Displaying publications 1 - 20 of 55 in total

Abstract:
Sort:
  1. Zhu Z, Pan X, Zhong F, Tian J, Ong MLY
    Nurs Open, 2023 May;10(5):2819-2830.
    PMID: 36575646 DOI: 10.1002/nop2.1572
    AIM: To understand Baduanjin rehabilitation therapy in mild COVID-19 patients.

    DESIGN: A narrative review.

    METHODS: A literature search for COVID-19 and Baduanjin treatments was conducted on Chinese and English electronic databases: China National Knowledge Infrastructure, Wanfang Data, Embase, PubMed, Scopus, Science Direct, Ebscohost, SPORTDiscus and ProQuest.

    RESULTS: Twelve studies on the Baduanjin rehabilitation for COVID-19 patients have been included. We acknowledged the considerable published research and current clinical practice using Baduanjin for COVID-19 treatment in the following areas: anxiety, depression, insomnia, lung function rehabilitation, immunity and activity endurance.

    CONCLUSION: The use of Baduanjin as adjuvant therapy for COVID-19 patients' rehabilitation is still limited, therefore, more clinical studies are needed to confirm its efficacy.

    Matched MeSH terms: Respiratory Function Tests
  2. Zariyantey Abdul Hamid, Zaliha Harun, Syarif Husin Lubis, Nihayah Mohamed, Ismarulyusda Ishak, Hidayatul Fathi Othman, et al.
    MyJurnal
    Health awareness promotion among farming communities are important for a sustainable agriculture activities. A cross-sectional study was conducted to assess health status among farming communities in Cameron Highlands, Pahang (n = 61) and Bachok and Pasir Puteh, Kelantan (n = 143). Mobile Health Screening Programme composed of assessment of blood glucose, blood cholesterol, haemoglobin, blood pressure, pterygium, lung function and nerve conductive velocity was utilized. Our results indicate that the percentage of Cameron Highland’s farmers with hyperglycaemia, systolic hypertension, diastolic hypertension and anaemia were 8.2%, 14.8%, 11.5% and 8.2%, respectively. However, higher percentage of farmers in Bachok and Pasir Puteh, Kelantan with hyperglycaemia (32.8%), hypercholesterolaemia (83%), anaemia (24.2%) and systolic hypertension (41.9%) were observed. Pterygium was positive for 88.6% of farmers in Cameron Highlands and 94.4% in Bachok and Pasir Puteh. Lung function test shows that 61.7% and 11.4% of farmers in Cameron Highlands had restrictive and obstructive lung, respectively. In Bachok and Pasir Puteh, a total of 19.8%, 55.5% and 23.9% of farmers were found to have obstructive, restrictive and combined obstructive and restrictive lung, respectively. Current Perception Threshold (CPT) value which indicate nerve conductive velocity were significantly increased (p < 0.05) among Cameron Highland’s farmers for both median and peroneal nerve at all frequencies (5 Hz, 250 Hz and 2000 Hz). In Bachok and Pasir Puteh, the values of the CPT for median nerve was significantly increased (p < 0.05) for all frequencies (5, 250 and 2000 Hz). Meanwhile, a signifi cant increased (p < 0.05) was observed for the CPT values for peroneal nerve at the frequencies of 250 and 2000 Hz as compared to control groups. In conclusion, analysis revealed different health problem among the studied farming communities which could be influenced by the differences in farming practices. Thus, employed Mobile Health Screening Programme offers a monitoring approach that could highlight the need for suitable health services and awareness programmes for different farming communities.
    Matched MeSH terms: Respiratory Function Tests
  3. Zainudin NM, Aziz BA, Haifa AL, Deng CT, Omar AH
    Respirology, 2001 Jun;6(2):151-5.
    PMID: 11422895
    OBJECTIVE: Exercise-induced bronchoconstriction (EIB) may be demonstrated in 60-70% of asthmatic children in temperate climates. In areas of high humidity it is postulated to be low. The aim of the study was to determine the prevalence of EIB in a population of schoolchildren with wheezing, living in the humid tropical climate of Kuala Lumpur, Malaysia.

