Displaying publications 1 - 20 of 269 in total

Abstract:
Sort:
  1. Aggarwal A, Court LE, Hoskin P, Jacques I, Kroiss M, Laskar S, et al.
    BMJ Open, 2023 Dec 07;13(12):e077253.
    PMID: 38149419 DOI: 10.1136/bmjopen-2023-077253
    INTRODUCTION: Fifty per cent of patients with cancer require radiotherapy during their disease course, however, only 10%-40% of patients in low-income and middle-income countries (LMICs) have access to it. A shortfall in specialised workforce has been identified as the most significant barrier to expanding radiotherapy capacity. Artificial intelligence (AI)-based software has been developed to automate both the delineation of anatomical target structures and the definition of the position, size and shape of the radiation beams. Proposed advantages include improved treatment accuracy, as well as a reduction in the time (from weeks to minutes) and human resources needed to deliver radiotherapy.

    METHODS: ARCHERY is a non-randomised prospective study to evaluate the quality and economic impact of AI-based automated radiotherapy treatment planning for cervical, head and neck, and prostate cancers, which are endemic in LMICs, and for which radiotherapy is the primary curative treatment modality. The sample size of 990 patients (330 for each cancer type) has been calculated based on an estimated 95% treatment plan acceptability rate. Time and cost savings will be analysed as secondary outcome measures using the time-driven activity-based costing model. The 48-month study will take place in six public sector cancer hospitals in India (n=2), Jordan (n=1), Malaysia (n=1) and South Africa (n=2) to support implementation of the software in LMICs.

    ETHICS AND DISSEMINATION: The study has received ethical approval from University College London (UCL) and each of the six study sites. If the study objectives are met, the AI-based software will be offered as a not-for-profit web service to public sector state hospitals in LMICs to support expansion of high quality radiotherapy capacity, improving access to and affordability of this key modality of cancer cure and control. Public and policy engagement plans will involve patients as key partners.

    Matched MeSH terms: Radiotherapy Planning, Computer-Assisted
  2. Meyers SM, Winter JD, Obeidi Y, Chung P, Menard C, Warde P, et al.
    Med Dosim, 2023 11 18;49(2):150-158.
    PMID: 37985297 DOI: 10.1016/j.meddos.2023.10.008
    Postoperative prostate radiotherapy requires large planning target volume (PTV) margins to account for motion and deformation of the prostate bed. Adaptive radiation therapy (ART) can incorporate image-guidance data to personalize PTVs that maintain coverage while reducing toxicity. We present feasibility and dosimetry results of a prospective study of postprostatectomy ART. Twenty-one patients were treated with single-adaptation ART. Conventional treatments were delivered for fractions 1 to 6 and adapted plans for the remaining 27 fractions. Clinical target volumes (CTVs) and small bowel delineated on fraction 1 to 4 CBCT were used to generate adapted PTVs and planning organ-at-risk (OAR) volumes for adapted plans. PTV volume and OAR dose were compared between ART and conventional using Wilcoxon signed-rank tests. Weekly CBCT were used to assess the fraction of CTV covered by PTV, CTV D99, and small bowel D1cc. Clinical metrics were compared using a Student's t-test (p < 0.05 significant). Offline adaptive planning required 1.9 ± 0.4 days (mean ± SD). ART decreased mean adapted PTV volume 61 ± 37 cc and bladder wall D50 compared with conventional treatment (p < 0.01). The CTV was fully covered for 96% (97%) of fractions with ART (conventional). Reconstructing dose on weekly CBCT, a nonsignificant reduction in CTV D99 was observed with ART (94%) compared to conventional (96%). Reduced CTV D99 with ART was significantly correlated with large anterior-posterior rectal diameter on simulation CT. ART reduced the number of fractions exceeding our institution's small bowel D1c limit from 14% to 7%. This study has demonstrated the feasibility of offline ART for post-prostatectomy cancer. ART facilitates PTV volume reduction while maintaining reasonable CTV coverage and can reduce the dose to adjacent normal tissues.
    Matched MeSH terms: Radiotherapy Dosage
  3. Chua GWY, Ho BS, Ng YY, Master ZR, Sultana R, Cheah P, et al.
    Int J Radiat Oncol Biol Phys, 2023 Oct 01;117(2S):e169-e170.
    PMID: 37784773 DOI: 10.1016/j.ijrobp.2023.06.1010
    PURPOSE/OBJECTIVE(S): Radiotherapy of synchronous bilateral breast cancer poses some technical challenges with regards to dose coverage and sparing of organs at risk (OAR). In this study, we aimed to evaluate dosimetric characteristics of 3 different techniques, IMPT vs photon (VMAT and HT). We hypothesized that IMPT would result in lower doses to organs at risk, as compared to the other 2 techniques.

