Displaying publications 1 - 20 of 152 in total

Abstract:
Sort:
  1. Sia KJ, Ashok GD, Ahmad FM, Kong CK
    Hong Kong Med J, 2013 Dec;19(6):542-4.
    PMID: 24310662 DOI: 10.12809/hkmj133668
    We describe a rare case of aorto-oesophageal fistula and aortic pseudoaneurysm in a middle-aged man, who presented with chest pain and haematemesis 1 week after swallowing a fish bone. Oesophagogastroduodenoscopy and computed tomographic angiography findings were consistent with oesophageal perforation, proximal descending aortic pseudoaneurysm, and aorto-oesophageal fistula. Thoracic endovascular aortic repair was performed. The patient died from severe mediastinal sepsis. Early surgical intervention and broad-spectrum antibiotic therapy are crucial in preventing life-threatening mediastinal infection.
    Matched MeSH terms: Foreign Bodies/complications*
  2. Vinuthinee N, Azreen-Redzal A, Juanarita J, Zunaina E
    Int Med Case Rep J, 2015;8:47-50.
    PMID: 25709507 DOI: 10.2147/IMCRJ.S75198
    We report a rare case of sling shot injury that presented with a gunshot-like wound with preseptal cellulitis, in a toddler. An 11-month-old Malay child presented with a gunshot-like wound over the forehead following sling shot injury. On examination, he had a deep circular laceration wound over the forehead, measuring 2.0 cm in diameter, with minimal bleeding. There was no obvious foreign body seen inside the wound and no palpable foreign body surrounding the wound. The gunshot-like wound was associated with left preseptal cellulitis. A skull X-ray showed a white opaque foreign body in the left frontal bone. Computed tomography (CT) scan of orbit and brain revealed a left comminuted fracture of the left orbital roof, and left frontal brain contusion with prelesional edema. Wound exploration was performed and revealed a 0.5 cm unshattered marble embedded in the left frontal bone. The marble and bone fragments were removed. The left preseptal cellulitis responded well to intravenous antibiotic and topical antibiotic.
    Matched MeSH terms: Foreign Bodies
  3. Vinodh VP, Sellamuthu P, Harun RH, Zenian MS
    Med J Malaysia, 2014 Apr;69(2):89-91.
    PMID: 25241819 MyJurnal
    Intraorbital foreign body (IOFB) has been a rare phenomenon in the cases of gunshot wounds and always represents a dilemma in medical management. In Sabah, this scenario is becoming common as there is still certain population in the interiors who owns self made guns for hunting. They either present with self inflicted gunshot injuries or after being mistakenly shot while hunting. There are very few articles on this topic especially when it is located posteriorly in the orbit and occurs without visual impairment. This case reports the challenges faced in the management of the patient with a posteriorly located metallic IOFB. The appropriate management of the patient is discussed based on several international literatures. Author describes a 37 years old male farmer, who was referred from a nearby district hospital after he sustained gunshot injuries to his face and scalp. Urgent computed tomography (CT) scan showed that bullet pellets were at the left orbital floor, the left mandible and the left frontal bone. All bullet pellets were located extracranially only without intracranial involvement. Patient clinically does not have any neurologic deficit and without any visual impairment, thus he refused any surgical intervention. As there is no proper guideline in managing such cases, decision was made based on evidences from international literatures. It was concluded that metallic IOFB located in the posterior orbit may be conservatively managed with observation and regular follow-ups as they are well-tolerated and does not cause much impact on visual deterioration unless inflammation, infection, optic neuropathy or functional deficit occurs. This avoids unnecessary surgery and prevents risk of iatrogenic injury to the eye.
    Matched MeSH terms: Eye Foreign Bodies
  4. Kunaparaju K, Shetty K, Jathanna V, Nath K, M R
    Patient Saf Surg, 2021 Jan 05;15(1):1.
    PMID: 33402200 DOI: 10.1186/s13037-020-00273-3
    BACKGROUND: Accidental ingestion of a dental bur during the dental procedure is a rare, but a potentially serious complication. Early recognition and foreign body retrieval is essential to prevent adverse patient outcomes.

