Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Gillani SW, Sari YO, Sulaiman SA, Baig MR
    Curr Diabetes Rev, 2014;10(5):311-26.
    PMID: 25316148 DOI: 10.2174/1573399810666141015095004
    Our study objective was to evaluate glucose tolerance and effecting factors among diabetes patients' with home care program (PHCP) in Malaysian community. A 24-week longitudinal quasi-experimental -single blind - pre/post-test study design was used to assess the effectiveness of a diabetes education program to enhance self-care practices. An attrition rate of 25% implied longitudinal design of the study in the calculation of sample size. Hence the sample size of the study was 106 subjects (53 cases and 53 focus group). The level of significance was set at 0.05. Ethical clearance had been made prior to conducting this study. Of the 109 subjects who met the study-entry criteria, 3 subjects declined to participate due to lack of time and interest. No significant parameters were revealed in the demographic and clinical characteristics of participants who completed the study. Focus group showed significant reduction in HbA1c value with mean 1.1% as compared to cases with a mean 0.06%. Similarly, hypothesis on self-care management suggest significantly improved practices among focus group [M=2.94, SD=2.25] for case group M=0.47, SD=1.36; t[127.64]=-8.23, p≤0.001] with moderate effect size [eta squared=0.06]. Total physical activity was defined as the combination of non-leisure and leisure activities. There was a statistically significant difference for increase in total physical levels between the focus [M=14.01, SD=6.41] and case groups [13.21, SD=5.22; t[148.04]=-3.15, p=0.002] with no difference in the non-leisure activity [p=0.43]. As for the case group, there was no significant difference in SMBG practices from baseline [M=0.70, SD=1.35] to follow-up [M=0.47, SD=1.36, t[72]=0.97, P=0.34] and no relationship was found between the number of blood glucose tests done with demographic or clinical variables. This study offered improved self-care practices and physical activity after PHCP but with problematic dietary care. This might be due to social and cultural habits among Malaysian population.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  2. Tong WT, Vethakkan SR, Ng CJ
    BMJ Open, 2015 Jan 29;5(1):e006407.
    PMID: 25633285 DOI: 10.1136/bmjopen-2014-006407
    OBJECTIVE: To explore factors influencing poor glycaemic control in people with type 2 diabetes using insulin.
    RESEARCH DESIGN: A qualitative method comprising in-depth individual interviews. A semistructured interview guide was used. The interviews were audiorecorded, transcribed verbatim and analysed using a thematic approach.
    PARTICIPANTS: Seventeen people with type 2 diabetes using insulin with glycated haemoglobin (HbA1c) ≥9% for >1 year.
    SETTING: The Primary Care Clinic and Diabetes Clinic in the University of Malaya Medical Centre (UMMC), Malaysia.
    RESULTS: Data analysis uncovered four themes: lifestyle challenges in adhering to medical recommendations; psychosocial and emotional hurdles; treatment-related factors; lack of knowledge about and self-efficacy in diabetes self-care.
    CONCLUSIONS: Factors that explain the poor glycaemic control in people with type 2 diabetes using insulin were identified. Healthcare providers could use these findings to address patients' concerns during consultations and help to improve glycaemic control.
    Study site: Primary Care Clinic and Diabetes Clinic, University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Blood Glucose Self-Monitoring
  3. Nor Azlin MI, Adam R, Sufian SS, Wahab NA, Mustafa N, Kamaruddin NA, et al.
    J Obstet Gynaecol Res, 2011 Feb;37(2):132-7.
    PMID: 21159037 DOI: 10.1111/j.1447-0756.2010.01330.x
    AIM: To evaluate the safety and tolerability of once or twice daily neutral protamine hagedorn (NPH) insulin in fasting pregnant diabetics during Ramadan.
    METHODS: This was a prospective cohort study conducted during Ramadan 2006 and 2007. Twenty four pregnant diabetic women were given NPH insulin once at 5 pm or twice daily at 5 pm and 5 am. Demographic data, blood glucose control, insulin requirement, days of fasting and hypoglycemic episodes were analyzed.