    MATERIALS/METHODS: A total of 10 patients with synchronous bilateral breast cancer who were treated with VMAT at our institution were retrospectively analyzed. Clinical target volume (CTV) included chest wall and regional nodes (supraclavicular fossa and internal mammary chain) and prescription dose was 40.05 Gy in 15 daily fractions. HT and IMPT plans were generated for each patient. Dose-volume statistics, including planning target volume (PTV) coverage and dose to OAR: lungs, heart, thyroid, spinal cord, brachial plexus and esophagus, were compared between modalities using a paired T-test.

    RESULTS: Mean age of patients was 61 years (43-84). Majority of the patients (80%) were ER+ PR+ and HER2-. 40% of patients underwent breast reconstruction following surgery. All 3 techniques provided adequate target volume distribution and OAR sparing. Compared to VMAT and HT plans, IMPT had better heart and lung sparing effects, resulting in lower mean and V25 Gy heart dose; mean, V20 Gy and V5 Gy lung dose (p<0.0001). There was no significant difference in VMAT and HT plans for mean heart and lung dose. VMAT plans showed significantly lower V25 Gy heart dose on average (p = 0.04). V5 Gy lung dose was slightly lower in HT compared to VMAT plans, approaching statistical significance (p = 0.08). PTV coverage was adequate for all 3 techniques. All techniques fulfilled cord, esophagus, thyroid and brachial plexus constraints.

    CONCLUSION: IMPT plans showed significantly better OAR sparing compared to photon techniques. All 3 techniques met OAR constraints, and resulted in adequate target volume coverage. As IMPT is significantly more costly than VMAT or HT techniques, appropriate patient selection is important to deliver treatment in the most resource-effective manner for patients who would derive the most benefit, for example those with young age or existing heart or lung comorbidities.

    Matched MeSH terms: Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted/methods
  4. Yap LM, Jamalludin Z, Ng AH, Ung NM
    Phys Eng Sci Med, 2023 Sep;46(3):1331-1340.
    PMID: 37470929 DOI: 10.1007/s13246-023-01303-x
    The survey is to assess the current state of adaptive radiation therapy (ART) for head and neck (H&N) cases among radiotherapy centers in Malaysia and to identify any implementation limitations. An online questionnaire was sent to all radiotherapy centers in Malaysia. The 24-question questionnaire consists of general information about the center, ART practices, and limitations faced in implementing ART. 28 out of 36 radiotherapy centers responded, resulting in an overall response rate of 78%. About 52% of the responding centers rescanned and replanned less than 5% of their H&N patients. The majority (88.9%) of the respondents reported the use Cone Beam Computed Tomography alone or in combination with other modalities to trigger the ART process. The main reasons cited for adopting ART were weight loss, changes in the immobilization fitting, and anatomical variation. The adaptation process typically occurred during week 3 or week 4 of treatment. More than half of the respondents require three days or more from re-simulation to starting a new treatment plan. Both target and organ at risk delineation on new planning CT relied heavily on manual delineation by physicians and physicists, respectively. All centers perform patient-specific quality assurance for their new adaptive plans. Two main limitations in implementing ART are "limited financial resources or equipment" and "limitation on technical knowledge". There is a need for a common consensus to standardize the practice of ART and address these limitations to improve the implementation of ART in Malaysia.
    Matched MeSH terms: Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted/methods
  5. Bi S, Sun X, Sohaimi WFBW, Yusoff ALB
    Eur J Med Res, 2023 Aug 31;28(1):309.
    PMID: 37653551 DOI: 10.1186/s40001-023-01278-1
    OBJECTIVE: The aim of this study was to investigate the feasibility of VMAT library-derived model transfer in the prediction of IMRT plans by dosimetry comparison among with three groups of IMRT plans: two groups of automatic IMRT plans generated by the knowledge-based the volumetric modulated arc therapy (VMAT) model and intensity-modulated radiation therapy (IMRT) model and one group of manual IMRT plans.