    CASE PRESENTATION: A 76-year old male patient, presented to the department with a chief complaint of sensitivity in his upper right back tooth due to attrition. After assessing the pulp status, root canal therapy was planned for the tooth. During the procedure, it was noticed that the dental bur slipped out of the hand piece and the patient had accidentally ingested it. The patient was conscious and had no trouble while breathing at the time of ingestion of the bur although he had mild cough which lasted for a short duration. The dental procedure was aborted immediately and the patient was taken to the hospital for emergency care. The presence and location of the dental bur was confirmed using chest and abdominal x-rays and it was subsequently retrieved by esophagogastroduodenoscopy (EGD) procedure under general anaesthesia on the same day as a part of the emergency procedure. The analysis of this case reaffirms the importance of the use of physical barriers such as rubber dams and gauze screens as precautionary measures to prevent such incidents from occurring.

    CONCLUSION: Ingestion of instruments are uncertain and hazardous complications to encounter during a dental procedure. The need for physical barrier like rubber dam is mandatory for all dental procedures. However, the dentist should be well trained to handle such medical emergencies and reassure the patient by taking them into confidence. Each incident encountered should be thoroughly documented to supply adequate guidance for treatment aspects. This would fulfil the professional responsibilities of the dentist/ clinician and may help avoid possible legal and ethical issues. This case report emphasizes on the need for the usage of physical barriers during dental procedures in order to avoid medical emergencies.