    METHOD: We performed a cross-sectional study using the International Study of Asthma and Allergies in Childhood questionnaire to identify 7-12-year-old Malay children with asthma symptoms from a primary school in central Kuala Lumpur. Sixty-five of 76 children with 'ever wheeze' performed an exercise challenge test successfully in an uncontrolled environment. A random sample of 80 schoolchildren with no history of wheeze were similarly tested as controls. The relative humidity and temperature were recorded. A fall of > 15% was considered as clinically important.

    RESULTS: The prevalence of EIB in schoolchildren with 'ever wheeze' was 47.7%. The prevalence of EIB in children with 'current wheeze' was 51.6%. The prevalence of EIB in controls was 7.5%. The relative humidity during the study ranged from 41 to 90%. There was no significant relationship between different humidity levels and EIB (P = 0.58, regression analysis).

    CONCLUSION: This study demonstrates that EIB is present in asthmatic children despite the highly humid tropical environment.

    Matched MeSH terms: Respiratory Function Tests
  4. Zainudin BM, Roslina AM, Fadilah SA, Samad SA, Sufarlan AW, Isa MR
    Med J Malaysia, 1996 Mar;51(1):136-40.
    PMID: 10967994
    Three cases of diffuse panbronchiolitis (DPB) occurring in two Malaysian Chinese patients and one Malay patient are reported. They had similar clinical, radiological and physiological features which are characteristic of DPB. The diagnosis in one of the cases was confirmed histologically by transbronchial lung biopsy. These could be the first three cases identified in Malaysia.
    Matched MeSH terms: Respiratory Function Tests
  5. Zainal N, Rahardja A, Faris Irfan CY, Nasir A, Wan Pauzi WI, Mohamad Ikram I, et al.
    Singapore Med J, 2016 Dec;57(12):690-693.
    PMID: 26805669 DOI: 10.11622/smedj.2016019
    INTRODUCTION: This study aimed to determine the prevalence of asthma-like symptoms among schoolchildren with low birth weight (LBW), and to compare the lung function of these children with that of children with normal birth weight.

    METHODS: This was a comparative cross-sectional study. We recruited children aged 8-11 years from eight primary schools in Kota Bharu, Kelantan, Malaysia. The children were divided into two groups: those with LBW (< 2,500 g) and those with normal birth weight (≥ 2,500 g). Parents of the enrolled children were asked to complete a translated version of the International Study of Asthma and Allergies in Childhood questionnaire. Lung function tests, done using a MicroLoop Spirometer, were performed for the children in both groups by a single investigator who was blinded to the children's birth weight.

    RESULTS: The prevalence of 'ever wheezed' among the children with LBW was 12.9%. This value was significantly higher than that of the children with normal birth weight (7.8%). Forced vital capacity (FVC), forced expiratory volume in one second, and forced expiratory flow when 50% and 75% of the FVC had been exhaled were significantly lower among the children with LBW as compared to the children with normal birth weight.

    CONCLUSION: LBW is associated with an increased prevalence of asthma-like symptoms and impaired lung function indices later in life. Children born with LBW may need additional follow-up so that future respiratory problems can be detected early.