    METHODS: 52 prostate cancer patients who had completed radiotherapy were selected and randomly divided into 2 groups with 40 and 12 separately. Then both VMAT and IMRT plans were manually designed for all patients. The total plans in the group with 40 cases as training datasets were added to the knowledge-based planning (KBP) models for learning and finally obtained VMAT and IMRT training models. Another 12 cases were selected as the validation group to be used to generated auto IMRT plans by KBP VMAT and IMRT models. At last, the radiotherapy plans from three groups were obtained: the automated IMRT plan (V-IMRT) predicted by the VMAT model, the automated IMRT plan (I-IMRT) predicted by the IMRT model and the manual IMRT plan (M-IMRT) designed before. The dosimetric parameters of planning target volume (PTV) and organ at risks (OARs) as well as the time parameters (monitor unit, MU) were statistically analyzed.

    RESULTS: The dose limit of all plans in the training datasets met the clinical requirements. Compared with the training plans added to VMAT model, the dosimetry parameters have no statistical differences in PTV (P > 0.05); the dose of X% volume (Dx%) with D25% and D35% in rectal and the maximum dose (Dmax) in the right femoral head were lower (P = 0.04, P = 0.01, P = 0.00) while D50% in rectal was higher ( 0.05), but the Dmax in left femoral heard and D15% in the right femoral head were lower and have significant differences (P  0.05).

    CONCLUSION: Compared with the manual plan, the IMRT plans generated by the KBP models had a significant advantage in dose control of both OARs and PTV. Compared to the I-IMRT plans, the V-IMRT plans was not only without significant disadvantages, but it also achieved slightly better control of the low-dose region, which meet the clinical requirements and can used in the clinical treatment. This study demonstrates that it is feasible to transfer the KBP VMAT model in the prediction of IMRT plans.

    Matched MeSH terms: Radiotherapy, Intensity-Modulated*
  6. Bradley DA, Essa RZ, Peh SC, Teow SY, Chew MT, Zubair HT, et al.
    Appl Radiat Isot, 2023 Aug;198:110875.
    PMID: 37257265 DOI: 10.1016/j.apradiso.2023.110875
    Review is provided of a number of low-dose, low dose rate situations that in study require advances in the development of dosimetric facilities. Using a clinical linac set up to provide doses down to the few mGy level, the performance of a real-time radioluminescence system has then been illustrated, accommodating pulsed as well as continuous dose delivery. The system gate times provide for tracking of the pattern of dose delivery, allowing detailed account of dose and dose-rate variations. The system has been tested in both x-ray and electron mode dose delivery.
    Matched MeSH terms: Radiotherapy Dosage
  7. Okonogi N, Kono S, Karasawa K, Banu PA, Xu X, Erawati D, et al.
    Clin Oncol (R Coll Radiol), 2023 Jul;35(7):463-471.
    PMID: 37179216 DOI: 10.1016/j.clon.2023.04.007
    AIMS: There is a need for the adequate distribution of healthcare resources in Southeast Asia. Many countries in the region have more patients with advanced breast cancer who are eligible for postmastectomy radiotherapy (PMRT). Therefore, it is critical that hypofractionated PMRT is effective in most of these patients. This study investigated the significance of postoperative hypofractionated radiotherapy in patients with breast cancer, including advanced breast cancer, in these countries.

