Displaying publications 1 - 20 of 82 in total

Abstract:
Sort:
  1. Zalma AR, Safiah MY, Ajau D, Khairil Anuar MI
    Health Promot Int, 2015 Sep;30(3):523-30.
    PMID: 24150531 DOI: 10.1093/heapro/dat072
    Interventions to counter the influence of television food advertising amongst children are important. Thus, reliable and valid instrument to assess its effect is needed. The objective of this study was to determine the reliability and validity of such a questionnaire. The questionnaire was administered twice on 32 primary schoolchildren aged 10-11 years in Selangor, Malaysia. The interval between the first and second administration was 2 weeks. Test-retest method was used to examine the reliability of the questionnaire. Intra-rater reliability was determined by kappa coefficient and internal consistency by Cronbach's alpha coefficient. Construct validity was evaluated using factor analysis. The test-retest correlation showed moderate-to-high reliability for all scores (r = 0.40*, p = 0.02 to r = 0.95**, p = 0.00), with one exception, consumption of fast foods (r = 0.24, p = 0.20). Kappa coefficient showed acceptable-to-strong intra-rater reliability (K = 0.40-0.92), except for two items under knowledge on television food advertising (K = 0.26 and K = 0.21) and one item under preference for healthier foods (K = 0.33). Cronbach's alpha coefficient indicated acceptable internal consistency for all scores (0.45-0.60). After deleting two items under Consumption of Commonly Advertised Food, the items showed moderate-to-high loading (0.52, 0.84, 0.42 and 0.42) with the Scree plot showing that there was only one factor. The Kaiser-Meyer-Olkin was 0.60, showing that the sample was adequate for factor analysis. The questionnaire on television food advertising is reliable and valid to assess the effect of media literacy education on television food advertising on schoolchildren.
    Matched MeSH terms: Observer Variation
  2. Zabidin N, Mohamed AM, Zaharim A, Marizan Nor M, Rosli TI
    Int Orthod, 2018 03;16(1):133-143.
    PMID: 29478934 DOI: 10.1016/j.ortho.2018.01.009
    OBJECTIVES: To evaluate the relationship between human evaluation of the dental-arch form, to complete a mathematical analysis via two different methods in quantifying the arch form, and to establish agreement with the fourth-order polynomial equation.

    MATERIALS AND METHODS: This study included 64 sets of digitised maxilla and mandible dental casts obtained from a sample of dental arch with normal occlusion. For human evaluation, a convenient sample of orthodontic practitioners ranked the photo images of dental cast from the most tapered to the less tapered (square). In the mathematical analysis, dental arches were interpolated using the fourth-order polynomial equation with millimetric acetate paper and AutoCAD software. Finally, the relations between human evaluation and mathematical objective analyses were evaluated.

    RESULTS: Human evaluations were found to be generally in agreement, but only at the extremes of tapered and square arch forms; this indicated general human error and observer bias. The two methods used to plot the arch form were comparable.

    CONCLUSION: The use of fourth-order polynomial equation may be facilitative in obtaining a smooth curve, which can produce a template for individual arch that represents all potential tooth positions for the dental arch.

    Matched MeSH terms: Observer Variation
  3. Yusoff MS
    Med Educ, 2012 Nov;46(11):1122.
    PMID: 23078712 DOI: 10.1111/medu.12057
    Matched MeSH terms: Observer Variation*
  4. Yusof MYPM, Rahman NLA, Asri AAA, Othman NI, Wan Mokhtar I
    Imaging Sci Dent, 2017 Dec;47(4):233-239.
    PMID: 29279822 DOI: 10.5624/isd.2017.47.4.233
    Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor.

    Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis.

    Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved.

    Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.

