Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Naje AS, Chelliapan S, Zakaria Z, Abbas SA
    J Environ Manage, 2016 Jul 1;176:34-44.
    PMID: 27039362 DOI: 10.1016/j.jenvman.2016.03.034
    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.
    Matched MeSH terms: Electrocoagulation
  2. Wong JL, Tie ST, Lee J, Kannan SK, Rashid Ali MR, Ibrahim A, et al.
    Med J Malaysia, 2014 Aug;69(4):195-6.
    PMID: 25500852 MyJurnal
    Recurrent respiratory papillomatosis (RRP) is a benign disease caused by the human papilloma virus (HPV), characterized by the formation of recurrent, epithelial neoplastic lesions in the airways. While benign, they can cause significant airway obstruction in some cases. Difficulties in treatment arise from the recurrent nature of the lesions despite repeated procedures. Other known procedures that result in deep tissue damage also cause unacceptable collateral damage to the underlying airway mucosa. We describe a case of recurrent papillomatosis that was successfully treated with argon plasma coagulation ( APC) when laser and electrocautery ablation had failed in the past. After the papillomatasis was treated with APC, there is no recurrence on repeat scope at 4 months and 9 months after the initial procedure. The procedure was done as a day case and there is no complication from the procedure. The property of the APC that allows it to cause only superficial thermal damage to the tissue makes it a suitable adjunct therapy to the treatment of papillomas, which are usually superficial lesions.
    Matched MeSH terms: Electrocoagulation
  3. Nasution MA, Yaakob Z, Ali E, Tasirin SM, Abdullah SR
    J Environ Qual, 2011 Jul-Aug;40(4):1332-9.
    PMID: 21712603 DOI: 10.2134/jeq2011.0002
    Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively.
    Matched MeSH terms: Electrocoagulation/instrumentation; Electrocoagulation/methods*
  4. Bashir MJ, Mau Han T, Jun Wei L, Choon Aun N, Abu Amr SS
    Water Sci Technol, 2016;73(11):2704-12.
    PMID: 27232407 DOI: 10.2166/wst.2016.123
    As the ponding system used to treat palm oil mill effluent (POME) frequently fails to satisfy the discharge standard in Malaysia, the present study aimed to resolve this problem using an optimized electrocoagulation process. Thus, a central composite design (CCD) module in response surface methodology was employed to optimize the interactions of process variables, namely current density, contact time and initial pH targeted on maximum removal of chemical oxygen demand (COD), colour and turbidity with satisfactory pH of discharge POME. The batch study was initially designed by CCD and statistical models of responses were subsequently derived to indicate the significant terms of interactive process variables. All models were verified by analysis of variance showing model significances with Prob > F < 0.01. The optimum performance was obtained at the current density of 56 mA/cm(2), contact time of 65 min and initial pH of 4.5, rendering complete removal of colour and turbidity with COD removal of 75.4%. The pH of post-treated POME of 7.6 was achieved, which is suitable for direct discharge. These predicted outputs were subsequently confirmed by insignificant standard deviation readings between predicted and actual values. This optimum condition also permitted the simultaneous removal of NH3-N, and various metal ions, signifying the superiority of the electrocoagulation process optimized by CCD.
    Matched MeSH terms: Electrocoagulation
  5. Al-Raad AA, Hanafiah MM, Naje AS, Ajeel MA
    Environ Pollut, 2020 Oct;265(Pt B):115049.
    PMID: 32599327 DOI: 10.1016/j.envpol.2020.115049
    In this study, a novel rotating anode-based reactor (RAR) was designed to investigate its effectiveness in removing dissolved salts (i.e., Br-, Cl-, TDS, and SO42-) from saline water samples. Two configurations of an impeller's rotating anode with various operation factors, such as operating time (min), rotating speed (rpm), current density (mA/cm2), temperature (°C), pH, and inter-electrode space (cm), were used in the desalination process. The total cost consumed was calculated on the basis of the energy consumption and aluminum (Al) used in the desalination. In this respect, operating costs were calculated using optimal operating conditions. Salinity was removed electrochemically from saline water through electrocoagulation (EC). Results showed that the optimal adjustments for treating saline water were carried out at the following conditions: 150 and 75 rpm rotating speeds for the impeller's rod anode and plate anode designs, respectively; 2 mA/cm2 current density (I), 1 cm2 inter-electrode space, 25 °C temperature, 10 min operation time, and pH 8. The results indicated that EC technology with impeller plates of rotating anode can be considered a very cost-effective technique for treating saline water.