    MATERIALS AND METHODS: Eighteen facilities in 10 Asian countries participated in this prospective, interventional, single-arm study. The study included two independent regimens: hypofractionated whole-breast irradiation (WBI) for patients who had undergone breast-conserving surgery and hypofractionated PMRT for patients who had undergone total mastectomy at a dose of 43.2 Gy in 16 fractions. In the hypofractionated WBI group, patients with high-grade factors received additional 8.1 Gy boost irradiation sessions for the tumour bed in three fractions.

    RESULTS: Between February 2013 and October 2019, 227 and 222 patients were enrolled in the hypofractionated WBI and hypofractionated PMRT groups, respectively. The median follow-up periods in the hypofractionated WBI and hypofractionated PMRT groups were 61 and 60 months, respectively. The 5-year locoregional control rates were 98.9% (95% confidence interval 97.4-100.0) and 96.3% (95% confidence interval 93.2-99.4) in the hypofractionated WBI and hypofractionated PMRT groups, respectively. Regarding adverse events, grade 3 acute dermatitis was observed in 2.2% and 4.9% of patients in the hypofractionated WBI and hypofractionated PMRT groups, respectively. However, no other adverse events were observed.

    CONCLUSION: Although further follow-up is required, hypofractionated radiotherapy regimens for postoperative patients with breast cancer in East and Southeast Asian countries are effective and safe. In particular, the proven efficacy of hypofractionated PMRT indicates that more patients with advanced breast cancer can receive appropriate care in these countries. Hypofractionated WBI and hypofractionated PMRT are reasonable approaches that can contain cancer care costs in these countries. Long-term observation is required to validate our findings.

    Matched MeSH terms: Radiotherapy, Adjuvant/adverse effects
  8. Ab Shukor NS, Abdullah R, Abdul Aziz MZ, Samson DO, Musarudin M
    Appl Radiat Isot, 2023 Jun;196:110751.
    PMID: 36871495 DOI: 10.1016/j.apradiso.2023.110751
    The present study was conducted to elucidate the effects of hip prostheses in 192Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron 192Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials considered in this study were water, bone, and metal prosthesis. According to the obtained results, a dose perturbation was observed within the medium with a higher atomic number, which reduced the dose to the nearby region.
    Matched MeSH terms: Radiotherapy Dosage
  9. Aminordin Sabri AH, Mohamad Tajudin S, Abdul Aziz MZ, Furuta T
    Radiol Phys Technol, 2023 Mar;16(1):109-117.
    PMID: 36729272 DOI: 10.1007/s12194-023-00703-8
    In a brachytherapy room irradiated with an Iridium-192 (192Ir) source, the spatial distributions of photon dose rates were measured and calculated for the dose distribution both inside and outside the room. The spatial distributions were measured using a thermoluminescent dosimeter (LiF-100) on the surfaces of the concrete walls and barriers of the irradiation room. The calculations were performed using the particle and heavy ion transport code system (PHITS) by considering the detailed model of the brachytherapy room and the radiation source used in the measurements. The measured and calculated doses exhibited a similar distribution pattern within and outside the brachytherapy room. To reduce the edge effect at the entrance door, the addition of a 3-mm thick lead layer on the surface of the concrete wall on the left doorstop is recommended. For the 60Co source, with the existing walls and lead door thickness, the dose at the control console and in front of the entrance maze increased by a factor of approximately 60.
    Matched MeSH terms: Radiotherapy Dosage
  10. Loh ZH, Mohamad S, Gan BC, Zakaria Z, Mohamad I
    Med J Malaysia, 2023 Mar;78(2):197-201.
    PMID: 36988530
    INTRODUCTION: Nasopharyngeal carcinoma (NPC) is among the most common malignancy in Malaysia. Radiationinduced hypothyroidism has been reported in other countries. However, in Malaysia, no studies were ever done to determine the effect of radiation on hypothyroidism. The objective of this study is to evaluate the practice of taking thyroid function test (TFT) and determine hypothyroidism post-radiation in patients with NPC.

    MATERIALS AND METHODS: A retrospective study on the symptoms and results of TFT according to the dosage of intensity-modulated radiotherapy (IMRT) given to patients with NPC. Data were traced and analysed.