    Matched MeSH terms: Foreign Bodies
  5. Teng TS, Ishak NL, Subha ST, Bakar SA
    EXCLI J, 2019;18:223-228.
    PMID: 31217785 DOI: 10.17179/excli2018-1971
    CSF leak in penetrating skull base injury is relatively rare compared to close head injury involving skull base fracture. We report a 5-year-old boy presented with epistaxis and impacted pencil into the left nostril. The child was hemodynamically stable without any neurological deficit. Intraoperatively, there was a nasal septal defect posteriorly with anterior skull base fracture associated with CSF leak. The pencil was removed from the left nostril and the CSF leak was repaired using harvested abdominal fat under the same setting. Computed Tomography (CT) of the brain showed right cribriform plate fracture with small pneumocranium. Postoperatively, a prophylactic antibiotic was given for seven days and he was discharged well. Subsequent clinic visits up to one-year postoperative period showed no recurrence of the CSF leak. History taking, physical examination and CT imaging give valuable diagnostic values in managing the penetrating skull base injury. Early intervention for removal of the foreign body and repair of the CSF leak is advocated to prevent catastrophic complication.
    Matched MeSH terms: Foreign Bodies
  6. Wong, Y.P., Tan, G.C.
    Medicine & Health, 2018;13(2):223-228.
    MyJurnal
    Mature cystic teratoma is the commonest ovarian germ cell tumour which accounts for 70% of all benign ovarian neoplasms in the reproductive age groups. Being a pluripotent germ cell tumour, mature cystic teratoma has at least two out of three mature embryonic germ cell components: ectoderm, mesoderm and endoderm. The presence of multiple cystic spaces within the tumour wall, also known as pneumatosis cystoides-like appearance is rarely described but a characteristic feature in cystic teratoma of the ovary. Currently, there is little information concerning the mechanism of its formation. Herein, we described an unusual case of ovarian mature cystic teratoma in a 31-year-old pregnant female with multiple sieve-like areas resembling pneumatosis cystoides of the intestine. Macroscopic and histological examination of the ovary revealed features diagnostic of mature cystic teratoma. Intriguingly, multiple cystic spaces of variable sizes were found within the cyst wall histologically. They were lined partially or completely by foamy histiocytes and foreign body type multinucleated giant cells, exhibiting strong CD68 immunoreactivity. Vascular endothelial markers (CD31 and CD34) and epithelial marker (cytokeratin AE1/AE3) were negative. A diagnosis of mature cystic teratoma with pneumatosis cystoides-like feature was rendered. The patient was discharged well with no signs and symptoms of early labour. The etiopathogenesis of this intriguing histological feature is briefly discussed in this article.
    Matched MeSH terms: Foreign Bodies
  7. Nasir ZM, Subha ST
    Int Arch Otorhinolaryngol, 2021 Apr;25(2):e193-e199.
    PMID: 33968219 DOI: 10.1055/s-0040-1709739
    Introduction  Foreign body aspiration is a leading cause of accidental death in children. Clinical presentation varies from non-specific respiratory symptoms to respiratory failure making diagnosis challenging. Objective  To review pediatric patients who underwent bronchoscopy due to suspicion of foreign body aspiration at a tertiary center in Malaysia. Methods  We retrospectively studied patients < 11 years old who underwent bronchoscopy from 2008 to 2018. Results  Over the 10-year period, 20 patients underwent bronchoscopy, and 16 were found to have foreign body aspiration with equal gender distribution. The most common age group was < 3 years old (75%). The most common clinical presentations were choking (82%) and stridor (31%). Foreign bodies were removed using flexible bronchoscope in 8 cases (50%), and difficulties were encountered in 6 cases (75%). Rigid ventilating bronchoscope was used in 8 cases (50%) with no difficulty. The most common object found was peanut (19%). The majority of foreign bodies were lodged in the right bronchus (43%). Eight patients (80%) received delayed treatment due to delayed diagnosis. The length of hospital stay was longer in the younger age groups. Conclusion  Clinical presentation and chest radiograph findings were comparable across all age groups. The most difficulties encountered during foreign body removal were via flexible bronchoscope, in children < 3 years old. There was no significant correlation between age and type of foreign body aspiration. The majority of patients who received delayed treatment were < 3 years old. The length of hospital stay was longer in the younger age groups.
    Matched MeSH terms: Foreign Bodies
  8. Khairidzan, M.K., Fatimah, S.S., Thangasamy, V.K.
    MyJurnal
    Pterygium is a common external eye problem. It is more frequently seen in tropical areas regions where exposure to ultraviolet sunlight is high. Clinically, a pterygium is a wing shaped fibrovascular growth arising from the bulbar conjunctiva onto the superficial cornea. Complications of pterygium include decreased in visual acuity, dryness, foreign body sensation and persistent redness. Surgical management is the mainstay of treatment for this condition. Numerous surgical techniques have been described in the treatment of pterygium. They include the bare sclera technique, simple direct conjunctival closure, rotational conjunctival graft and conjunctival autograft. Additional treatment to some of these techniques may include the use of beta particle therapy and antimetabolite therapy. Despite the wide range of surgical procedures described for its treatment, the main concern from these procedures has been the recurrence, which could be as high as 30% to 70%. Recurrent pterygium is often accompanied by increased conjunctival inflammation and accelerated corneal involvement. Repeated surgical procedures often only worsen the situation, as loss of conjunctival tissue and scarring can result in obliteration of the fornices and mechanical restriction of extraocular movements, with clinically significant diplopia. In Hospital Tengku Ampuan Afzan, pterygium excision is the most common surgical procedure after cataract extraction. We reviewed patients who had undergone pterygium surgery in HTAA in order to determine the most effective surgical method that could minimize recurrence. PURPOSE: To compare success rates of various excision techniques performed for primary and recurrent pterygium in Hospital Tengku Ampuan Afzan, Kuantan, Pahang.