    Matched MeSH terms: Electrocoagulation
  6. Bonakdari H, Ebtehaj I, Akhbari A
    Water Sci Technol, 2017 Jun;75(12):2791-2799.
    PMID: 28659519 DOI: 10.2166/wst.2017.158
    Electrocoagulation (EC) is employed to investigate the energy consumption (EnC) of synthetic wastewater. In order to find the best process conditions, the influence of various parameters including initial pH, initial dye concentration, applied voltage, initial electrolyte concentration, and treatment time are investigated in this study. EnC is considered the main criterion of process evaluation in investigating the effect of the independent variables on the EC process and determining the optimum condition. Evolutionary polynomial regression is combined with a multi-objective genetic algorithm (EPR-MOGA) to present a new, simple and accurate equation for estimating EnC to overcome existing method weaknesses. To survey the influence of the effective variables, six different input combinations are considered. According to the results, EPR-MOGA Model 1 is the most accurate compared to other models, as it has the lowest error indices in predicting EnC (MARE = 0.35, RMSE = 2.33, SI = 0.23 and R2 = 0.98). A comparison of EPR-MOGA with reduced quadratic multiple regression methods in terms of feasibility confirms that EPR-MOGA is an effective alternative method. Moreover, the partial derivative sensitivity analysis method is employed to analyze the EnC variation trend according to input variables.
    Matched MeSH terms: Electrocoagulation
  7. Al Aradi IK
    Dermatol Surg, 2006 Oct;32(10):1244-50.
    PMID: 17034373
    Management of periorbital syringomas is problematic and avoided by many inexperienced physicians. The medical literature presently prefers CO(2) laser resurfacing to many other modalities, but the subject of electrosurgery has not been well explored.
    Matched MeSH terms: Electrocoagulation/instrumentation*
  8. Naje AS, Ajeel MA, Ali IM, Al-Zubaidi HAM, Alaba PA
    Water Sci Technol, 2019 Aug;80(3):458-465.
    PMID: 31596257 DOI: 10.2166/wst.2019.289
    In this work, landfill leachate treatment by electrocoagulation process with a novel rotating anode reactor was studied. The influence of rotating anode speed on the removal efficiency of chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS) of raw landfill leachate was investigated. The influence of operating parameters like leachate pH, leachate temperature, current, and inter-distance between the cathode rings and anode impellers on the electrocoagulation performance were also investigated. The results revealed the optimum rotating speed is 150 rpm and increasing the rotating speed above this value led to reducing process performance. The leachate electrocoagulation treatment process favors the neutral medium and the treatment performance increases with increasing current intensity. Furthermore, the electrocoagulation treatment performance improves with increasing leachate temperature. However, the performance reduces with increasing inter-electrode distance.
    Matched MeSH terms: Electrocoagulation
  9. Asaithambi P, Aziz ARA, Sajjadi B, Daud WMABW
    Environ Sci Pollut Res Int, 2017 Feb;24(6):5168-5178.
    PMID: 27221586 DOI: 10.1007/s11356-016-6909-5
    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm(2)), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm(2), electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.
    Matched MeSH terms: Electrocoagulation/methods*
  10. Deori A, Gupta N, Gupta AK, Yelamanchi R, Agrawal H, Durga CK
    Malays J Med Sci, 2021 Feb;28(1):97-104.
    PMID: 33679225 DOI: 10.21315/mjms2021.28.1.12
    Background: Axillary dissection is one of the important components of modified radical mastectomy (MRM). The present study was conducted to compare surgical outcomes by using monopolar electrocautery and ultrasonic dissector for axillary dissection in MRM.

