Displaying publications 1 - 20 of 69 in total

Abstract:
Sort:
  1. Zuki AB, Hafeez YM, Loqman MY, Noordin MM, Norimah Y
    Anat Histol Embryol, 2007 Oct;36(5):349-56.
    PMID: 17845224
    This study investigates the effect of preservation methods on the performance of bovine parietal pericardium grafts in a rat model. Mid-ventral full thickness abdominal wall defects of 3 x 2.5 cm in size were created in 90 male Sprague-Dawley rats (300-400 g), which were divided into three groups of 30 rats each. The abdominal defects of group one and two were repaired with lyophilized and glycerolized bovine pericardium grafts, while the defects of group three were repaired with expanded polytetrafluoroethylene (ePTFE) Mycro Mesh as a positive control. Another group of 30 rats underwent sham operation and was used for comparison as negative control. Each group of rats (n = 30) was divided into five subgroups (n = 6) and killed at 1, 3, 6, 9 and 18 weeks post-surgery for gross and morphological evaluations. The rats tolerated the surgical procedure well with a total mortality of 0.05%. No serious post-operative clinical complications or signs of rejection were encountered. Adhesions between the grafts and the underlying visceral organs observed in the study were mostly results of post-surgical complications. Glycerol preservation delayed degradation and replacement of the grafts, whereas lyophilization caused early resorption and replacement of the grafts. The glycerolized grafts were replaced with thick dense fibrous tissue, and the lyophilized grafts were replaced with thin loose fibrous tissue. The healing characteristic of the bovine pericardium grafts was similar to those of the sham-operated group, and quite different from those of the ePTFE Mycro Mesh. The outcome of the present study confirmed the superiority of glycerolized bovine pericardium grafts over its lyophilized counter part.
    Matched MeSH terms: Prosthesis Implantation
  2. Zubaidah NH, Azim MI, Osama MH, Harunarashid H, Das S
    Clin Ter, 2012;163(1):27-9.
    PMID: 22362230
    The incidence of infection following TEVAR is low. To the best of our knowledge, this is the first case report of post thoracic endovascular aortic repair (TEVAR) with Streptococcus viridans graft infection. A 54-year-old male underwent TEVAR for dissecting thoracic aneurysm with spinal ischaemia. He had an eventful recovery with prolonged period of stay in intensive care unit. Three months later, he presented with persistent chest discomfort and fever. Computed tomography (CT) of the thorax revealed evidence of graft infection and the blood culture grew Streptococcus viridans. The rarity of TEVAR graft infection due to Streptococcus viridans and its management are being discussed.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*
  3. Zainuddin NAMN, Razak NAA, Karim MSA, Osman NAA
    Sci Rep, 2023 Feb 15;13(1):2664.
    PMID: 36792914 DOI: 10.1038/s41598-022-21990-y
    Acrylic and epoxy are common types of resin used in fabricating sockets. Different types of resin will affect the internal surface of a laminated socket. This paper is to determine the best combination of ratio for epoxy and acrylic resin for a laminated prosthesis socket and to evaluate the surface profile analysis of different combinations of laminated prosthetic sockets for surface roughness. Transfemoral sockets were created using various resin-to-hardener ratios of 2:1, 3:1, 3:2, 2:3, and 1:3 for epoxy resin and 100:1, 100:2, 100:3, 100:4, and 100:5 for acrylic resin. Eight layers of stockinette consisting of four elastic stockinette and four Perlon stockinette were used. A sample with a size of 4 cm × 6 cm was cut out from the socket on the lateral side below the Greater Trochanter area. The Mitutoyo Sj-210 Surface Tester stylus was run through the sample and gave the Average Surface Roughness value (Ra), Root Mean Square Roughness value (Rq), and Ten-Point Mean Roughness value (Rz). Epoxy resin shows a smoother surface compared to acrylic resin with Ra values of is 0.766 µm, 0.9716 µm, 0.9847 µm and 1.5461 µm with 3:2, 3:1, 2:1 and 2:3 ratio respectively. However, for epoxy resin with ratio 1:3, the resin does not cure with the hardener. As for acrylic resin the Ra values are 1.0086 µm, 2.362 µm, 3.372 µm, 4.762 µm and 6.074 µm with 100: 1, 100:2, 100:5, 100:4 and 100:3 ratios, respectively. Epoxy resin is a better choice in fabricating a laminated socket considering the surface produced is smoother.
    Matched MeSH terms: Prosthesis Implantation
  4. Yusof NM, Oh CW, Oh JK, Kim JW, Min WK, Park IH, et al.
    Injury, 2009 Dec;40(12):1286-91.
    PMID: 19539282 DOI: 10.1016/j.injury.2009.02.020
    Although non-operative treatment is a mainstay of tibial fracture management in children, certain fractures require a surgical approach. However, choices concerning optimal methods and implants are difficult. The purpose of this study was to determine the effectiveness of percutaneous plating of tibial fractures in children.
