Displaying publications 1 - 20 of 52 in total

Abstract:
Sort:
  1. Liu M, Li H, Bai L, Zheng K, Zhao Z, Chen Z, et al.
    J Hazard Mater, 2021 07 05;413:125291.
    PMID: 33588337 DOI: 10.1016/j.jhazmat.2021.125291
    Real-time and visual monitoring of pollutants in the air is of great importance since they are usually cannot be seen, smelled, or touched. Lanthanide nano-cluster is a kind of luminescent sensor for various species. However, controlling synthesis of lanthanide nano-cluster remains experimentally challenging. In this work, four series of lanthanide-barium (Ln-Ba) nano-clusters of Dy2Ba (1), Tb2Ba2 (2), Ln4Ba3 (Ln = Tb, 3a; Eu, 3b), Tb4Ba4 (4) were assembled through precisely controlling the pH of the reactant solutions. The work features the first example that the number of cluster's nuclei changes regularly with the pH. Moreover, investigation reveals that nano-cluster 3a is a highly selective and sensitive sensor towards acetylacetone (acac) and aniline. Interestingly, easy-to-use sensing devices of test paper, agarose gel, and five kinds of film on CaCO3, polyfoam, coin, mask, and wall that based on 3a were fabricated by facile methods. The seven sensing devices showed remarkable ability to sense aniline and acac vapors with visibility to the naked eyes. This is the first work on multiple real-time and visual sensing devices based on the lanthanide nano-cluster.
    Matched MeSH terms: Luminescence
  2. Al-Douri Y, Badi N, Voon CH
    Luminescence, 2018 Mar;33(2):260-266.
    PMID: 29024360 DOI: 10.1002/bio.3408
    Carbon-based quantum dots (C-QDs) were synthesized through microwave-assisted carbonization of an aqueous starch suspension mediated by sulphuric and phosphoric acids. The as-prepared C-QDs showed blue, green and yellow luminescence without the addition of any surface-passivating agent. The C-QDs were further analyzed by UV-vis spectroscopy to measure the optical response of the organic compound. The energy gaps revealed narrow sizing of C-QDs in the semiconductor range. The optical refractive index and dielectric constant were investigated. The C-QDs size distribution was characterized. The results suggested an easy route to the large scale production of C-QDs materials.
    Matched MeSH terms: Luminescence
  3. Norhayati Abdullah, Wong, Jeannie Hsiu Ding, Ng, Kwan Hoong, Ung, Ngie Min
    MyJurnal
    The assessment of surface dose is essential in radiotherapy to avoid deterministic effect or to
    reduce the severity of side effects from radiation treatment. In this study, the surface dose for breast
    cancer radiotherapy was measured using two types of dosimeter; Thermoluminescent Dosimeter
    (TLD) and Optically Stimulated Luminescent Dosimeter (OSLD). The study was performed on the
    left breast of female Alderson Radiation Therapy (ART) phantom. The treatment planning was
    carried out on the ART phantom to determine the homogeneity of dose distribution within the target
    organ is complied with the tolerance limits of 95% to 107% as recommended by the International
    Commission on Radiation Units and Measurements (ICRU)’s Report No. 50. From the treatment
    planning result, the phantom then was irradiated with 267 cGy dose per fraction for two beam
    fields; medial tangential and lateral tangential fields using a 6 MV photon beam produced from
    three-dimensional (3D) conformal radiotherapy. Result shows that the OSLD provides 25.7% and
    23.5% higher surface dose compared to TLD for medial tangential and lateral tangential fields,
    respectively. This condition may be due to higher effective point of measurement and angular
    dependence of the OSLD compared to TLD. As a conclusion, suitable dosimeter should be selected
    to ensure accurate estimation of surface dose could be made thus reduction of skin reaction to
    patient could be achieved.
    Matched MeSH terms: Optically Stimulated Luminescence Dosimetry
  4. Rejab M, Wong JHD, Jamalludin Z, Jong WL, Malik RA, Wan Ishak WZ, et al.
    Australas Phys Eng Sci Med, 2018 Jun;41(2):475-485.
