Displaying publications 1 - 20 of 55 in total

Abstract:
Sort:
  1. Low YJ, Kittur MI, Andriyana A, Ang BC, Zainal Abidin NI
    J Mech Behav Biomed Mater, 2023 Apr;140:105723.
    PMID: 36821908 DOI: 10.1016/j.jmbbm.2023.105723
    Poly(glycolide-co-caprolactone) (PGCL) has become a novice to the bioresorbable suture owing to the synergistic properties taken from the homo-polyglycolide (PGA) and polycaprolactone (PCL) such as excellent bioresorption and flexibility. In addition to under conventional monotonic loading, the understanding of mechanical responses of PGCL copolymers under complex loading conditions such as cyclic and stress relaxation is crucial for its application as a surgical suture. Consequently, the present work focuses on evaluating the mechanical responses of PGCL sutures under monotonic, cyclic, and stress relaxation loading conditions. Under monotonic loading, the stress-strain behavior of the PGCL suture was found to be non-linear with noticeable strain-rate dependence. Under cyclic loading, inelastic responses including stress-softening, hysteresis and permanent set were observed. During cyclic loading, both stress-softening and hysteresis were found to increase with the maximum strain. In multi-step stress relaxation, the PGCL sutures were observed to exhibit a strong viscoelastic response. In an attempt to describe the relationship between the stress-relaxation and strain-induced crystallization (SIC) occurring during the loading and relaxation processes, a schematic illustration of the conformational change of polymer chains in PGCL sutures was proposed in this work. Results showed that SIC was dependent on the strain level as well as the loading and relaxation durations. The inelastic phenomena observed in PGCL sutures can be thus correlated to the combined effect of stress relaxation and SIC.
    Matched MeSH terms: Sutures
  2. Alnaqi A, Burhamah W, Al-Sultan AT, Taqi E
    World J Surg, 2023 Feb;47(2):448-454.
    PMID: 36316513 DOI: 10.1007/s00268-022-06788-3
    INTRODUCTION: Topical agents are sometimes applied to surgical wounds after closure; these may include antiseptics or antibiotics. Minimal research has been undertaken to investigate the effect of topical regimens on the tensile strength of suture materials.

    AIM: To investigate the effect of four commonly used wound care regimens on the tensile strength of suture materials.

    METHODS: The failure load of 9 different suture materials was tested using the Instron Electroplus E3000 tensile testing machine (Instron Corporation, Norwood, Massachusetts). Tensile strength was represented as the failure load, measured in Newtons (N), and defined as the maximal load that could be applied across the suture prior to failure. Each suture was tested dry and after immersion in one of 4 products for 7 days and tested on day 7. The immersion agents tested were: sodium chloride 0.9%, MicroSafe® (Sonoma Pharmaceuticals, Petaluma, CA), Aqueous Povidone-iodine 10% solution (Betadine-Mundipharma), and Fucidin ointment.

    RESULTS: Sodium chloride 0.9%, MicroSafe®, Aqueous Povidone-iodine 10%, and Fucidin seem to increase the failure load of most absorbable and non-absorbable sutures. However, the failure load of Polyglactin 910 suture (Surgilactin, coated, violet-Ethicon) is reduced by long-term exposure to either sodium chloride 0.9% or MicroSafe®, while the failure load of the Polydioxanone suture (PDS Plus-Ethicon) is reduced by long-term exposure to MicroSafe® only.

    CONCLUSION: In our experiment, the commonly used wound care products have been shown to alter the tensile strength of suture materials. Further human studies are required to ascertain the clinical validity and applicability of our findings.

    Matched MeSH terms: Sutures
  3. Hassan MA, Yunus RM, Khan S, Memon MA
    World J Surg, 2021 10;45(10):3080-3091.
    PMID: 34279690 DOI: 10.1007/s00268-021-06238-6
    BACKGROUND: With many different operative techniques in use to reduce the incidence of incisional hernias (IH) following a midline laparotomy, there is no consensus among the clinicians on the efficacy and safety of any particular repair technique. This meta-analysis compares the prophylactic onlay mesh repair (POMR) and primary suture repair (PSR) for the incidence of IH.

    METHODS: A meta-analysis and systematic review of MEDLINE, PubMed Central (via PubMed), Embase (via Ovid), SCOPUS, ScienceDirect, Google Scholar, SCI and Cochrane Library databases were undertaken. Seven randomized controlled trials assessing the outcomes of PSR and POMR were analyzed in accordance with the PRISMA statement. The risk of bias was assessed using the Rob2 tool.