    RESULTS: Most women were parity 1 (37.5%) in their second trimester (54.2%) and worked during the daytime (87.5%). Fourteen women (58.3%) had gestational diabetes mellitus, nine women (37.5%) had type 2 and one (4.2%) had type 1 diabetes mellitus. There were significant reductions in mean fasting blood glucose (6.16 mmol/L versus 5.34 mmol/L, P = 0.001), glycosylated hemoglobin (HbA1c) (6.70% ± 0.91 versus 6.64% ± 0.96, P = 0.001) and serum fructosamine (232.4 mmol/L ± 24.0 versus 217.0 mmol/L ± 24.3, P = 0.001) after Ramadan compared to before Ramadan. Throughout the four weeks of Ramadan, home blood glucose monitoring showed a reducing trend and was within the acceptable limits. Insulin requirement was increased from the first to the fourth week with a reduction in insulin dose noted after (38.5 U/day) compared to before the start of Ramadan (40 U/day). Most women (79.2%) were able to fast for more than 15 days without any hypoglycemia or fetal demise.
    CONCLUSION: Once or twice daily NPH insulin is a safe and tolerable option for pregnant diabetics who wish to fast during Ramadan.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  4. Tan MY, Magarey J
    Patient Educ Couns, 2008 Aug;72(2):252-67.
    PMID: 18467068 DOI: 10.1016/j.pec.2008.03.017
    OBJECTIVE: To investigate the self-care practices of Malaysian adults with diabetes and sub-optimal glycaemic control.
    METHODS: Using a one-to-one interviewing approach, data were collected from 126 diabetic adults from four settings. A 75-item questionnaire was used to assess diabetes-related knowledge and self-care practices regarding, diet, medication, physical activity and self-monitoring of blood glucose (SMBG).
    RESULTS: Most subjects had received advice on the importance of self-care in the management of their diabetes and recognised its importance. Sixty-seven subjects (53%) scored below 50% in their diabetes-related knowledge. Subjects who consumed more meals per day (80%), or who did not include their regular sweetened food intakes in their daily meal plan (80%), or who were inactive in daily life (54%), had higher mean fasting blood glucose levels (p=0.04). Subjects with medication non-adherence (46%) also tended to have higher fasting blood glucose levels. Only 15% of the subjects practiced SMBG. Predictors of knowledge deficit and poor self-care were low level of education (p = <0.01), older subjects (p=0.04) and Type 2 diabetes subjects on oral anti-hyperglycaemic medication (p = <0.01).
    CONCLUSION: There were diabetes-related knowledge deficits and inadequate self-care practices among the majority of diabetic patients with sub-optimal glycaemic control.
    PRACTICE IMPLICATIONS: This study should contribute to the development of effective education strategies to promote health for adults with sub-optimal diabetes control.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  5. Wong JS, Rahimah N
    Med J Malaysia, 2004 Aug;59(3):411-7.
    PMID: 15727390 MyJurnal
    Achieving glycaemic goals in diabetics has always been a problem, especially in a developing country with inadequate facilities such as in Sarawak in Malaysia. There are no reported studies on the control of diabetes mellitus in a diabetic clinic in the primary health care setting in Sarawak. This paper describes the profile of 1031 patients treated in Klinik Kesihatan Tanah Puteh Health Centre. The mean age was 59 years, the mean BMI 27 kg/m2. There was a female preponderance and mainly type-2 diabetes. Mean HbA1c was 7.4%. Glycaemic control was optimal in 28% (HbA1c <6.5%), fair in 34% (HbA1c 6.5-7.5%) and poor in 38% (HbA1c >7.5%). Reasonable glycaemic control can be achieved in the primary health care setting in Sarawak.
    Study site: Klinik Kesihatan Tanah Puteh, Sarawak, Malaysia
    Matched MeSH terms: Blood Glucose Self-Monitoring
  6. Rama Chandran S, A Vigersky R, Thomas A, Lim LL, Ratnasingam J, Tan A, et al.
    Diabetes Technol Ther, 2020 02;22(2):103-111.
    PMID: 31502876 DOI: 10.1089/dia.2019.0277
    Background:
    Complex changes of glycemia that occur in diabetes are not fully captured by any single measure. The Comprehensive Glucose Pentagon (CGP) measures multiple aspects of glycemia to generate the prognostic glycemic risk (PGR), which constitutes the relative risk of hypoglycemia combined with long-term complications. We compare the components of CGP and PGR across type 1 and type 2 diabetes.
    Methods:
    Participants: n = 60 type 1 and n = 100 type 2 who underwent continuous glucose monitoring (CGM). Mean glucose, coefficient of variation (%CV), intensity of hypoglycemia (INThypo), intensity of hyperglycemia (INThyper), time out-of-range (TOR <3.9 and >10 mmol/L), and PGR were calculated. PGR (median, interquartile ranges [IQR]) for diabetes types, and HbA1c classes were compared.
    Results:
