Displaying publications 1 - 20 of 64 in total

Abstract:
Sort:
  1. Daood U, Yiu CKY
    Dent Mater, 2019 02;35(2):206-216.
    PMID: 30509480 DOI: 10.1016/j.dental.2018.11.018
    OBJECTIVE: To evaluate the transdentinal cytotoxicity and macrophage phenotype response to a novel quaternary ammonium silane (QAS) cavity disinfectant.

    METHODS: NIH 3T3 mouse fibroblasts were cultured in Dulbecco's Modified Eagle's Medium and incubated for 3 days. The cells (3×104) were seeded on the pulpal side of dentine discs and the occlusal side of the discs were treated with different cavity disinfectants: Group 1: de-ionized water (control); Group 2: 2% chlorhexidine (CHX); Group 3: 2% QAS; Group 4: 5% QAS, and Group 5: 10% QAS. Cell morphology of NIH 3T3 cells was examined using scanning electron microscopy (SEM) and cell viability was assessed using Trypan blue assay. The eluates were collected and applied on cells seeded in 24-well plates. The total protein production, alkaline phosphatase activity and deposition of mineralized nodules were evaluated after 7 and 14 days. Immunofluorescence staining was performed on the samples with primary antibodies of CD68+, CD80+, and CD163+ assessing the macrophage M1/M2 phenotypes. The macrophages were imaged using a confocal scanning light microscope with an excitation wavelength of 488nm.

    RESULTS: No significant difference in cell viability (p<0.0001), total protein production (p<0.01) and mineralized nodule production (p<0.05) was found between 2% QAS and the control, which was significantly higher than 2% CHX, 5% and 10% QAS after 14 days. Alkaline phosphatase production of 2% QAS was significantly lower than the control (p<0.001), but higher than 2% CHX at 14 days. The M1/M2 macrophage ratio was also significantly lower in the 2% and 10% QAS groups (p<0.05) compared to the control and 2% CHX groups.

    SIGNIFICANCE: The 2% QAS cavity disinfectant does not have cytotoxic effects on 3T3 NIH mouse fibroblast cells and the predominance of the anti-inflammatory phenotype after its application may stimulate healing and tissue repair.

    Matched MeSH terms: Disinfectants*
  2. Daood U, Burrow MF, Yiu CKY
    Clin Oral Investig, 2020 Feb;24(2):649-661.
    PMID: 31115692 DOI: 10.1007/s00784-019-02928-7
    OBJECTIVE: Evaluate effect of quaternary ammonium silane (QAS) cavity disinfectant on cariogenic biofilm.

    MATERIALS AND METHODS: Single- (Streptococcus mutans or Lactobacillus acidophilus), dual- (Streptococcus mutans/Lactobacillus Acidophilus), and multi-species (Streptococcus mutans, Actinomyces naeslundii, and Streptococcus sanguis) biofilms were grown on acid-etched dentine discs. Biofilms were incubated (120 min/37 °C) and allowed to grow for 3 days anaerobically. Discs (no treatment) served as control (group 1). Groups II, III, IV, and V were then treated with 2% chlorhexidine, and 2%, 5%, and 10% QAS (20 s). Discs were returned to well plates with 300 μL of bacterial suspension and placed in anaerobic incubator at 37 °C and biofilms redeveloped for 4 days. Confocal microscopy, Raman, CFU, and MTT assay were performed.

    RESULTS: Raman peaks show shifts at 1450 cm-1, 1453 cm-1, 1457 cm-1, 1460 cm-1, and 1462 cm-1 for control, 2% CHX, 2%, 5%, and 10% QAS groups in multi-species biofilms. There was reduction of 484 cm-1 band in 10% QAS group. CLSM revealed densely clustered green colonies in control group and red confluent QAS-treated biofilms with significantly lower log CFU for single/dual species. Metabolic activities of Streptococcus mutans and Lactobacillus acidophilus decreased with increasing QAS exposure time.

    CONCLUSION: Quaternary ammonium silanes possess antimicrobial activities and inhibit growth of cariogenic biofilms.

    CLINICAL SIGNIFICANCE: Available data demonstrated use of QAS as potential antibacterial cavity disinfectant in adhesive dentistry. Experimental QAS can effectively eliminate caries-forming bacteria, when used inside a prepared cavity, and can definitely overcome problems associated with present available cavity disinfectants.

