Displaying publications 1 - 20 of 104 in total

Abstract:
Sort:
  1. Zubair S, Fisal N, Baguda YS, Saleem K
    Sensors (Basel), 2013;13(10):13005-38.
    PMID: 24077319 DOI: 10.3390/s131013005
    Interest in the cognitive radio sensor network (CRSN) paradigm has gradually grown among researchers. This concept seeks to fuse the benefits of dynamic spectrum access into the sensor network, making it a potential player in the next generation (NextGen) network, which is characterized by ubiquity. Notwithstanding its massive potential, little research activity has been dedicated to the network layer. By contrast, we find recent research trends focusing on the physical layer, the link layer and the transport layers. The fact that the cross-layer approach is imperative, due to the resource-constrained nature of CRSNs, can make the design of unique solutions non-trivial in this respect. This paper seeks to explore possible design opportunities with wireless sensor networks (WSNs), cognitive radio ad-hoc networks (CRAHNs) and cross-layer considerations for implementing viable CRSN routing solutions. Additionally, a detailed performance evaluation of WSN routing strategies in a cognitive radio environment is performed to expose research gaps. With this work, we intend to lay a foundation for developing CRSN routing solutions and to establish a basis for future work in this area.
    Matched MeSH terms: Equipment Failure Analysis
  2. Zaman MR, Islam MT, Misran N, Yatim B
    ScientificWorldJournal, 2014;2014:831435.
    PMID: 24977230 DOI: 10.1155/2014/831435
    A radio frequency (RF) resonator using glass-reinforced epoxy material for C and X band is proposed in this paper. Microstrip line technology for RF over glass-reinforced epoxy material is analyzed. Coupling mechanism over RF material and parasitic coupling performance is explained utilizing even and odd mode impedance with relevant equivalent circuit. Babinet's principle is deployed to explicate the circular slot ground plane of the proposed resonator. The resonator is designed over four materials from different backgrounds which are glass-reinforced epoxy, polyester, gallium arsenide (GaAs), and rogers RO 4350B. Parametric studies and optimization algorithm are applied over the geometry of the microstrip resonator to achieve dual band response for C and X band. Resonator behaviors for different materials are concluded and compared for the same structure. The final design is fabricated over glass-reinforced epoxy material. The fabricated resonator shows a maximum directivity of 5.65 dBi and 6.62 dBi at 5.84 GHz and 8.16 GHz, respectively. The lowest resonance response is less than -20 dB for C band and -34 dB for X band. The resonator is prototyped using LPKF (S63) drilling machine to study the material behavior.
    Matched MeSH terms: Equipment Failure Analysis
  3. Zakaria NZ, Masnan MJ, Zakaria A, Shakaff AY
    Sensors (Basel), 2014;14(7):12233-55.
    PMID: 25010697 DOI: 10.3390/s140712233
    Herbal-based products are becoming a widespread production trend among manufacturers for the domestic and international markets. As the production increases to meet the market demand, it is very crucial for the manufacturer to ensure that their products have met specific criteria and fulfil the intended quality determined by the quality controller. One famous herbal-based product is herbal tea. This paper investigates bio-inspired flavour assessments in a data fusion framework involving an e-nose and e-tongue. The objectives are to attain good classification of different types and brands of herbal tea, classification of different flavour masking effects and finally classification of different concentrations of herbal tea. Two data fusion levels were employed in this research, low level data fusion and intermediate level data fusion. Four classification approaches; LDA, SVM, KNN and PNN were examined in search of the best classifier to achieve the research objectives. In order to evaluate the classifiers' performance, an error estimator based on k-fold cross validation and leave-one-out were applied. Classification based on GC-MS TIC data was also included as a comparison to the classification performance using fusion approaches. Generally, KNN outperformed the other classification techniques for the three flavour assessments in the low level data fusion and intermediate level data fusion. However, the classification results based on GC-MS TIC data are varied.