    While HbA1c was lower in type 1 (type 1 vs. type 2: 8.0 ± 1.6 vs. 8.6 ± 1.7, P = 0.02), CGM-derived mean glucoses were similar across both groups (P > 0.05). TOR, %CV, INThypo, and INThyper were all higher in type 1 [type 1 vs. type 2: 665 (500, 863) vs. 535 (284, 823) min/day; 39% (33, 46) vs. 29% (24, 34); 905 (205, 2951) vs. 18 (0, 349) mg/dL × min2; 42,906 (23,482, 82,120) vs. 30,166 (10,276, 57,183) mg/dL × min2, respectively, all P 
    Matched MeSH terms: Blood Glucose Self-Monitoring
  7. Tan MY, Magarey JM, Chee SS, Lee LF, Tan MH
    Health Educ Res, 2011 Oct;26(5):896-907.
    PMID: 21715653 DOI: 10.1093/her/cyr047
    We assessed the effectiveness of a brief structured diabetes education programme based on the concept of self-efficacy on self-care and glycaemic control using single-blind study design. One hundred and sixty-four participants with poorly controlled diabetes from two settings were randomized using computer-generated list into control (n = 82) and intervention (n = 82) groups, of which 151 completed the study. Monthly interventions over 12 weeks addressed the self-care practices of diet, physical activity, medication adherence and self-monitoring of blood glucose (SMBG). These self-care practices were assessed at Weeks 0 and 12 using pre- and post-questionnaires in both groups together with glycated haemoglobin A1c (HbA1c) and diabetes knowledge. In the intention-to-treat analysis (n = 164), the intervention group improved their SMBG (P = <0.001), physical activity (P = 0.001), HbA1c (P = 0.03), diabetes knowledge (P = <0.001) and medication adherence. At Week 12, HbA1c difference adjusted for SMBG frequency, medication adherence and weight change remained significant (P = 0.03) compared with control group. For within group comparisons, diabetes knowledge (P = <0.001), HbA1c level (P = <0.001), SMBG (P = <0.001) and medication adherence (P = 0.008) improved from baseline in the intervention group. In the control group, only diabetes knowledge improved (P = <0.001). These findings can contribute to the development of self-management diabetes education in Malaysia.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  8. Eppens MC, Craig ME, Jones TW, Silink M, Ong S, Ping YJ, et al.
    Curr Med Res Opin, 2006 May;22(5):1013-20.
    PMID: 16709323 DOI: 10.1185/030079906X104795
    OBJECTIVE: To describe the glycaemic control, diabetes care and prevalence of complications in youth with type 2 diabetes from the Western Pacific Region.
    RESEARCH DESIGN AND METHODS: Cross-sectional, clinic-based audit of 331 patients aged < 18 years from 56 centres in Australia, China-Beijing, China-Shanghai, China-Hong Kong, Indonesia, Japan, South Korea, Malaysia, Philippines, Singapore, Taiwan and Thailand. Clinical and management data were recorded along with glycated haemoglobin (HbA(1c)), lipids and complication rates.
    MAIN OUTCOME MEASURES: Glycaemic control, complications, diabetes management.
    RESULTS: Median age was 14.9 years (interquartile range 13.2-16.4 years) and median diabetes duration 2.3 years (1.4-3.6 years). Median HbA(1c) was 7% (5.9-9.9%) and HbA(1c) was > 7.5% in 40% of patients. In multiple regression analysis, glycaemic control varied significantly between countries (p = 0.02); higher HbA(1c) was associated with fewer home blood glucose measurements (p = 0.005) and higher insulin dose/kg (p < 0.0001). Blood glucose monitoring was performed by 65% of patients (range 33-96% by country). In 25% of patients, management consisted of diet alone or no treatment (range 0-53% by country); oral anti-diabetic drugs alone were used in 49%, insulin alone in 11% and both in 15%. Microalbuminuria was found in 8% and hypertension in 24%. The risk of hypertension increased with higher BMI (OR 1.16, 95% CI 1.09-1.24, p < 0.0001); antihypertensive agents were used in 4% of patients.
    CONCLUSIONS: The management of type 2 diabetes in youth from the Western Pacific Region varies widely. Hypertension and microalbuminuria were frequent, but not commonly treated. Further investigation into the natural history and risk factors for complications in youth with type 2 diabetes is required to assist in developing evidence based management guidelines.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  9. Park SW, Bebakar WM, Hernandez PG, Macura S, Hersløv ML, de la Rosa R
    Diabet Med, 2017 02;34(2):174-179.
    PMID: 26773557 DOI: 10.1111/dme.13069
    AIMS: To compare the efficacy and safety of two titration algorithms for insulin degludec/insulin aspart (IDegAsp) administered once daily with metformin in participants with insulin-naïve Type 2 diabetes mellitus.

