Displaying publications 1 - 20 of 51 in total

Abstract:
Sort:
  1. Narhari R, Nazaruddin Wan Hassan WM, Mohamad Zaini RH, Che Omar S, Abdullah Nik Mohamad N, Seevaunnamtum P
    Anaesthesiol Intensive Ther, 2020;52(5):377-382.
    PMID: 33327695 DOI: 10.5114/ait.2020.101387
    INTRODUCTION: The choice of endotracheal tube (ETT) is important for successful orotracheal fibreoptic intubation (OFI). The aim of this study was to compare the use of the Parker flex tip (PFT) with the unoflex reinforced (UFR) ETT during OFI.

    MATERIAL AND METHODS: A total of 58 patients who underwent elective surgery under general anaesthesia were randomised to two ETT groups, the PFT group (n = 29) and the UFR group (n = 29), for OFI in simulated difficult intubation patients using a rigid cervical collar. After successful standardised induction and relaxation, OFI and railroading of selected ETT were subsequently performed by a similarly experienced practitioner. Ease of insertion, degree of manipulation, time to successful intubation, post-intubation complications and haemodynamic changes were recorded for both groups.

    RESULTS: he percentage of easy intubation was comparable between both groups with a slightly higher percentage in the UFR group than the PFT group (69.0% vs. 62.0%; P = 0.599). Degree of manipulation was also comparable between the two groups; the percentage of cases in which manipulation was not required was slightly higher in the UFR group than the PFT group (69.0% vs. 62.1%; P = 0.849). Time to successful intubation was also comparable between the groups, although the time was slightly shorter for the UFR group than the PFT group (56.9 s ± 39.7 s vs. 63.9 s ± 36.9 s; P = 0.488). There were also no significant differences in other parameters.

    CONCLUSIONS: The Parker flex tip ETT was comparable to the unoflex reinforced ETT for OFI in simulated difficult airway patients.

    Matched MeSH terms: Fiber Optic Technology/instrumentation; Fiber Optic Technology/methods*
  2. Che Omar S, Hardy Mohamad Zaini R, Fui Wong T, Nazaruddin W Hassan WM
    Anaesthesiol Intensive Ther, 2021;53(3):241-245.
    PMID: 34006053 DOI: 10.5114/ait.2021.105759
    INTRODUCTION: Airway management in patients with a cervical spine injury is a difficult and challenging task. The aim of this study was to compare the effectiveness of the Air-Q intubating laryngeal airway and the Ambu AuraGain laryngeal mask airway as a conduit for fibreoptic (FO) assisted endotracheal intubation in adult patients with a simulated cervical spine injury.

    MATERIAL AND METHODS: A total of 66 adult patients underwent elective surgery under general anaes-thesia, and they were randomized to two groups: the Air-Q (AQ) group (n = 33) and the Ambu AuraGain (AA) group (n = 33). A simulated cervical spine injury was created using a cervical collar, which was applied after the induction of general anaesthesia. Ease of insertion, time taken for successful insertion, time taken for successful FO guided endotracheal intubation, oropharyngeal leak pressure (OLP), Brimacombe score for FO laryngeal view, post-intubation complications and haemodynamic changes were recorded for both groups.

    RESULTS: The OLP was significantly higher in the AA group than in the AQ group (34.9 ± 6.4 vs. 28.6 ± 7.8 cm H 2 O; P = 0.001). Otherwise, there were no significant differences in the ease of insertion, time taken for successful insertion, time taken for successful FO guided endotracheal intubation, Brimacombe score for FO laryngeal view, haemodynamic parameters or complication rate between the two groups.

    CONCLUSIONS: Air-Q was comparably effective as Ambu AuraGain as a conduit for FO endotracheal intubation in patients with a simulated cervical spine injury; however, Ambu AuraGain has a better seal with significant OLP.