    Matched MeSH terms: Disinfectants*
  3. Ismail Hossain M, El-Harbawi M, Noaman YA, Bustam MA, Alitheen NB, Affandi NA, et al.
    Chemosphere, 2011 Jun;84(1):101-4.
    PMID: 21421256 DOI: 10.1016/j.chemosphere.2011.02.048
    Eight hydroxylammonium-based room temperature ionic liquids (ILs) have been synthesized by acid-base neutralization of ethanolamines with organic acids. The ILs were characterized by infrared and nuclear magnetic resonance spectroscopies and elemental analysis. Their anti-microbial activities were determined using the well-diffusion method. All eight ILs were toxic to Staphylococcus aureus, while 2-hydroxyethylammonium lactate and 2-hydroxy-N-(2-hydroxyethyl)-N-methylethanaminium acetate showed high anti-microbial activity against a wide range of human pathogens.
    Matched MeSH terms: Disinfectants/chemical synthesis; Disinfectants/toxicity
  4. Nor A'shimi MH, Alattraqchi AG, Mohd Rani F, A Rahman NI, Ismail S, Abdullah FH, et al.
    J Infect Dev Ctries, 2019 07 31;13(7):626-633.
    PMID: 32065820 DOI: 10.3855/jidc.11455
    INTRODUCTION: Acinetobacter baumannii is a Gram-negative nosocomial pathogen that has the capacity to develop resistance to all classes of antimicrobial compounds. However, very little is known regarding its susceptibility to biocides (antiseptics and disinfectants) and capacity to form biofilms, particularly for Malaysian isolates.

    AIM: To determine the susceptibility of A. baumannii isolates to commonly-used biocides, investigate their biofilm-forming capacities and the prevalence of biocide resistance and biofilm-associated genes.

    METHODOLOGY: . The minimum inhibitory concentration (MIC) values of 100 A. baumannii hospital isolates from Terengganu, Malaysia, towards the biocides benzalkonium chloride (BZK), benzethonium chloride (BZT) and chlorhexidine digluconate (CLX), were determined by broth microdilution. The isolates were also examined for their ability to form biofilms in 96-well microplates. The prevalence of biocide resistance genes qacA, qacE and qacDE1 and the biofilm-associated genes bap and abaI were determined by polymerase chain reaction (PCR).

    RESULTS: Majority of the A. baumannii isolates (43%) showed higher MIC values (> 50 µg/mL) for CLX than for BZK (5% for MIC > 50 µg/mL) and BZT (9% for MIC > 50 µg/mL). The qacDE1 gene was predominant (63%) followed by qacE (28%) whereas no isolate was found harbouring qacA. All isolates were positive for the bap and abaI genes although the biofilm-forming capacity varied among the isolates.

    CONCLUSION: The Terengganu A. baumannii isolates showed higher prevalence of qacDE1 compared to qacE although no correlation was found with the biocides' MIC values. No correlation was also observed between the isolates' biofilm-forming capacity and the MIC values for the biocides.