    METHODS: This open-label, parallel-group, 26-week, multicentre, treat-to-target trial, randomly allocated participants (1:1) to two titration arms. The Simple algorithm titrated IDegAsp twice weekly based on a single pre-breakfast self-monitored plasma glucose (SMPG) measurement. The Stepwise algorithm titrated IDegAsp once weekly based on the lowest of three consecutive pre-breakfast SMPG measurements. In both groups, IDegAsp once daily was titrated to pre-breakfast plasma glucose values of 4.0-5.0 mmol/l. Primary endpoint was change from baseline in HbA1c (%) after 26 weeks.

    RESULTS: Change in HbA1c at Week 26 was IDegAspSimple -14.6 mmol/mol (-1.3%) (to 52.4 mmol/mol; 6.9%) and IDegAspStepwise -11.9 mmol/mol (-1.1%) (to 54.7 mmol/mol; 7.2%). The estimated between-group treatment difference was -1.97 mmol/mol [95% confidence interval (CI) -4.1, 0.2] (-0.2%, 95% CI -0.4, 0.02), confirming the non-inferiority of IDegAspSimple to IDegAspStepwise (non-inferiority limit of ≤ 0.4%). Mean reduction in fasting plasma glucose and 8-point SMPG profiles were similar between groups. Rates of confirmed hypoglycaemia were lower for IDegAspStepwise [2.1 per patient years of exposure (PYE)] vs. IDegAspSimple (3.3 PYE) (estimated rate ratio IDegAspSimple /IDegAspStepwise 1.8; 95% CI 1.1, 2.9). Nocturnal hypoglycaemia rates were similar between groups. No severe hypoglycaemic events were reported.