    Matched MeSH terms: Equipment Failure Analysis
  4. Zainal-Mokhtar K, Mohamad-Saleh J
    Sensors (Basel), 2013;13(9):11385-406.
    PMID: 24064598 DOI: 10.3390/s130911385
    This paper presents novel research on the development of a generic intelligent oil fraction sensor based on Electrical Capacitance Tomography (ECT) data. An artificial Neural Network (ANN) has been employed as the intelligent system to sense and estimate oil fractions from the cross-sections of two-component flows comprising oil and gas in a pipeline. Previous works only focused on estimating the oil fraction in the pipeline based on fixed ECT sensor parameters. With fixed ECT design sensors, an oil fraction neural sensor can be trained to deal with ECT data based on the particular sensor parameters, hence the neural sensor is not generic. This work focuses on development of a generic neural oil fraction sensor based on training a Multi-Layer Perceptron (MLP) ANN with various ECT sensor parameters. On average, the proposed oil fraction neural sensor has shown to be able to give a mean absolute error of 3.05% for various ECT sensor sizes.
    Matched MeSH terms: Equipment Failure Analysis
  5. Yu CY, Ang GY, Chan KG, Banga Singh KK, Chan YY
    Biosens Bioelectron, 2015 Aug 15;70:282-8.
    PMID: 25835520 DOI: 10.1016/j.bios.2015.03.048
    In this study, we developed a nucleic acid-sensing platform in which a simple, dry-reagent-based nucleic acid amplification assay is combined with a portable multiplex electrochemical genosensor. Preparation of an amplification reaction mix targeting multiple DNA regions of interest is greatly simplified because the lyophilized reagents need only be reconstituted with ultrapure water before the DNA sample is added. The presence of single or multiple target DNAs causes the corresponding single-stranded DNA (ssDNA) amplicons to be generated and tagged with a fluorescein label. The fluorescein-labeled ssDNA amplicons are then analyzed using capture probe-modified screen-printed gold electrode bisensors. Enzymatic amplification of the hybridization event is achieved through the catalytic production of electroactive α-naphthol by anti-fluorescein-conjugated alkaline phosphatase. The applicability of this platform as a diagnostic tool is demonstrated with the detection of toxigenic Vibrio cholerae serogroups O1 and O139, which are associated with cholera epidemics and pandemics. The platform showed excellent diagnostic sensitivity and specificity (100%) when challenged with 168 spiked stool samples. The limit of detection was low (10 colony-forming units/ml) for both toxigenic V. cholerae serogroups. A heat stability assay revealed that the dry-reagent amplification reaction mix was stable at temperatures of 4-56 °C, with an estimated shelf life of seven months. The findings of this study highlight the potential of combining a dry-reagent-based nucleic acid amplification assay with an electrochemical genosensor in a more convenient, sensitive, and sequence-specific detection strategy for multiple target nucleic acids.
    Matched MeSH terms: Equipment Failure Analysis
  6. Yang HZ, Lim KS, Qiao XG, Chong WY, Cheong YK, Lim WH, et al.
    Opt Express, 2013 Jun 17;21(12):14808-15.
    PMID: 23787668 DOI: 10.1364/OE.21.014808
    We present a new theoretical model for the broadband reflection spectra of etched FBGs which includes the effects of axial contraction and stress-induced index change. The reflection spectra of the etched FBGs with several different taper profiles are simulated based on the proposed model. In our observation, decaying exponential profile produces a broadband reflection spectrum with good uniformity over the range of 1540-1560 nm. An etched FBG with similar taper profile is fabricated and the experimental result shows good agreement with the theoretical model.
    Matched MeSH terms: Equipment Failure Analysis
  7. Yafouz B, Kadri NA, Ibrahim F
    Sensors (Basel), 2013 Jul 12;13(7):9029-46.