    METHODS: The outcome of 47 cases of pterygia (44 primary and 3 recurrent) excised with various techniques between January 2004 to September 2004 was retrospectively reviewed. Six clinical specialists and four trainees performed the surgical procedures. Outcome was evaluated in terms of recurrence of pterygia onto the cornea. RESULTS: The mean follow up was 3.04 months (range, 1-7 months). All pterygia were morphologically graded as intermediate or fleshy type except one. Four types of pterygium excision techniques were performed. Twenty-four cases had bare sclera, seventeen cases had conjunctival autograft transplantation, six cases had direct conjunctival closure and one had amniotic membrane transplantation done. Recurrence of pterygia occurred in thirteen eyes. Twelve cases from primary pterygia group and one case from recurrent group recurred. Recurrence rate was noted to be higher in direct conjunctival closure (4 out of 6 cases) and lowest in conjunctival autograft transplantation (2 out of 17 cases). Recurrence rate for bare sclera technique was noted to rank second in this study (6 out of 24 cases). In five cases of recurrence, subconjunctival tissue invasions were more than 1 mm but further surgical interventions were not needed at the time of this review was done. CONCLUSIONS: Conjunctival autografting was found to have less recurrent rate when compared with other techniques. The bare sclera technique was quoted to be associated with higher recurrence rate in other literatures. Interestingly in our series, recurrence rate for direct conjunctival closure technique was higher when compared to the former technique. This may be related to inadequate excision of pterygia tissue, which led to direct apposition of abnormal tissue to the cornea in the direct conjunctival closure technique. Even though the bare sclera technique is associated with a higher recurrence rate, it is still the preferred excision technique. This could be because it is less time consuming and technically easier to perform. Based on this study, conjunctival autografting should be the surgical procedure of choice for pteryigum in order to minimise the risk of recurrence.
    Matched MeSH terms: Foreign Bodies
  9. Logeswary, K., Jemaima Che-Hamzah, Aida Zairani, M.Z.
    MyJurnal
    A 47-year-old healthy Indonesian gentleman, presented with blurring of vision on the left eye associated with pain
    and redness after history of foreign body entering the eye. A general practitioner prescribed him some eye drops;
    however, his symptoms worsened. A corneal laceration wound measuring 0.5 x 3.5mm with a large stromal abscess
    measuring 9.0 x 5.0mm with flat anterior chamber was seen on the left eye. Emergency corneal T&S revealed a large
    descemetocele and cyanoacrylate corneal glue was applied on the area. C&S showed Pseudomonas aeruginosa.
    Patient was subsequently undergone penetrating keratoplasty as a definitive measure. This case highlights the rapid
    progression of pseudomonas keratitis, presented with a large descemetocele, which can be mistaken as an infected
    corneal laceration wound. Corneal cyanoacrylate glueing together with corneal suturing is a viable temporary method
    for large descemetoceles awaiting definitive surgery.
    Matched MeSH terms: Foreign Bodies
  10. Thevi T, Reddy SC
    MyJurnal
    Ocular injuries or trauma to the eye can be caused by variety of objects resulting in a spectrum of lesions in the eye. We did a Pubmed/Google/Science Direct search to review the spectrum of ocular injuries in Malaysia. In our review, we included 28 papers providing information on ocular injuries which were published from Malaysia during the period 1991-2016 in different medical journals. Prevalence was more among males with an average age of 35 years. Among adults they were more common in the workplace but in children it occurred at home. Few wore protective glasses at work. The mode of injury was due to sharp objects hitting the eye, motor vehicle and domestic accidents, firecrackers, chemicals and rarer causes like superglue and durian fruit. Prognostic factors for outcome were the initial visual acuity, length of the wound, associated factors like hyphaema, intraocular foreign body and vitreous prolapse. Missing the diagnosis of perforation of the eyeball is possible without eliciting a proper history. Protective devices must be worn to prevent injuries. Display of health education charts showing the effect of injuries in the eye and their preventive measures in health centres, private hospitals, schools, factories and sports centres will increase the awareness of public about the ocular injuries. It is important to diagnose the tissues involved in ocular trauma by the general practitioners and primary care physicians and refer the patients to the Ophthalmologist urgently for treatment to salvage vision. Compensation mechanisms should then be put forth in terms of rehabilitation and for monetary loss.
    Matched MeSH terms: Eye Foreign Bodies
  11. Mohd Ariff NA, Mazlan MZ, Mat Hassan ME, Seevaunnamtum PA, Wan Muhd Shukeri WF, Nik Mohamad NA, et al.
    Respir Med Case Rep, 2018;23:93-95.
    PMID: 29387523 DOI: 10.1016/j.rmcr.2018.01.001
    Introduction: Bronchoscopy is a commonly used procedure in the context of aspiration in the Intensive Care Unit setting. Despite its ability to remove mucus plug and undigested gastric contents, aspiration of gastric content into the trachea is one of the most feared complications among anesthesiologist.