    Matched MeSH terms: Disinfectants/pharmacology*
  5. Tata MD, Kwan KC, Abdul-Razak MR, Paramalingam S, Yeen WC
    Ann Thorac Surg, 2009 May;87(5):1613-4.
    PMID: 19379926 DOI: 10.1016/j.athoracsur.2008.10.019
    A 39-year-old Indian man presented with necrotizing soft tissue infection of his right forearm and previously undiagnosed diabetes mellitus. The infection progressively worsened to involve his right lateral chest wall despite multiple debridements and systemic antibiotics. His right arm was eventually disarticulated along with wide debridement of the surrounding tissue. Aggressive wound debridement, mechanical scrubbing, and irrigation were then initiated every 8 hours. A superoxidized solution was later introduced as a wound irrigant and dressing agent. The large defect was suitable for split-thickness skin grafting after 16 days of a strict wound management routine with the superoxidized solution.
    Matched MeSH terms: Disinfectants/therapeutic use
  6. Goh CF, Ming LC, Wong LC
    Clin Dermatol, 2020 10 02;39(2):314-322.
    PMID: 34272029 DOI: 10.1016/j.clindermatol.2020.09.005
    Infection preventive practice of using disinfectants against SARS-CoV-2 has become the new normal due to the COVID-19 pandemic. Although disinfectants may not be applied directly to the human body, it remains at high risk of exposure including close skin contact on disinfected surfaces or during handling. This dermal contact, on a regular basis, can induce hazardous skin reactions like irritation, inflammation, and burning in severe conditions. Disinfectants are germicide chemicals that can penetrate the skin and create skin reactions that are usually regarded as irritant and allergic contact dermatitis. More importantly, disinfectants can react with skin components (proteins and lipids) to facilitate their skin penetration and disrupt the skin barrier function. Whereas the antimicrobial actions of disinfectants are well understood, much less is known regarding their dermatologic reactions, including but not limited to irritation and hypersensitivity. We reviewed the skin reactions created by those disinfectants against SARS-CoV-2 approved by the European Chemical Agency and the US Environmental Protection Agency.
    Matched MeSH terms: Disinfectants/adverse effects*
  7. Harbarth S, Tuan Soh S, Horner C, Wilcox MH
    J Hosp Infect, 2014 Aug;87(4):194-202.
    PMID: 24996517 DOI: 10.1016/j.jhin.2014.04.012
    Given the breadth and depth of antiseptic use, it is surprising how few large-scale studies have been undertaken into the consequences of their use, particularly in clinical practice. Depending on your point of view, this may either reflect an assurance that reduced susceptibility to antiseptics, and notably whether this confers cross-resistance to systemically administered antimicrobial agents, is not an issue of concern, or relative ignorance about the potential threat.
    Matched MeSH terms: Disinfectants/pharmacology*
  8. Kumbargere Nagraj S, Eachempati P, Paisi M, Nasser M, Sivaramakrishnan G, Verbeek JH
    Cochrane Database Syst Rev, 2020 Oct 12;10(10):CD013686.
    PMID: 33047816 DOI: 10.1002/14651858.CD013686.pub2
    BACKGROUND: Many dental procedures produce aerosols (droplets, droplet nuclei and splatter) that harbour various pathogenic micro-organisms and may pose a risk for the spread of infections between dentist and patient. The COVID-19 pandemic has led to greater concern about this risk.

    OBJECTIVES: To assess the effectiveness of methods used during dental treatment procedures to minimize aerosol production and reduce or neutralize contamination in aerosols.

    SEARCH METHODS: Cochrane Oral Health's Information Specialist searched the following databases on 17 September 2020: Cochrane Oral Health's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (in the Cochrane Library, 2020, Issue 8), MEDLINE Ovid (from 1946); Embase Ovid (from 1980); the WHO COVID-19 Global literature on coronavirus disease; the US National Institutes of Health Trials Registry (ClinicalTrials.gov); and the Cochrane COVID-19 Study Register. We placed no restrictions on the language or date of publication.

    SELECTION CRITERIA: We included randomized controlled trials (RCTs) and controlled clinical trials (CCTs) on aerosol-generating procedures (AGPs) performed by dental healthcare providers that evaluated methods to reduce contaminated aerosols in dental clinics (excluding preprocedural mouthrinses). The primary outcomes were incidence of infection in dental staff or patients, and reduction in volume and level of contaminated aerosols in the operative environment. The secondary outcomes were cost, accessibility and feasibility.

    DATA COLLECTION AND ANALYSIS: Two review authors screened search results, extracted data from the included studies, assessed the risk of bias in the studies, and judged the certainty of the available evidence. We used mean differences (MDs) and 95% confidence intervals (CIs) as the effect estimate for continuous outcomes, and random-effects meta-analysis to combine data. We assessed heterogeneity.

