Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Yunos MFAM, Manczak R, Guines C, Mansor AFM, Mak WC, Khan S, et al.
    Biosensors (Basel), 2021 Dec 03;11(12).
    PMID: 34940251 DOI: 10.3390/bios11120494
    Diabetes has become a major health problem in society. Invasive glucometers, although precise, only provide discrete measurements at specific times and are unsuitable for long-term monitoring due to the injuries caused on skin and the prohibitive cost of disposables. Remote, continuous, self-monitoring of blood sugar levels allows for active and better management of diabetics. In this work, we present a radio frequency (RF) sensor based on a stepped impedance resonator for remote blood glucose monitoring. When placed on top of a human hand, this RF interdigital sensor allows detection of variation in blood sugar levels by monitoring the changes in the dielectric constant of the material underneath. The designed stepped impedance resonator operates at 3.528 GHz with a Q factor of 1455. A microfluidic device structure that imitates the blood veins in the human hand was fabricated in PDMS to validate that the sensor can measure changes in glucose concentrations. To test the RF sensor, glucose solutions with concentrations ranging from 0 to 240 mg/dL were injected into the fluidic channels and placed underneath the RF sensor. The shifts in the resonance frequencies of the RF sensor were measured using a network analyzer via its S11 parameters. Based on the change in resonance frequencies, the sensitivity of the biosensor was found to be 264.2 kHz/mg·dL-1 and its LOD was calculated to be 29.89 mg/dL.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  2. Yee YC, Hashim R, Mohd Yahya AR, Bustami Y
    Sensors (Basel), 2019 May 31;19(11).
    PMID: 31159318 DOI: 10.3390/s19112511
    Glucose oxidase (EC 1.1.3.4) sensors that have been developed and widely used for glucose monitoring have generally relied on electrochemical principle. In this study, the potential use of colorimetric method for glucose detection utilizing glucose oxidase-magnetic cellulose nanocrystals (CNCs) is explored. Magnetic cellulose nanocrystals (magnetic CNCs) were fabricated using iron oxide nanoparticles (IONPs) and cellulose nanocrystals (CNCs) via electrostatic self-assembly technique. Glucose oxidase was successfully immobilized on magnetic CNCs using carbodiimide-coupling reaction. About 33% of GOx was successfully attached on magnetic CNCs, and the affinity of GOx-magnetic CNCs to glucose molecules was slightly higher than free enzymes. Furthermore, immobilization does not affect the specificity of GOx-magnetic CNCs towards glucose and can detect glucose from 0.25 mM to 2.5 mM. Apart from that, GOx-magnetic CNCs stored at 4 °C for 4 weeks retained 70% of its initial activity and can be recycled for at least ten consecutive cycles.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  3. Wong JS, Rahimah N
    Med J Malaysia, 2004 Aug;59(3):411-7.
    PMID: 15727390 MyJurnal
    Achieving glycaemic goals in diabetics has always been a problem, especially in a developing country with inadequate facilities such as in Sarawak in Malaysia. There are no reported studies on the control of diabetes mellitus in a diabetic clinic in the primary health care setting in Sarawak. This paper describes the profile of 1031 patients treated in Klinik Kesihatan Tanah Puteh Health Centre. The mean age was 59 years, the mean BMI 27 kg/m2. There was a female preponderance and mainly type-2 diabetes. Mean HbA1c was 7.4%. Glycaemic control was optimal in 28% (HbA1c <6.5%), fair in 34% (HbA1c 6.5-7.5%) and poor in 38% (HbA1c >7.5%). Reasonable glycaemic control can be achieved in the primary health care setting in Sarawak.
    Study site: Klinik Kesihatan Tanah Puteh, Sarawak, Malaysia
    Matched MeSH terms: Blood Glucose Self-Monitoring
  4. Tong WT, Vethakkan SR, Ng CJ
    BMJ Open, 2015 Jan 29;5(1):e006407.
    PMID: 25633285 DOI: 10.1136/bmjopen-2014-006407
    OBJECTIVE: To explore factors influencing poor glycaemic control in people with type 2 diabetes using insulin.
    RESEARCH DESIGN: A qualitative method comprising in-depth individual interviews. A semistructured interview guide was used. The interviews were audiorecorded, transcribed verbatim and analysed using a thematic approach.
    PARTICIPANTS: Seventeen people with type 2 diabetes using insulin with glycated haemoglobin (HbA1c) ≥9% for >1 year.
    SETTING: The Primary Care Clinic and Diabetes Clinic in the University of Malaya Medical Centre (UMMC), Malaysia.
    RESULTS: Data analysis uncovered four themes: lifestyle challenges in adhering to medical recommendations; psychosocial and emotional hurdles; treatment-related factors; lack of knowledge about and self-efficacy in diabetes self-care.
    CONCLUSIONS: Factors that explain the poor glycaemic control in people with type 2 diabetes using insulin were identified. Healthcare providers could use these findings to address patients' concerns during consultations and help to improve glycaemic control.
    Study site: Primary Care Clinic and Diabetes Clinic, University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Blood Glucose Self-Monitoring
  5. Teoh ST, Hussain S, Hong JYH
    J ASEAN Fed Endocr Soc, 2022;37(2):49-59.
    PMID: 36578892 DOI: 10.15605/jafes.037.02.08
    OBJECTIVES: This study described and compared glycaemic changes with the use of the following Continuous Glucose Monitoring (CGM) metrics: time in range, time in hyperglycaemia and time in hypoglycaemia from retrospective CGM data among children and adolescents with Type 1 Diabetes Mellitus (T1DM), before and during Ramadan to better understand the impact of fasting during this season.