    Matched MeSH terms: Respiratory Function Tests
  6. Zafar Ahmed, Sharifa Ezat Wan Puteh, Aisha Abdussalam, Mahmud Hanesh, Suriati Sukeri, Joseph, Leonard
    Int J Public Health Res, 2012;2(1):65-74.
    MyJurnal
    OBJECTIVE. Chronic obstructive pulmonary disease (COPD) is a one of the major cause of death and disability worldwide. This study aimed to compare the quality of life (QOL), Activity of Daily Living (ADL), Pulmonary Function Test (PFT) and general health symptoms pre and after hospital-based respiratory physiotherapy program among COPD patients. METHODS. Pre and post intervention study was conducted between January and July 2010. A total of 54 subjects aged between 30 to 40 years old were recruited for this study using universal sampling method from Alzawia Teaching Hospital, Libya. Data collected were socio-demographic data, QOL (before and after the intervention) using the Short Form-36 (SF-36) questionnaire, ADL using the Barthel Index and the General Health Symptoms.
    RESULTS.. The mean SF-36 score for QOL is 30.13 (SD = 8.06) and 63.46 (SD = 13.53) before and after the physiotherapy respectively (with the p <0.0001). Patients’ Activity of Daily Living mean scores are 70.18, (SD = 16.50) and mean = 88.89 (SD = 13.28) before and after program (p< 0.0001). The general medical condition mean score after respiratory physiotherapy is 3.72 as compared to 4.96 before the respiratory physiotherapy (p< 0.0001). Pulmonary Function Test shows improvement in actual/predicted FEV1 ratio in all 54 cases with mean improvement from 55.85 before to 81.67 after the pulmonary physiotherapy (with the p <0.0001).
    CONCLUSION. Hospital based respiratory physiotherapy program had significantly improved QOL, pulmonary function and activities of daily living among the subjects.
    Matched MeSH terms: Respiratory Function Tests
  7. Wu CL, Hsu WH, Chiang CD, Kao CH, Hung DZ, King SL, et al.
    J. Toxicol. Clin. Toxicol., 1997;35(3):241-8.
    PMID: 9140317 DOI: 10.3109/15563659709001207
    BACKGROUND: Taking Sauropus androgynus, a Malaysian food, to reduce weight began as a fad in Taiwan in 1994. Some advocates of this fad developed pulmonary dysfunction. The aim of this study is to report the lung injury in patients taking Sauropus androgynus.

    METHODS: From July 1995 to November 1995, we investigated 104 nonsmoking patients (one male and 103 females) with chest roentgenography, pulmonary function, test, and Technetium 99m-labeled diethylene triamine penta-acetate (Tc-99m DTPA) radioaerosol inhalation lung scintigraphy.

    RESULTS: Among the 90 patients receiving Tc-99m DTPA inhalation lung scan, 46 (51.1%) patients had increased clearance of Tc-99m DTPA from lung and 20 (22.2%) patients had inhomogeneous deposition of the submicronic radioaerosol. Eighteen (18/100) patients had obstructive ventilatory impairment in pulmonary function test. Analyzing the results, we found that the patients with respiratory symptoms (n = 42) took more vegetables (p = 0.016), had increased clearance of Tc-99m DTPA (p = 0.010) and had lower FEV1 (p = 0.001), FEV1/FVC (p < 0.001), FEF25-75 (p = 0.001), VC (p = 0.002) and DLCO (p = 0.009) than the patients without respiratory symptoms (n = 62). FEV1 and FEV1/FVC were significantly reduced in patients with severe impairment of alveolar permeability. The cumulative dosage and duration of exposure were significantly associated with the reduction of FEV1 and FEV1/FVC.

    CONCLUSION: The lung injury after taking Sauropus androgynus involves alveoli and/or small airways and is manifest as obstructive ventilatory impairment with inhomogeneous aerosol distribution and increased lung epithelial permeability.
    Matched MeSH terms: Respiratory Function Tests
  8. Wan Muhammad Hatta SF, Kandaswamy L, Gherman-Ciolac C, Mann J, Buch HN
    PMID: 30087779 DOI: 10.1530/EDM-18-0074
    Myopathy is a well-known complication of hypercortisolism and commonly involves proximal lower-limb girdle. We report a rare case of Cushing's syndrome in a 60-year-old female presenting with significant respiratory muscle weakness and respiratory failure. She had history of rheumatoid arthritis, primary biliary cirrhosis and primary hypothyroidism and presented with weight gain and increasing shortness of breath. Investigations confirmed a restrictive defect with impaired gas transfer but with no significant parenchymatous pulmonary disease. Respiratory muscle test confirmed weakness of respiratory muscles and diaphragm. Biochemical and radiological investigations confirmed hypercortisolaemia secondary to a left adrenal tumour. Following adrenalectomy her respiratory symptoms improved along with an objective improvement in the respiratory muscle strength, diaphragmatic movement and pulmonary function test.