    Matched MeSH terms: Fiber Optic Technology
  3. Abass AK, Al-Mansoori MH, Jamaludin MZ, Abdullah F, Al-Mashhadani TF
    Appl Opt, 2013 Jun 1;52(16):3764-9.
    PMID: 23736332 DOI: 10.1364/AO.52.003764
    We experimentally investigate the performance of L-band multiwavelength Brillouin-Raman fiber laser (MBRFL) under forward and backward pumped environments utilizing a linear cavity. A short length of 1.18 km dispersion compensating fiber is used as a nonlinear gain medium for both Brillouin and Raman gain. Experimental results indicate that the gain in the copumped laser configuration is higher than the gain in the counterpumped configuration. A stable and constant number of Brillouin Stokes lines up to 23 Stokes, with channel spacing of 0.08 nm and more than 20 dB of optical signal to noise ratio, can be generated as well as tuning over 20 nm in the L-band region from 1570 to 1590 nm. The laser generating the Brillouin Stokes lines exhibits flat amplitude bandwidth and high average output power of 0.8 and 1.6 dBm for the copropagation and counterpropagation pumps, respectively. Moreover, the tuning range bandwidth of the MBRFL can be predicted from the oscillated Brillouin pump gain profile.
    Matched MeSH terms: Fiber Optic Technology
  4. Lim KS, Jasim AA, Damanhuri SS, Harun SW, Rahman BM, Ahmad H
    Appl Opt, 2011 Oct 20;50(30):5912-6.
    PMID: 22015420 DOI: 10.1364/AO.50.005912
    Effects of immersing a microfiber knot resonator (MKR) in liquid solutions that have refractive indices close to that of silica are experimentally demonstrated and theoretically analyzed. Significant improvement in resonance extinction ratio within 2 to 10 dB was observed. To achieve a better understanding, a qualitative analysis of the coupling ratio and round-trip attenuation of the MKR is performed by using a curve-fitting method. It was observed that the coupling coefficient at the knot region increased when immersed in liquids. However, depending on the initial state of the coupling and the quantity of the increment in the coupling coefficient when immersed in a liquid, it is possible that the MKR may experience a deficit in the coupling parameter due to the sinusoidal relationship with the coupling coefficient.
    Matched MeSH terms: Fiber Optic Technology
  5. Shee YG, Al-Mansoori MH, Ismail A, Hitam S, Mahdi MA
    Appl Opt, 2010 Jul 10;49(20):3956-9.
    PMID: 20648173 DOI: 10.1364/AO.49.003956
    We demonstrate a simple configuration for generating a double Brillouin frequency shift through the circulation of an odd-order Brillouin Stokes signal. It is operated based on cascaded Brillouin scattering in single-mode optical fibers that behave as the Brillouin gain media. A four-port circulator is incorporated into the setup to circulate the odd-order Brillouin Stokes signal in the fiber. It thus initiates a higher order Brillouin Stokes signal, which is double Brillouin frequency downshifted from the input signal. For the 5 km long fiber, the Brillouin pump power at 23 mW gives a clean output spectrum with 30 dB sideband suppression ratio. The output signal is 0.174 nm or approximately 21.7 GHz downshifted from the input signal.
    Matched MeSH terms: Fiber Optic Technology
  6. Ahmad H, Latif AA, Abdul Khudus MI, Zulkifli AZ, Zulkifli MZ, Thambiratnam K, et al.
    Appl Opt, 2013 Feb 1;52(4):818-23.
    PMID: 23385923 DOI: 10.1364/AO.52.000818
    A highly stable tunable dual-wavelength fiber laser (TDWFL) using graphene as a means to generate a highly stable output is proposed and generated. The TDWFL comprises a 1 m long, highly doped erbium-doped fiber (EDF) acting as the linear gain medium, with a 24-channel arrayed waveguide grating acting as a wavelength slicer as well as a tuning mechanism to generate different wavelength pairs. The tuned wavelength pairs can range from 0.8 to 18.2 nm. A few layers of graphene are incorporated into the laser cavity to induce the four-wave-mixing effect, which stabilizes the dual-wavelength output by suppressing the mode competition that arises as a result of homogenous broadening in the EDF.
    Matched MeSH terms: Fiber Optic Technology
  7. Hashim S, Bradley DA, Saripan MI, Ramli AT, Wagiran H
    Appl Radiat Isot, 2010 Apr-May;68(4-5):700-3.
    PMID: 19892557 DOI: 10.1016/j.apradiso.2009.10.027
    This paper describes a preliminary study of the thermoluminescence (TL) response of doped SiO(2) optical fibres subjected to (241)AmBe neutron irradiation. The TL materials, which comprise Al- and Ge-doped silica fibres, were exposed in close contact with the (241)AmBe source to obtain fast neutron interactions through use of measurements obtained with and without a Cd filter (the filter being made to entirely enclose the fibres). The neutron irradiations were performed for exposure times of 1-, 2-, 3-, 5- and 7-days in a neutron tank filled with water. In this study, use was also made of the Monte Carlo N-particle (MCNP) code version 5 (V5) to simulate the neutron irradiations experiment. It was found that the commercially available Ge-doped and Al-doped optical fibres show a linear dose response subjected to fast neutrons from (241)AmBe source up to seven days of irradiations. The simulation performed using MCNP5 also exhibits a similar pattern, albeit differing in sensitivity. The TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre, the total absorption cross section for Ge in both the fast and thermal neutrons region being some ten times greater than that of Al.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
  8. Shariffuddin II, Chaw SH, Ng LW, Lim CH, Zainal Abidin MF, Wan Zakaria WA, et al.
    BMC Anesthesiol, 2020 07 31;20(1):184.
    PMID: 32736516 DOI: 10.1186/s12871-020-01100-z
    BACKGROUND: The 4th National Audit Project of The Royal College of Anaesthetists and The Difficult Airway Society (NAP4) reported a higher incidence of supraglottic airway device (SAD) related pulmonary aspiration in obese patients especially with the first-generation SADs. The latest single-use SAD, the Protector™ provides a functional separation of the respiratory and digestive tracts and its laryngeal cuff with two ports allowing additional suction in tandem with the insertion of a gastric tube. The laryngeal cuff of LMA Protector™ allows a large catchment reservoir in the event of gastric content aspiration.