    METHODOLOGY: This study was conducted in 2 tertiary centres: Hospital Putrajaya (HPJ) and Hospital Universiti Sains Malaysia (HUSM) from February to May 2020. Muslim T1DM patients between ages 8 to18 who intended to fast during Ramadan were given Ramadan-focused education. CGM iPro2® (Medtronic) was used before and during Ramadan, complemented by finger-prick glucose monitoring or self-monitoring of blood glucose (SMBG).

    RESULTS: Of the 32 patients, only 24 (12 female) were analysed. Mean age was 13.6 ± 3.1 years old, mean HbAlc was 9.6 ± 1.9% and mean duration of illness was 5.4 ± 3.4 years. Majority (91.7%) were on multiple dose injections (MDI) while only 8.3% were on continuous subcutaneous insulin infusion (CSII). All fasted in Ramadan without acute complications. Retrospective CGM analysis revealed similar results in time in range (TIR), time in hyperglycaemia and time in hypoglycaemia before and during Ramadan, indicating no increased hypoglycaemic or hyperglycaemic events related to fasting. Glycaemic variability before Ramadan as measured by the LBGI, HBGI and MAG, were similar to values during Ramadan.

    CONCLUSION: Ramadan fasting among T1DM children and adolescents, by itself, is not associated with short-term glycaemic deterioration. T1DM youths can fast safely in Ramadan with the provision of focused education and regular SMBG.