    Matched MeSH terms: Prosthesis Implantation/methods
  5. Yakub MA, Dillon J, Krishna Moorthy PS, Pau KK, Nordin MN
    Eur J Cardiothorac Surg, 2013 Oct;44(4):673-81.
    PMID: 23447474 DOI: 10.1093/ejcts/ezt093
    Contemporary experience with mitral valve (MV) repair in the rheumatic population is limited. We aimed to examine the long-term outcomes of rheumatic MV repair, to identify the predictors of durability and to compare the repair for rheumatic and degenerative MVs.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/methods*
  6. Wong HS, Then KY, Ramli R
    Med J Malaysia, 2011 Oct;66(4):369-70.
    PMID: 22299563 MyJurnal
    We report the first case of Osteo-odonto-keratoprosthesis (OOKP) who successfully underwent surgery in Malaysia following a grade 4 (severe) chemical injury in both eyes in 2006. The patient's left eye was eviscerated and his right eye underwent penetrating keratoplasty. However, the corneal graft failed and became opaque. His right eye could only perceive light. The OOKP was offered to him hoping to recover some functional vision. He underwent a 2-stage surgery to implant the OOKP into his right eye. However, 2 months post-operation, he developed vitreous haemorrhage. A successful pars plana vitrectomy (PPV) was performed via the limited view through the lens. He attained a final visual acuity of 6/60 (N36). He was able to mobilize more independently, feed, dress himself and read large print.
    Matched MeSH terms: Prosthesis Implantation*
  7. Ulum MF, Arafat A, Noviana D, Yusop AH, Nasution AK, Abdul Kadir MR, et al.
    Mater Sci Eng C Mater Biol Appl, 2014 Mar 1;36:336-44.
    PMID: 24433920 DOI: 10.1016/j.msec.2013.12.022
    Biodegradable metals such as magnesium, iron and their alloys have been known as potential materials for temporary medical implants. However, most of the studies on biodegradable metals have been focusing on optimizing their mechanical properties and degradation behavior with no emphasis on improving their bioactivity behavior. We therefore investigated the possibility of improving iron biodegradation rate and bioactivity by incorporating various bioactive bioceramics. The iron-based bioceramic (hydroxyapatite, tricalcium phosphate and biphasic calcium phosphate) composites were prepared by mechanical mixing and sintering process. Degradation studies indicated that the addition of bioceramics lowered the corrosion potential of the composites and slightly increased their corrosion rate compared to that of pure iron. In vitro cytotoxicity results showed an increase of cellular activity when rat smooth muscle cells interacted with the degrading composites compared to pure iron. X-ray radiogram analysis showed a consistent degradation progress with that found in vivo and positive tissue response up to 70 days implantation in sheep animal model. Therefore, the iron-based bioceramic composites have the potential to be used for biodegradable bone implant applications.
    Matched MeSH terms: Prosthesis Implantation
  8. Tay JWT, Leong YP
    Med J Malaysia, 2012 Feb;67(1):111-2.
    PMID: 22582560 MyJurnal
    A 68 year old man with significant cardiorespiratory risks factors presented with a ruptured thoracic aortic aneurysm (TAA). This was treated by emergency thoracic endovascular aneurysm repair (TEVAR) under general anaesthesia (GA). An incidental abdominal aortic aneurysm (AAA) was not treated. Eight months later, he presented with ruptured AAA. Due to the patient's compromised respiratory system, he underwent endovascular aneurysm repair (EVAR) under local anaesthesia (LA). He had a smoother post-operation recovery compared to the first repair under GA.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  9. Tan AK, Pall S
    Med J Malaysia, 2011 Oct;66(4):284-5.
    PMID: 22299542 MyJurnal
    Matched MeSH terms: Prosthesis Implantation*
  10. Tamin SS, Hussin A, Za I, Halmey N, Azman W
    Pacing Clin Electrophysiol, 2007 Feb;30(2):276-9.
    PMID: 17338728
    Coronary sinus perforation is a relatively uncommon but much feared complication that may occur during the placement of left ventricular pacing lead. Coronary sinus perforation, especially in the presence of an obstructive flap, usually indicates the need to abandon the implantation attempt, as there are difficulties in crossing the obstructive flap as well as uncertainty of whether the lead is in the true lumen or into the pericardial space. We describe our experience in successfully placing the left ventricular lead safely despite the problems arising from these circumstances.
    Matched MeSH terms: Prosthesis Implantation/adverse effects*; Prosthesis Implantation/methods*
  11. Syed Alwi SA, Zainal Ariffin A, Hanif H, Naresh G
    Med J Malaysia, 2012 Oct;67(5):503-5.
    PMID: 23770868
    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysms undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All 4 patients were males with a mean age of 66.7 years. Only one (1) required ICU stay of 2 days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  12. Syed A, Zainal AA, Hanif H, Naresh G
    Med J Malaysia, 2012 Dec;67(6):610-2.
    PMID: 23770955 MyJurnal
    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysm undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All four patients were males with a mean age of 66.7 years. Only one required ICU stay of two days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  13. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
  14. Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, et al.