    Matched MeSH terms: Observer Variation
  5. Yoshida N, Naito Y, Yasuda R, Murakami T, Hirose R, Ogiso K, et al.
    Int J Colorectal Dis, 2017 Sep;32(9):1253-1260.
    PMID: 28725959 DOI: 10.1007/s00384-017-2855-z
    PURPOSE: Linked color imaging (LCI) by laser endoscopy is a novel narrow band light observation. In this study, we analyzed the efficacy of LCI for improving the various featured colorectal polyp's visibility utilizing a subjective endoscopist's visibility scoring and objective color difference (CD) value.

    METHODS: We retrospectively reviewed two pictures both with white light (WL) and LCI for 54 consecutive neoplastic polyps 2-20 mm in size. All pictures were evaluated by four endoscopists according to a published polyp visibility score from four (excellent visibility) to one (poor visibility). Additionally, we calculated CD value between each polyp and surrounding mucosa in LCI and WL using an original software.

    RESULTS: The mean polyp visibility scores of LCI (3.11 ± 1.05) were significantly higher than those of WL (2.50 ± 1.09, P 

    Matched MeSH terms: Observer Variation
  6. Yap KL, Lam SK
    J Virol Methods, 1994 Apr;47(1-2):217-26.
    PMID: 8051228
    A simple, rapid and objective infectivity assay based on an in situ enzyme immunoassay (EIA) was developed for the fast-growing and cytopathic cell culture-adapted hepatitis A virus (HAV) strain HM175A.2. Infectivity titration by EIA correlated well with titration by cytopathic effects. The reliability of this assay was demonstrated by close agreement in virus infectivity titers among different assays of the same virus aliquot and between assays of different virus aliquots. HAV infected cell cultures after fixation could be stored for up to 1 week before testing without decline in virus titer.
    Matched MeSH terms: Observer Variation
  7. Yap CK, Ismail A, Tan SG
    Environ Int, 2003 Jul;29(4):521-8.
    PMID: 12705949
    Concentrations of cadmium (Cd), lead (Pb) and zinc (Zn) in total soft tissues (ST) and byssus (BYS) of the green-lipped mussel Perna viridis from 11 different geographical locations off the west coast of Peninsular Malaysia were determined. The metal concentrations distributed between the BYS and ST were compared. The results of this study indicated that higher levels of Cd (1.31 microg/g), Pb (38.49 microg/g) and Zn (206.52 microg/g) were accumulated in the BYS than in the total ST (Cd: 0.29 microg/g; Pb: 8.27 microg/g; Zn: 102.6 microg/g). Semi-static and short period controlled laboratory experiments were also conducted for the accumulation and depuration of Cd, Pb and Zn in the total ST and BYS of P. viridis. The ratios (BYS/ST) for Pb and Cd from the laboratory experiments showed that the total ST accumulated more metals than the BYS. Therefore, these laboratory results disagreed with those found for the field samples. However, the laboratory results for the Zn ratio (BYS/ST) agreed with those of the field samples. It was evident that when compared to the ST, the BYS was a more sensitive biomonitoring organ for Zn while it could be a complementary organ for Cd and Pb in the total ST. Since total ST of P. viridis had been reported to have regulative mechanism for Zn, its BYS can be used as a biomonitoring organ for the identification of coastal areas exposed to Zn pollution.
    Matched MeSH terms: Observer Variation
  8. Weiss SL, Fitzgerald JC, Maffei FA, Kane JM, Rodriguez-Nunez A, Hsing DD, et al.
    Crit Care, 2015;19:325.
    PMID: 26373923 DOI: 10.1186/s13054-015-1055-x
    Consensus criteria for pediatric severe sepsis have standardized enrollment for research studies. However, the extent to which critically ill children identified by consensus criteria reflect physician diagnosis of severe sepsis, which underlies external validity for pediatric sepsis research, is not known. We sought to determine the agreement between physician diagnosis and consensus criteria to identify pediatric patients with severe sepsis across a network of international pediatric intensive care units (PICUs).
    Matched MeSH terms: Observer Variation
  9. Wee LK, Chai HY, Samsury SR, Mujamil NF, Supriyanto E
    An Acad Bras Cienc, 2012 Dec;84(4):1157-68.
    PMID: 23207710
    Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.
    Matched MeSH terms: Observer Variation
  10. Toh TH, Lim BC, Bujang MAB, Haniff J, Wong SC, Abdullah MR
    Pediatr Int, 2017 Aug;59(8):861-868.
    PMID: 28510345 DOI: 10.1111/ped.13325
    BACKGROUND: We examined the parental perception and accuracy of the Mandarin translation of the Parents' Evaluation of Developmental Status, a screening questionnaire for parent concerns about children's various developmental skills.