    Matched MeSH terms: Blood Glucose Self-Monitoring/methods
  6. Tan MY, Magarey JM, Chee SS, Lee LF, Tan MH
    Health Educ Res, 2011 Oct;26(5):896-907.
    PMID: 21715653 DOI: 10.1093/her/cyr047
    We assessed the effectiveness of a brief structured diabetes education programme based on the concept of self-efficacy on self-care and glycaemic control using single-blind study design. One hundred and sixty-four participants with poorly controlled diabetes from two settings were randomized using computer-generated list into control (n = 82) and intervention (n = 82) groups, of which 151 completed the study. Monthly interventions over 12 weeks addressed the self-care practices of diet, physical activity, medication adherence and self-monitoring of blood glucose (SMBG). These self-care practices were assessed at Weeks 0 and 12 using pre- and post-questionnaires in both groups together with glycated haemoglobin A1c (HbA1c) and diabetes knowledge. In the intention-to-treat analysis (n = 164), the intervention group improved their SMBG (P = <0.001), physical activity (P = 0.001), HbA1c (P = 0.03), diabetes knowledge (P = <0.001) and medication adherence. At Week 12, HbA1c difference adjusted for SMBG frequency, medication adherence and weight change remained significant (P = 0.03) compared with control group. For within group comparisons, diabetes knowledge (P = <0.001), HbA1c level (P = <0.001), SMBG (P = <0.001) and medication adherence (P = 0.008) improved from baseline in the intervention group. In the control group, only diabetes knowledge improved (P = <0.001). These findings can contribute to the development of self-management diabetes education in Malaysia.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  7. Tan MY, Magarey J
    Patient Educ Couns, 2008 Aug;72(2):252-67.
    PMID: 18467068 DOI: 10.1016/j.pec.2008.03.017
    OBJECTIVE: To investigate the self-care practices of Malaysian adults with diabetes and sub-optimal glycaemic control.
    METHODS: Using a one-to-one interviewing approach, data were collected from 126 diabetic adults from four settings. A 75-item questionnaire was used to assess diabetes-related knowledge and self-care practices regarding, diet, medication, physical activity and self-monitoring of blood glucose (SMBG).
    RESULTS: Most subjects had received advice on the importance of self-care in the management of their diabetes and recognised its importance. Sixty-seven subjects (53%) scored below 50% in their diabetes-related knowledge. Subjects who consumed more meals per day (80%), or who did not include their regular sweetened food intakes in their daily meal plan (80%), or who were inactive in daily life (54%), had higher mean fasting blood glucose levels (p=0.04). Subjects with medication non-adherence (46%) also tended to have higher fasting blood glucose levels. Only 15% of the subjects practiced SMBG. Predictors of knowledge deficit and poor self-care were low level of education (p = <0.01), older subjects (p=0.04) and Type 2 diabetes subjects on oral anti-hyperglycaemic medication (p = <0.01).
    CONCLUSION: There were diabetes-related knowledge deficits and inadequate self-care practices among the majority of diabetic patients with sub-optimal glycaemic control.
    PRACTICE IMPLICATIONS: This study should contribute to the development of effective education strategies to promote health for adults with sub-optimal diabetes control.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  8. Tamrin, K.F., Adilah, A.N., Hamdi, M.M., Jong, R.P.
    MyJurnal
    A glucose meter (or glucometer) is a medical device for determining the approximate concentration of glucose in the
    blood by pricking a finger to draw blood sample using a sharp needle. However, diabetic patient has quite slow level in
    wound healing process which causes their fingers constantly in a state of wounded and exposed to bacteria. More
    importantly, two main factors for the weakness of invasive technique is a painful process and cost often because constant
    monitoring of glucose level is very expensive. The main objective of this research is to design and develop a non-invasive
    optical measuring technique to measure body glucose level automatically and painlessly using a laser pointer and a
    smartphone. Images captured by the smartphone is analysed using a Matlab software to determine the refractive index of
    the urine sample. Calibration of the system is performed by correlating the results with that of the glucometer. Both
    results compare well with R-squared value of 92.9%. The system can be potentially used for remote health and patient
    monitoring.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  9. Sulaiman, I.M., HS, Lee, Balan, S., Jaafar, M.Z.
    Medicine & Health, 2006;1(1):20-24.
    MyJurnal
    Fifty Non Insulin Dependent Diabetes Mellitus (NIDDM) patients undergoing surgery under epidural anaesthesia were studied. All patients received dextrose 5% infusion at 100 ml/hr from the period of fasting until upon arrival to the operation room. Patients were randomly divided into two groups. Patients in Group 1 (n=25) received normal saline while patients in Group 2 (n=25) were given Ringer’s lactate. Both groups received their infusion throughout the operative period up to four hours postoperatively. Blood glucose level was measured at baseline, 45 minutes intra operatively and postoperatively at 30 minutes and four hours by using a glucometer. Patients in Group 2 has a larger mean increase in blood glucose level of 1.5 mmol/L between 4 hours postoperatively and baseline compared to 0.96 mmol/L in Group 1. However, this was not statistically significant. There was no difference in the increase of mean glucose level at 30 minutes when compared to baseline. There was a significant increase in mean blood glucose level in both groups in the postoperative period when compared to baseline. This study demonstrated that patients with NIDDM receiving Ringer’s lactate has a larger increase in mean blood glucose level compared to those receiving normal saline, but the magnitude is not statistically significant.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  10. Scott EM, Bilous RW, Kautzky-Willer A
    Diabetes Technol Ther, 2018 03;20(3):180-188.
    PMID: 29470094 DOI: 10.1089/dia.2017.0386
    BACKGROUND: Accuracy of the FreeStyle Libre™ Flash Glucose Monitoring System has not been evaluated in pregnant women with diabetes. The aim of this study was to determine accuracy (compared to self-monitoring of blood glucose [SMBG]), clinical safety, and acceptability of the FreeStyle Libre System when used at home by this population.