    Learning points: Cushing's syndrome can present in many ways, a high index of suspicion is required for its diagnosis, as often patients present with only few of the pathognomonic symptoms and signs of the syndrome.Proximal lower-limb girdle myopathy is common in Cushing's syndrome. Less often long-term exposure of excess glucocorticoid production can also affect other muscles including respiratory muscle and the diaphragm leading to progressive shortness of breath and even acute respiratory failure.Treatment of Cushing's myopathy involves treating the underlying cause that is hypercortisolism. Various medications have been suggested to hinder the development of GC-induced myopathy, but their effects are poorly analysed.

    Matched MeSH terms: Respiratory Function Tests
  9. Townend J, Minelli C, Mortimer K, Obaseki DO, Al Ghobain M, Cherkaski H, et al.
    Eur Respir J, 2017 06;49(6).
    PMID: 28572124 DOI: 10.1183/13993003.01880-2016
    Poverty is strongly associated with mortality from COPD, but little is known of its relation to airflow obstruction.In a cross-sectional study of adults aged ≥40 years from 12 sites (N=9255), participating in the Burden of Obstructive Lung Disease (BOLD) study, poverty was evaluated using a wealth score (0-10) based on household assets. Obstruction, measured as forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) (%) after administration of 200 μg salbutamol, and prevalence of FEV1/FVC
    Matched MeSH terms: Respiratory Function Tests
  10. Takaki S, Kadiman SB, Tahir SS, Ariff MH, Kurahashi K, Goto T
    J Cardiothorac Vasc Anesth, 2015 Feb;29(1):64-8.
    PMID: 25620140 DOI: 10.1053/j.jvca.2014.06.022
    The aim of this study was to determine the best predictors of successful extubation after cardiac surgery, by modifying the rapid shallow breathing index (RSBI) based on patients' anthropometric parameters.
    Matched MeSH terms: Respiratory Function Tests/methods
  11. Singh R, Singh HJ, Sirisinghe RG
    Jpn. J. Physiol., 1989;39(4):475-85.
    PMID: 2601189
    Lung capacity and maximum oxygen uptake (VO2max) were measured directly in 167 healthy males, from all the main races in Malaysia. Their ages ranged from 13 to 59 years. They were divided into five age groups (A to E), ranging from the second to the sixth decade. Lung capacities were determined using a dry spirometer and VO2max was taken as the maximum rate of oxygen consumption during exhaustive exercise on a cycle ergometer. Mean forced vital capacity (FVC) was 3.3 +/- 0.5 l and it correlated negatively with age. Mean VO2max was 3.2 +/- 0.2 l.min-1 (56.8 +/- 3.5 ml.kg-1.min-1) in Group A (13-19 years) compared to 1.7 +/- 0.2 l.min-1 (28.9 +/- 2.9 ml.kg-1.min-1) in Group E (50-59 years). Regression analysis revealed an age-related decline in VO2max of 0.77 ml.kg-1.min-1.year-1. Multiple regression of the data gave the following equations for the prediction of an individual's VO2max: VO2max (l.min-1) = 1.99 + 0.035 (weight)-0.04 (age), VO2max (ml.kg-1.min-1) = 67.7-0.77 (age), where age is in years, weight in kg. In terms of VO2max as an index of cardiopulmonary performance. Malaysians have a relatively lower capacity when related to the Swedish norms or even to those of some Chilean workers. Malaysians were, however, within the average norms of the American Heart Association's recommendations. Age-related decline in VO2max was also somewhat higher in the Malaysians.
    Matched MeSH terms: Respiratory Function Tests
  12. Singh OP, Ahmed IB, Malarvili MB
    Technol Health Care, 2018;26(5):785-794.
    PMID: 30124456 DOI: 10.3233/THC-181288
    BACKGROUND: Assessment of asthma outside of the hospital using a patient independent device is highly in demand due to the limitation of existing devices, which are manual and unreliable if patients are not cooperative.

    OBJECTIVE: The study aims to verify the use of newly developed human respiration, carbon dioxide (CO2) measurement device for the management of asthma outside of the hospital.

    METHOD: The data were collected from 60 subjects aged between 18-35 years via convenience sampling method reported in UTM Health Center using the device. Furthermore, the data were normalized and analyzed using descriptive statistics, t-test, and area (Az) under receiver operating characteristic curve (ROC).