    RESULTS: According to the pooled analysis, POMR significantly reduced the incidence of IH compared to the PSR (OR 5.82 [95% CI 2.69, 12.58] P 

    Matched MeSH terms: Sutures
  4. Win SS, Lasimbang HB, Lynn AUng SN, Yeap TB
    BMJ Case Rep, 2021 Aug 12;14(8).
    PMID: 34385222 DOI: 10.1136/bcr-2021-244226
    Obstetric haemorrhage is the leading cause of maternal death worldwide (27.1%) and more than 66% of its deaths were classified as postpartum haemorrhage (PPH). The most common cause of PPH is uterine atony. Obstetrician should be skillful in managing obstetric emergencies; especially pertaining to PPH. Application of the B-Lynch suture on an atonic uterus is one of the surgical options in PPH patients who wish to conserve the uterus and it has a very high success rate.We present a primigravida patient who developed massive primary PPH followed by disseminated intravascular coagulation, which was successfully managed with B-Lynch suture and bilateral internal iliac artery ligation. We described in detail regarding the management of massive PPH and application of these surgical procedures on the atonic uterus with an attempt to preserve the uterus and future fertility in this young patient.
    Matched MeSH terms: Sutures
  5. Khoo LS, Hsiao YC, Huang JJ, Chang FC, Wang YC, Liao YF, et al.
    J Craniofac Surg, 2021 5 4;32(8):2592-2596.
    PMID: 33935145 DOI: 10.1097/SCS.0000000000007704
    BACKGROUND: The main objective of contemporary orthognathic surgery is to correct dentofacial deformities. Nonetheless, many adjunct procedures to enhance the esthetic outcome in orthognathic surgical cases have been successfully incorporated to improve patient satisfaction. The authors report our preliminary experience of performing simultaneous orthognathic surgery with Asian double eyelid suture method blepharoplasty in the same surgical setting.

    METHOD: This case series report includes all 19 consecutive cases presenting to the Chang Gung Craniofacial Center for combined orthognathic surgery with Asian double eyelid suture method blepharoplasty. The double eyelid crease height was measured as the vertical line between the upper eyelid margin (eyelid lash) and the upper eyelid crease, observed at the mid-pupillary line with the eyes in primary gaze.

    RESULTS: There were no complications or relapse reported within this time period. There was significant improvement in the left and right mid-pupillary double eyelid crease height postsurgery. There were no statistically significant differences between the left and right mid-pupillary double eyelid crease heights after surgery indicating good eyelid crease height symmetry bilaterally was obtained.

    CONCLUSIONS: Orthognathic surgery combined with suture method blepharoplasty can be safely performed in the same surgical setting without inappropriate rise in costs or operating room time. This case series demonstrates that excellent esthetic results can be obtained in simultaneous bimaxillary orthognathic surgery with suture method Asian blepharoplasty.

    Matched MeSH terms: Sutures
  6. Lai LW, Roslani AC, Yan YW, Bhojwani KM, Jamaluddin MFH
    ANZ J Surg, 2021 05;91(5):896-901.
    PMID: 33522667 DOI: 10.1111/ans.16567
    BACKGROUND: Conventional mass closure uses suture-to-wound length ratio of 4:1 ('long stitch', LS). 'Short stitch' (SS) has a suture-to-wound length ratio of more than 4 and incorporates only the linea alba, which may reduce tension and pain. We compared the post-operative pain after laparotomy closure using LS and SS.

    METHODS: Patients undergoing elective midline laparotomy through standardized incisions in two tertiary hospitals from February 2017 to September 2018 were randomized to either LS or SS. The primary outcome was post-operative patient-controlled analgesia morphine usage at 24 h. Secondary outcomes were presence of surgical site infection and length of hospital stay (LOHS). Categorical variables were analysed using chi-squared analysis. Outcomes of study were tested for normal distribution. Skewed data were analysed using Mann-Whitney U-test.

    RESULTS: Eighty-six patients were recruited (42 SS and 44 LS). The median age was 66 (interquartile range (IQR) 15). Majority were males (62.8%) and Chinese (50%). The median incision length was 17 cm in both groups. The median patient-controlled analgesia morphine usage 24 h post-operatively did not differ significantly (SS 21 mg, IQR 28.3; LS 18.5 mg, IQR 33.8, P = 0.829). The median pain score at rest (SS 1, IQR 1; LS 1, IQR 2, P = 0.426) and movement (SS 3, IQR 1; LS 3, IQR 2, P = 0.307) did not differ significantly. LOHS was shorter in the SS group (SS 6, IQR 4; LS 8, IQR 5, P = 0.034). The rate of surgical site infection trended lower in the SS group with no statistical difference.