    MATERIALS AND METHODS: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day).

    RESULTS: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events.

    CONCLUSIONS: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.

    Matched MeSH terms: Blood Glucose Self-Monitoring/adverse effects*
  11. Rama Chandran S, Tay WL, Lye WK, Lim LL, Ratnasingam J, Tan ATB, et al.
    Diabetes Technol Ther, 2018 05;20(5):353-362.
    PMID: 29688755 DOI: 10.1089/dia.2017.0388
    BACKGROUND: Hypoglycemia is the major impediment to therapy intensification in diabetes. Although higher individualized HbA1c targets are perceived to reduce the risk of hypoglycemia in those at risk of hypoglycemia, HbA1c itself is a poor predictor of hypoglycemia. We assessed the use of glycemic variability (GV) and glycemic indices as independent predictors of hypoglycemia.

    METHODS: A retrospective observational study of 60 type 1 and 100 type 2 diabetes subjects. All underwent professional continuous glucose monitoring (CGM) for 3-6 days and recorded self-monitored blood glucose (SMBG). Indices were calculated from both CGM and SMBG. Statistical analyses included regression and area under receiver operator curve (AUC) analyses.

    RESULTS: Hypoglycemia frequency (53.3% vs. 24%, P Blood Glucose Index (LBGI)CGM, Glycemic Risk Assessment Diabetes Equation (GRADE)HypoglycemiaCGM, and Hypoglycemia IndexCGM predicted hypoglycemia well. %CVCGM and %CVSMBG consistently remained a robust discriminator of hypoglycemia in type 1 diabetes (AUC 0.88). In type 2 diabetes, a combination of HbA1c and %CVSMBG or LBGISMBG could help discriminate hypoglycemia.

    CONCLUSION: Assessment of glycemia should go beyond HbA1c and incorporate measures of GV and glycemic indices. %CVSMBG in type 1 diabetes and LBGISMBG or a combination of HbA1c and %CVSMBG in type 2 diabetes discriminated hypoglycemia well. In defining hypoglycemia risk using GV and glycemic indices, diabetes subtypes and data source (CGM vs. SMBG) must be considered.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  12. Rama Chandran S, A Vigersky R, Thomas A, Lim LL, Ratnasingam J, Tan A, et al.
    Diabetes Technol Ther, 2020 02;22(2):103-111.
    PMID: 31502876 DOI: 10.1089/dia.2019.0277
    Background:
    Complex changes of glycemia that occur in diabetes are not fully captured by any single measure. The Comprehensive Glucose Pentagon (CGP) measures multiple aspects of glycemia to generate the prognostic glycemic risk (PGR), which constitutes the relative risk of hypoglycemia combined with long-term complications. We compare the components of CGP and PGR across type 1 and type 2 diabetes.
    Methods:
    Participants: n = 60 type 1 and n = 100 type 2 who underwent continuous glucose monitoring (CGM). Mean glucose, coefficient of variation (%CV), intensity of hypoglycemia (INThypo), intensity of hyperglycemia (INThyper), time out-of-range (TOR <3.9 and >10 mmol/L), and PGR were calculated. PGR (median, interquartile ranges [IQR]) for diabetes types, and HbA1c classes were compared.
    Results:
    While HbA1c was lower in type 1 (type 1 vs. type 2: 8.0 ± 1.6 vs. 8.6 ± 1.7, P = 0.02), CGM-derived mean glucoses were similar across both groups (P > 0.05). TOR, %CV, INThypo, and INThyper were all higher in type 1 [type 1 vs. type 2: 665 (500, 863) vs. 535 (284, 823) min/day; 39% (33, 46) vs. 29% (24, 34); 905 (205, 2951) vs. 18 (0, 349) mg/dL × min2; 42,906 (23,482, 82,120) vs. 30,166 (10,276, 57,183) mg/dL × min2, respectively, all P 
    Matched MeSH terms: Blood Glucose Self-Monitoring
  13. Park SW, Bebakar WM, Hernandez PG, Macura S, Hersløv ML, de la Rosa R
    Diabet Med, 2017 02;34(2):174-179.
    PMID: 26773557 DOI: 10.1111/dme.13069
    AIMS: To compare the efficacy and safety of two titration algorithms for insulin degludec/insulin aspart (IDegAsp) administered once daily with metformin in participants with insulin-naïve Type 2 diabetes mellitus.