    Methods: A parallel randomised controlled single blinded study was conducted with a sample size of 70 patients who were randomised into two groups. One group underwent MRM using ultrasonic dissector (Group A) and the other one using electrocautery (Group B). Intra- and post-operative outcomes were compared.

    Results: Group A had an average operating time of 30.86 min, which was statistically less than that of Group B. The mean mop count and the daily drain output in Group A were less as compared to Group B and the differences were statistically significant. Drain was removed early in Group A as compared to Group B. However, post-operative pain scores and seroma formation were not statistically significant among the two groups.

    Conclusion: Ultrasonic dissector group had significantly lesser intra-operative bleeding, operating time and post-operative drain output when compared to electrocautery group. However, the two groups had no significant difference in post-operative pain scores and seroma formation.

    Matched MeSH terms: Electrocoagulation
  11. Goh LC, Wan MH, Shashi G, Elangkumaran S
    Iran J Otorhinolaryngol, 2018 Jul;30(99):225-229.
    PMID: 30083529
    Introduction: This study aims to report a rare case of a respiratory epithelial adenomatoid hamartoma (REAH) of the lateral nasal wall that had initially presented as a fungating mass, similar to that of a sinonasal malignancy, and its complete removal from the lateral nasal wall.

    Case Report: We report the case of a 58-year-old woman who presented to us with a chief complaint of recurrent right-sided epistaxis and nasal blockage for the past 4 months, which was progressively worsening. Histopathological examination confirmed the presence of a REAH instead of a sinonasal malignancy. The tumor was surgically excised from the lateral nasal wall using electrocautery under endoscopic guidance. The patient was then carefully followed-up after surgery, and the wound was successfully healed 3 months after the initial surgery. There was no evidence of recurrence 6 months after the initial surgery.

    Conclusion: This case demonstrates the rare presentation of a REAH, which had arisen from the lateral nasal wall. Clinically, it is difficult to distinguish a REAH from a more notorious mass such as a sinonasal malignancy. Therefore, biopsy is mandatory in all cases of lateral nasal mass in order to rule out malignancy before confirming nasal REAH. Fortunately, as seen in this case, a lateral nasal REAH, once diagnosed, can be safely and easily removed from the lateral nasal wall using electrocautery with good surgical outcomes and a low rate of recurrence.

    Matched MeSH terms: Electrocoagulation
  12. Mousazadeh M, Niaragh EK, Usman M, Khan SU, Sandoval MA, Al-Qodah Z, et al.
    Environ Sci Pollut Res Int, 2021 Aug;28(32):43143-43172.
    PMID: 34164789 DOI: 10.1007/s11356-021-14631-w
    Electrocoagulation (EC) is one of the emerging technologies in groundwater and wastewater treatment as it combines the benefits of coagulation, sedimentation, flotation, and electrochemical oxidation processes. Extensive research efforts implementing EC technology have been executed over the last decade to treat chemical oxygen demand (COD)-rich industrial wastewaters with the aim to protect freshwater streams (e.g., rivers, lakes) from pollution. A comprehensive review of the available recent literature utilizing EC to treat wastewater with high COD levels is presented. In addition, recommendations are provided for future studies to improve the EC technology and broaden its range of application. This review paper introduces some technologies which are often adopted for industrial wastewater treatment. Then, the EC process is compared with those techniques as a treatment for COD-rich wastewater. The EC process is considered as the most privileged technology by different research groups owing to its ability to deal with abundant volumes of wastewater. After, the application of EC as a single and combined treatment for COD-rich wastewaters is thoroughly reviewed. Finally, this review attempts to highlight the potentials and limitations of EC. Related to the EC process in batch operation mode, the best operational conditions are found at 10 V and 60 min of voltage and reaction time, respectively. These last values guarantee high COD removal efficiencies of > 90%. This review also concludes that considerably large operation costs of the EC process appears to be the serious drawback and renders it as an unfeasible approach for handling of COD rich wastewaters. In the end, this review has attempted to highlights the potential and limitation of EC and suggests that vast notably research in the field of continuous flow EC system is essential to introduce this technology as a convincing wastewater technology.
    Matched MeSH terms: Electrocoagulation
  13. Al-Raad AA, Hanafiah MM
    J Environ Manage, 2021 Dec 15;300:113696.
    PMID: 34509809 DOI: 10.1016/j.jenvman.2021.113696
    Electrocoagulation (ECoag) technique has shown considerable potential as an effective method in separating different types of pollutants (including inorganic pollutants) from various sources of water at a lower cost, and that is environmentally friendly. The EC method's performance depends on several significant parameters, including current density, reactor geometry, pH, operation time, the gap between electrodes, and agitation speed. There are some challenges related to the ECoag technique, for example, energy consumption, and electrode passivation as well as its implementation at a larger scale. This review highlights the recent studies published about ECoag capacity to remove inorganic pollutants (including salts), the emerging reactors, and the effect of reactor geometry designs. In addition, this paper highlights the integration of the ECoag technique with other advanced technologies such as microwave and ultrasonic to achieve higher removal efficiencies. This paper also presents a critical discussion of the major and minor reactions of the electrocoagulation technique with several significant operational parameters, emerging designs of the ECoag cell, operating conditions, and techno-economic analysis. Our review concluded that optimizing the operating parameters significantly enhanced the efficiency of the ECoag technique and reduced overall operating costs. Electrodes geometry has been recommended to minimize the passivation phenomenon, promote the conductivity of the cell, and reduce energy consumption. In this review, several challenges and gaps were identified, and insights for future development were discussed. We recommend that future studies investigate the effect of other emerging parameters like perforated and ball electrodes on the ECoag technique.
    Matched MeSH terms: Electrocoagulation
  14. Leung AK, Barankin B, Leong KF, Hon KL
    Drugs Context, 2018;7:212563.
    PMID: 30622585 DOI: 10.7573/dic.212563
    Background: Penile warts are the most common sexually transmitted disease in males. Clinicians should be familiar with the proper evaluation and management of this common condition.