    PMID: 29756166 DOI: 10.1007/s13246-018-0647-6
    This study investigates the characteristics and application of the optically-stimulated luminescence dosimeter (OSLD) in cobalt-60 high dose rate (HDR) brachytherapy, and compares the results with the dosage produced by the treatment planning system (TPS). The OSLD characteristics comprised linearity, reproducibility, angular dependence, depth dependence, signal depletion, bleaching rate and cumulative dose measurement. A phantom verification exercise was also conducted using the Farmer ionisation chamber and in vivo diodes. The OSLD signal indicated a supralinear response (R2 = 0.9998). It exhibited a depth-independent trend after a steep dose gradient region. The signal depletion per readout was negligible (0.02%), with expected deviation for angular dependence due to off-axis sensitive volume, ranging from 1 to 16%. The residual signal of the OSLDs after 1 day bleached was within 1.5%. The accumulated and bleached OSLD signals had a standard deviation of ± 0.78 and ± 0.18 Gy, respectively. The TPS was found to underestimate the measured doses with deviations of 5% in OSLD, 17% in the Farmer ionisation chamber, and 7 and 8% for bladder and rectal diode probes. Discrepancies can be due to the positional uncertainty in the high-dose gradient. This demonstrates a slight displacement of the organ at risk near the steep dose gradient region will result in a large dose uncertainty. This justifies the importance of in vivo measurements in cobalt-60 HDR brachytherapy.
    Matched MeSH terms: Optically Stimulated Luminescence Dosimetry
  5. Hooi Yeen Yap, Jack Bee Chook, Sin Yeang Teow
    MyJurnal
    ntroduction: Nasopharyngeal carcinoma (NPC) is a prevalent cancer among human population in Southern China, Hong Kong and Southeast Asia. In Malaysia, NPC is the fourth most common cancer in both sexes, predominantly in the Chinese. Epstein-Barr virus (EBV) infection is known to be highly associated with NPC. Fibroblast growth factor receptor-4 (FGFR4) is part of the family of tyrosine kinase receptors that regulate cell survival, differentiation and pro-liferation. The binding of FGFR4 ligands such as fibroblasts growth factors (FGFs) has been shown to activate various oncogenic signalling pathway including MAPK, Ras and PI3K-Akt pathways. In the past, FGFR4 has been shown to promote tumorigenesis and tumour progression in various cancers such as liver, colon, breast and pancreatic and gastric cancers. However, its role in NPC establishment and pathogenesis is under-explored. This study aimed to evaluate the FGFR4 expression in NPC using various cell lines and its potential as a therapeutic target for NPC treat-ment by gene silencing. Methods: The basal FGFR4 level of NPC (EBV-positive: C666-1 and EBV-negative: HONE1 and HK1) and nasopharyngeal epithelial (NPE) normal (NP69 and NP460) cell lines was determined by western blot analysis and RT-qPCR. FGFR4 level at different time points (0, 24, 48, and 72 hours) in HONE1 and C666-1 cell lines were determined by western blot analysis. Luminescence-based assay was performed to determine the cell prolifer-ation of NPC cells in correlation with the FGFR4 expression. NPC cells were then treated with the optimised FGFR4 siRNA or FGFR inhibitor, BLU-9931 and the silencing/ inhibition of FGFR4 expression was confirmed by western blot analysis. The effect of FGFR4 inhibition on the cell proliferation and aggressiveness of NPC cells was then investigat-ed through wound healing assay and invasion marker analysis. Results: Out of the five tested cell lines, HONE1 and C666-1 highly expressed FGFR4, NP69 showed very low expression while HK1 and NP460 did not express FGFR4. In the time-point study, the FGFR4 level of HONE1 and C666-1 peaked at 24-48 hours which is the exponential phase of cells. Following that, the FGFR4 level decreased corresponding to the decreased cell growth rate due to the nutrient deprivation. siRNA experiments showed that 6.25nM of four siRNAs (5, 6, 9 and 10) could effectively target and silence the FGFR4 expression of HONE1, but not in C666-1 even up to 250nM was tested. When BLU-9931 was used, only modest inhibition was observed in both cells at 3uM. Compared to the untreated control, FGFR4-inhibited HONE1 exhibited decreased cell proliferation rate. Cell migration and invasion capabilities of HONE1 were also significantly reduced following the FGFR4 silencing, suggesting the potential of utilising FGFR4 as the therapeutic target. Conclusion: FGFR4 is highly expressed in C666-1 (EBV-positive) and HONE1 (initially EBV-positive, but lost EBV genome in subsequent in vitro passage) NPC cells, but not in EBV-negative HK1 NPC cell and normal NPE cells. FGFR4 gene silencing effectively inhibited the cell proliferation, migration and invasive potentials of NPC cell line. These findings highlight the therapeutic value of targeting FGFR4 for NPC treatment. Further investigations are war-ranted to reveal the molecular mechanism and the possible role of EBV in regulating FGFR4 pathway.