    MAIN RESULTS: We included 16 studies with 425 participants aged 5 to 69 years. Eight studies had high risk of bias; eight had unclear risk of bias. No studies measured infection. All studies measured bacterial contamination using the surrogate outcome of colony-forming units (CFU). Two studies measured contamination per volume of air sampled at different distances from the patient's mouth, and 14 studies sampled particles on agar plates at specific distances from the patient's mouth. The results presented below should be interpreted with caution as the evidence is very low certainty due to heterogeneity, risk of bias, small sample sizes and wide confidence intervals. Moreover, we do not know the 'minimal clinically important difference' in CFU. High-volume evacuator Use of a high-volume evacuator (HVE) may reduce bacterial contamination in aerosols less than one foot (~ 30 cm) from a patient's mouth (MD -47.41, 95% CI -92.76 to -2.06; 3 RCTs, 122 participants (two studies had split-mouth design); very high heterogeneity I² = 95%), but not at longer distances (MD -1.00, -2.56 to 0.56; 1 RCT, 80 participants). One split-mouth RCT (six participants) found that HVE may not be more effective than conventional dental suction (saliva ejector or low-volume evacuator) at 40 cm (MD CFU -2.30, 95% CI -5.32 to 0.72) or 150 cm (MD -2.20, 95% CI -14.01 to 9.61). Dental isolation combination system One RCT (50 participants) found that there may be no difference in CFU between a combination system (Isolite) and a saliva ejector (low-volume evacuator) during AGPs (MD -0.31, 95% CI -0.82 to 0.20) or after AGPs (MD -0.35, -0.99 to 0.29). However, an 'n of 1' design study showed that the combination system may reduce CFU compared with rubber dam plus HVE (MD -125.20, 95% CI -174.02 to -76.38) or HVE (MD -109.30, 95% CI -153.01 to -65.59). Rubber dam One split-mouth RCT (10 participants) receiving dental treatment, found that there may be a reduction in CFU with rubber dam at one-metre (MD -16.20, 95% CI -19.36 to -13.04) and two-metre distance (MD -11.70, 95% CI -15.82 to -7.58). One RCT of 47 dental students found use of rubber dam may make no difference in CFU at the forehead (MD 0.98, 95% CI -0.73 to 2.70) and occipital region of the operator (MD 0.77, 95% CI -0.46 to 2.00). One split-mouth RCT (21 participants) found that rubber dam plus HVE may reduce CFU more than cotton roll plus HVE on the patient's chest (MD -251.00, 95% CI -267.95 to -234.05) and dental unit light (MD -12.70, 95% CI -12.85 to -12.55). Air cleaning systems One split-mouth CCT (two participants) used a local stand-alone air cleaning system (ACS), which may reduce aerosol contamination during cavity preparation (MD -66.70 CFU, 95% CI -120.15 to -13.25 per cubic metre) or ultrasonic scaling (MD -32.40, 95% CI - 51.55 to -13.25). Another CCT (50 participants) found that laminar flow in the dental clinic combined with a HEPA filter may reduce contamination approximately 76 cm from the floor (MD -483.56 CFU, 95% CI -550.02 to -417.10 per cubic feet per minute per patient) and 20 cm to 30 cm from the patient's mouth (MD -319.14 CFU, 95% CI - 385.60 to -252.68). Disinfectants ‒ antimicrobial coolants Two RCTs evaluated use of antimicrobial coolants during ultrasonic scaling. Compared with distilled water, coolant containing chlorhexidine (CHX), cinnamon extract coolant or povidone iodine may reduce CFU: CHX (MD -124.00, 95% CI -135.78 to -112.22; 20 participants), povidone iodine (MD -656.45, 95% CI -672.74 to -640.16; 40 participants), cinnamon (MD -644.55, 95% CI -668.70 to -620.40; 40 participants). CHX coolant may reduce CFU more than povidone iodine (MD -59.30, 95% CI -64.16 to -54.44; 20 participants), but not more than cinnamon extract (MD -11.90, 95% CI -35.88 to 12.08; 40 participants).

    AUTHORS' CONCLUSIONS: We found no studies that evaluated disease transmission via aerosols in a dental setting; and no evidence about viral contamination in aerosols. All of the included studies measured bacterial contamination using colony-forming units. There appeared to be some benefit from the interventions evaluated but the available evidence is very low certainty so we are unable to draw reliable conclusions. We did not find any studies on methods such as ventilation, ionization, ozonisation, UV light and fogging. Studies are needed that measure contamination in aerosols, size distribution of aerosols and infection transmission risk for respiratory diseases such as COVID-19 in dental patients and staff.

    Matched MeSH terms: Disinfectants
  9. Kannaiyan K, Rakshit P, Bhat MPS, Sadasiva SKK, Babu SC, Ummer H
    J Contemp Dent Pract, 2023 Nov 01;24(11):891-894.
    PMID: 38238278 DOI: 10.5005/jp-journals-10024-3563
    AIM: The current study aimed to determine the impact of three different disinfectants on the surface roughness and color stability of heat-cure acrylic denture material.