    RESULT: Findings revealed that the normalized mean values of end-tidal carbon dioxide (EtCO2), Hjorth Activity (HA), and respiratory rate (RR) were lower in asthmatic compared with healthy subjects with minimum deviation from the mean. In addition, each parameter was found to significantly differ statistically for asthma and non-asthma with p< 0.05. Furthermore, the Az shows the strong association for the screening of asthma and non-asthma with an average of 0.71 (95% CI: 0.57-0.83), 0.77 (95% CI: 0.64-0.90), and 0.83 (95% CI: 0.73-0.94) for RR, EtCO2, and HA, respectively.

    CONCLUSIONS: This study demonstrates that the newly developed handheld human respiration CO2 measurement device may possibly be used as an effort-independent asthma management method outside of the hospital.
    Matched MeSH terms: Respiratory Function Tests
  13. Sibel O, Beyza A, Murat K, Fatma E, Göksel K, Sevin B
    Med J Malaysia, 2012 Aug;67(4):375-8.
    PMID: 23082444
    Dyes are known to be a causative agent of occupational asthma exposed to them. We evaluate respiratory symptoms among textile. The study population comprised 106 exposed workers and control (unexposed) group. Data were collected by a questionnaire. Pulmonary Function Tests (PFTs) were performed. Among the exposed workers 36.8% defined phlegm. Respiratory symptoms were not significantly different between two groups. The employment duration of the exposed workers with phlegm was longer than those without phlegm (p = 0.027). The mean % predicted of forced expiratory flow (FEF) 25-75 of the exposed workers was found to be significantly lower than the control (unexposed) group (p = 0.01). Our study suggests that textile dyeing might cause respiratory symptoms at workers.
    Matched MeSH terms: Respiratory Function Tests
  14. Sairin ME, Mat Baki M, Manap RA, Puteh SEW, Azman M, Mohamed AS
    Auris Nasus Larynx, 2020 Oct;47(5):842-848.
    PMID: 32273190 DOI: 10.1016/j.anl.2020.03.004
    OBJECTIVE: This study investigated the reliability of body plethysmography in comparison to spirometry in objectively measuring upper airway functions.

    METHODS: The study population consisted of 53 participants, 23 patients with BVFI after endolaryngeal laser posterior cordectomy and 30 healthy volunteers. All of them had body plethysmography (airway resistance, Raw), spirometry (ratio of forced expiratory flow at 50% to forced inspiratory flow at 50%, FEF50/FIF50 and peak inspiratory flow, PIF), 6 min-walking-test (6MWT) and Medical Research Council (MRC) dyspnea scale measurements. The tests were repeated and reliability was evaluated using intraclass correlation (ICC) and Spearman correlation.

    RESULTS: The reliability of Raw was high with ICC of 0.92, comparable to the spirometry measurements: FEF50/FIF50(ICC = 0.72) and PIF (ICC = 0.97). The mean of Raw was significantly higher in patient group. A strong significant correlation between Raw and MRC dyspnea scale (r = 0.79; p<0.05) and a moderate negative correlation between Raw and 6MWT (r = 0.4; p<0.05) was demonstrated.

    CONCLUSION: Body plethysmography (Raw) is a reliable tool in objective measurement of upper airway resistance that reflects the patient's perception of breathlessness. A larger number of participants are necessary to confirm this finding.