    Matched MeSH terms: Luminescence
  6. Junaid M, Md Khir MH, Witjaksono G, Ullah Z, Tansu N, Saheed MSM, et al.
    Molecules, 2020 Sep 14;25(18).
    PMID: 32937975 DOI: 10.3390/molecules25184217
    In recent years, the field of nanophotonics has progressively developed. However, constant demand for the development of new light source still exists at the nanometric scale. Light emissions from graphene-based active materials can provide a leading platform for the development of two dimensional (2-D), flexible, thin, and robust light-emitting sources. The exceptional structure of Dirac's electrons in graphene, massless fermions, and the linear dispersion relationship with ultra-wideband plasmon and tunable surface polarities allows numerous applications in optoelectronics and plasmonics. In this article, we present a comprehensive review of recent developments in graphene-based light-emitting devices. Light emissions from graphene-based devices have been evaluated with different aspects, such as thermal emission, electroluminescence, and plasmons assisted emission. Theoretical investigations, along with experimental demonstration in the development of graphene-based light-emitting devices, have also been reviewed and discussed. Moreover, the graphene-based light-emitting devices are also addressed from the perspective of future applications, such as optical modulators, optical interconnects, and optical sensing. Finally, this review provides a comprehensive discussion on current technological issues and challenges related to the potential applications of emerging graphene-based light-emitting devices.
    Matched MeSH terms: Luminescence
  7. Ram S, Siar CH
    Int J Oral Maxillofac Surg, 2005 Jul;34(5):521-7.
    PMID: 16053872
    Chemiluminescence was evaluated as a diagnostic aid in the detection of oral cancer and potentially malignant epithelial lesions (PMELs) by comparing it against 1% tolonium chloride mouth rinse. Forty-six clinically identified lesions [14 primary squamous cell carcinoma (SCC), 26 PMELs and 6 benign lesions] and five cases of normal oral mucosa from 40 subjects (inclusive of 10 previously treated SCC cases) were examined with a commercial chemiluminescent kit (Vizilite) and tolonium chloride. Biopsy and histological verification of 31 lesions disclosed 14 SCC (45.2%), 10 epithelial dysplasias (32.3%), 5 lichen planus (16.1%) and 2 benign lesions (6.4%). For the remaining 15 lesions, a biopsy was not performed owing to patient's lack of consent or ill-health. The five cases of normal oral mucosa which tested negative for both tools were also not biopsied for ethical reasons. Sensitivity for Vizilite and tolonium chloride was 100% and 70.3%, respectively; and specificity was 14.2% for Vizilite and 25% for tolonium chloride. Their accuracy was 80.6% and 64.5%, respectively. Current findings suggest that chemiluminescence is a more reliable diagnostic tool than tolonium chloride in the detection of oral cancer and PMELs, and for follow-up of patients treated for the same.
    Matched MeSH terms: Luminescence*
  8. Bradley DA, Nawi SNM, Khandaker MU, Almugren KS, Sani SFA
    Appl Radiat Isot, 2020 Jul;161:109168.
    PMID: 32321700 DOI: 10.1016/j.apradiso.2020.109168
    Present work concerns polymer pencil-lead graphite (PPLG) and the potential use of these in elucidating irradiation-driven structural alterations. The study provides detailed analysis of radiation-induced structural interaction changes and the associated luminescence that originates from the energy absorption. Thermally stimulated emission from the different occupied defect energy levels reflects the received radiation dose, different for the different diameter PPLGs. The PPLG samples have been exposed to photon irradiation, specifically x-ray doses ranging from 1 to 10 Gy, extended to 30-200 Gy through use of a60Co gamma-ray source. Trapping parameters such as order of kinetics, activation energy and frequency factor are estimated using Chen's peak-shape method for a fixed-dose of 30 Gy. X-ray diffractometry was used to characterize the crystal structure of the PPLG, the aim being to identify the degree of structural order, atomic spacing and lattice constants of the various irradiated PPLG samples. The mean atomic spacing and degree of structural order for the different diameter PPLG are found to be 0.3332 nm and 26.6° respectively. Photoluminescence spectra from PPLG arising from diode laser excitation at 532 nm consist of two adjacent peaks, 602 nm (absorption) and 1074 nm (emission), with mean energy band gap values within the range 1.113-1.133 eV.