    METHODS: This open-label, parallel-group, 26-week, multicentre, treat-to-target trial, randomly allocated participants (1:1) to two titration arms. The Simple algorithm titrated IDegAsp twice weekly based on a single pre-breakfast self-monitored plasma glucose (SMPG) measurement. The Stepwise algorithm titrated IDegAsp once weekly based on the lowest of three consecutive pre-breakfast SMPG measurements. In both groups, IDegAsp once daily was titrated to pre-breakfast plasma glucose values of 4.0-5.0 mmol/l. Primary endpoint was change from baseline in HbA1c (%) after 26 weeks.

    RESULTS: Change in HbA1c at Week 26 was IDegAspSimple -14.6 mmol/mol (-1.3%) (to 52.4 mmol/mol; 6.9%) and IDegAspStepwise -11.9 mmol/mol (-1.1%) (to 54.7 mmol/mol; 7.2%). The estimated between-group treatment difference was -1.97 mmol/mol [95% confidence interval (CI) -4.1, 0.2] (-0.2%, 95% CI -0.4, 0.02), confirming the non-inferiority of IDegAspSimple to IDegAspStepwise (non-inferiority limit of ≤ 0.4%). Mean reduction in fasting plasma glucose and 8-point SMPG profiles were similar between groups. Rates of confirmed hypoglycaemia were lower for IDegAspStepwise [2.1 per patient years of exposure (PYE)] vs. IDegAspSimple (3.3 PYE) (estimated rate ratio IDegAspSimple /IDegAspStepwise 1.8; 95% CI 1.1, 2.9). Nocturnal hypoglycaemia rates were similar between groups. No severe hypoglycaemic events were reported.

    CONCLUSIONS: In participants with insulin-naïve Type 2 diabetes mellitus, the IDegAspSimple titration algorithm improved HbA1c levels as effectively as a Stepwise titration algorithm. Hypoglycaemia rates were lower in the Stepwise arm.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  14. Paramasivam SS, Chinna K, Singh AKK, Ratnasingam J, Ibrahim L, Lim LL, et al.
    Diabet Med, 2018 08;35(8):1118-1129.
    PMID: 29663517 DOI: 10.1111/dme.13649
    AIMS: To determine if therapeutic, retrospective continuous glucose monitoring (CGM) improves HbA1c with less hypoglycaemia in women with insulin-treated gestational diabetes mellitus (GDM).

    METHODS: This prospective, randomized controlled, open-label trial evaluated 50 women with insulin-treated GDM randomized to either retrospective CGM (6-day sensor) at 28, 32 and 36 weeks' gestation (Group 1, CGM, n = 25) or usual antenatal care without CGM (Group 2, control, n = 25). All women performed seven-point capillary blood glucose (CBG) profiles at least 3 days per week and recorded hypoglycaemic events (symptomatic and asymptomatic CBG