    CONCLUSIONS: In participants with insulin-naïve Type 2 diabetes mellitus, the IDegAspSimple titration algorithm improved HbA1c levels as effectively as a Stepwise titration algorithm. Hypoglycaemia rates were lower in the Stepwise arm.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  10. Craig ME, Jones TW, Silink M, Ping YJ
    J Diabetes Complications, 2007 Sep-Oct;21(5):280-7.
    PMID: 17825751 DOI: 10.1016/j.jdiacomp.2006.04.005
    AIMS: The incidence of type 1 diabetes is increasing in many parts of Asia, where resources may not enable targets for glycemic control to be achieved. The aims of this study were to describe glycemic control, diabetes care, and complications in youth with type 1 diabetes from the Western Pacific Region and to identify factors associated with glycemic control and hypoglycemia.
    METHODS: A cross-sectional clinic-based study on 2312 children and adolescents (aged <18 years; 45% males) from 96 pediatric diabetes centers in Australia, China, Hong Kong, Indonesia, Japan, Malaysia, Philippines, Singapore, South Korea, Taiwan, and Thailand was conducted. Clinical and management details were recorded, and finger-pricked blood samples were obtained for central glycated hemoglobin (HbA(1c)).
    RESULTS: The median age of the patients was 12.5 years [interquartile range (IQR)=9.4-15.3 years]; diabetes duration, 4.4 years (IQR=2.5-7.2 years); and HbA(1c) level, 8.3% (IQR 7.4%-9.7%). Insulin treatment consisted of one or two daily injections in 61% of the patients (range=22%-90% by country), and home blood glucose monitoring (range=67%-100%) was practiced by 96%. HbA(1c) level was significantly associated with country, age, diabetes duration, sex, insulin dose per kilogram, insulin regimen, and frequency of home blood glucose measurement in multiple regression analysis. The incidence of severe hypoglycemia, defined as any episode requiring assistance in the previous 3 months, was 73 per 100 patient-years and was associated with country, male sex, higher HbA(1c) level, an insulin regimen with three or more injections, and more frequent home blood glucose testing. The incidence of diabetic ketoacidosis was 10 per 100 patient-years and was associated with country, higher HbA(1c) level, and higher insulin dose per kilogram.
    CONCLUSIONS: There is marked variability in glycemic control, hypoglycemia, complication rates, and diabetes care among children from the Western Pacific Region. Most are not achieving adequate glycemic control, placing them at high risk of microvascular complications.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  11. Rama Chandran S, Tay WL, Lye WK, Lim LL, Ratnasingam J, Tan ATB, et al.
    Diabetes Technol Ther, 2018 05;20(5):353-362.
    PMID: 29688755 DOI: 10.1089/dia.2017.0388
    BACKGROUND: Hypoglycemia is the major impediment to therapy intensification in diabetes. Although higher individualized HbA1c targets are perceived to reduce the risk of hypoglycemia in those at risk of hypoglycemia, HbA1c itself is a poor predictor of hypoglycemia. We assessed the use of glycemic variability (GV) and glycemic indices as independent predictors of hypoglycemia.

    METHODS: A retrospective observational study of 60 type 1 and 100 type 2 diabetes subjects. All underwent professional continuous glucose monitoring (CGM) for 3-6 days and recorded self-monitored blood glucose (SMBG). Indices were calculated from both CGM and SMBG. Statistical analyses included regression and area under receiver operator curve (AUC) analyses.