    Matched MeSH terms: Respiratory Function Tests
  15. Redmond DP, Chiew YS, Major V, Chase JG
    Comput Methods Programs Biomed, 2019 Apr;171:67-79.
    PMID: 27697371 DOI: 10.1016/j.cmpb.2016.09.011
    Monitoring of respiratory mechanics is required for guiding patient-specific mechanical ventilation settings in critical care. Many models of respiratory mechanics perform poorly in the presence of variable patient effort. Typical modelling approaches either attempt to mitigate the effect of the patient effort on the airway pressure waveforms, or attempt to capture the size and shape of the patient effort. This work analyses a range of methods to identify respiratory mechanics in volume controlled ventilation modes when there is patient effort. The models are compared using 4 Datasets, each with a sample of 30 breaths before, and 2-3 minutes after sedation has been administered. The sedation will reduce patient efforts, but the underlying pulmonary mechanical properties are unlikely to change during this short time. Model identified parameters from breathing cycles with patient effort are compared to breathing cycles that do not have patient effort. All models have advantages and disadvantages, so model selection may be specific to the respiratory mechanics application. However, in general, the combined method of iterative interpolative pressure reconstruction, and stacking multiple consecutive breaths together has the best performance over the Dataset. The variability of identified elastance when there is patient effort is the lowest with this method, and there is little systematic offset in identified mechanics when sedation is administered.
    Matched MeSH terms: Respiratory Function Tests/standards*
  16. Rawi NA, Jalaludin J, Chua PC
    Biomed Res Int, 2015;2015:248178.
    PMID: 25984527 DOI: 10.1155/2015/248178
    Indoor air quality (IAQ) has been the object of several studies due to its adverse health effects on children. Methods. A cross-sectional comparative study was carried out among Malay children in Balakong (2 studied preschools) and Bangi (2 comparative preschools), Selangor, with the aims of determining IAQ and its association with respiratory health. 61 and 50 children aged 5-6 years were selected as studied and comparative groups. A questionnaire was used to obtain an exposure history and respiratory symptoms. Lung function test was carried out. IAQ parameters obtained include indoor concentration of particulate matter (PM), volatile organic compounds (VOCs), carbon monoxide (CO), carbon dioxide (CO2), temperature, air velocity (AV), and relative humidity. Results. There was a significant difference between IAQ in studied and comparative preschools for all parameters measured (P < 0.001) except for CO2 and AV. Studied preschools had higher PM and CO concentration. FVC, FEV1, FVC% and FEV1% predicted values were significantly lower among studied group. Exposures to PM, VOCs, and CO were associated with wheezing. Conclusion. The finding concluded that exposures to poor IAQ might increase the risk of getting lung function abnormality and respiratory problems among study respondents.
    Matched MeSH terms: Respiratory Function Tests
  17. Rasmussen LD, Pedersen C, Madsen HD, Laursen CB
    BMJ Case Rep, 2017 Nov 29;2017.
    PMID: 29191821 DOI: 10.1136/bcr-2017-221025
    A 36-year-old Danish man, living in Asia, was diagnosed with Pneumocystis pneumonia (PCP) and HIV in 2013 (CD4+ count: 6 cells/µL; viral load: 518 000 copies/mL). He initiated combination antiretroviral therapy. Later that year, he was also diagnosed with granulomatosis with polyangiitis and was treated with prednisolone. Despite complete viral suppression and increasing CD4+ count (162 cells/µL), he was readmitted with PCP in April 2015. Subsequently, he returned to Denmark (CD4+ count: 80 cells/µL, viral suppression). Over the following months, he developed progressive dyspnoea. Lung function tests demonstrated severely reduced lung capacity with an obstructive pattern and a moderately reduced diffusion capacity. High resolution computer tomography revealed minor areas with tree-in-bud pattern and no signs of air trapping on expiratory views. Lung biopsy showed lymphocytic infiltration surrounding the bronchioles with sparing of the alveolar septa. He was diagnosed with follicular bronchiolitis. The patient spontaneously recovered along with an improvement of the immune system.
    Matched MeSH terms: Respiratory Function Tests
  18. Rahman NN, Singh DK, Lee R
    Clin Interv Aging, 2017;12:523-529.
    PMID: 28352165 DOI: 10.2147/CIA.S110329