    Matched MeSH terms: Blood Glucose Self-Monitoring/instrumentation; Blood Glucose Self-Monitoring/methods
  15. Nor Azlin MI, Adam R, Sufian SS, Wahab NA, Mustafa N, Kamaruddin NA, et al.
    J Obstet Gynaecol Res, 2011 Feb;37(2):132-7.
    PMID: 21159037 DOI: 10.1111/j.1447-0756.2010.01330.x
    AIM: To evaluate the safety and tolerability of once or twice daily neutral protamine hagedorn (NPH) insulin in fasting pregnant diabetics during Ramadan.
    METHODS: This was a prospective cohort study conducted during Ramadan 2006 and 2007. Twenty four pregnant diabetic women were given NPH insulin once at 5 pm or twice daily at 5 pm and 5 am. Demographic data, blood glucose control, insulin requirement, days of fasting and hypoglycemic episodes were analyzed.
    RESULTS: Most women were parity 1 (37.5%) in their second trimester (54.2%) and worked during the daytime (87.5%). Fourteen women (58.3%) had gestational diabetes mellitus, nine women (37.5%) had type 2 and one (4.2%) had type 1 diabetes mellitus. There were significant reductions in mean fasting blood glucose (6.16 mmol/L versus 5.34 mmol/L, P = 0.001), glycosylated hemoglobin (HbA1c) (6.70% ± 0.91 versus 6.64% ± 0.96, P = 0.001) and serum fructosamine (232.4 mmol/L ± 24.0 versus 217.0 mmol/L ± 24.3, P = 0.001) after Ramadan compared to before Ramadan. Throughout the four weeks of Ramadan, home blood glucose monitoring showed a reducing trend and was within the acceptable limits. Insulin requirement was increased from the first to the fourth week with a reduction in insulin dose noted after (38.5 U/day) compared to before the start of Ramadan (40 U/day). Most women (79.2%) were able to fast for more than 15 days without any hypoglycemia or fetal demise.
    CONCLUSION: Once or twice daily NPH insulin is a safe and tolerable option for pregnant diabetics who wish to fast during Ramadan.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  16. Ng SM, Malene IV, Nguyen TK, Le K, Lim YXL, Lek N, et al.
    BMC Endocr Disord, 2023 Nov 16;23(1):249.
    PMID: 37974071 DOI: 10.1186/s12902-023-01501-4
    BACKGROUND: There is minimal data of health outcomes for Type 1 Diabetes (T1D) in Southeast Asia (SEA) where government funding of insulin and blood glucose monitoring either do not exist or is limited. The full impact of Covid-19 pandemic on the national economies of SEA remain unknown. In the midst of the pandemic, in 2021, HelloType1 was developed by Action4Diabetes (A4D), a non-government organisation charity in collaboration with Southeast Asia local healthcare professionals as an innovative digital educational resource platform of T1D in local languages. HelloType1 was launched in Cambodia, Vietnam, Thailand and Malaysia in 2021 to 2022 with Memorandums of Understandings (MOUs) signed between A4D and each country. Internet data analytics were undertaken between the 1st of January 2022 to 31st of December 2022.

    AIMS: The aims of this study were to explore the usability and internet data analytics of the HelloType1 online educational platform within each country.

    METHODS: The data analytics were extracted Google analytics that tracks data from the website hellotype1.com and Facebook analytics associated with the website.

    RESULTS: There was a 147% increase in the number of HelloType1 users between the first 6 months versus the latter 6 months in 2022 and a 15% increase in the number of pages visited were noted. The majority of traffic source were coming from organic searches with a significant increase of 80% growth in 2022.

    CONCLUSIONS: The results of the analytics provide important insights on how an innovative diabetes digital educational resource in local languages may be optimally delivered in low-middle income countries with limited resources.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  17. Ng D, Noor NM, Yong SL
    J ASEAN Fed Endocr Soc, 2019;34(1):29-35.
    PMID: 33442134 DOI: 10.15605/jafes.034.01.06
    Objectives: To determine the prevalence of hypoglycaemia using continuous glucose monitoring system (CGMS) among insulin-treated pregnant women with diabetes whose glycosylated haemoglobin (HbA1c) were <6.0% and identify the risk factors associated with hypoglycaemia occurrence.

    Methodology: We conducted a cross-sectional study using 6-days CGMS to detect the prevalence of hypoglycaemia in 31 insulin-treated pregnant women with diabetes who achieved HbA1c <6.0%. Patients were required to log-keep their self-monitoring blood glucose (SMBG) readings and hypoglycaemia events.

    Results: Eight women experienced confirmed hypoglycaemia with additional seven experienced relative hypoglycaemia, giving rise to prevalence rate of 45.2% (one had both confirmed and relative hypoglycaemia). Nine relative hypoglycaemia and 17 confirmed hypoglycaemic events were recorded. Sixteen (94%) out of 17 confirmed hypoglycaemia events recorded by CGMS were asymptomatic and were missed despite performing regular SMBG. Nocturnal hypoglycaemia events were recorded in seven women. Univariable analysis did not identify any association between conventional risk factors and hypoglycaemia events in our cohort.