    Matched MeSH terms: Luminescence
  9. Moi IM, Roslan NN, Leow ATC, Ali MSM, Rahman RNZRA, Rahimpour A, et al.
    Appl Microbiol Biotechnol, 2017 Jun;101(11):4371-4385.
    PMID: 28497204 DOI: 10.1007/s00253-017-8300-y
    Photobacterium species are Gram-negative coccobacilli which are distributed in marine habitats worldwide. Some species are unique because of their capability to produce luminescence. Taxonomically, about 23 species and 2 subspecies are validated to date. Genomes from a few Photobacterium spp. have been sequenced and studied. They are considered a special group of bacteria because some species are capable of producing essential polyunsaturated fatty acids, antibacterial compounds, lipases, esterases and asparaginases. They are also used as biosensors in food and environmental monitoring and detectors of drown victim, as well as an important symbiont.
    Matched MeSH terms: Luminescence
  10. Leong PM, Eeu TY, Leow TQ, Pang XG, Zuhairi Ibrahim, Rosli Hussin
    Sains Malaysiana, 2014;43:915-922.
    Structural and luminescence properties of borophosphate glasses with different modifier doped with transition metal ions have been investigated in this study. The glass sample from the series of xPb 30 4:0 .2Sb20 3:0.3B 20 3:(0 .5-x)P 20 5 and ySb 20 3:0 .2Pb 30 4:(0 .5-y)B 20 3:0 .3P 20 5where x 20 mol% and 0 y 0 .1 5mol% , respectively, were doped with 0.01 mol% of Fe 20 3 system have been prepared using the melt-quenching technique. The structural properties of samples had been studied using fourier transform infrared (FT-m) spectroscopy. The FT-IR study showed the network structure of the studied glasses based on the B 20 3-P 20 5host with the 5b203 and Pb203 modifiers. The results of FT-IR showed traces of B03 and B04 with the introduction of 5b203 and Pb203 modifiers. With the increasing content of B203 which replacing content of P205 in the glass network, the intensity of the borate band decreases and shifted to lower frequency. uv-Vis spectroscopy analysed the transition of Fe3+ from ground state to excited state in the ultraviolet spectral region. The photoluminescence of samples were studied using photoluminescence spectroscopy. The result of photoluminescence spectroscopy showed the effect of photoluminescence enhancement by doping Fe3+ as activator.
    Matched MeSH terms: Luminescence
  11. Xu Q, Li W, Ding L, Yang W, Xiao H, Ong WJ
    Nanoscale, 2019 Jan 23;11(4):1475-1504.
    PMID: 30620019 DOI: 10.1039/c8nr08738e
    Metal-free carbonaceous nanomaterials have witnessed a renaissance of interest due to the surge in the realm of nanotechnology. Among myriads of carbon-based nanostructures with versatile dimensionality, one-dimensional (1D) carbon nanotubes (CNTs) and zero-dimensional (0D) carbon dots (CDs) have grown into a research frontier in the past few decades. With extraordinary mechanical, thermal, electrical and optical properties, CNTs are utilized in transparent displays, quantum wires, field emission transistors, aerospace materials, etc. Although CNTs possess diverse characteristics, their most attractive property is their unique photoluminescence. On the other hand, another growing family of carbonaceous nanomaterials, which is CDs, has drawn much research attention due to its cost-effectiveness, low toxicity, environmental friendliness, fluorescence, luminescence and simplicity to be synthesized and functionalized with surface passivation. Benefiting from these unprecedented properties, CDs have been widely employed in biosensing, bioimaging, nanomedicine, and catalysis. Herein, we have systematically presented the fascinating properties, preparation methods and multitudinous applications of CNTs and CDs (including graphene quantum dots). We will discuss how CNTs and CDs have emerged as auspicious nanomaterials for potential applications, especially in electronics, sensors, bioimaging, wearable devices, batteries, supercapacitors, catalysis and light-emitting diodes (LEDs). Last but not least, this review is concluded with a summary, outlook and invigorating perspectives for future research horizons in this emerging platform of carbonaceous nanomaterials.