    PMID: 23857266 DOI: 10.3390/s130709029
    During the last three decades; dielectrophoresis (DEP) has become a vital tool for cell manipulation and characterization due to its non-invasiveness. It is very useful in the trend towards point-of-care systems. Currently, most efforts are focused on using DEP in biomedical applications, such as the spatial manipulation of cells, the selective separation or enrichment of target cells, high-throughput molecular screening, biosensors and immunoassays. A significant amount of research on DEP has produced a wide range of microelectrode configurations. In this paper; we describe the microarray dot electrode, a promising electrode geometry to characterize and manipulate cells via DEP. The advantages offered by this type of microelectrode are also reviewed. The protocol for fabricating planar microelectrodes using photolithography is documented to demonstrate the fast and cost-effective fabrication process. Additionally; different state-of-the-art Lab-on-a-Chip (LOC) devices that have been proposed for DEP applications in the literature are reviewed. We also present our recently designed LOC device, which uses an improved microarray dot electrode configuration to address the challenges facing other devices. This type of LOC system has the capability to boost the implementation of DEP technology in practical settings such as clinical cell sorting, infection diagnosis, and enrichment of particle populations for drug development.
    Matched MeSH terms: Equipment Failure Analysis
  8. Wulandhari LA, Wibowo A, Desa MI
    Comput Intell Neurosci, 2014;2014:419743.
    PMID: 25587265 DOI: 10.1155/2014/419743
    Condition diagnosis of multiple bearings system is one of the requirements in industry field, because bearings are used in many equipment and their failure can result in total breakdown. Conditions of bearings commonly are reflected by vibration signals data. In multiple bearing condition diagnosis, it will involve many types of vibration signals data; thus, consequently, it will involve many features extraction to obtain precise condition diagnosis. However, large number of features extraction will increase the complexity of the diagnosis system. Therefore, in this paper, we presented a diagnosis method which is hybridization of adaptive genetic algorithms (AGAs), back propagation neural networks (BPNNs), and grey relational analysis (GRA) to diagnose the condition of multiple bearings system. AGAs are used in the diagnosis algorithm to determine the best initial weights of BPNNs in order to improve the diagnosis accuracy. In addition, GRA is applied to determine and select the dominant features from the vibration signal data which will provide good diagnosis of multiple bearings system in less features extraction. The experiments results show that AGAs-BPNNs with GRA approaches can increase the accuracy of diagnosis in shorter processing time, compared with the AGAs-BPNNs without the GRA.
    Matched MeSH terms: Equipment Failure Analysis/methods*
  9. Wong KI, Ho MM
    PMID: 19162703 DOI: 10.1109/IEMBS.2008.4649200
    Extended patient monitoring has become increasingly important for detection of cardiac conditions, such as irregularities in the rhythms of the heart, while patient is practicing normal daily activity. This paper presents a design of a single lead wireless cardiac rhythm interpretive instrument that capable of capture the electrocardiogram (ECG) in digital format and transmitted to a remote base-station (i.e. PC) for storage and further interpretation. The design has achieved high quality of ECG and free of interference in the presence of motion.
    Matched MeSH terms: Equipment Failure Analysis
  10. Uthirajoo E, Ramiah H, Kanesan J, Reza AW
    PLoS One, 2014;9(7):e101862.
    PMID: 25033049 DOI: 10.1371/journal.pone.0101862
    For the first time, a new circuit to extend the linear operation bandwidth of a LTE (Long Term Evolution) power amplifier, while delivering a high efficiency is implemented in less than 1 mm2 chip area. The 950 µm × 900 µm monolithic microwave integrated circuit (MMIC) power amplifier (PA) is fabricated in a 2 µm InGaP/GaAs process. An on-chip analog pre-distorter (APD) is designed to improve the linearity of the PA, up to 20 MHz channel bandwidth. Intended for 1.95 GHz Band 1 LTE application, the PA satisfies adjacent channel leakage ratio (ACLR) and error vector magnitude (EVM) specifications for a wide LTE channel bandwidth of 20 MHz at a linear output power of 28 dBm with corresponding power added efficiency (PAE) of 52.3%. With a respective input and output return loss of 30 dB and 14 dB, the PA's power gain is measured to be 32.5 dB while exhibiting an unconditional stability characteristic from DC up to 5 GHz. The proposed APD technique serves to be a good solution to improve linearity of a PA without sacrificing other critical performance metrics.