    CONCLUSION: There were no differences in post-operative pain between SS and LS but we found that there were shorter LOHS in SS arm as secondary outcome.

    Matched MeSH terms: Sutures
  7. Che Mohd Hilmi Che Mat1, Zulkiflee Salahuddin, Nik Azrizie Muhamed, Irfan Mohamad
    MyJurnal
    Osteomas occur in all parts of the temporal bone, including the mastoid, squamous, middle
    ear, styloid process, internal auditory canal and external auditory canal (EAC). The EAC has
    been reported to be the most common site, followed by the mastoid and squamous parts.
    Diagnosis is made based on history, clinical examination and radiological findings. Computed
    tomography reveals a pedunculated hyperdense mass that usually arises from the
    tympanosquamous suture. Surgical removal of EAC osteomas can be achieved using the
    endaural or postauricular approaches. It can be performed with a drill or osteotome, either
    endoscopically or by using microscopy. This report presents two patients with EAC osteomas
    who underwent excision under microscopy using the endaural approach. Surgery is the gold
    standard treatment, while close observation may be considered in asymptomatic patients.
    Matched MeSH terms: Sutures
  8. Kesu Belani L, Abdullah S, Harun MH, Narin Singh PSG, Sapuan J
    Cureus, 2020 Nov 19;12(11):e11564.
    PMID: 33364091 DOI: 10.7759/cureus.11564
    Monteggia fracture is commonly treated with open anatomical reduction and fixation of the ulna fracture. The radial head will be automatically reduced once anatomical fixation of the ulna is achieved. However, it is occasionally associated with an irreducible radial head dislocation requiring an open reduction and reconstruction of the torn annular ligament. We describe a case of traumatic Monteggia fracture which underwent initial plating, however post-operative radiograph denoted an irreducible radial head secondary to a ruptured annular ligament. We reconstructed the annular ligament with a synthetic graft sling around the radial neck with an anchor suture. The radial head was stable in all directions after annular ligament reconstruction. A two-year follow-up shows full range of motion of the elbow joint with osteolysis of the radial head, no other operative morbidity was observed.
    Matched MeSH terms: Sutures
  9. Rahman RA, Ghazali NM, Rahman NA, Pohchi A, Razak NHA
    J Craniofac Surg, 2020 Jun;31(4):1056-1062.
    PMID: 32176023 DOI: 10.1097/SCS.0000000000006297
    OBJECTIVES: This study aimed to determine the pattern of fractured zygoma, different treatment modalities, and complications of the treatment in our center. It also aimed to determine the association between the treatment modalities and complication of treatment, and association between number of fixation and complication.

    METHODOLOGY: A retrospective review was conducted from January 2008 until December 2011. All patients diagnosed with zygomatic complex fractured that met the inclusion and exclusion criteria were included in the study. Zingg's Classification was used in the study.

    RESULTS: The median age was 23.5. Type A was the most common fracture type made up 26.6%. About 90.8% of the injury was caused by road traffic accident. Forty-four patients were treated with open reduction and internal fixation and 4 patients were treated with close reduction only. Fifty patients were treated conservatively. Gillies approach in combination with fixation is the most common procedure accounted for 50%. Three-point fixation at infraorbital, maxillary buttress, frontozygomatic suture, and zygomatic arch was the most common site. However, there were no significant associations between the number of fixation and the occurrence of the complication (P = 0.307). About 29.2% in the treatment group and 66% in the conservative group had complications. About 35.7% of patients in treatment group had complications, while 66% had trismus in conservative group.

    CONCLUSION: There was a significant association between types of treatment and the occurrence of complication (P = 0.001). However, there were no significant association between number of fixation and the occurrence of complications (P = 0.307).

    Matched MeSH terms: Cranial Sutures
  10. Teo SH, Ng WM, Abd Rahim MR, Al-Fayyadh MZM, Ali MRM
    Indian J Orthop, 2020 Apr;54(2):168-173.
    PMID: 32257034 DOI: 10.1007/s43465-019-00024-2
    Introduction: This study aims to compare the biomechanical properties and ease of learning and tying of our novel knot (UM Knot) with other commonly used arthroscopic sliding knots.