    METHODS: The questionnaire was translated into Mandarin. Upon enrollment, caregivers completed the Mandarin PEDS and answered four questions about its acceptability and usefulness, and its ease of understanding and completion. The Mandarin PEDS was independently evaluated by a pediatrician and a community nurse, and classified as high risk (≥two predictive concerns), medium risk (one predictive concern), low risk (any non-predictive concerns) or no risk (if no concern) for developmental delays. The caregivers repeated Mandarin PEDS at a 2 week interval for test-retest reliability, while the children underwent testing for accuracy using a developmental assessment test.

    RESULTS: The majority (≥85%) of the 73 caregivers perceived the Mandarin PEDS as acceptable and useful, as well as easy to understand and complete. Fifteen (20.5%) and 24 responses (33.9%) were classified as high and moderate risk, respectively. The test-retest and inter-rater reliabilities were excellent, with an intra-class correlation coefficient of 0.812 (95% CI: 0.701-0.881, P 

    Matched MeSH terms: Observer Variation
  11. Thomas LA, Thomas LR, Balla SB, Gopalaiah H, Kanaparthi A, Sai Sravanthi G, et al.
    Leg Med (Tokyo), 2021 Feb;48:101814.
    PMID: 33246253 DOI: 10.1016/j.legalmed.2020.101814
    In the context of dental age assessment, two significant factors can be studied; tooth mineralisation and tooth emergence. Little is known about the role of a second molar eruption in forensic age estimation. This paper aims to contribute to forensic age estimation using an age threshold of 14 years, studying the eruption stages of permanent mandibular premolars and second molars. Totally 640 orthopantomograms (OPGs) of south Indian children, aged between 10 and 18 years, were evaluated using Olze et al. staging of tooth eruption stages (A-D). Spearman's rho correlation showed a strong, positive, and statistically significant correlation between the chronological age and the eruption stages of both sexes' teeth. Accuracy, sensitivity, specificity, likelihood ratios, and post-test probability values were calculated for all tested teeth. The best performance to discriminate individuals above or below 14 years showed stage D in second molars. The sensitivity varied between 89% and 94% and specificity between 75% and 84%, respectively. Receiver operating characteristic curve analysis revealed high diagnostic performance for stage D, with area under the ROC curve (AUC) values of 84% and 85% for tooth 37 and 85% and 83% for tooth 47 in males and females, respectively. In conclusion, it is possible to predict age over 14 years in south Indian children using tooth emergence stages from OPGs with a relatively high interobserver agreement and good diagnostic accuracy. However, there are some limitations and, therefore, must be used in conjunction with other methods.
    Matched MeSH terms: Observer Variation
  12. Shoaib L, Deery C, Ricketts DN, Nugent ZJ
    Caries Res, 2009;43(6):442-8.
    PMID: 19907175 DOI: 10.1159/000258551
    The aim of this in vitro study was to assess the validity and reproducibility of the ICDAS II (International Caries Detection and Assessment System) criteria in primary teeth. Three trained examiners independently examined 112 extracted primary molars, ranging from clinically sound to cavitated, set up in groups of 4 to mimic their anatomical positions. The most advanced caries on the occlusal and approximal surfaces was recorded. Subsequently the teeth were serially sectioned and histological validation was undertaken using the Downer and Ekstrand-Ricketts-Kidd (ERK) scoring systems. For occlusal surfaces at the D(1)/ERK(1) threshold, the mean specificity was 90.0%, with a sensitivity of 75.4%. For approximal surfaces, the specificity and sensitivity were 85.4 and 66.4%, respectively. For occlusal surfaces at ICDAS code > or =3 (ERK(3) threshold), the mean specificity and sensitivity were 87.0 and 78.1%, respectively. For approximal surfaces, the equivalent values were 90.6 and 75.3%. At the D(3) threshold for occlusal surfaces, the mean specificity and sensitivity were 92.8 and 63.1%, and for approximal surfaces 94.2 and 58.3%, respectively. Mean intraexaminer reproducibility (Cohen's kappa) ranged from 0.78 to 0.81 at the ICDAS code > or =1 cut-off and at the ICDAS code > or =3 cut-off from 0.74 to 0.76. Interexaminer reproducibility was lower, ranging from 0.68 to 0.70 at the ICDAS code > or =1 cut-off and from 0.66 to 0.73 at the ICDAS code > or =3 cut-off. In conclusion, the validity and reproducibility of the ICDAS II criteria were acceptable when applied to primary molar teeth.