    Aging is associated with alterations in thoracolumbar curvatures and respiratory function. Research information regarding the correlation between thoracolumbar curvatures and a comprehensive examination of respiratory function parameters in older adults is limited. The aim of the present study was to examine the correlation between thoracolumbar curvatures and respiratory function in community-dwelling older adults. Thoracolumbar curvatures (thoracic and lumbar) were measured using a motion tracker. Respiratory function parameters such as lung function, respiratory rate, respiratory muscle strength and respiratory muscle thickness (diaphragm and intercostal) were measured using a spirometer, triaxial accelerometer, respiratory pressure meter and ultrasound imaging, respectively. Sixty-eight community-dwelling older males and females from Kuala Lumpur, Malaysia, with mean (standard deviation) age of 66.63 (5.16) years participated in this cross-sectional study. The results showed that mean (standard deviation) thoracic curvature angle and lumbar curvature angles were -46.30° (14.66°) and 14.10° (10.58°), respectively. There was a significant negative correlation between thoracic curvature angle and lung function (forced expiratory volume in 1 second: r=-0.23, P<0.05; forced vital capacity: r=-0.32, P<0.05), quiet expiration intercostal thickness (r=-0.22, P<0.05) and deep expiration diaphragm muscle thickness (r=-0.21, P<0.05). The lumbar curvature angle had a significant negative correlation with respiratory muscle strength (r=-0.29, P<0.05) and diaphragm muscle thickness at deep inspiration (r=-0.22, P<0.05). However, respiratory rate was correlated neither with thoracic nor with lumbar curvatures. The findings of this study suggest that increase in both thoracic and lumbar curvatures is correlated with decrease in respiratory muscle strength, respiratory muscle thickness and some parameters of lung function. Clinically, both thoracic and lumbar curvatures, respiratory muscles and lung function should be taken into consideration in the holistic management of respiratory function among older adults.
    Matched MeSH terms: Respiratory Function Tests
  19. Putri Anis Syahira Mohamad Jamil, Karmegam Karuppiah, Irniza Rasdi, Shamsul Bahri Mohd Tamrin, Sivasankar Sambasivam, Nur Athirah Diyana Mohammad Yusof, et al.
    MyJurnal
    Traffic policemen are exposed to polluted air for a long time in high concentrations since they are working outside for most of the time which is bad for their health. Hence, this study was to determine the prevalence of respiratory symptoms and pulmonary function among traffic police in Kuala Lumpur and Johor Bahru. Methods: A pulmonary function test using spirometer was used to measure the pulmonary function of subjects. A questionnaire on respiratory symptoms translated version from IUALTD was used. The questionnaire includes background data, occupational and health history. Results: The traffic policemen were determined as having lower lung function parameters; low FVC% predicted (89.6%) and low FEV1% predicted (94%) due to their nature of work and the environment. Coughing was present at the highest (33.6%) among them, whereas wheezing was found the least (15.7%) of the workers. Conclusions: Findings from this study, indicated that there is a development of respiratory diseases and deterioration of lung function among traffic policemen. These baseline data can serve as a reference to the top management of traffic police officers in order to develop an occupational safety and health guideline for police officers as they are not covered by Occupational Safety and Health Act (OSHA, Act 514 1994).
    Matched MeSH terms: Respiratory Function Tests
  20. Putri Anis Syahira MJ, Karmegam K, Nur Athirah Diyana MY, Irniza R, Shamsul Bahri MT, Vivien H, et al.
    Work, 2020;66(1):25-29.
    PMID: 32417810 DOI: 10.3233/WOR-203147
    BACKGROUND: Malaysian traffic policemen are constantly exposed to unhealthy air in the outdoor environment, which results in various health problems. This study investigates the relationship of the personal exposure level to PM2.5 and lung functions in traffic policemen in Kuala Lumpur and Johor Bahru.

    METHODS: A pulmonary function test using a spirometer was carried out to measure the lung function of the traffic policemen. The personal exposure level to PM2.5 was measured using a pump with a PVC filter and 5.0μm pore size. A questionnaire requesting the background data, such as age, height, and weight, was also used for testing lung function abnormalities.

    RESULTS: The PM2.5 personal exposure level was found to be significantly related to lung function (predicted FEV1 and predicted FVC) at p-value function deterioration among traffic policemen. These baseline data can serve as a reference for the top management of traffic police to aid in the development of occupational safety and health guidelines for police officers, as the traffic police are not covered by the Occupational Safety and Health Act (OSHA, Act 514 1994).

    Matched MeSH terms: Respiratory Function Tests*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links