    Conclusion: Insulin-treated pregnant women with diabetes who achieved HbA1c <6.0% were associated with high prevalence of hypoglycaemia. Asymptomatic hypoglycaemia is common in our cohort and frequently missed despite regular SMBG. Present study did not identify any association between conventional risk factors and hypoglycaemia events in our cohort.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  18. Nawawi H, Sazali BS, Kamaruzaman BH, Yazid TN, Jemain AA, Ismail F, et al.
    Ann. Clin. Biochem., 2001 Nov;38(Pt 6):676-83.
    PMID: 11732650
    The effect of ambient temperature on the analytical and clinical performance of a glucose meter was examined. A total of 114 venous whole blood samples were analysed for glucose by a reference method, and by a glucose meter at 21-22 degrees C, room temperatures, 26-27 degrees C and 33-34 degrees C. Glucose meter readings at each temperature were compared with the reference values and evaluated by analysis of variance, Spearman's correlation, the percentage of glucose meter readings within +/- 10% of the reference value and error grid analysis. Analysis of covariance was used to determine the effect of temperature on glucose meter readings. There were no significant differences in the glucose meter readings and in accuracy of the meter readings between different temperatures. Temperature was not a significant independent determinant of the glucose meter readings. For each glucose concentration, the precision of the meter and clinical performance were comparable between the different temperatures. In conclusion, ambient temperature does not affect the accuracy, precision and clinical performance of the Omnitest Sensor.
    Matched MeSH terms: Blood Glucose Self-Monitoring/instrumentation*; Blood Glucose Self-Monitoring/standards; Blood Glucose Self-Monitoring/statistics & numerical data
  19. Muhammed Elamin S, Muhamad Arshad NF, Md Redzuan A, Abdul Aziz SA, Hong J, Chua XY, et al.
    BMJ Open, 2024 Apr 02;14(4):e079606.
    PMID: 38569693 DOI: 10.1136/bmjopen-2023-079606
    OBJECTIVE: The objective of this study is to explore the information needs related to insulin therapy in children and adolescents with type 1 diabetes mellitus (T1DM) from the children's perspectives as well as their caregivers.

    DESIGN: Qualitative study; semistructured interviews. To identify emerging themes relating to information needs, open coding and thematic analysis were employed.

    SETTING: Participants were recruited from a tertiary care children's hospital in Kuala Lumpur, Malaysia and a specialist hospital in Riyadh, Saudi Arabia.

    PARTICIPANTS: Thirty one children with a mean age of 11.5 years (SD=1.9) and their caregivers were interviewed. Seventeen participants were from Malaysia and 14 were from Saudi Arabia.

    RESULTS: Four themes of information emerged from the interviews, including information related to (1) hypoglycaemia and hyperglycaemia, (2) insulin therapy, (3) injection technique and (4) other information needs pertaining to continuous glucose monitoring, access to peer groups and future advances in insulin therapy.

    CONCLUSION: This study provided valuable insights into the information needs related to T1DM and insulin therapy among children and adolescents with T1DM that should be considered by stakeholders in the development of age-appropriate education materials. Such materials will assist children and adolescents to better manage their life-long T1DM condition from adolescence until adulthood.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  20. Moy FM, Ray A, Buckley BS, West HM
    Cochrane Database Syst Rev, 2017 Jun 11;6(6):CD009613.
    PMID: 28602020 DOI: 10.1002/14651858.CD009613.pub3
    BACKGROUND: Self-monitoring of blood glucose (SMBG) is recommended as a key component of the management plan for diabetes therapy during pregnancy. No existing systematic reviews consider the benefits/effectiveness of various techniques of blood glucose monitoring on maternal and infant outcomes among pregnant women with pre-existing diabetes. The effectiveness of the various monitoring techniques is unclear.

    OBJECTIVES: To compare techniques of blood glucose monitoring and their impact on maternal and infant outcomes among pregnant women with pre-existing diabetes.

    SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 November 2016), searched reference lists of retrieved studies and contacted trial authors.

    SELECTION CRITERIA: Randomised controlled trials (RCTs) and quasi-RCTs comparing techniques of blood glucose monitoring including SMBG, continuous glucose monitoring (CGM) or clinic monitoring among pregnant women with pre-existing diabetes mellitus (type 1 or type 2). Trials investigating timing and frequency of monitoring were also included. RCTs using a cluster-randomised design were eligible for inclusion but none were identified.

    DATA COLLECTION AND ANALYSIS: Two review authors independently assessed study eligibility, extracted data and assessed the risk of bias of included studies. Data were checked for accuracy. The quality of the evidence was assessed using the GRADE approach.