    Eur J Pharm Biopharm, 2019 Jun;139:272-278.
    PMID: 31004790 DOI: 10.1016/j.ejpb.2019.04.012
    OBJECTIVE: Vascular prostheses for small caliber bypass grafts in cardiac and vascular diseases or for access surgery are still missing. Poly (Ɛ-caprolactone) (PCL) has been previously investigated by our group and showed good biocompatibility and mechanical properties in vitro and rapid endothelialisation, cellular infiltration and vascularisation in vivo yielding optimal patency in the abdominal aortic position. The aim of the present study is to evaluate our PCL graft in the carotid position and to compare its outcome to the grafts implanted in the abdominal aortic position.

    METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.

    RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.

    CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation; Blood Vessel Prosthesis Implantation/methods*
  15. Sachithanandan A, Badmanaban B
    Interact Cardiovasc Thorac Surg, 2011 Jul;13(1):100.
    PMID: 21697404 DOI: 10.1510/icvts.2010.265264A
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  16. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*; Heart Valve Prosthesis Implantation/methods
  17. Razman J, Shaharin S, Lukman MR, Sukumar N, Jasmi AY
    Med J Malaysia, 2006 Jun;61(2):142-6.
    PMID: 16898302 MyJurnal
    Laparoscopic repair of ventral and incisional hernia has become increasingly popular as compared to open repair. The procedure has the advantages of minimal access surgery, reduction of post operative pain and the recurrence rate. A prospective study of laparoscopic incisional hernia repair was performed in our center from August 2002 to April 2004. Eighteen cases (n: 18) were performed during the study period. Fifteen cases (n: 15) had open hernia repair previously. Sixteen patients (n: 16) had successful repair of the hernia with the laparoscopic approach and two cases were converted to open repair. The mean hernia defect size was 156cm2. There was no intraoperative or immediate postoperative complication. The mean operating time was 100 +/- 34 minutes (75 - 180 minutes). The postoperative pain was graded as mild to moderate according to visual analogue score. The mean day of discharge after surgery was two days (1 - 3 days). During follow up, three patients (16.7%) developed seroma at the hernia sac which was resolved with conservative management after three weeks. One (5.6%) patient developed recurrence six months after surgery. In conclusion, laparoscopic repair of incisional hernia particularly recurrent hernia has been shown to be safe and effective in our centre. However, careful patient selection and acquiring the necessary advanced laparoscopic surgical skills coupled with the proper use of equipment are mandatory before embarking on this procedure.
    Matched MeSH terms: Prosthesis Implantation/methods*
  18. Ramlee MH, Ammarullah MI, Mohd Sukri NS, Faidzul Hassan NS, Baharuddin MH, Abdul Kadir MR
    Sci Rep, 2024 Mar 21;14(1):6842.
    PMID: 38514731 DOI: 10.1038/s41598-024-57454-8
    Previous research has primarily focused on pre-processing parameters such as design, material selection, and printing techniques to improve the strength of 3D-printed prosthetic leg sockets. However, these methods fail to address the major challenges that arise post-printing, namely failures at the distal end of the socket and susceptibility to shear failure. Addressing this gap, the study aims to enhance the mechanical properties of 3D-printed prosthetic leg sockets through post-processing techniques. Fifteen PLA + prosthetic leg sockets are fabricated and reinforced with four materials: carbon fiber, carbon-Kevlar fiber, fiberglass, and cement. Mechanical and microstructural properties of the sockets are evaluated through axial compression testing and scanning electron microscopy (SEM). Results highlight superior attributes of cement-reinforced sockets, exhibiting significantly higher yield strength (up to 89.57% more than counterparts) and higher Young's modulus (up to 76.15% greater). SEM reveals correlations between microstructural properties and socket strength. These findings deepen the comprehension of 3D-printed prosthetic leg socket post-processing, presenting optimization prospects. Future research can focus on refining fabrication techniques, exploring alternative reinforcement materials, and investigating the long-term durability and functionality of post-processed 3D-printed prosthetic leg sockets.
    Matched MeSH terms: Prosthesis Implantation
  19. Radzi, Z., Yahya, N.A., Zamzam, N., Spencer, R.J.
    Ann Dent, 2004;11(1):-.
    MyJurnal
    Missing teeth can be due to hypodontia, trauma or extraction. In general, the options for treatment depend on the severity of the hypodontia and the severity of the malocclusion. Occasionally, the space from missing teeth has to be maintained for prosthetic replacement and require an orthodontic/restorative approach. It is very important to ensure the space maintained is adequate for aesthetic reason so that it can be replaced with a prosthesis after the orthodontic treatment is completed. This article discusses a new innovation and clinical technique for maintaining this space during orthodontic treatment by using an acrylic tooth with several modifications. This innovation will be illustrated using two cases.
    Matched MeSH terms: Prosthesis Implantation
  20. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*; Heart Valve Prosthesis Implantation/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links