    Materials and methods: The Duncan, HU, SMC, Pretzel, Nicky's and square knots were selected for comparisons with UM knot. All knots were prepared with size 2 HiFi® suture by a single experienced surgeon and tested with cyclic loading and load to failure tests. The ease of learning was assessed objectively by recording the time to learn the first correct knot and the total number of knots completed in 5 min by surgeons and trainees.

    Results: The UM knot average failure load is significantly superior to the HU knot (p 

    Matched MeSH terms: Sutures
  11. Adil MT, Aminian A, Bhasker AG, Rajan R, Corcelles R, Zerrweck C, et al.
    Obes Surg, 2020 02;30(2):483-492.
    PMID: 31677017 DOI: 10.1007/s11695-019-04195-7
    BACKGROUND: Sleeve Gastrectomy (SG) is the most commonly performed bariatric procedure worldwide. There is currently no scientific study aimed at understanding variations in practices concerning this procedure. The aim of this study was to study the global variations in perioperative practices concerning SG.

    METHODS: A 37-item questionnaire-based survey was conducted to capture the perioperative practices of the global community of bariatric surgeons. Data were analyzed using descriptive statistics.

    RESULTS: Response of 863 bariatric surgeons from 67 countries with a cumulative experience of 520,230 SGs were recorded. A total of 689 (80%) and 764 (89%) surgeons listed 13 absolute and relative contraindications, respectively. 65% (n = 559) surgeons perform routine preoperative endoscopy and 97% (n = 835) routinely use intraoperative orogastric tube for sizing the resection. A wide variation is observed in the diameter of the tube used. 73% (n = 627) surgeons start dividing the stomach at a distance of 3-5 cm from the pylorus, and 54% (n = 467) routinely use staple line reinforcement. Majority (65%, n = 565) of surgeons perform routine intraoperative leak test at the end of the procedure, while 25% (n = 218) surgeons perform a routine contrast study in the early postoperative period. Lifelong multivitamin/mineral, iron, vitamin D, calcium, and vitamin B12 supplementation is advocated by 66%, 29%, 40%, 38% and 44% surgeons, respectively.

    CONCLUSION: There is a considerable variation in the perioperative practices concerning SG. Data can help in identifying areas for future consensus building and more focussed studies.

    Matched MeSH terms: Sutures/statistics & numerical data
  12. Quek YS, Ling MJN, Hassan JB
    Int J Surg Case Rep, 2020;73:235-238.
    PMID: 32721883 DOI: 10.1016/j.ijscr.2020.07.028
    INTRODUCTION: Diastasis recti abdominis (DRA) is characterized by the separation of the two rectus abdominis muscle along the linea alba. A newly modified undermined suture rectus muscle technique at cesarean delivery is created with improved post-operative outcome.

    PRESENTATION OF CASE: A 30-year-old woman, who had a previous cesarean delivery, opted for another cesarean section (CS) during this pregnancy. She claimed that her tummy was lax after her first experience of CS even with regular exercise. A standard CS procedure was carried out along with the new modified undermined suture technique for rectus muscle re-approximation. Post-operatively, the pain score was 2/10 without any evidence of hematoma, seromas or infection and the patient ambulates well. The patient did not complain of any pain or complications upon follow up after 2 weeks and 2 months post-operation. She claims that her abdomen is firmer, flatter and more stable compared to her previous operation experience.

    DISCUSSION: This newly modified method prevents any defect or weakness on the anterior abdominal wall even if the rectus muscles fail to oppose itself during the healing process. It also mimics the function of the linea alba and avoid interrupting the contraction or injuring the muscle in order to avoid pain. Adhesion of the anterior uterine wall and the rectus sheath can be prevented by closure of the rectus muscle and burying the suture material within the muscle.

    CONCLUSION: The newly modified undermined suture rectus muscle technique at cesarean delivery has the potential to improved patient's post-operative satisfaction.