    MATERIALS AND METHODS: Using a stainless-steel mold, disc-shaped wax patterns with dimensions of 10 mm in diameter and 2 mm thick (in accordance with ADA Specification No. 12) were created and prepared for a total of 75 acrylic samples. Dimensions of all 75 acrylic samples were checked with a digital Vernier caliper. About 25 samples of denture base material were immersed in three different chemical disinfectants: Group I: immersed in chlorhexidine gluconate solution, group II: immersed in sodium hypochlorite solution, and group III: immersed in glutaraldehyde solution. All samples were scrubbed daily for 1 minute with the appropriate disinfectant and submerged for 10 minutes in the same disinfectant. Between disinfection cycles, samples were kept in distilled water at 37°C. Color stability was measured using a reflection spectrophotometer. Surface roughness values were measured by a profilometer at baseline following 15 days and 30 days.

    RESULTS: After 15 days, the color stability was better in chlorhexidine gluconate solution group (4.88 ± 0.24) than sodium hypochlorite solution (4.74 ± 0.18) and glutaraldehyde solution group (4.46 ± 0.16). The mean surface roughness was less in glutaraldehyde solution group (2.10 ± 0.19), followed by chlorhexidine gluconate solution group (2.48 ± 0.09) and sodium hypochlorite solution group (2.64 ± 0.03). After 30 days, the color stability was significantly better in chlorhexidine gluconate solution group (4.40 ± 0.02), followed by sodium hypochlorite solution (4.06 ± 0.16) and glutaraldehyde solution group (3.87 ± 0.17). The mean surface roughness was significantly lesser in glutaraldehyde solution group (2.41 ± 0.14), followed by chlorhexidine gluconate solution group (2.94 ± 0.08) and sodium hypochlorite solution group (3.02 ± 0.13).

    CONCLUSION: In conclusion, the color stability was significantly better in chlorhexidine gluconate solution group than sodium hypochlorite solution and glutaraldehyde solution group. But the surface roughness was significantly lesser in the glutaraldehyde solution group, followed by the chlorhexidine gluconate and sodium hypochlorite solution group.

    CLINICAL SIGNIFICANCE: The maintenance of the prosthesis requires the use of a denture disinfectant; therefore, it is crucial to select one that is effective but would not have a negative impact on the denture base resin's inherent characteristics over time. How to cite this article: Kannaiyan K, Rakshit P, Bhat MPS, et al. Effect of Different Disinfecting Agents on Surface Roughness and Color Stability of Heat-cure Acrylic Denture Material: An In Vitro Study. J Contemp Dent Pract 2023;24(11):891-894.