    Objective: To provide an update on the current understanding, evaluation, and management of penile warts.

    Methods: A PubMed search was completed in Clinical Queries using the key terms 'penile warts' and 'genital warts'. The search strategy included meta-analyses, randomized controlled trials, clinical trials, observational studies, and reviews.

    Results: Penile warts are caused by human papillomavirus (HPV), notably HPV-6 and HPV-11. Penile warts typically present as asymptomatic papules or plaques. Lesions may be filiform, exophytic, papillomatous, verrucous, hyperkeratotic, cerebriform, fungating, or cauliflower-like. Approximately one-third of penile warts regress without treatment and the average duration prior to resolution is approximately 9 months. Active treatment is preferable to watchful observation to speed up clearance of the lesions and to assuage fears of transmission and autoinoculation. Patient-administered therapies include podofilox (0.5%) solution or gel, imiquimod 3.75 or 5% cream, and sinecatechins (polypheron E) 15% ointment. Clinician-administered therapies include podophyllin, cryotherapy, bichloroacetic or trichloroacetic acid, oral cimetidine, surgical excision, electrocautery, and carbon dioxide laser therapy. Patients who do not respond to first-line treatments may respond to other therapies or a combination of treatment modalities. Second-line therapies include topical/intralesional/intravenous cidofovir, topical 5-fluorouracil, and topical ingenol mebutate.

    Conclusion: No single treatment has been shown to be consistently superior to other treatment modalities. The choice of the treatment method should depend on the physician's comfort level with the various treatment options, the patient's preference and tolerability of treatment, and the number and severity of lesions. The comparative efficacy, ease of administration, adverse effects, cost, and availability of the treatment modality should also be taken into consideration.