    RESULTS: A total of 78 patients were identified. All patients received IMRT with 33-35 fractions of radiotherapy (RT) with total dosage of 66-70 Gray given. Not all patients had their thyroid function status measured routinely. Twelve patients did have symptoms of hypothyroidism. TFT were obtained in this group but the results were normal. No correlation was found between RT and hypothyroidism.

    CONCLUSION: There was no correlation between IMRT and the development of hypothyroidism. A prospective study with better control of inclusion and exclusion criteria, and longer follow-up period with TFT, is needed to demonstrate the consistency of these findings.

    Matched MeSH terms: Radiotherapy Dosage
  11. Entezam A, Fielding A, Bradley D, Fontanarosa D
    PLoS One, 2023;18(2):e0280765.
    PMID: 36730280 DOI: 10.1371/journal.pone.0280765
    Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
    Matched MeSH terms: Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted/methods
  12. Tabbakh F, Hosmane NS, Tajudin SM, Ghorashi AH, Morshedian N
    Sci Rep, 2022 Oct 18;12(1):17404.
    PMID: 36258012 DOI: 10.1038/s41598-022-22429-0
    There are two major problems in proton therapy. (1) In comparison with the gamma-ray therapy, proton therapy has only ~ 10% greater biological effectiveness, and (2) the risk of the secondary neutrons in proton therapy is another unsolved problem. In this report, the increase of biological effectiveness in proton therapy has been evaluated with better performance than 11B in the presence of two proposed nanomaterials of 157GdF4 and 157Gd doped carbon with the thermal neutron reduction due to the presence of 157Gd isotope. The present study is based on the microanalysis calculations using GEANT4 Monte Carlo tool and GEANT4-DNA package for the strand breaks measurement. It was found that the proposed method will increase the effectiveness corresponding to the alpha particles by more than 100% and also, potentially will decrease the thermal neutrons fluence, significantly. Also, in this work, a discussion is presented on a significant contribution of the secondary alpha particles in total effectiveness in proton therapy.
    Matched MeSH terms: Radiotherapy Dosage
  13. Salleh H, Azli S, Khairul-Asri MG, Jagwani A
    Ann R Coll Surg Engl, 2022 Mar;104(3):e67-e69.
    PMID: 34812665 DOI: 10.1308/rcsann.2021.0129
    Spontaneous urinary bladder rupture is a rare condition. Radiotherapy treatment for malignancy of a pelvic organ such as cervix or prostate is one cause of this condition. We report a case of a 71-year-old woman who presented with this illness 30 years after radiotherapy treatment.
    Matched MeSH terms: Uterine Cervical Neoplasms/radiotherapy; Radiotherapy/adverse effects
  14. See MH, Sinnadurai S, Lai LL, Tan KL, Teh MS, Teoh LY, et al.
    Surgery, 2021 12;170(6):1604-1609.
    PMID: 34538341 DOI: 10.1016/j.surg.2021.08.001
    BACKGROUND: Although immediate breast reconstruction is increasingly becoming popular worldwide, evidence from resource-limited settings is scarce. We investigated factors associated with immediate breast reconstruction in a multiethnic, middle-income Asian setting. Short-term surgical complications, timing of initiation of chemotherapy, and survival outcomes were compared between women undergoing mastectomy alone and their counterparts receiving immediate breast reconstruction.

    METHODS: This historical cohort study included women who underwent mastectomy after diagnosis with stage 0 to stage IIIa breast cancer from 2011 to 2015 in a tertiary hospital. Multivariable regression analyses were used to assess factors associated with immediate breast reconstruction and to measure clinical outcomes.

    RESULT: Out of 790 patients with early breast cancer who had undergone mastectomy, only 68 (8.6%) received immediate breast reconstruction. Immediate breast reconstruction was independently associated with younger age at diagnosis, recent calendar years, Chinese ethnicity, higher education level, and invasive ductal carcinomas. Although immediate breast reconstruction was associated with a higher risk of short-term local surgical complications (adjusted odds ratio: 3.58 [95% confidence interval 1.75-7.30]), there were no significant differences in terms of delay in initiation of chemotherapy, 5-year disease-free survival, and 5-year overall survival between both groups in the multivariable analyses.