    Matched MeSH terms: Disinfectants*
  10. Norhani Mohidin, Tee, Lee Fung
    MyJurnal
    This survey represents an initial examination of contact lens practice in Malaysia. It is based on a questionnaire that was sent to selected members of the Association of the Malaysian Optometrists to survey the prescribing habits of g contact lenses and care products. Questions included types of lenses prescribed, care systems frequently recommended and types of complications seen. Optometrists in Malaysia prescribed an average of 90 new pairs of contact lenses per year. Soft lenses made up 84% of the prescription followed by 14% of rigid gas permeable lenses and 1.5% of polymethymethacrylate lenses. Disposable/frequent replacement lenses accounted for 60% of the soft lenses prescribed. The most commonly prescribed disinfecting system was chemical disinfection. The most common complication seen during aftercare consultation was dry eye-related problems.
    Matched MeSH terms: Disinfectants
  11. Khalit WNAW, Tay KS
    Ecotoxicol Environ Saf, 2017 Nov;145:214-220.
    PMID: 28738204 DOI: 10.1016/j.ecoenv.2017.07.020
    Unmetabolized pharmaceuticals often enter the water treatment plants and exposed to various treatment processes. Among these water treatment processes, disinfection is a process which involves the application of chemical oxidation to remove pathogen. Untreated pharmaceuticals from primary and secondary treatment have the potential to be exposed to the chemical oxidation process during disinfection. This study investigated the kinetics and mechanism of the degradation of sotalol during chlorination process. Chlorination with hypochlorous acid (HOCl) as main reactive oxidant has been known as one of the most commonly used disinfection methods. The second order rate constant for the reaction between sotalol and free available chlorine (FAC) was found to decrease from 60.1 to 39.1M-1min-1 when the pH was increased from 6 to 8. This result was mainly attributed by the decreased of HOCl concentration with increasing pH. In the real water samples, the presence of the higher amount of organic content was found to reduce the efficiency of chlorination in the removal of sotalol. This result showed that sotalol competes with natural organic matter to react with HOCl during chlorination. After 24h of FAC exposure, sotalol was found to produce three stable transformation by-products. These by-products are mainly chlorinated compounds. According to the acute and chronic toxicity calculated using ECOSAR computer program, the transformation by-products are more harmful than sotalol.
    Matched MeSH terms: Disinfectants/chemistry*
  12. Xuan L, Hui D, Cheng W, Wong AHH, Han G, Tan WK, et al.
    Materials (Basel), 2017 Jul 12;10(7).
    PMID: 28773150 DOI: 10.3390/ma10070789
    The effects of alkaline copper quaternary (ACQ) and zinc borate (ZB) on the resistance of corn stalk fiber (CSF)-reinforced high-density polyethylene (HDPE) composites to biodegradation were examined. Both biocides could inhibit termites, mold fungi, and wood-decay fungi, even at high CSF formulations (i.e., 60%). Additionally, ACQ enhanced the resistance of the composite materials to certain biotic stresses better than ZB. The CSF/HDPE composites treated with ACQ at the 3.0% level exhibited a superior performance against termites, white rot fungi, and brown rot fungi. ACQ treatment at the 1% level was optimal for inhibiting soft rot fungi. Furthermore, mold growth was not observed on ACQ-treated CSF/HDPE samples. The untreated CSF/HDPE composites were more susceptible to mold infections and decay than the untreated poplar/HDPE composites, likely because of an incomplete removal of the pith. The chemical features of the corn stalk may also have influenced these differences, but this possibility will need to be explored in future investigations. Furthermore, the CSF component of CSF/HDPE composites is highly susceptible to fungal attacks, with the soft rot fungus inducing the largest mass losses, followed by the white rot fungus, and then the brown rot fungus.
    Matched MeSH terms: Disinfectants
  13. How SW, Low DYS, Leo BF, Manickam S, Goh BH, Tang SY
    J Hosp Infect, 2023 Jul;137:24-34.
    PMID: 37044283 DOI: 10.1016/j.jhin.2023.03.022
    Following recent viral outbreaks, there has been a significant increase in global demand for gloves. Biomedical research focuses increasingly on antimicrobial gloves to combat microbial transmission and hospital-acquired infections. Most antimicrobial gloves are manufactured using antimicrobial chemicals such as disinfectants, biocides and sanitizers. The design of antimicrobial gloves incorporates advanced technologies, including colloidal particles and nanomaterials, to enhance antimicrobial effectiveness. A category of antimicrobial gloves also explores and integrates natural antimicrobial benefits from animals, plants and micro-organisms. Many types of antimicrobial agents are available; however, it is crucial that the selected agent exhibits a broad spectrum of activity and is not susceptible to promoting resistance. Additionally, future research should focus on the potential effect of antimicrobial gloves on the skin microbiota and irritation during extended wear. Careful integration of the antimicrobial agent is essential to ensure optimal effectiveness without compromising the mechanical properties of the gloves.