    RESULTS: Hypoglycemia frequency (53.3% vs. 24%, P Blood Glucose Index (LBGI)CGM, Glycemic Risk Assessment Diabetes Equation (GRADE)HypoglycemiaCGM, and Hypoglycemia IndexCGM predicted hypoglycemia well. %CVCGM and %CVSMBG consistently remained a robust discriminator of hypoglycemia in type 1 diabetes (AUC 0.88). In type 2 diabetes, a combination of HbA1c and %CVSMBG or LBGISMBG could help discriminate hypoglycemia.

    CONCLUSION: Assessment of glycemia should go beyond HbA1c and incorporate measures of GV and glycemic indices. %CVSMBG in type 1 diabetes and LBGISMBG or a combination of HbA1c and %CVSMBG in type 2 diabetes discriminated hypoglycemia well. In defining hypoglycemia risk using GV and glycemic indices, diabetes subtypes and data source (CGM vs. SMBG) must be considered.

    Matched MeSH terms: Blood Glucose Self-Monitoring
  12. Ashur ST, Shah SA, Bosseri S, Fah TS, Shamsuddin K
    Libyan J Med, 2016 Jan;11(1):31086.
    PMID: 28349838 DOI: 10.3402/ljm.v11.31086
    Background Achieving good glycaemic control is important in diabetes management. However, poor glycaemic control is widely reported. This article assessed the prevalence of uncontrolled and poor glycaemic control among Libyans with type 2 diabetes and examined the relative contribution of diabetes coping behaviours to their glycaemic control status. Methods A cross-sectional study was undertaken in 2013 in a large diabetes centre in Tripoli. The study included 523 respondents. Diabetes coping behaviours were measured using the revised version of the Summary of Diabetes Self-Care Activities measure (SDSCA) and the eight-item Morisky Medication Adherence Scale (MMAS-8(©)), while glycaemic control status was based on the HbA1c level. Results Mean HbA1c was 8.9 (±2.1), and of the 523 patients, only 114 (21.8%) attained the glycaemic control target of HbAc1 of less than 7.0%. Females (OR=1.74, 95% CI=1.03-2.91), patients on insulin and oral hypoglycaemic agents (OR=1.92, 95% CI=1.05-3.54), patients on insulin (OR=3.14, 95% CI=1.66-6.03), and low-medication adherents (OR=2.25, 95% CI=1.36-3.73) were more likely to have uncontrolled and poor glycaemic control, while exercise contributed to glycaemic control status as a protective factor (OR=0.85, 95% CI=0.77-0.94). Conclusion The findings from this study showed the considerable burden of uncontrolled and poor glycaemic control in one of the largest diabetes care settings in Libya. Medication adherence as well as exercise promotion programs would help in reducing the magnitude of poor glycaemic control.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  13. Deeb A, Elbarbary N, Smart CE, Beshyah SA, Habeb A, Kalra S, et al.
    Pediatr Diabetes, 2020 02;21(1):5-17.
    PMID: 31659852 DOI: 10.1111/pedi.12920
    Matched MeSH terms: Blood Glucose Self-Monitoring
  14. Law GR, Gilthorpe MS, Secher AL, Temple R, Bilous R, Mathiesen ER, et al.
    Diabetologia, 2017 04;60(4):618-624.
    PMID: 28105519 DOI: 10.1007/s00125-017-4205-7
    AIMS/HYPOTHESIS: This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA1clevels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA1c measurements are applicable to pregnant women with diabetes.
    METHODS: CGM data from 117 pregnant women (89 women with type 1 diabetes; 28 women with type 2 diabetes) were analysed. Average glucose levels were calculated from 5-7 day CGM profiles (mean 1275 glucose values per profile) and paired with a corresponding (±1 week) HbA1c measure. In total, 688 average glucose-HbA1c pairs were obtained across pregnancy (mean six pairs per participant). Average glucose level was used as the dependent variable in a regression model. Covariates were gestational week, study centre and HbA1c.
    RESULTS: There was a strong association between HbA1c and average glucose values in pregnancy (coefficient 0.67 [95% CI 0.57, 0.78]), i.e. a 1% (11 mmol/mol) difference in HbA1c corresponded to a 0.67 mmol/l difference in average glucose. The random effects model that included gestational week as a curvilinear (quadratic) covariate fitted best, allowing calculation of a pregnancy-specific eAG (PeAG). This showed that an HbA1c of 8.0% (64 mmol/mol) gave a PeAG of 7.4-7.7 mmol/l (depending on gestational week), compared with a standard eAG of 10.2 mmol/l. The PeAG associated with maintaining an HbA1c level of 6.0% (42 mmol/mol) during pregnancy was between 6.4 and 6.7 mmol/l, depending on gestational week.
    CONCLUSIONS/INTERPRETATION: The HbA1c-average glucose relationship is altered by pregnancy. Routinely generated standard eAG values do not account for this difference between pregnant and non-pregnant individuals and, thus, should not be used during pregnancy. Instead, the PeAG values deduced in the current study are recommended for antenatal clinical care.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  15. Moy FM, Ray A, Buckley BS, West HM
    Cochrane Database Syst Rev, 2017 Jun 11;6(6):CD009613.
    PMID: 28602020 DOI: 10.1002/14651858.CD009613.pub3
    BACKGROUND: Self-monitoring of blood glucose (SMBG) is recommended as a key component of the management plan for diabetes therapy during pregnancy. No existing systematic reviews consider the benefits/effectiveness of various techniques of blood glucose monitoring on maternal and infant outcomes among pregnant women with pre-existing diabetes. The effectiveness of the various monitoring techniques is unclear.