    Matched MeSH terms: Equipment Failure Analysis
  11. Thavanathan J, Huang NM, Thong KL
    Biosens Bioelectron, 2014 May 15;55:91-8.
    PMID: 24368225 DOI: 10.1016/j.bios.2013.11.072
    The unique property of gold nanoparticles (Au NP) to induce colour change and the versatility of graphene oxides (GO) in surface modification makes them ideal in the application of colorimetric biosensor. Thus we developed a label free optical method to detect DNA hybridization through a visually observed colour change. The Au NP is conjugated to a DNA probe and is allowed to hybridize with the DNA target to the GO thus causing a change in colour from pinkish-red to purplish blue. Spectrophometry analysis gave a wavelength shift of 22 nm with 1 µM of DNA target. Sensitivity testing using serially diluted DNA conjugated GO showed that the optimum detection was at 63 nM of DNA target with the limit at 8 nM. This proves the possibility for the detection of DNA hybridization through the use of dual nanoparticle system by visual observation.
    Matched MeSH terms: Equipment Failure Analysis
  12. Tee HC, Lim PE, Seng CE, Nawi MA
    Bioresour Technol, 2012 Jan;104:235-42.
    PMID: 22130081 DOI: 10.1016/j.biortech.2011.11.032
    The objectives of this study are to compare the performance of newly developed baffled and conventional horizontal subsurface-flow (HSF) constructed wetlands in the removal of nitrogen at the hydraulic retention times (HRT) of 2, 3 and 5 days and to evaluate the potential of rice husk as wetland media for wastewater treatment. The results show that the planted baffled unit achieved 74%, 84% and 99% ammonia nitrogen (NH(4)(+)-N) removal versus 55%, 70% and 96% for the conventional unit at HRT of 2, 3 and 5 days, respectively. The better performance of the baffled unit was explained by the longer pathway due to the up-flow and down-flow conditions sequentially thus allowing more contact of the wastewater with the rhizomes and micro-aerobic zones. Near complete total oxidized nitrogen was observed due to the use of rice husk as wetland media which provided the COD as the electron donor in the denitrification process.
    Matched MeSH terms: Equipment Failure Analysis
  13. Tan CE, Fok MW, Luk KD, Cheung KM
    J Orthop Surg (Hong Kong), 2014 Aug;22(2):224-7.
    PMID: 25163961
    PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end plate on one side as control. On the other side, an identical screw was first inserted 10º caudal to the superior end plate, and then repositioned parallel to the superior end plate. The insertional torque and pullout strength were measured. RESULTS. Three of the specimens were excluded owing to pedicle fractures during the pullout test. Repositioned pedicle screws were significantly weaker than controls in terms of the maximum insertional torque (3.20 ± 0.28 vs. 2.04 ± 0.28 Nm, 36% difference, p<0.01) and pullout strength (1664 ± 378 vs.1391 ± 295 N, p<0.01). CONCLUSION. Repositioning pedicle screws should be avoided, especially when the pedicle wall is breached. If repositioning is deemed necessary, augmentation with polymethyl methacrylate or a screw with a larger diameter should be considered.
    Matched MeSH terms: Equipment Failure Analysis
  14. Soh HS, Ung NM, Ng KH
    Australas Phys Eng Sci Med, 2008 Jun;31(2):146-50.