    Discussion: The scenario is made worst if the aspiration causes acute hypoxemic respiratory failure immediately post intubation. However, in the event of desaturation, the quick decision to proceed with bronchoscopy is a challenging task to the anesthesiologist without knowing the causes.

    Case presentation: We present a case of a 12-year-old boy who had a difficult-to-ventilate scenario post transferring and immediately connected to ventilator in operation theatre (OT) from portable ventilator from the emergency department. She was successfully managed by bronchoscopy.

    Conclusion: Special attention should be given to the difficult-to-ventilate scenario post intubation of traumatic brain injury patient prior to operation. Prompt diagnosis and bronchoscope-assisted removal of foreign body was found to be a successful to reduce morbidity and mortality.

    Matched MeSH terms: Foreign Bodies
  12. Tan AK, Pall S
    Med J Malaysia, 2011 Oct;66(4):284-5.
    PMID: 22299542 MyJurnal
    Matched MeSH terms: Eye Foreign Bodies/complications*
  13. Sharma HS, Kurl DN, Hamzah M
    Auris Nasus Larynx, 1998 Dec;25(4):403-6.
    PMID: 9853664
    Retropharyngeal abscess (RPA) is relatively rare today. A study of 17 cases of RPA treated at our hospital in the past 10 years showed a shift in the disease from children below 6 years of age (41%) to older children and adults (58%). Upper respiratory tract infection (URTI) was found to be the commonest (52%) aetiological predisposing factor in all age groups. Other aetiological factors were septicaemia (11%) in children below the age of 6 years and trauma due to foreign body (35%) in the older children and adult age groups. Klebsiella, Staphylococcus and Streptococcus were the commonest species of microorganisms grown from pus. The changing clinical trends, microbiology, choice of antibiotics, usefulness of radiology, and complications of this potentially fatal illness are discussed.
    Matched MeSH terms: Foreign Bodies/complications
  14. Masaany M, Marina MB, Asma A, Sani A
    J Laryngol Otol, 2009 Jun;123(6):680-2.
    PMID: 18544175 DOI: 10.1017/S0022215108002958
    To demonstrate a simple, practical, cheap method of preventing potentially fatal aspiration of a dislodged voice prosthesis; this method was developed by a laryngectomised patient.
    Matched MeSH terms: Foreign Bodies/prevention & control*
  15. Farouk A, Abdullah J
    Minim Invasive Neurosurg, 1998 Jun;41(2):74-8.
    PMID: 9651914
    The first endoscopic procedure done in Malaysia using the Caemaert-Abdullah method is reported and the followup results showed an excellent neurosurgical outcome. A 16-year-old girl with an aqueduct stenosis was operated on using a free-hand, computer-assisted endoscopic method where a third ventriculostomy was done. This was the first case being carried out in the Hospital Universiti Sains Malaysia. The next two cases were a suprasellar pituitary cyst in an elderly man and a child with an obstructive hydrocephalus who was previously shunted which became infected. Both endoscopic procedures, extirpation of the cyst using a Nd:Yag laser and a third ventriculostomy, respectively, were done under general anaesthesia in the supine position. Follow-up revealed a transient diabetes insipidus in all three cases up to 48 hours after the operation which resolved spontaneously. The fourth case involved an endoscopic removal of retained ventricular catheter after rectal migration of a shunt in an eight-year-old girl with congenital hydrocephalus. The fifth was a free-hand endoscopy with perforation of multiple brain septae in a ten-month-old baby with hydrocephalus secondary to meningitis. The final outcomes for all the cases were favourable hence we conclude that endoscopic neurosurgery is a safe procedure and hope that more neurosurgeons will continue to use this method, especially for the management of intraventricular cyst and hydrocephalus and especially in South East Asia.
    Matched MeSH terms: Foreign Bodies/surgery
  16. Chee Pin Chee
    Med J Malaysia, 1987 Dec;42(4):309-13.
    PMID: 3331410
    An unusual case of proximal migration of a Hakim's valve intracranially into a porencephalic cyst two years after insertion of the ventriculo-peritoneal shunt in a neonate is reported. The underlying cause is discussed. It is recommended that all shunt should be anchored with nonabsorbable suture material properly on to the pericranium.
    Matched MeSH terms: Foreign Bodies/diagnosis*
  17. Yoon C, Nam KC, Lee YK, Kang Y, Choi SJ, Shin HM, et al.
    J Korean Med Sci, 2019 Oct 14;34(39):e255.
    PMID: 31602825 DOI: 10.3346/jkms.2019.34.e255
    BACKGROUND: Medical device adverse event reporting is an essential activity for mitigating device-related risks. Reporting of adverse events can be done by anyone like healthcare workers, patients, and others. However, for an individual to determine the reporting, he or she should recognize the current situation as an adverse event. The objective of this report is to share observed individual differences in the perception of a medical device adverse event, which may affect the judgment and the reporting of adverse events.