    MAIN RESULTS: This review update includes at total of 10 trials (538) women (468 women with type 1 diabetes and 70 women with type 2 diabetes). The trials took place in Europe and the USA. Five of the 10 included studies were at moderate risk of bias, four studies were at low to moderate risk of bias, and one study was at high risk of bias. The trials are too small to show differences in important outcomes such as macrosomia, preterm birth, miscarriage or death of baby. Almost all the reported GRADE outcomes were assessed as being very low-quality evidence. This was due to design limitations in the studies, wide confidence intervals, small sample sizes, and few events. In addition, there was high heterogeneity for some outcomes.Various methods of glucose monitoring were compared in the trials. Neither pooled analyses nor individual trial analyses showed any clear advantages of one monitoring technique over another for primary and secondary outcomes. Many important outcomes were not reported.1. Self-monitoring versus standard care (two studies, 43 women): there was no clear difference for caesarean section (risk ratio (RR) 0.78, 95% confidence interval (CI) 0.40 to 1.49; one study, 28 women) or glycaemic control (both very low-quality), and not enough evidence to assess perinatal mortality and neonatal mortality and morbidity composite. Hypertensive disorders of pregnancy, large-for-gestational age, neurosensory disability, and preterm birth were not reported in either study.2. Self-monitoring versus hospitalisation (one study, 100 women): there was no clear difference for hypertensive disorders of pregnancy (pre-eclampsia and hypertension) (RR 4.26, 95% CI 0.52 to 35.16; very low-quality: RR 0.43, 95% CI 0.08 to 2.22; very low-quality). There was no clear difference in caesarean section or preterm birth less than 37 weeks' gestation (both very low quality), and the sample size was too small to assess perinatal mortality (very low-quality). Large-for-gestational age, mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.3. Pre-prandial versus post-prandial glucose monitoring (one study, 61 women): there was no clear difference between groups for caesarean section (RR 1.45, 95% CI 0.92 to 2.28; very low-quality), large-for-gestational age (RR 1.16, 95% CI 0.73 to 1.85; very low-quality) or glycaemic control (very low-quality). The results for hypertensive disorders of pregnancy: pre-eclampsia and perinatal mortality are not meaningful because these outcomes were too rare to show differences in a small sample (all very low-quality). The study did not report the outcomes mortality or morbidity composite, neurosensory disability or preterm birth.4. Automated telemedicine monitoring versus conventional system (three studies, 84 women): there was no clear difference for caesarean section (RR 0.96, 95% CI 0.62 to 1.48; one study, 32 women; very low-quality), and mortality or morbidity composite in the one study that reported these outcomes. There were no clear differences for glycaemic control (very low-quality). No studies reported hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), neurosensory disability or preterm birth.5.CGM versus intermittent monitoring (two studies, 225 women): there was no clear difference for pre-eclampsia (RR 1.37, 95% CI 0.52 to 3.59; low-quality), caesarean section (average RR 1.00, 95% CI 0.65 to 1.54; I² = 62%; very low-quality) and large-for-gestational age (average RR 0.89, 95% CI 0.41 to 1.92; I² = 82%; very low-quality). Glycaemic control indicated by mean maternal HbA1c was lower for women in the continuous monitoring group (mean difference (MD) -0.60 %, 95% CI -0.91 to -0.29; one study, 71 women; moderate-quality). There was not enough evidence to assess perinatal mortality and there were no clear differences for preterm birth less than 37 weeks' gestation (low-quality). Mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.6. Constant CGM versus intermittent CGM (one study, 25 women): there was no clear difference between groups for caesarean section (RR 0.77, 95% CI 0.33 to 1.79; very low-quality), glycaemic control (mean blood glucose in the 3rd trimester) (MD -0.14 mmol/L, 95% CI -2.00 to 1.72; very low-quality) or preterm birth less than 37 weeks' gestation (RR 1.08, 95% CI 0.08 to 15.46; very low-quality). Other primary (hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), mortality or morbidity composite, and neurosensory disability) or GRADE outcomes (preterm birth less than 34 weeks' gestation) were not reported.

    AUTHORS' CONCLUSIONS: This review found no evidence that any glucose monitoring technique is superior to any other technique among pregnant women with pre-existing type 1 or type 2 diabetes. The evidence base for the effectiveness of monitoring techniques is weak and additional evidence from large well-designed randomised trials is required to inform choices of glucose monitoring techniques.

    Matched MeSH terms: Blood Glucose Self-Monitoring/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links