    OBJECTIVES: To compare techniques of blood glucose monitoring and their impact on maternal and infant outcomes among pregnant women with pre-existing diabetes.

    SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 November 2016), searched reference lists of retrieved studies and contacted trial authors.

    SELECTION CRITERIA: Randomised controlled trials (RCTs) and quasi-RCTs comparing techniques of blood glucose monitoring including SMBG, continuous glucose monitoring (CGM) or clinic monitoring among pregnant women with pre-existing diabetes mellitus (type 1 or type 2). Trials investigating timing and frequency of monitoring were also included. RCTs using a cluster-randomised design were eligible for inclusion but none were identified.

    DATA COLLECTION AND ANALYSIS: Two review authors independently assessed study eligibility, extracted data and assessed the risk of bias of included studies. Data were checked for accuracy. The quality of the evidence was assessed using the GRADE approach.

    MAIN RESULTS: This review update includes at total of 10 trials (538) women (468 women with type 1 diabetes and 70 women with type 2 diabetes). The trials took place in Europe and the USA. Five of the 10 included studies were at moderate risk of bias, four studies were at low to moderate risk of bias, and one study was at high risk of bias. The trials are too small to show differences in important outcomes such as macrosomia, preterm birth, miscarriage or death of baby. Almost all the reported GRADE outcomes were assessed as being very low-quality evidence. This was due to design limitations in the studies, wide confidence intervals, small sample sizes, and few events. In addition, there was high heterogeneity for some outcomes.Various methods of glucose monitoring were compared in the trials. Neither pooled analyses nor individual trial analyses showed any clear advantages of one monitoring technique over another for primary and secondary outcomes. Many important outcomes were not reported.1. Self-monitoring versus standard care (two studies, 43 women): there was no clear difference for caesarean section (risk ratio (RR) 0.78, 95% confidence interval (CI) 0.40 to 1.49; one study, 28 women) or glycaemic control (both very low-quality), and not enough evidence to assess perinatal mortality and neonatal mortality and morbidity composite. Hypertensive disorders of pregnancy, large-for-gestational age, neurosensory disability, and preterm birth were not reported in either study.2. Self-monitoring versus hospitalisation (one study, 100 women): there was no clear difference for hypertensive disorders of pregnancy (pre-eclampsia and hypertension) (RR 4.26, 95% CI 0.52 to 35.16; very low-quality: RR 0.43, 95% CI 0.08 to 2.22; very low-quality). There was no clear difference in caesarean section or preterm birth less than 37 weeks' gestation (both very low quality), and the sample size was too small to assess perinatal mortality (very low-quality). Large-for-gestational age, mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.3. Pre-prandial versus post-prandial glucose monitoring (one study, 61 women): there was no clear difference between groups for caesarean section (RR 1.45, 95% CI 0.92 to 2.28; very low-quality), large-for-gestational age (RR 1.16, 95% CI 0.73 to 1.85; very low-quality) or glycaemic control (very low-quality). The results for hypertensive disorders of pregnancy: pre-eclampsia and perinatal mortality are not meaningful because these outcomes were too rare to show differences in a small sample (all very low-quality). The study did not report the outcomes mortality or morbidity composite, neurosensory disability or preterm birth.4. Automated telemedicine monitoring versus conventional system (three studies, 84 women): there was no clear difference for caesarean section (RR 0.96, 95% CI 0.62 to 1.48; one study, 32 women; very low-quality), and mortality or morbidity composite in the one study that reported these outcomes. There were no clear differences for glycaemic control (very low-quality). No studies reported hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), neurosensory disability or preterm birth.5.CGM versus intermittent monitoring (two studies, 225 women): there was no clear difference for pre-eclampsia (RR 1.37, 95% CI 0.52 to 3.59; low-quality), caesarean section (average RR 1.00, 95% CI 0.65 to 1.54; I² = 62%; very low-quality) and large-for-gestational age (average RR 0.89, 95% CI 0.41 to 1.92; I² = 82%; very low-quality). Glycaemic control indicated by mean maternal HbA1c was lower for women in the continuous monitoring group (mean difference (MD) -0.60 %, 95% CI -0.91 to -0.29; one study, 71 women; moderate-quality). There was not enough evidence to assess perinatal mortality and there were no clear differences for preterm birth less than 37 weeks' gestation (low-quality). Mortality or morbidity composite, neurosensory disability and preterm birth less than 34 weeks were not reported.6. Constant CGM versus intermittent CGM (one study, 25 women): there was no clear difference between groups for caesarean section (RR 0.77, 95% CI 0.33 to 1.79; very low-quality), glycaemic control (mean blood glucose in the 3rd trimester) (MD -0.14 mmol/L, 95% CI -2.00 to 1.72; very low-quality) or preterm birth less than 37 weeks' gestation (RR 1.08, 95% CI 0.08 to 15.46; very low-quality). Other primary (hypertensive disorders of pregnancy, large-for-gestational age, perinatal mortality (stillbirth and neonatal mortality), mortality or morbidity composite, and neurosensory disability) or GRADE outcomes (preterm birth less than 34 weeks' gestation) were not reported.