    Matched MeSH terms: Sutures
  13. Raymond DK Yeak, Nasir M Nizlan
    MyJurnal
    A 29-year-old man, who was a medical intern presented with history of recurrent shoulder dislocation. Radiographs
    and computed tomography imaging revealed a bony bankart lesion with glenoid bone loss of 25% with moderate
    Hill- Sachs lesion. Latarjet surgery was performed. At post-operative 8 months, the patient experienced pain and
    clicking in the left shoulder while performing cardiopulmonary resuscitation. At post-operative 1 year, magnetic resonance arthrography showed a united coracoid graft and intact posterior labrum. Left shoulder diagnostic arthroscopy and removal of Latarjet screws through a limited anterior deltopectoral approach were performed. The symptoms
    pain, clicking and instability sense was caused by either the prominent distal screw or the remnant suture material
    from the anchor which resulted in impingement of the infraspinatus muscle. We recommend the use of image intensifier to check on the position and length of the screw at the end of the surgery to avoid this complication
    Matched MeSH terms: Sutures
  14. Memon MA, Siddaiah-Subramanya M, Yunus RM, Memon B, Khan S
    Surg Laparosc Endosc Percutan Tech, 2019 Aug;29(4):221-232.
    PMID: 30855402 DOI: 10.1097/SLE.0000000000000655
    BACKGROUND: To explore the clinical outcomes, safety and effectiveness of suture cruroplasty versus mesh repair for large hiatal hernias (HHs) by an updated meta-analysis.

    MATERIAL AND METHODS: Randomized controlled trials evaluating the effects of these 2 treatment modalities were searched from PubMed and other electronic databases between January 1991 and July 2018. The outcome variables analyzed included operating time, complications, recurrence of HH or wrap migration, reoperation, hospital stay and quality of life.

    RESULTS: Five randomized controlled trials totaling 478 patients (suture=222, mesh=256) were analyzed. For reoperation variable, the odds ratio was significantly 3.26 times higher for the suture group. For recurrence of HH, the odds ratio for the suture group was nonsignificantly 1.65 times higher compared with the mesh group. Comparable effects were noted for all other variables.

    CONCLUSIONS: Mesh repair seems to be superior to suture cruroplasty for large HH repair. Therefore, the routine use of mesh may be advantageous in selected cases.

    Matched MeSH terms: Sutures
  15. Leong YC, Muhammad-Suhairi J
    Malays Orthop J, 2019 Jul;13(2):45-48.
    PMID: 31467652 DOI: 10.5704/MOJ.1907.009
    Treatment of chronic Rockwood's type V Acromioclavicular (AC) joint dislocation remains controversial. We describe a surgical technique to reduce and maintain AC joint using a combination of gracilis autograft with GraftMax™ button (Conmed Inc, Utica, NY). Graft was prepared using running whip stitch technique with No. 5 Hi-Fi high strength suture (ConMed Linvatec, Largo, FL). Our technique reduces intraoperative clavicular and coracoid tunnel fracture and restores anatomical coracoclavicular ligament. At sixth week and third month postoperatively, the patient demonstrated good clinical and radiographic outcome.
    Matched MeSH terms: Sutures
  16. Teoh LY, Chong SS, Hoh SY, Teoh MS, Ng KL
    Asian J Surg, 2019 May;42(5):634-640.
    PMID: 30446424 DOI: 10.1016/j.asjsur.2018.09.014
    OBJECTIVES: Monofilament sutures, both absorbable and non-absorbable, have been used for wound closure. Tissue adhesive has been used in closure of clean, low tension wounds. However, there have been very few published studies on the aesthetic outcomes in neck surgeries. The aim of this study is to compare the patients' and doctors' satisfaction scores in the aesthetic outcome between both methods of closure of thyroidectomy wounds using validated scoring systems.

    METHODS: A double-blinded randomised controlled trial comparing the aesthetic outcome between tissue adhesive and conventional suture was conducted among patients undergoing thyroid and parathyroid surgeries. Ninety-six patients were randomised into two treatment groups. Patients' wounds were scored by an independent observer using the SBSES score at 6 weeks postoperatively and observer component of the POSAS score at 3 months.

    RESULTS: Forty-nine patients were randomised to the tissue adhesive group while forty-seven patients received the conventional method. There was no statistical difference in the aesthetic outcome using the patient's scoring system between both arms, with a median score of 9 (p = 0.25, SD ± 6.5). The observer's satisfaction score using POSAS was also not statistically significant (median score of 14 (p = 0.77, SD ± 6.2)). No significance was found in the observer's median score using the SBSES scoring system either (score 3, p = 0.12, SD ± 1.3). However, there was significant reduction in the duration of closure using glue (4.42 mins vs 6.36 mins, p 