    METHODS: We trained twenty-three participants from twelve Asia-Pacific Economic Cooperation (APEC) member economies about international guidelines for medical device vigilance. We developed and used six virtual cases and six questions. We divided participants into six groups and compared their opinions. We also surveyed the country's opinion to investigate the beginning point of 'patient use'. The phases of 'patient use' are divided into: 1) inspecting, 2) preparing, and 3) applying medical device.

    RESULTS: As for the question on the beginning point of 'patient use,' 28.6%, 35.7%, and 35.7% of participants provided answers regarding the first, second, and third phases, respectively. In training for applying international guidelines to virtual cases, only one of the six questions reached a consensus between the two groups in all six virtual cases. For the other five questions, different judgments were given in at least two groups.

    CONCLUSION: From training courses using virtual cases, we found that there was no consensus on 'patient use' point of view of medical devices. There was a significant difference in applying definitions of adverse events written in guidelines regarding the medical device associated incidents. Our results point out that international harmonization effort is needed not only to harmonize differences in regulations between countries but also to overcome diversity in perspectives existing at the site of medical device use.

    Matched MeSH terms: Foreign Bodies/etiology
  18. Ooi BP, Hassan MR, Kiew KK, Chin KL, Zalwani Z
    Gastrointest Endosc, 2010 Dec;72(6):1315-6.
    PMID: 20561623 DOI: 10.1016/j.gie.2010.03.1053
    Matched MeSH terms: Foreign Bodies/diagnosis*
  19. Yaroko A, Mohamad I, Hashim H
    Malays Fam Physician, 2014;9(1):30-2.
    PMID: 25606296 MyJurnal
    Rhinoliths result from neglected nasal foreign bodies that gradually increase in size. They are usually discovered incidentally during routine ENT examination or due to the associated symptoms such as nasal obstruction or persistent foul-smelling unilateral nasal discharge. A case of a 14-year-old girl was reported with a year history of the symptom. The foul-smelling nasal discharge noted by her mother was not the main concern to them. She was referred by her primary care physician as she complained of impacted ear wax. However, rhinolith was incidentally found upon routine clinical examination in the ENT clinic and was removed uneventfully.
    Matched MeSH terms: Foreign Bodies
  20. Tang CL, Lee SC, Mohamad Lal A, Thomas RA, Ngui LX, Lim LY
    Med J Malaysia, 2014 Oct;69(5):241-3.
    PMID: 25638243 MyJurnal
    A 6 years old girl accidentally aspirated a plastic whistle while playing. Computed Tomography of thorax showed foreign body at carina level. Rigid bronchoscope under general anesthesia was attempted but unable to extract the whistle through vocal cord. Tracheostomy was later performed and foreign body was removed.
    Matched MeSH terms: Foreign Bodies
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links