    Matched MeSH terms: Luminescence
  12. Noah, R.M., Yusuff, Z., Jais, M.R., Noh, L.M.
    MyJurnal
    Chemiluminescence assay was used to assess the respiratory burst activities of polymorpho-nuclear leukocytes from paediatric patients reported to manifest with several episodes of recurrent bacterial infections. From this group of patients evaluated, only 10 cases of severe recurrent bacterial abscess exhibited more than 80% depression in the phagocytic chemilumi-nescence responses. The assay, being a sensitive method, was able to provide further useful laboratory investigation in diagnosing 4 patients with chronic granulomatous disease.
    Matched MeSH terms: Luminescence
  13. Loi E, Ng RW, Chang MM, Fong JF, Ng YH, Ng SM
    Luminescence, 2017 Feb;32(1):114-118.
    PMID: 27166514 DOI: 10.1002/bio.3157
    Carbon dots, a new class of nanomaterial with unique optical property and have great potential in various applications. This work demonstrated the possibility of tuning the emission wavelength of carbon dots by simply changing the acid type used during synthesis. In particular, sulfuric and phosphoric acids and a mixture of the two were used to carbonize the same starting precursor, sucrose. This resulted in the isolation of carbon dots with blue (440 nm) and green (515 nm) emission. Interestingly, the use of an acid mixture at various ratios did not shift the initial emission profile, but did obviously alter the fluorescence efficiency of the peaks. This clearly showed that acid type can be used as an alternative tool to produce carbon dots that have different emissions using the same starting precursor. Copyright © 2016 John Wiley & Sons, Ltd.
    Matched MeSH terms: Luminescence*
  14. Yusof FH, Ung NM, Wong JH, Jong WL, Ath V, Phua VC, et al.
    PLoS One, 2015;10(6):e0128544.
    PMID: 26052690 DOI: 10.1371/journal.pone.0128544
    This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface doses were measured on a solid water phantom using the OSLD and compared against the Markus ionization chamber and Gafchromic EBT3 film measurements. The effect of incident beam angles on surface dose was also studied. The OSLD was subsequently used to measure surface dose during tangential breast radiotherapy treatments in a phantom study and in the clinical measurement of 10 patients. Surface dose to the treated breast or chest wall, and on the contralateral breast were measured. The WED of the OSLD was found to be at 0.4 mm. For surface dose measurement on a solid water phantom, the Markus ionization chamber measured 15.95% for 6 MV photon beam and 12.64% for 10 MV photon beam followed by EBT3 film (23.79% and 17.14%) and OSLD (37.77% and 25.38%). Surface dose increased with the increase of the incident beam angle. For phantom and patient breast surface dose measurement, the response of the OSLD was higher than EBT3 film. The in-vivo measurements were also compared with the treatment planning system predicted dose. The OSLD measured higher dose values compared to dose at the surface (Hp(0.0)) by a factor of 2.37 for 6 MV and 2.01 for 10 MV photon beams, respectively. The measurement of absorbed dose at the skin depth of 0.4 mm by the OSLD can still be a useful tool to assess radiation effects on the skin dermis layer. This knowledge can be used to prevent and manage potential acute skin reaction and late skin toxicity from radiotherapy treatments.
    Matched MeSH terms: Luminescence*
  15. Wong JHD, Bakhsh M, Cheah YY, Jong WL, Khor JS, Ng KH
    Radiat Prot Dosimetry, 2019 Dec 31;187(4):451-460.
    PMID: 31650160 DOI: 10.1093/rpd/ncz186
    This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.
    Matched MeSH terms: Optically Stimulated Luminescence Dosimetry/instrumentation*; Optically Stimulated Luminescence Dosimetry/methods*
  16. Lokman Mohd Noh, Zulkifli Ismail, Farida Jamal, Rahim Md Noah, Sabiha Pit, Hina Isahak, et al.
    MyJurnal
    Recurrent boils are troublesome enough to children and their parents to be finally referred to the paediatricians. This study attempts to provide local data on epidemiology, pattern of infections of offending organism especially Staphylococcus aureus and underlying immunological abnormality. This condition does not appear to be related to socio economic status nor is staphylococcal nasal cariage a direct contributing factor. Defect in neutrophil function especially the respiratory burst assayed via chemiluminescence response to Staphylococcus aureus is closely associated with this condition. It is hoped that this data would be a further impetus for further research into this exciting field.