    Matched MeSH terms: Disinfectants*
  14. Jindal HM, Chandramathi S, Sekaran SD, Suresh K
    Trop Biomed, 2020 Sep 01;37(3):626-636.
    PMID: 33612777 DOI: 10.47665/tb.37.3.626
    Hand hygiene is the topmost crucial procedure to prevent hospital-acquired infections. Choosing an effective hand disinfectant is necessary in enforcing good hand hygiene practice especially in hospital settings. The aim of the study was to investigate the efficacy of Aaride AGT-1 as a hand disinfectant for the inhibition of pathogenic microorganisms' transmission among both patients and personnel in the health care system compared to other commercially available disinfectants. In the present study, a new hand disinfectant Aaride AGT-1 was tested against several bacterial and viral pathogens to evaluate its antimicrobial activity profile. The results revealed that Aaride AGT-1 displayed the highest antibacterial activity against five pathogenic bacteria including MRSA when compared to other commercially available hand sanitizers. Aaride AGT-1 showed the lowest percentage needed to inhibit the growth of bacterial pathogens. In addition, results obtained from time killing assay revealed that Aaride AGT-1 demonstrated the best killing kinetics, by eradicating the bacterial cells rapidly within 0.5 min with 6 log reduction (>99.99% killing). Also, Aaride AGT1 was able to reduce 100% plaque formed by three viruses namely HSV-1, HSV-2 and EV-71. In conclusion, Aaride AGT-1 is capable of killing wide-spectrum of pathogens including bacteria and viruses compared to other common disinfectants used in hospital settings. Aaride AGT-1's ability to kill both bacteria and viruses contributes as valuable addition to the hand disinfection portfolio.
    Matched MeSH terms: Disinfectants
  15. Keah KC, Jegathesan M, Tan SC, Chan SH, Chee OM, Cheong YM, et al.
    Med J Malaysia, 1995 Dec;50(4):291-7.
    PMID: 8668045
    A study to determine contamination of diluted disinfectants at different points in preparation and use in 6 Malaysian hospitals was done using the in-use test. A growth of > or = 250 organisms/ml was taken as an indication of contamination. A total of 342 (7.9%) of the 4316 freshly diluted samples collected from disinfectant bottles in the pharmacy were found to be contaminated. The bacterial isolates obtained were Pseudomonas spp. (42.4%), Moraxella spp. (22.0%), Flavobacterium spp. (11.6%) and Enterobacter spp. (4.2%). Three hundred and sixty seven out of 2278 ward stock were contaminated. The isolates were Pseudomonas spp. (48.6%), Moraxella spp. (17.8%), Acinetobacter spp. (8.9%) and Flavobacterium spp. (7.0%). Of the 9265 disinfectants in-use, 1519 (16.4%) were contaminated. Among the organisms isolated were Pseudomonas spp. (44.3%), Bacillus spp. (13.0%), Enterobacter spp. (9.5%) and Acinetobacter spp. (7.3%). The results indicated a high level of contamination of diluted disinfectants prepared in the pharmacy, stored and used in the wards. This gave a high index of suspicion that recommendations for cleaning of disinfectant containers before refilling, handling of diluted stock solutions and using of disinfectants were not closely adhered to. Standard disinfection procedures outlined in the disinfection and sterilization policy by the Ministry of Health should therefore be followed.
    Matched MeSH terms: Disinfectants/standards*
  16. Mohd Masri S, Nazni WA, Lee HL, T Rogayah TA, Subramaniam S
    Trop Biomed, 2005 Dec;22(2):185-9.
    PMID: 16883286 MyJurnal
    Three new techniques of sterilising maggots of Lucilia cuprina for the purpose of debriding intractable wounds were studied. These techniques were utilisation of ultra-violet C (UVC) and maggot sterilisation with disinfectants. The status of sterility was checked on nutrient agar and blood agar and confirmed with staining. The indicators for the effectiveness of the methods were sterility and survival rate of the eggs or larvae. Egg sterilisation with UVC had the lowest hatching rate (16+/-0.00%) while egg sterilisation with disinfectants showed high hatching rate (36.67+/-4.41%) but low maggot survival rate (31.67+/-1.67%). Sterilisation of the maggots was the most suitable, since the survival rate was the highest (88.67+/-0.88%). Complete sterility was achieved in all cases, except that Proteus mirabilis was consistently found. However, the presence of this microorganism was considered beneficial.
    Matched MeSH terms: Disinfectants/pharmacology
  17. Zulkifli I, Fauziah O, Omar AR, Shaipullizan S, Siti Selina AH
    Vet Res Commun, 1999 Mar;23(2):91-9.
    PMID: 10359153