    PMID: 18697706
    The advancement of digital imaging has prompted more medical institutions to go filmless. The computed radiography (CR) system is becoming an important tool not only in diagnostic imaging, but also in radiation oncology. A new CR system that was specially designed for the use in radiation oncology, Fuji IP cassette type PII has been introduced to the market in the middle of year 2006. This project aimed to study some basic physical characteristics of this new type of cassette and explore its application for performing quality assurance (QA) tests and portal imaging in radiotherapy. All the images were read by FCR 5000 Plus reader. The image was found to reach its saturation value of 1023 (due to the image was stored in 10 bits data) by depending on the sensitivity value being adjusted. The uniformity test gave the result of 0.12%. The cassette was used to perform the QA tests which were previously performed using film. All the results met the specification as stated in AAPM Task Group 40. The comparison for the portal images of PortalVision contrast-detail phantom showed that the spatial resolution of the images obtained by CR system (Fujifilm Co., Ltd., Tokyo, Japan) were better than the EPID (Varian Medical Systems, Inc., Palo Alto, USA) and film system (Eastman Kodak Co., New York, USA). The IP cassette type PII was found to be suitable as an alternative QA test tool and portal imaging in radiotherapy.
    Matched MeSH terms: Equipment Failure Analysis
  15. Shee YG, Al-Mansoori MH, Ismail A, Hitam S, Mahdi MA
    Opt Express, 2011 Jan 31;19(3):1699-706.
    PMID: 21368983 DOI: 10.1364/OE.19.001699
    We demonstrate a multiwavelength Brillouin-erbium fiber laser with double-Brillouin-frequency spacing. The wider channel spacing is realized by circulating the odd-order Stokes signals in the Brillouin gain medium through a four-port circulator. The circulated odd-order Stokes signals are amplified by the Brillouin gain and thus produce even-order Stokes signals at the output. These signals are then amplified by erbium gain block to form a ring-cavity laser. Ten channels with 0.174 nm spacing that are generated at 0.5 mW Brillouin pump power and 150 mW pump power at 1480 nm can be tuned from 1556 nm to 1564 nm. The minimum optical signal-to-noise ratio of the generated output channels is 30 dB with maximum power fluctuations of ±0.5 dB.
    Matched MeSH terms: Equipment Failure Analysis
  16. Shahemi N, Liza S, Abbas AA, Merican AM
    J Mech Behav Biomed Mater, 2018 11;87:1-9.
    PMID: 30031358 DOI: 10.1016/j.jmbbm.2018.07.017
    A revision of a metal-on-ultra high molecular weight (UHMWPE) bearing couple for total hip replacement was performed due to aseptic loosening after 23 years in-vivo. It is a major long-term failure identified from wear generation. This study includes performing failure analysis of retrieved polyethylene acetabular cup from Zimmer Trilogy® Acetabular system. The UHMWPE acetabular cup was retrieved from a 61 years old male patient with ability to walk but limited leg movement when he presented to hospital in early 2016 with complaint left thigh pain. It was 23 years after his primary total hip replacement procedure. Surface roughness and morphology condition were measured using 3D laser microscope and Scanning Electron Microscope (SEM) to evaluate and characterize the wear features on polyethylene acetabular cup surface. ATR-Fourier Transform Infra-Red (ATR-FTIR), differential scanning calorimetry (DSC) and gel permeation chromatography (GPC) were used to characterize the chemical composition of carbon-oxygen bonding, crystallinity percentage and molecular weight of the polymer liner that might changes the mechanical properties of polyethylene. Nano indentation is to measure hardness and elasticity modulus where the ratio of hardness to elastic modulus value can be reflected as the degradation of mechanical properties. A prominent difference of thickness between two regions resulted from acentric loading concentration was observed and wear rate were measured. The linear wear rate for thin side and thick side were 0.33 mm/year and 0.05 mm/year respectively. Molecular weight reduction of 57.5% and relatively low ratio of hardness to elastic modulus (3.59 × 10-3) were the indicator of major mechanical properties degradation happened on UHMWPE acetabular cup. This major degradation was contributed by oxidation and polishing wear feature accompanied with delamination, craters, ripple and cracks were the indication of extensive usage of UHMWPE from the suggested life span of acetabular cup application.
