their devices) and their age- and sex-matched controls using a combination of conventional and extended high-frequency audiometry as well as transient-evoked otoacoustic emission (TEOAE) and distortion product of otoacoustic emission (DPOAE) measurements. The mean listening duration of the PLD users was 2.7 ± 1.0 h/day while their estimated average listening volume was 81.3 ± 9.0 dBA (free-field corrected). Typical signs of NIHL were not detected in the audiogram of PLD users and their audiometric thresholds at most of the conventional test frequencies (0.25-8 kHz) were comparable with those obtained from controls. However, compared with the controls, mean hearing thresholds of PLD users at many of the extended high-frequencies (9-16 kHz) were significantly higher. In addition, TEOAE and DPOAE amplitudes in users were reduced compared with controls. The deterioration of extended high-frequency thresholds and the decrease in DPOAE amplitudes were more evident in the users' right ears. These results indicate the presence of an early stage of hearing damage in the PLD user group. Preventive steps should be taken as the initial hearing damage in these users could eventually progress into permanent NIHL after many years of PLD use.
    Matched MeSH terms: Audiometry, Pure-Tone
  16. Cheong JP, Soo SS, Manuel AM
    PMID: 27497393 DOI: 10.1016/j.ijporl.2016.06.045
    OBJECTIVE: To determine the factors contributing towards hearing impairment in patients with cleft lip/palate.

    METHOD: A prospective analysis was conducted on 173 patients (346 ears) with cleft lip and palate (CL/P) who presented to the combined cleft clinic at University Malaya Medical Centre (UMMC) over 12 months. The patients' hearing status was determined using otoacoustic emission (OAE), pure tone audiometry (PTA) and auditory brainstem response (ABR). These results were analysed against several parameters, which included age, gender, race, types of cleft pathology, impact and timing of repair surgery.

    RESULTS: The patients' age ranged from 1-26 years old. They comprised 30% with unilateral cleft lip and palate (UCLP), 28% with bilateral cleft lip and palate (BCLP), 28% with isolated cleft palate (ICP) and 14% with isolated cleft lip (ICL). Majority of the patients (68.2%) had normal otoscopic findings. Out of the 346 ears, 241 ears (70%) ears had passed the hearing tests. There was no significant relationship between patients' gender and ethnicity with their hearing status. The types of cleft pathology significantly influenced the outcome of PTA and ABR screening results (p 

    Matched MeSH terms: Audiometry, Pure-Tone
  17. Ho EC, Ong WMW, Li K, Zhang H, Bei YTE, Medapati SVR, et al.
    Int J Audiol, 2018 10;57(10):776-783.
    PMID: 29957077 DOI: 10.1080/14992027.2018.1476781
    OBJECTIVE: To examine the factors associated with late presentation at first hearing aid (HA) fitting, HA choice and usage among users in Singapore.

    DESIGN: Retrospective cross-sectional study.

    STUDY SAMPLE: 1068 subjects issued with HAs at a tertiary hospital from 2001 to 2013.

    RESULTS: Half of the subjects presented with more severe (>55 dB) hearing loss (HL) in their better ear. In multivariable analysis, older age, Malay ethnicity, conductive and mixed HL, and combination type of HL were associated with more severe HL at first presentation. Over 70% of subjects were older than 65 years. Worse pure tone audiometry (PTA) thresholds of the better ear, gradual onset and sensorineural HL were associated with older age presentation. For unilaterally fitted subjects, PTA thresholds were the only determinant of having the better ear aided. Better PTA thresholds, younger age and sensorineural HL were associated with choosing in ear compared to behind the ear HAs. Younger age and worse PTA of the better ear were associated with ≥4 h of daily HA usage.

    CONCLUSIONS: Age, ethnicity and type of HL were important determinants for more severe HL at first HA fitting. Older patients and those with better hearing were less likely to use their HAs regularly.

    Matched MeSH terms: Audiometry, Pure-Tone
  18. Gendeh BS, Said H, Gibb AG, Aziz NS, Zahir ZM
    J Laryngol Otol, 1991 Dec;105(12):999-1001.
    PMID: 1787382
    In a prospective study on 47 patients, 16 mg of gentamicin per two litres dialysate was administered intraperitoneally at every cycle of intermittent peritoneal dialysis, carried out over the course of several days. Serum gentamicin sampling, pure tone audiometry and caloric tests were performed before and during the treatment. The gentamicin levels reached at the end of the thirtieth cycle were observed to be low. In view of this, the risk of acute ototoxicity was considered to be minimal. This was confirmed by the absence of clinical audiometric or vestibulometric evidence of toxicity.
    Matched MeSH terms: Audiometry, Pure-Tone
  19. Gendeh BS, Said H, Gibb AG, Aziz NS, Kong N, Zahir ZM
    J Laryngol Otol, 1993 Aug;107(8):681-5.
    PMID: 8409715 DOI: 10.1017/s0022215100124132
    A prospective study was undertaken of 10 chronic renal failure patients on Continuous Ambulatory Peritoneal Dialysis (CAPD) complicated by repeated bouts of peritonitis treated with gentamicin. Each 10-day treatment course consisted of a 120 mg loading dose, followed by 16 mg in 21 of peritoneal dialysate, given four times a day. Serum gentamicin analysed by enzyme immunoassay showed a mean level of 5.2 micrograms/ml, (range 3.7 to 6.6 mg/ml) four hours after the loading dose. Similar levels, well within the therapeutic range, were maintained on the 3rd, 5th, 7th and 9th days of intraperitoneal gentamicin therapy, suggesting no accumulation of gentamicin in the serum. Pure tone audiometry, electronystagmography and clinical assessment were performed during each course of treatment. Although no evidence of ototoxicity was found during the first two courses of gentamicin, but disequilibrium and bobbing oscillopsia were present during the third and fourth courses of gentamicin. These findings could be explained by cumulative injury to the vestibular apparatus caused by repeated therapeutic insults.
    Matched MeSH terms: Audiometry, Pure-Tone
  20. Saniasiaya J
    Ear Nose Throat J, 2021 Apr;100(2_suppl):152S-154S.
    PMID: 32755405 DOI: 10.1177/0145561320946902
    Matched MeSH terms: Audiometry, Pure-Tone