    Two experiments were conducted to evaluate the effect of formaldehyde vaporization of a hatcher on the tracheal epithelium of chick embryos, and on the production performance and behaviour of commercial broiler chicks. In experiment 1, chick embryos were exposed to 23.5 ppm of formaldehyde vapour during the last 3 days of incubation. Tracheal samples were taken at 0, 6, 30 and 54 h after exposure to formaldehyde and examined by scanning electron microscopy for pathological changes. Observable lesions included excessive accumulation of mucus, matted cilia, loss of cilia and sloughing of the epithelium. The lesions were more severe in chicks exposed for 54 h as compared to those exposed for 6 or 30 h. In experiment 2, 60 chicks that had been exposed to formaldehyde vapour as above and 60 control chicks were used to investigate the effect of formaldehyde fumigation on production performance and behaviour. Formaldehyde vaporization resulted in higher weekly (days 0-6 and 21-27) and total (days 0-41) feed intake and poorer weekly (days 0-6, 7-13, 21-27 and 28-34) and overall (days 0-41) feed conversion ratios. Body weight, mortality and behaviour (eating, drinking, sitting and standing activities) were not affected by formaldehyde fumigation.
    Matched MeSH terms: Disinfectants/administration & dosage; Disinfectants/pharmacology*
  18. Lee CK, Chua YP, Saw A
    Clin Orthop Relat Res, 2012 Feb;470(2):610-5.
    PMID: 21842299 DOI: 10.1007/s11999-011-1990-z
    Pin site infection is a common problem in external fixation. Plain gauze wetted with normal saline is commonly used for a pin site dressing owing to the simplicity and low cost. Evidence to support adding an antimicrobial agent in the dressing material is lacking.
    Matched MeSH terms: Disinfectants/administration & dosage*
  19. Razak FA, Musa MY, Abusin HAM, Salleh NM
    J Coll Physicians Surg Pak, 2019 Apr;29(4):387-389.
    PMID: 30925969 DOI: 10.29271/jcpsp.2019.04.387
    Application of ozone is recommended for sterilisation in dental procedures. This study explored the antimicrobial effect of 0.1 ppm ozonated-water on selected common oral commensals. Based on deviation of their growth curves pattern upon ozone treatment, the inhibitory effect of ozone was determined. SEM examination of the ozone-treated microbes recorded its possible morphological effect. Findings suggested a bacteriostatic action of ozone when microbes were treated at the early phase, while, it was bactericidal when treated during the active phase of the growth cycle. Hence, suggesting rinsing the oral cavity with ozonated-water at 0.1 ppm immediately after tooth brushing may suppress microbial growth and slow biofilm formation. While, rinsing on already developed biofilm may result in microbial cell lysis that halted microbial growth and reduce microbial population in the biofilm. Both justify the great potential of ozone (0.1 ppm) for use as antimicrobial agent for the control of biofilm development in the oral cavity.
    Matched MeSH terms: Disinfectants/therapeutic use
  20. Pui WC, Chieng TH, Siow SL, Nik Abdullah NA, Sagap I
    Asian Pac J Cancer Prev, 2020 Oct 01;21(10):2927-2934.
    PMID: 33112550 DOI: 10.31557/APJCP.2020.21.10.2927
    BACKGROUND: Various methods have been used for treatment of hemorrhagic radiation proctitis (HRP) with variable results. Currently, the preferred treatment is formalin application or endoscopic therapy with argon plasma coagulation. Recently, a novel therapy with colonic water irrigation and oral antibiotics showed promising results and more effective compared to 4% formalin application for HRP. The study objective is to compare the effect of water irrigation and oral antibiotics versus 4% formalin application in improving per rectal bleeding due to HRP and related symptoms such as diarrhoea, tenesmus, stool frequency, stool urgency and endoscopic findings.

    METHODS: We conducted a study on 34 patients with HRP and randomly assigned the patients to two treatment arm groups (n=17). The formalin group underwent 4% formalin dab and another session 4 weeks later. The irrigation group self-administered daily rectal irrigation at home for 8 weeks and consumed oral metronidazole and ciprofloxacin during the first one week. We measured the patients' symptoms and endoscopic findings before and after total of 8 weeks of treatment in both groups.

    RESULTS: Our study showed that HRP patients had reduced per rectal bleeding (p = 0.003) in formalin group, whereas irrigation group showed reduced diarrhoea (p=0.018) and tenesmus (p=0.024) symptoms. The comparison between the two treatment arms showed that irrigation technique was better than formalin technique for tenesmus (p=0.043) symptom only.

    CONCLUSION: This novel treatment showed benefit in treating HRP. It could be a new treatment option which is safe and conveniently self-administered at home or used as a combination with other therapies to improve the treatment outcome for HRP.
    .

    Matched MeSH terms: Disinfectants/therapeutic use
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links