MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.
RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.
CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.
METHODS: This study involved 307 adults aged 60 years and older. Participants had their hearing and cognition measured using pure tone audiometry and Mini Mental State Examination (MMSE), respectively.
RESULTS: Pure tone average (low) accounted for significant but minimal amount of variance in measure of MMSE. Multiple regression analyses were also performed on normal and impaired hearing cohorts and cohorts with younger (60-69 years) and older (≥70 years) groups. The results revealed a significant relationship between PTA (low) and MMSE only in the younger age group. In contrast, no significant relationship was found between PTA (high) and cognition in any of the cohorts.
CONCLUSION: Pure tone average (low) is significantly but minimally related to measure of general cognitive status. Similar relationship is not observed between high-frequency hearing and cognition. Further research using a more comprehensive cognitive test battery is needed to confirm the lack of association between high-frequency hearing and cognition.
METHODS: A retrospective descriptive cohort study on the audiological findings detected during the first hearing assessment done on a child with craniosynostosis using otoacoustic emissions, pure tone audiometry or auditory brainstem response examination. The main aim of this study was to evaluate the type and severity of hearing loss when compared between syndromic and non-sydromic craniosynostosis, and other associated contributory factors.
RESULTS: A total of 31 patients with 62 ears consisting of 14 male patients and 17 female patients were evaluated. Twenty two patients (71%) were syndromic and 9 (29%) were non-syndromic craniosynostosis. Amongst the syndromic craniosynostosis, 9 (41%) had Apert syndrome, 7 (32%) had Crouzon syndrome, 5 (23%) had Pfieffer syndrome and 1 (4%) had Shaethre Chotzen syndrome. Patients with syndromic craniosynostosis were more likely to present with all types and severity of hearing loss, including severe to profound sensorineural hearing loss while children with non-syndromic craniosynostosis were likely to present with normal hearing (p
OBJECTIVE: This study aims to investigate the feasibility of EEG measurements as an objective indicator for the identification of tinnitus-associated neural activities.
METHODS: To reduce heterogeneity, participants served as their own control using residual inhibition (RI) to modulate the tinnitus perception in a within-subject EEG study design with a tinnitus group. In addition, comparison with a nontinnitus control group allowed for a between-subjects comparison. We will apply RI stimulation to generate tinnitus and nontinnitus conditions in the same subject. Furthermore, high-frequency audiometry (up to 13 kHz) and tinnitometry will be performed.
RESULTS: This work was funded by the Infrastructure Grant of the University of Bern, Bern, Switzerland and Bernafon AG, Bern, Switzerland. Enrollment for the study described in this protocol commenced in February 2018. Data analysis is currently under way and the first results are expected to be submitted for publication in 2019.
CONCLUSIONS: This study design helps in comparing the neural activity between conditions in the same individual, thereby addressing a notable limitation of previous EEG tinnitus studies. In addition, the high-frequency assessment will help to analyze and classify tinnitus symptoms beyond the conventional clinical standard.
INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/12270.
DESIGN: Part 1 involved electroacoustic measurement and biological calibration of a laptop-earphone pair used for the computer-based audiometry (CBA). Part 2 compared CBA thresholds obtained without a sound booth with those measured using the gold-standard clinical audiometry.
STUDY SAMPLE: 17 young normal-hearing volunteers (Part 1) and 43 normal and hearing loss subjects (Part 2) recruited from an audiology clinic via convenience sampling.
RESULTS: The transducer-device combination produced outputs suitable for measuring thresholds down to 0 dB HL. Threshold pairs obtained from the CBA and clinical audiometry were highly correlated (Spearman's correlation coefficient, ρ = 0.92, p pure tone averages of >25 dB HL.
CONCLUSIONS: The use of a computer-based audiometer application with consumer insert phone-earmuff combination can offer a cost-effective solution for boothless screening audiometry.
METHOD: A cross-sectional study was conducted among 205 normal hearing adult participants with an age range between 25 and 54 years old. Hearing analysis with extended high-frequency pure-tone audiometry (PTA) and high-frequency DPOAE was carried out for all eligible participants. High-frequency presbycusis was considered to be present when the impairment of more than 25 dB occurs at higher than 8 kHz frequencies on both ears.
RESULTS: Prevalence of high-frequency presbycusis using extended PTA was 31.7 (95% CI: 25.3, 38.1) and using high-frequency DPOAE was 57.4 (95% CI: 50.7, 64.4). The sensitivity and specificity of high-frequency DPOAE in detecting high-frequency presbycusis were 72.3 and 49.3% respectively with positive predictive value of 39.8% and negative predictive value of 79.3%. The association between age and high-frequency presbycusis was significant based on high-frequency DPOAE (p = 0.029).
CONCLUSIONS: The prevalence of high-frequency hearing loss is higher with increasing in age. High-frequency DPOAE may be used as a screening tool followed by confirmation using extended PTA. The early detection of presbycusis is important so that measures can be taken to prevent more severe problems developing.
METHOD: A prospective analysis was conducted on 173 patients (346 ears) with cleft lip and palate (CL/P) who presented to the combined cleft clinic at University Malaya Medical Centre (UMMC) over 12 months. The patients' hearing status was determined using otoacoustic emission (OAE), pure tone audiometry (PTA) and auditory brainstem response (ABR). These results were analysed against several parameters, which included age, gender, race, types of cleft pathology, impact and timing of repair surgery.
RESULTS: The patients' age ranged from 1-26 years old. They comprised 30% with unilateral cleft lip and palate (UCLP), 28% with bilateral cleft lip and palate (BCLP), 28% with isolated cleft palate (ICP) and 14% with isolated cleft lip (ICL). Majority of the patients (68.2%) had normal otoscopic findings. Out of the 346 ears, 241 ears (70%) ears had passed the hearing tests. There was no significant relationship between patients' gender and ethnicity with their hearing status. The types of cleft pathology significantly influenced the outcome of PTA and ABR screening results (p
DESIGN: Retrospective cross-sectional study.
STUDY SAMPLE: 1068 subjects issued with HAs at a tertiary hospital from 2001 to 2013.
RESULTS: Half of the subjects presented with more severe (>55 dB) hearing loss (HL) in their better ear. In multivariable analysis, older age, Malay ethnicity, conductive and mixed HL, and combination type of HL were associated with more severe HL at first presentation. Over 70% of subjects were older than 65 years. Worse pure tone audiometry (PTA) thresholds of the better ear, gradual onset and sensorineural HL were associated with older age presentation. For unilaterally fitted subjects, PTA thresholds were the only determinant of having the better ear aided. Better PTA thresholds, younger age and sensorineural HL were associated with choosing in ear compared to behind the ear HAs. Younger age and worse PTA of the better ear were associated with ≥4 h of daily HA usage.
CONCLUSIONS: Age, ethnicity and type of HL were important determinants for more severe HL at first HA fitting. Older patients and those with better hearing were less likely to use their HAs regularly.