    Matched MeSH terms: Luminescence
  17. Desjardin DE, Perry BA, Lodge DJ, Stevani CV, Nagasawa E
    Mycologia, 2010 4 7;102(2):459-77.
    PMID: 20361513
    Seven species of Mycena are reported as luminescent, representing specimens collected in Belize, Brazil, Dominican Republic, Jamaica, Japan (Bonin Islands), Malaysia (Borneo) and Puerto Rico. Four of them represent new species (Mycena luxaeterna, M. luxarboricola, M. luxperpetua, M. silvaelucens) and three represent new reports of luminescence in previously described species (M. aff. abieticola, M. aspratilis, M. margarita). Mycena subepipterygia is synonymized with M. margarita, and M. chlorinosma is proposed as a possible synonym. Comprehensive descriptions, illustrations, photographs and comparisons with phenetically similar species are provided. A redescription of M. chlorophos, based on analyses of type specimens and recently collected topotypical material, is provided. The addition of these seven new or newly reported luminescent species of Mycena brings the total to 71 known bioluminescent species of fungi.
    Matched MeSH terms: Luminescence
  18. Nurul Huda Yusoff, Muhamad Mat Salleh, Muhammad Yahaya
    Sains Malaysiana, 2008;37:233-237.
    This research explores the possibility of using fluorescence technique to detect the presence of volatile organic compounds based on a single sensing material. The material used was TiO2 nanoparticles coated with porphyrin dye. The TiO2 nanoparticles colloid is in a sol-gel form synthesized from titanium (IV) ethoxide in ethanol with addition of kalium chloride (KCl) as stabilizer. TiO2 nanoparticles were then coated with porphyrin dye, Manganase (III) 5,10,15,20 tetra (4-pyridyl)-21H, 23H porphine chloride tetrakis (metachloride). The coated nanoparticles were deposited on quartz substrate using self-assembly through dip coating technique. The sensing properties of the thin film toward volatile organic compounds; ethanol, acetone, cyclohexane and 2-propanol were studied using luminescence spectrometer. It was found that the thin film produced different emission spectra peaks for different volatile organic compounds (VOCs). Hence, it eases chemical identification process and potentially be use as fluorescence gas sensor.
    Matched MeSH terms: Luminescence
  19. Ros Anita Ahmad Ramli, Ahmad Zainuri Mohd Dzomir, Zainon Othman, Wan Saffiey Wan Abdullah, Muhamad Samudi Yasir
    MyJurnal
    The exposure of food to ionizing radiation is being progressively used in many countries to
    inactivate food pathogens, to eradicate pests and to extend shelf-life of food. To ensure free
    consumer choice, irradiated food will be labeled. The availability of a reliable method to detect
    irradiated food is important to enforce legal controls on labeling requirements, ensure proper
    distribution and increase consumer confidence. This paper reports on the preliminary application
    of photostimulated luminescence technique (PSL) as a potential method to detect irradiated food
    and perhaps be used for monitoring irradiated food on sale locally in the near future. Thus this
    study will be beneficial and relevant for application of food irradiation towards improving food
    safety and security in Malaysia.
    Matched MeSH terms: Luminescence
  20. Siti Farhana Zakaria, Millington, Keith R.
    MyJurnal
    Polymers and organic materials that are exposed to sunlight undergo photooxidation, which leads to deterioration of their physical properties. To allow adequate performance under outdoor conditions, synthetic polymers require additives such as antioxidants and UV absorbers. A major problem with optimising polymer formulations to maximise their working life span is that accelerated weathering tests are empirical. The conditions differ significantly from real weathering situations, and samples require lengthy irradiation period. Degradation may not be apparent in the early stages of exposure, although this is when products such as hydroperoxides are formed which later cause acceleration of oxidation. A simple way of quantifying the number of free radicals presents in organic materials following exposure to light or heat is by measuring chemiluminescence (CL) emission. Most polymers emit CL when they undergo oxidative degradation, and it originates from the bimolecular reaction of macroperoxy radicals which creates an excited carbonyl.
    Matched MeSH terms: Luminescence
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links