    Matched MeSH terms: Equipment Failure Analysis*
  17. Senthilpari C, Diwakar K, Singh AK
    Recent Pat Nanotechnol, 2009;3(1):61-72.
    PMID: 19149756
    The paper discuss the design of 1-bit full adder circuit using Shannon theorem. This proposed full adder circuit is used as one of the circuit component for implementation of Non- Restoring and Restoring divider circuits. The proposed adder and divider schematics are designed by using DSCH2 CAD tool and their layouts are generated by Microwind 3 VLSI CAD tool. The divider circuits are designed by using standard CMOS 0.35 microm feature size and corresponding power supply 3.5 V. The parameters analyses are carried out by BSIM 4 analysis. We have compared the simulated results of the Shannon based divider circuit with CPL and CMOS adder cell based divider circuits. We have further compared the results with published results and observed that the proposed adder cell based divider circuit dissipates lower power, gives faster response, lower latency, low EPI and high throughput.
    Matched MeSH terms: Equipment Failure Analysis
  18. Samsuri NM, Zamzuri AK, Al-Mansoori MH, Ahmad A, Mahdi MA
    Opt Express, 2008 Oct 13;16(21):16475-80.
    PMID: 18852754
    We demonstrate an enhanced architecture of Brillouin-Erbium fiber laser utilizing the reverse-S-shaped fiber section as the coupling mechanism. The enhancement is made by locating a common section of Erbium-doped fiber next to the single-mode fiber to amplify the Brillouin pumps and the oscillating Stokes lines. The requirement of having two Erbium gain sections to enhance the multiple Brillouin Stokes lines generation is neglected by the proposed fiber laser structure. The mode competitions arise from the self-lasing cavity modes of the fiber laser are efficiently suppressed by the stronger pre-amplified Brillouin pump power before entering the single mode fiber section. The maximum output power of 20 mW is obtained from the proposed fiber laser with 10 laser lines that equally separated by 0.089 nm spacing.
    Matched MeSH terms: Equipment Failure Analysis
  19. Samat SB, Evans CJ, Kadni T, Dolah MT
    Radiat Prot Dosimetry, 2009 Feb;133(3):186-91.
    PMID: 19299478 DOI: 10.1093/rpd/ncp035
    During the years 1985-2008, the Secondary Standards Dosimetry Laboratory of Malaysia (SSDL Malaysia) has participated 37 times in the IAEA/WHO intercomparison programmes. This paper reports an analysis of the intercomparison data and demonstrates that the quality of the SSDL calibration service is well within the limits required by IAEA.
    Matched MeSH terms: Equipment Failure Analysis
  20. Rozainee M, Ngo SP, Salema AA, Tan KG, Ariffin M, Zainura ZN
    Bioresour Technol, 2008 Mar;99(4):703-13.
    PMID: 17379511
    This study was focused on investigating the optimum fluidising velocity during the combustion of rice husk in a bench-scale fluidised bed combustor (ID 210mm) to obtain low carbon ash in the amorphous form. When all other parameters are held constant, the optimum fluidizing velocity aids in almost complete combustion, thereby releasing the entrapped carbon for further conversion. This results in ash with consistently low carbon content (less than 2wt%). The range of fluidising velocities investigated was from as low as 1.5U(mf) to as high as 8U(mf). It was found that the optimum fluidising velocity was approximately 3.3U(mf) as the mixing of rice husk with the bed was good with a high degree of penetration into the sand bed. The resulting ash retained its amorphous form with low residual carbon content (at 2.88wt%) and minimal sand contamination as shown by the X-ray diffraction analysis.
    Matched MeSH terms: Equipment Failure Analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links