    Matched MeSH terms: Observer Variation
  13. Shahar S, Pooy NS
    Asia Pac J Clin Nutr, 2003;12(1):80-4.
    PMID: 12737015
    Height is an important clinical indicator to derive body mass index (BMI), creatinine height index and also to estimate basal energy expenditure, basal metabolic rate and vital capacity through lung function. However, height measurement in the elderly may impose some difficulties and the reliability is doubtful. Equations estimating height from other anthropometric measures have been developed for Caucasians, but only one study has developed an equation (based on arm span only) for an Asian population. Therefore, a cross sectional study was conducted to develop equations using several anthropometric measurements for estimating stature in Malaysian elderly. A total of 100 adults (aged 30 to 49 y) and 100 elderly subjects (aged 60 to 86 y) from three major ethnic groups of Malays (52%), Chinese (38.5%) and Indians (9.5%) participated in this study. Anthropometric measurements included body weight, height, arm span, half arm span, demi span and knee height were carried out by trained nutritionists. Inter and intra observer errors and also % Coefficient Variation (%CV) were calculated for each anthropometric measurement. Equations to estimate stature were developed from the anthropometric measurements of arm span, demi span and knee height of adults using linear regression analysis according to sex. Elderly subjects were shorter and lighter compared to their younger counterparts. The %CV of anthropometric measurements in adults and elderly subjects ranged between 5 to 6%, with standing height having the lowest %CV. When the equations derived from adults were applied to elderly subjects, it was found that percentage difference between actual height and the estimated value ranged from 1.0 to 3.3%. However, the percentage difference between estimated height from the equations developed in this study compared to those derived from the equations of other populations ranged between 0.2 to 8.7%. In conclusion, standing height is an ideal technique for estimating the stature of individuals. However, in cases where its measurement is not possible or reliable, such as in elderly subjects, height can be estimated from proxy indicators of stature. In this study arm span showed the highest correlation with standing height, which is in agreement with other studies. It should be borne in mind that equations derived from taller statured populations (e.g. Caucasians) may be less accurate when applied to shorter statured populations.
    Matched MeSH terms: Observer Variation
  14. Sarmadi S, Izadi-Mood N, Sanii S, Motevalli D
    Malays J Pathol, 2019 Apr;41(1):15-24.
    PMID: 31025633
    INTRODUCTION: In the event of encountering hydropic villi in products of conception specimens, pathologists will have to distinguish complete and partial hydatidiform mole (CHM & PHM) from hydropic abortion (HA). The histological diagnostic criteria are subjective and demonstrate considerable inter-observer variability.

    MATERIALS AND METHODS: This study evaluated the inter-observer variability in diagnosis of CHM, PHM and HA according to defined histologic criteria. Ninety abortus conception specimens were reviewed. Representative haematoxylin and eosin-stained slides were assigned independently to two pathologists who were asked to make a diagnosis of CHM, PHM or HA, and provide a report of the identified diagnostic histological criteria. Kappa value was calculated for the inter-observer agreement.