    CONCLUSION: Although associated with short-term surgical complications, immediate breast reconstruction after mastectomy does not appear to be associated with delays in initiation of chemotherapy, recurrence, or mortality after breast cancer. These findings are valuable in facilitating shared surgical decision-making, improving access to immediate breast reconstruction, and setting priorities for surgical trainings in middle-income settings.

    Matched MeSH terms: Radiotherapy, Adjuvant/statistics & numerical data
  15. Martin CJ, Kron T, Vassileva J, Wood TJ, Joyce C, Ung NM, et al.
    Phys Med, 2021 Oct;90:53-65.
    PMID: 34562809 DOI: 10.1016/j.ejmp.2021.09.004
    Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.
    Matched MeSH terms: Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted; Radiotherapy, Image-Guided*
  16. Nazeri AAZA, Sani SFA, Ung NM, Almugren KS, Alkallas FH, Bradley DA
    Appl Radiat Isot, 2021 Oct;176:109814.
    PMID: 34175543 DOI: 10.1016/j.apradiso.2021.109814
    Brachytherapy is commonly used in treatment of cervical, prostate, breast and skin cancers, also for oral cancers, typically via the application of sealed radioactive sources that are inserted within or alongside the area to be treated. A particular aim of the various brachytherapy techniques is to accurately transfer to the targeted tumour the largest possible dose, at the same time minimizing dose to the surrounding normal tissue, including organs at risk. The dose fall-off with distance from the sources is steep, the dose gradient representing a prime factor in determining the dose distribution, also representing a challenge to the conduct of measurements around sources. Amorphous borosilicate glass (B2O3) in the form of microscope cover slips is recognized to offer a practicable system for such thermoluminescence dosimetry (TLD), providing for high-spatial resolution (down to 
    Matched MeSH terms: Radiotherapy Dosage*
  17. Jamalludin Z, Malik RA, Ung NM
    Phys Eng Sci Med, 2021 Sep;44(3):773-783.
    PMID: 34191272 DOI: 10.1007/s13246-021-01026-x
    Intracavitary cervical brachytherapy delivers high doses of radiation to the target tissue and a portion of these doses will also hit the rectal organs due to their close proximity. Rectal dose can be evaluated from dosimetric parameters in the treatment planning system (TPS) and in vivo (IV) dose measurement. This study analyzed the correlation between IV rectal dose with selected volume and point dose parameters from TPS. A total of 48 insertions were performed and IV dose was measured using the commercial PTW 9112 semiconductor diode probe. In 18 of 48 insertions, a single MOSkin detector was attached on the probe surface at 50 mm from the tip. Four rectal dosimetric parameters were retrospectively collected from TPS; (a) PTW 9112 diode maximum reported dose (RPmax) and MOSkin detector, (b) minimum dose to 2 cc (D2cc), (c) ICRU reference point (ICRUr), and (d) maximum dose from additional points (Rmax). The IV doses from both detectors were analyzed for correlation with these dosimetric parameters. This study found a significantly high correlation between IV measured dose from RPmax (r = 0.916) and MOSkin (r = 0.959) with TPS planned dose. The correlation between measured RPmax with both D2cc and Rmax revealed high correlation of r > 0.7, whereas moderate correlation (r = 0.525) was observed with ICRUr. There was no significant correlation between MOSkin IV measured dose with D2cc, ICRUr and Rmax. The non-significant correlation between parameters was ascribable to differences in both detector position within patients, and dosimetric volume and point location determined on TPS, rather than detector uncertainties.
    Matched MeSH terms: Radiotherapy Dosage
  18. Wong MSL, Prepageran N
    J Laryngol Otol, 2021 Aug;135(8):691-694.
    PMID: 34342558 DOI: 10.1017/S0022215121001560
    OBJECTIVE: Eustachian tube dysfunction is a known complication following radiotherapy to the head and neck region. Unfortunately, treatment options are limited, with significant associated morbidity. Balloon Eustachian tube dilatation has been used successfully to treat Eustachian tube dysfunction; hence, this study aimed to determine the safety and efficacy of this method in treating Eustachian tube dysfunction in post-radiotherapy patients with nasopharyngeal carcinoma.