    Matched MeSH terms: Electrocoagulation
  15. Lim YH, Ng SP, Ng PH, Tan AE, Jamil MA
    J Obstet Gynaecol Res, 2007 Dec;33(6):855-62.
    PMID: 18001454
    Ectopic pregnancy is conventionally managed by laparoscopic salpingectomy. Electrocautery has been used widely to secure hemostasis during salpingectomy. However, this method is associated with a risk of thermal injury to the visceral organs. Endoloop, a pre-tied suture used in laparoscopic surgery may be an alternative treatment tool and its potential use in the management of ectopic pregnancy is explored here. Our study aims to compare the effectiveness of the endoloop technique to electrocautery during laparoscopic salpingectomy for tubal pregnancy.
    Matched MeSH terms: Electrocoagulation*
  16. Isa MH, Ezechi EH, Ahmed Z, Magram SF, Kutty SR
    Water Res, 2014 Mar 15;51:113-23.
    PMID: 24412846 DOI: 10.1016/j.watres.2013.12.024
    This work investigated the removal of boron from wastewater and its recovery by electrocoagulation and hydrothermal mineralization methods respectively. The experimental design was developed using Box-Behnken Model. An initial study was performed based on four preselected variables (pH, current density, concentration and time) using synthetic wastewater. Response surface methodology (RSM) was used to evaluate the effect of process variables and their interaction on boron removal. The optimum conditions were obtained as pH 6.3, current density 17.4 mA/cm(2), and time 89 min. At these applied optimum conditions, 99.7% boron removal from an initial concentration of 10.4 mg/L was achieved. The process was effectively optimized by RSM with a desirability value of 1.0. The results showed that boron removal efficiency enhanced with increase in current density and treatment time. Removal efficiency also increased when pH was increased from 4 to 7 and subsequently decreased at pH 10. Adsorption kinetics study revealed that the reaction followed pseudo second order kinetic model; evidenced by high correlation and goodness of fit. Thermodynamics study showed that mechanism of boron adsorption was chemisorption and the reaction was endothermic in nature. Furthermore, the adsorption process was spontaneous as indicated by negative values of the adsorption free energy. Treatment of real produced water using electrocoagulation resulted in 98% boron removal. The hydrothermal mineralization study showed that borate minerals (Inyoite, Takadaite and Nifontovite) can be recovered as recyclable precipitate from electrocoagulation flocs of produced water.
    Matched MeSH terms: Electrocoagulation/methods*
  17. Danial R, Sobri S, Abdullah LC, Mobarekeh MN
    Chemosphere, 2019 Oct;233:559-569.
    PMID: 31195261 DOI: 10.1016/j.chemosphere.2019.06.010
    In this study, the performance of glyphosate removal in an electrocoagulation batch with two electrodes formed by the same metal type, consisting of aluminum, iron, steel and copper have been compared. The aim of this study intends to remove glyphosate from an aqueous solution by an electrocoagulation process using metal electrode plates, which involves electrogeneration of metal cations as coagulant agents. The production of metal cations showed an ability to bind together to form aggregates of flocs composed of a combination of glyphosate and metal oxide. Electrocoagulation using aluminum electrodes indicated a high percentage removal of glyphosate, 94.25%; followed by iron electrodes, 88.37%; steel electrodes, 62.82%; and copper electrodes, 46.69%. The treated aqueous solution was then analyzed by Fourier Transform Infrared Spectroscopy. Percentages of Carbon, Hydrogen, Nitrogen, Sulfur remaining in the treated aqueous solution after the electrocoagulation process have been determined. The treated water and sludge were characterized and the mechanism of the overall process was concluded as an outcome. An X-Ray Diffraction analysis of dried sludge confirmed that new polymeric compounds were formed during the treatment. The sludge composed of new compounds were also verified the removals. This study revealed that an electrocoagulation process using metal electrodes is reliable and efficient.
    Matched MeSH terms: Electrocoagulation/methods
  18. Rajendren, S. K., Krishnan, K., Ganesh, T. N., Roslan, N. S., Hashim, N. A., Mohamad, M. A.
    Jurnal Veterinar Malaysia, 2019;31(2):19-22.
    MyJurnal
    A 5-year-old Mongrel was brought presented with the complaint of having serosanguineous discharge from penis for a month since adoption. Physical examination revealed cauliflower-like mass at the bulbus glandis. Presence of numerous anisokaryotic and anisocytotic round to oval histiocytes with multivacuolated cytoplasm from cytology, an evidence of canine transmissibale venereal tumour (CTVT). The mass was successfully surgically resected using electrocautery and was in remission for 12 months (since January 2019).
    Matched MeSH terms: Electrocoagulation
  19. Suresh N, Chandrasekaran B, Muthusamy S, Kannan S, Muthu K
    Singapore Dent J, 2015 Dec;36:39-43.
    PMID: 26684495 DOI: 10.1016/j.sdj.2014.11.004
    BACKGROUND: Application of principles of electrocautery for hemostasis dates back to prehistoric times. Its modern implementation in various fields of general and head and neck surgeries have been well documented. However its usage in minor oral surgical procedures has gained popularity only recently. Complications associated with electro-surgery in the dental field are relatively rare and there is insufficient literature on its management.

    CASE REPORT: We present a case report on management of an electrosurgery induced osteonecrosis involving maxillary alveolus of left premolars.

    DISCUSSION: Inadvertent contact of the electrosurgery tip on bone can result in necrosis making it necessary to remove the sequestrum and graft the defect. Platelet rich fibrin in combination with bone grafts have been well documented to provide successful periodontal regeneration.

    CLINICAL IMPLICATIONS: Our aim of presenting this report is to create awareness among the health care providers regarding electrosurgical injuries. To our knowledge, this is the first time platelet rich fibrin has been used in the management of intraoral electrosurgical injury. Combining bone grafts with platelet rich fibrin is a good alternative as it can be done with relative ease and predictable outcome.

    Matched MeSH terms: Electrocoagulation
  20. Tan LS, Daud MH, Nasirudin N
    J Hand Surg Asian Pac Vol, 2018 Dec;23(4):577-580.
    PMID: 30428790 DOI: 10.1142/S2424835518720335
    Pyogenic granuloma, also known as lobular capillary hemangioma, is a benign vascular lesion of the skin or mucous membrane with rapid growth or repetitive trauma. Rarely seen in adult, its management varies and surgical intervention is usually common. We report a case of pyogenic granuloma of the right index finger in a 46-year-old gentleman who presented with painless swelling of the right index finger after a trivial injury. Wedge biopsy confirmed the diagnosis and excision of the granuloma measuring 3 cm × 3 cm × 2 cm was done with curettage and electrocautery over the base of granuloma. The wound subsequently healed well with good functional and aesthetic outcome.
    Matched MeSH terms: Electrocoagulation/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links