    RESULTS: There was a total of 36.7% disagreement between two pathologists (K = 0.403, Strength of Agreement = moderate), of which 24.4% and 12.2%, were differentiating PHM from CHM and PHM from HA, respectively. Among defined diagnostic histological criteria, the highest rate of agreement was observed in the identification of cistern formation and hydropic changes (K = 0.746 and 0.686 respectively, Strength of Agreement = substantial).

    CONCLUSION: There was moderate to substantial agreement rate between two pathologists in identification of two essential histologic criteria for diagnosis of molar pregnancies i.e. "hydropic change" and "trophoblastic proliferation".

    Matched MeSH terms: Observer Variation
  15. Sahathevan S, Khor BH, Yeong CH, Tan TH, Meera Mohaideen AK, Ng HM, et al.
    JPEN J Parenter Enteral Nutr, 2021 07;45(5):872-873.
    PMID: 34165200 DOI: 10.1002/jpen.2206
    Matched MeSH terms: Observer Variation
  16. Saba L, Than JC, Noor NM, Rijal OM, Kassim RM, Yunus A, et al.
    J Med Syst, 2016 Jun;40(6):142.
    PMID: 27114353 DOI: 10.1007/s10916-016-0504-7
    Human interaction has become almost mandatory for an automated medical system wishing to be accepted by clinical regulatory agencies such as Food and Drug Administration. Since this interaction causes variability in the gathered data, the inter-observer and intra-observer variability must be analyzed in order to validate the accuracy of the system. This study focuses on the variability from different observers that interact with an automated lung delineation system that relies on human interaction in the form of delineation of the lung borders. The database consists of High Resolution Computed Tomography (HRCT): 15 normal and 81 diseased patients' images taken retrospectively at five levels per patient. Three observers manually delineated the lungs borders independently and using software called ImgTracer™ (AtheroPoint™, Roseville, CA, USA) to delineate the lung boundaries in all five levels of 3-D lung volume. The three observers consisted of Observer-1: lesser experienced novice tracer who is a resident in radiology under the guidance of radiologist, whereas Observer-2 and Observer-3 are lung image scientists trained by lung radiologist and biomedical imaging scientist and experts. The inter-observer variability can be shown by comparing each observer's tracings to the automated delineation and also by comparing each manual tracing of the observers with one another. The normality of the tracings was tested using D'Agostino-Pearson test and all observers tracings showed a normal P-value higher than 0.05. The analysis of variance (ANOVA) test between three observers and automated showed a P-value higher than 0.89 and 0.81 for the right lung (RL) and left lung (LL), respectively. The performance of the automated system was evaluated using Dice Similarity Coefficient (DSC), Jaccard Index (JI) and Hausdorff (HD) Distance measures. Although, Observer-1 has lesser experience compared to Obsever-2 and Obsever-3, the Observer Deterioration Factor (ODF) shows that Observer-1 has less than 10% difference compared to the other two, which is under acceptable range as per our analysis. To compare between observers, this study used regression plots, Bland-Altman plots, two tailed T-test, Mann-Whiney, Chi-Squared tests which showed the following P-values for RL and LL: (i) Observer-1 and Observer-3 were: 0.55, 0.48, 0.29 for RL and 0.55, 0.59, 0.29 for LL; (ii) Observer-1 and Observer-2 were: 0.57, 0.50, 0.29 for RL and 0.54, 0.59, 0.29 for LL; (iii) Observer-2 and Observer-3 were: 0.98, 0.99, 0.29 for RL and 0.99, 0.99, 0.29 for LL. Further, CC and R-squared coefficients were computed between observers which came out to be 0.9 for RL and LL. All three observers however manage to show the feature that diseased lungs are smaller than normal lungs in terms of area.
    Matched MeSH terms: Observer Variation*
  17. Rusmah M
    Odontostomatol Trop, 1992 Mar;15(1):13-5.
    PMID: 1287605
    The maxillary casts of 320 Malaysian children were examined for the occurrence of the Carabelli trait on the maxillary first permanent molars. The total trait frequency was observed to be 52.2 per cent. Statistical analysis showed no sex dimorphism in the occurrence of the trait. Bilateral occurrence with a tendency towards concordance of expression between sides was also observed.
    Matched MeSH terms: Observer Variation
  18. Romli MH, Mackenzie L, Lovarini M, Tan MP, Clemson L
    J Eval Clin Pract, 2017 Jun;23(3):662-669.
    PMID: 28105771 DOI: 10.1111/jep.12697
    RATIONALE, AIMS AND OBJECTIVES: Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context.