    METHOD: This interventional cohort pilot study on patients with Eustachian tube dysfunction compared those with nasopharyngeal carcinoma to patients without. Outcome assessment was based on tympanometry type and Eustachian Tube Dysfunction Questionnaire score.

    RESULTS: A total of 14 ears (12 patients) were tested. Only 14 per cent of the nasopharyngeal carcinoma cohort showed improvement, while 71 per cent of the non-nasopharyngeal carcinoma group were successfully treated. No significant adverse effect was reported in any patient during this study.

    CONCLUSION: Balloon Eustachian tube dilatation was not shown to be beneficial for post-radiotherapy Eustachian tube dysfunction in nasopharyngeal carcinoma patients in the preliminary stages of this pilot study.

    Matched MeSH terms: Nasopharyngeal Neoplasms/radiotherapy*
  19. Begum M, Rahman AKMM, Abdul-Rashid HA, Yusoff Z, Mat Nawi SN, Khandaker MU, et al.
    Appl Radiat Isot, 2021 Aug;174:109771.
    PMID: 34048992 DOI: 10.1016/j.apradiso.2021.109771
    Present study concerns the key thermoluminescence (TL) properties of photonic crystal fibres (PCFs), seeking development of alternatively structured TL materials that are able to offer a advantages over existing passive dosimeters. In terms of their internal structure and light guiding properties the PCFs, collapsed and structured, differ significantly from that of conventional optical fibres. To investigate the dosimetric parameters of the PCFs use was made of a linear accelerator producing a 6 MV photon beam, delivering doses ranging from 0.5 Gy to 8 Gy. The parameters studied included TL response, linearity index, glow curves, relative sensitivity and TL signal fading, the results being compared against those obtained using TLD-100 chips. At 4 Gy photon dose the Ge-doped collapsed PCFs were found to provide a response 27 × that of structured PCF, also giving a TL yield similar to that of standard TLD-100 chips. Over post-irradiation periods of 15 and 30 days collapsed PCF TL signal fading were 8% and 17% respectively, with corresponding values of 37% and 64% for the structured PCF. Trapping parameters including the order of kinetics (b), activation energy (E) and frequency factor (s-1) were assessed with Chen's peak shape method. Lifetime of trapping centre was found to be (2.36 E+03) s and (9.03 E +01) s regarding the collapsed and structured PCF respectively with 6 Gy of photon beam. For the Ge-doped collapsed PCF, the high TL yield, sensitivity and low fading provide the basis of a highly promising system of TLD for radiotherapy applications.
    Matched MeSH terms: Radiotherapy Dosage*
  20. Chew MT, Daar E, Khandaker MU, Jones B, Nisbet A, Bradley DA
    Br J Radiol, 2021 Aug 01;94(1124):20201265.
    PMID: 34192471 DOI: 10.1259/bjr.20201265
    Infection, the invasion of pathogenic microorganisms and viruses, causes reactive inflammation mediated by endogenous signals, with influx of leucocytes with distinct properties and capable of mounting a cellular or antibody response. Different forms of inflammation may also occur in response to tumours, in allergy and autoimmune disorders. Pneumonia, respiratory tract infection and septic shock for instance can arise as serious complications of the Covid-19 virus. While radiotherapy has been most widely used to control malignant tumours, it has also been used for treatment of non-malignant diseases, including acute and chronic inflammation in situations where anti-inflammatory drugs may be ineffective or contraindicated. The present review examines the history and prospects for low-dose anti-inflammatory radiation treatments, the present interest largely being motivated by the increased incidence of pulmonary disease associated Covid-19 infections. Evidence in support of the suggested efficacy are covered, together with an appraisal of one of the number of potential convenient sources that could complement external beam arrangements.
    Matched MeSH terms: Asthma/radiotherapy*; Pneumonia/radiotherapy*; Radiotherapy Dosage; Respiratory Distress Syndrome, Adult/radiotherapy*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links