    AUTHORS' CONCLUSIONS: This review found no evidence that any glucose monitoring technique is superior to any other technique among pregnant women with pre-existing type 1 or type 2 diabetes. The evidence base for the effectiveness of monitoring techniques is weak and additional evidence from large well-designed randomised trials is required to inform choices of glucose monitoring techniques.

    Matched MeSH terms: Blood Glucose Self-Monitoring/methods*
  16. Aneesa Abdul Rashid, Navin Kumar Devaraj, Zuhra Hamzah, Tan Chai Eng
    MyJurnal
    Introduction: Diabetic control depends partially on self-management. Diabetes self-care is reported to be a strong predictor of glycemic control in Type 2 Diabetes Mellitus (T2DM) patients. Factors contributing to better self-care include self-efficacy and social support. We aim to determine effects of these factors on glucose control in T2DM patients in a primary care clinic. Methods: This study utilised data from a bigger study looking into factors affecting social support and self-efficacy and their correlation in T2DM patients. This study was done among 329 T2DM pa- tients attending a primary care clinic in Selangor, Malaysia between November 2013- January 2014. Systematic ran- dom sampling was used. Instruments used were the MOS Social Support Survey and the Diabetic Management Self Efficacy Scale (DMSES). Patients’ socio-demographic data and glucose monitoring records were obtained. The asso- ciation between social support and self-efficacy with blood glucose control was determined using logistic regression. Results: The mean age of the respondents is 54.6 (+11.2), mostly female (55.3%) and Malay ethnicity (63.5%). Being older and retired were predictors for good glucose control (OR=1.05,p=0.01 and OR=2.2,p=0.023) respectively. There is also significant correlations between number of close friends/relatives with social support and self-efficacy (r=0.162,p=0.030 and r=0.190,p=0.01) respectively. The correlation of social support and self-efficacy with HbA1c levels are r= -0.044(p=0.426) and r= -0.08(p= 0.744) respectively. Conclusion: There were no correlations between social support and self-efficacy with the level of HbA1c among patients with T2DM in this study. We found older aged and retired patients to have better HbA1c levels.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  17. Ambigapathy R, Ambigapathy S, Ling HM
    NCD Malaysia, 2003;2(2):6-16.
    This cross sectional study describes the knowledge, attitude and practice (KAP) among 100 patients attending the diabetic clinic at Klinik Kesihatan Seri Manjung from December 2002 until January 2003. A face-to-face interview using a structured questionnaire was carried out for data collection. The results revealed that 87% of the respondents were able to answer 50% or more questions on knowledge correclty, while 98% of them had 50% or more score for the attitude questions. Ninety-nine percent of them reported 50% or more score for the questions on practice. However, only 56% of them practice all 4 of the practices that were asked - regular exercise, healthy diet, monitoring blood glucose level, and monitoring body weight. There was a significant positive correlation between knowledge and attitude (r=0.536, p<0.01), but there was no significant correlation found between attitude and practice. The results indicate that an increase in knowledge will increase the attitude, however this is not necessarily the same between attitude and practice. A better structured educational programme on diabetes and preventive measures should be conducted for all especially those with diabetes to improve their practice towards diabetes. Keywords: Diabetes Mellitus, Knowledge, Attitude and Practice (KAP)
    Matched MeSH terms: Blood Glucose Self-Monitoring
  18. Yee YC, Hashim R, Mohd Yahya AR, Bustami Y
    Sensors (Basel), 2019 May 31;19(11).
    PMID: 31159318 DOI: 10.3390/s19112511
    Glucose oxidase (EC 1.1.3.4) sensors that have been developed and widely used for glucose monitoring have generally relied on electrochemical principle. In this study, the potential use of colorimetric method for glucose detection utilizing glucose oxidase-magnetic cellulose nanocrystals (CNCs) is explored. Magnetic cellulose nanocrystals (magnetic CNCs) were fabricated using iron oxide nanoparticles (IONPs) and cellulose nanocrystals (CNCs) via electrostatic self-assembly technique. Glucose oxidase was successfully immobilized on magnetic CNCs using carbodiimide-coupling reaction. About 33% of GOx was successfully attached on magnetic CNCs, and the affinity of GOx-magnetic CNCs to glucose molecules was slightly higher than free enzymes. Furthermore, immobilization does not affect the specificity of GOx-magnetic CNCs towards glucose and can detect glucose from 0.25 mM to 2.5 mM. Apart from that, GOx-magnetic CNCs stored at 4 °C for 4 weeks retained 70% of its initial activity and can be recycled for at least ten consecutive cycles.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  19. Kong APS, Lim S, Yoo SH, Ji L, Chen L, Bao Y, et al.
    Diabetes Res Clin Pract, 2023 Jul;201:110718.
    PMID: 37196707 DOI: 10.1016/j.diabres.2023.110718
    Glucose monitoring has evolved from self-monitoring of blood glucose to glycated hemoglobin, and the latest continuous glucose monitoring (CGM). A key challenge to adoption of CGM for management of diabetes in Asia is the lack of regional CGM recommendations. Hence, thirteen diabetes-specialists from eight Asia-Pacific (APAC) countries/regions convened to formulate evidence-based, APAC-specific CGM recommendations for individuals with diabetes. We defined CGM metrics/targets and developed 13 guiding-statements on use of CGM in: (1) people with diabetes on intensive insulin therapy, and (2) people with type 2 diabetes on basal insulin with/without glucose lowering drugs. Continual use of CGM is recommended in individuals with diabetes on intensive insulin therapy and suboptimal glycemic control, or at high risk of problematic hypoglycemia. Continual/intermittent CGM may also be considered in individuals with type 2 diabetes on basal insulin regimen and with suboptimal glycemic control. In this paper, we provided guidance for optimizing CGM in special populations/situations, including elderly, pregnancy, Ramadan-fasting, newly diagnosed type 1 diabetes, and comorbid renal disease. Statements on remote CGM, and stepwise interpretation of CGM data were also developed. Two Delphi surveys were conducted to rate the agreement on statements. The current APAC-specific CGM recommendations provide useful guidance for optimizing use of CGM in the region.
    Matched MeSH terms: Blood Glucose Self-Monitoring
  20. Ng D, Noor NM, Yong SL
    J ASEAN Fed Endocr Soc, 2019;34(1):29-35.
    PMID: 33442134 DOI: 10.15605/jafes.034.01.06
    Objectives: To determine the prevalence of hypoglycaemia using continuous glucose monitoring system (CGMS) among insulin-treated pregnant women with diabetes whose glycosylated haemoglobin (HbA1c) were <6.0% and identify the risk factors associated with hypoglycaemia occurrence.

    Methodology: We conducted a cross-sectional study using 6-days CGMS to detect the prevalence of hypoglycaemia in 31 insulin-treated pregnant women with diabetes who achieved HbA1c <6.0%. Patients were required to log-keep their self-monitoring blood glucose (SMBG) readings and hypoglycaemia events.

    Results: Eight women experienced confirmed hypoglycaemia with additional seven experienced relative hypoglycaemia, giving rise to prevalence rate of 45.2% (one had both confirmed and relative hypoglycaemia). Nine relative hypoglycaemia and 17 confirmed hypoglycaemic events were recorded. Sixteen (94%) out of 17 confirmed hypoglycaemia events recorded by CGMS were asymptomatic and were missed despite performing regular SMBG. Nocturnal hypoglycaemia events were recorded in seven women. Univariable analysis did not identify any association between conventional risk factors and hypoglycaemia events in our cohort.

    Conclusion: Insulin-treated pregnant women with diabetes who achieved HbA1c <6.0% were associated with high prevalence of hypoglycaemia. Asymptomatic hypoglycaemia is common in our cohort and frequently missed despite regular SMBG. Present study did not identify any association between conventional risk factors and hypoglycaemia events in our cohort.

    Matched MeSH terms: Blood Glucose Self-Monitoring
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links