    Matched MeSH terms: Suture Techniques; Sutures*
  17. Lim JHC, Azman BAR, Othman BHR
    Zookeys, 2019;859:17-29.
    PMID: 31327920 DOI: 10.3897/zookeys.859.33284
    A new species of caprellid, Aciconulatinggiensis (Amphipoda, Senticaudata, Caprellidae) was discovered from Pulau Tinggi, Sultan Iskandar Marine Park (SIMP), South China Sea, Malaysia. The new Malaysian species can be distinguished from the other Aciconula species by the combination of the following characters: 1. the presence of a very small suture between head and pereonite 1; 2. antenna 1 flagellum with 4 articles; 3. inner lobe of lower lip unilobed; 4. gnathopod 2 palm of propodus with a large proximal projection (stretching from the proximal margin of the palm to nearly mid-way of palm); 5. pereopods 3-4 with 2 articles (article 1 subrectangular, article 2 conical or tapering at the tip with 1 plumose seta and 2 normal setae) and; 6. pereopod 5 covered with relatively dense and long setae. An updated identification key for the five known species in the genus, including information on the respective geographical distribution and habitat, is presented.
    Matched MeSH terms: Sutures
  18. Lai JH, Loo GH, Shuhaili MAB, Ritza Kosai N
    Int J Surg Case Rep, 2019;60:276-280.
    PMID: 31261047 DOI: 10.1016/j.ijscr.2019.06.045
    INTRODUCTION: Primary fascial closure can be a challenging step during a laparoscopic intraperitoneal onlay mesh (IPOM) repair for a ventral hernia.

    CASE PRESENTATION: We present here a novel technique of using intravenous (IV) cannula as an alternative to suture passer for fascial closure during laparoscopic IPOM repair for a 59-year-old patient with an incisional ventral hernia. The placement of non-absorbable sutures for fascial closure was done with the help of a 14 gauge IV cannula instead of a transfascial suture passer. The rest of the procedural steps were the same as a standard laparoscopic IPOM repair. The patient's post-operative recovery was uneventful.

    DISCUSSION: Primary fascial closure during a laparoscopic IPOM hernia repair can be done either by intracorporeal or extracorporeal techniques, using interrupted or continuous sutures. We propose a novel alternative to suture passer in primary fascial closure. IV cannulas are widely available in hospital settings. The advantage of using an IV cannula instead of a suture passer is that they are widely available. Its single-use also eliminates the risk of transmissible diseases, and as it has a smaller diameter than suture passer, it requires a lower insertion force for successful placement.

    CONCLUSION: An IV cannula may be used as a more economical alternative to a transfascial suture passer. This technique is easily reproducible and does not violate the principles of primary fascial defect closure in laparoscopic ventral hernia repair.

    Matched MeSH terms: Sutures
  19. Kapil-Mani KC, Niroula A
    Malays Orthop J, 2018 Jul;12(2):31-36.
    PMID: 30112126 DOI: 10.5704/MOJ.1807.006
    Introduction: The optimal surgical treatment for acromioclavicular joint (ACJ) injuries remains controversial. The modified Weaver-Dunn (WD) procedure is one of the frequently used techniques. Recently when it was compared with anatomical autogenous tendon graft reconstruction procedures, the results were inferior. However, these anatomical procedures are technically more demanding with small margin of error and they have tendency for postoperative pain because of extra donor site incision. Materials and Methods: Forty patients with type IV to VI ACJ dislocations were treated by modified WD procedure using non-absorbable synthetic suture passed through the base of coracoid process for augmentation of transferred coraco-acromial (CA) ligament. Functional outcome was assessed using the Oxford Shoulder Score, Nottingham Clavicular Score and Visual Analog Score (VAS) at the final follow-up after surgery. Results: The mean pre-operative Oxford Shoulder Score improved from 25.22±2.64 (range 20 to 30) to 44.75±1.99 (range 40 to 48) and mean pre-operative Nottingham Shoulder Score improved from 49.25±4.91 (range 39 to 58) to 87.27±4.39 (range 79 to 96) at last follow-up after surgery with p-value <0.001. Thirty-five (87.5%) patients had excellent outcomes, four (10%) patients had good outcomes and one (2.5%) patient had fair outcome. Thirty-eight (95%) patients had no pain while two (5%) had moderate pain based on VAS score. Conclusion: Modified Weaver-Dunn is a simple well established technique for grade IV to VI ACJ dislocation. We cannot consider this procedure as old and outdated on the argument that the long term functional outcomes are not suboptimal.
    Matched MeSH terms: Sutures
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links