    METHODS: A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur.

    RESULTS: Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters.

    CONCLUSION: The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls.

    Matched MeSH terms: Observer Variation
  19. Rey JM, Peng R, Morales-Blanquez C, Widyawati I, Peralta V, Walter G
    J Am Acad Child Adolesc Psychiatry, 2000 Sep;39(9):1168-74.
    PMID: 10986814 DOI: 10.1097/00004583-200009000-00017
    OBJECTIVE:
    To examine the extent to which clinicians from different cultures agree when rating the quality of a child's family environment and the effect of country, language, and training factors on these ratings.

    METHOD:
    Eighty-seven health professionals from Malaysia, Spain, Australia, Indonesia, the United States, Denmark, and Singapore rated 7 case vignettes using the Global Family Environment Scale. Half (54%) were psychiatrists. One quarter (26%) performed the ratings after attending a training session, the rest (n = 64, 74%) after reading a training manual.

    RESULTS:
    Overall, interrater agreement (intraclass r) was 0.84 (95% confidence interval: 0.68-0.96). There were no significant differences in agreement according to country, language, training, or professional group, although there were country differences in the ratings given to 2 vignettes. The majority of raters found the description of the anchor points (86%), training manual (95%), and case vignettes (97%) clear.

    CONCLUSIONS:
    Clinicians from different cultures seem to be able to make global ratings of the quality of the family environment that are reliable and consistent when using case vignettes. This can be achieved with little training. Global ratings of the quality of the family environment may be a useful tool in mental health research and clinical work.
    Matched MeSH terms: Observer Variation
  20. Ramli NM, Sidek S, Rahman FA, Peyman M, Zahari M, Rahmat K, et al.
    Graefes Arch Clin Exp Ophthalmol, 2014 Jun;252(6):995-1000.
    PMID: 24770532 DOI: 10.1007/s00417-014-2622-6
    PURPOSE: To measure optic nerve (ON) volume using 3 T magnetic resonance imaging (MRI), to correlate ON volume with retinal nerve fiber layer (RNFL) thickness, and to determine the viability of MRI as an objective tool in distinguishing glaucoma severity.

    METHODS: In this cross-sectional study, 30 severe glaucoma patients, 30 mild glaucoma patients and 30 age-matched controls were recruited. All subjects underwent standard automated perimetry, RNFL analysis and 3 T MRI examinations. Glaucoma patients were classified according to the Hodapp-Anderson-Parish classification. Pearson's correlation coefficient was used to correlate ON volume with RNFL, and receiver operating curve (ROC) analysis was performed to determine the sensitivity and specificity of ON volume in detecting glaucoma severity.

    RESULTS: Optic nerve volume was significantly lower in both the left and right eyes of the severe glaucoma group (168.70 ± 46.28 mm(3); 167.40 ± 45.36 mm(3)) than in the mild glaucoma group (264.03 ± 78.53 mm(3); 264.76 ± 78.88 mm(3)) and the control group (297.80 ± 71.45 mm(3); 296.56 ± 71.02 mm(3)). Moderate correlation was observed between: RNFL thickness and ON volume (r = 0.51, p <0.001), and in mean deviation of visual field and optic nerve volume (r = 0.60, p 

    Matched MeSH terms: Observer Variation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links