    METHODS: We evaluated the performance characteristics of the LMA Protector™ in 30 unparalysed, moderately obese patients. First attempt insertion rate, time for insertion, oropharyngeal leak pressure (OLP), and incidence of complications were recorded.

    RESULTS: We found high first and second attempt insertion rates of 28(93%) and 1(33%) respectively, with one failed attempt where no capnography trace could be detected, presumably from a downfolded device tip. The LMA Protector™ was inserted rapidly in 21.0(4.0) seconds and demonstrated high OLP of 31.8(5.4) cmH2O. Fibreoptic assessment showed a clear view of vocal cords in 93%. The incidence of blood staining on removal of device was 48%, postoperative sore throat 27%, dysphagia 10% and dysphonia 20% (all self-limiting, resolving a few hours postoperatively).

    CONCLUSIONS: We conclude that the LMA Protector™ was associated with easy, expedient first attempt insertion success, demonstrating high oropharyngeal pressures and good anatomical position in the moderately obese population, with relatively low postoperative airway morbidity.

    TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12617001152314 . Registered 7 August 2017.

    Matched MeSH terms: Fiber Optic Technology
  9. Ng BH, Ban Yu-Lin A, Low HJ, Faisal M
    BMJ Case Rep, 2020 Aug 25;13(8).
    PMID: 32843453 DOI: 10.1136/bcr-2020-235316
    Endobronchial hamartoma is a rare tumour. We report a 65-year-old woman with a history of recurrent pneumonia. Bronchoscopy revealed a 1 cm endobronchial mass obstructing the left upper lobe bronchus. Histopathological examination was consistent with a pulmonary hamartoma. This lesion was successfully debulked endoscopically with the use of a flexible cryoprobe without any complications. This case highlights both the importance of investigating recurrent pneumonia and the usefulness of endoscopic recanalisation in an obstructed segmental bronchus.
    Matched MeSH terms: Fiber Optic Technology
  10. Teah MK, Liew EHR, Wong MTF, Yeap TB
    BMJ Case Rep, 2021 Feb 19;14(2).
    PMID: 33608338 DOI: 10.1136/bcr-2020-238600
    Awake fibreoptic intubation (AFOI) is an established modality in patients with anticipated difficulty with tracheal intubation. This case demonstrates that with careful and meticulous preparations, AFOI can lead to improved airway management and excellent patient outcomes. A 38-year-old woman presented with severe trismus secondary to odentogenous abscess was identified preoperatively as having a potential difficult airway. AFOI was performed successfully using combined Spray-As-You-Go and dexmedetomidine technique.
    Matched MeSH terms: Fiber Optic Technology*
  11. Taha BA, Ali N, Sapiee NM, Fadhel MM, Mat Yeh RM, Bachok NN, et al.
    Biosensors (Basel), 2021 Jul 27;11(8).
    PMID: 34436055 DOI: 10.3390/bios11080253
    Understanding environmental information is necessary for functions correlated with human activities to improve healthcare quality and reduce ecological risk. Tapered optical fibers reduce some limitations of such devices and can be considerably more responsive to fluorescence and absorption properties changes. Data have been collected from reliable sources such as Science Direct, IEEE Xplore, Scopus, Web of Science, PubMed, and Google Scholar. In this narrative review, we have summarized and analyzed eight classes of tapered-fiber forms: fiber Bragg grating (FBG), long-period fiber grating (LPFG), Mach-Zehnder interferometer (MZI), photonic crystals fiber (PCF), surface plasmonic resonance (SPR), multi-taper devices, fiber loop ring-down technology, and optical tweezers. We evaluated many issues to make an informed judgement about the viability of employing the best of these methods in optical sensors. The analysis of performance for tapered optical fibers depends on four mean parameters: taper length, sensitivity, wavelength scale, and waist diameter. Finally, we assess the most potent strategy that has the potential for medical and environmental applications.
    Matched MeSH terms: Fiber Optic Technology*
  12. Kamuri MF, Zainal Abidin Z, Yaacob MH, Hamidon MN, Md Yunus NA, Kamarudin S
    Biosensors (Basel), 2019 Mar 14;9(1).
    PMID: 30875829 DOI: 10.3390/bios9010040
    This paper describes the development of an integrated system using a dry film resistant (DFR) microfluidic channel consisting of pulsed field dielectrophoretic field-flow-fractionation (DEP-FFF) separation and optical detection. The prototype chip employs the pulse DEP-FFF concept to separate the cells (Escherichia coli and Saccharomyces cerevisiae) from a continuous flow, and the rate of release of the cells was measured. The separation experiments were conducted by changing the pulsing time over a pulsing time range of 2⁻24 s and a flow rate range of 1.2⁻9.6 μ L min - 1 . The frequency and voltage were set to a constant value of 1 M Hz and 14 V pk-pk, respectively. After cell sorting, the particles pass the optical fibre, and the incident light is scattered (or absorbed), thus, reducing the intensity of the transmitted light. The change in light level is measured by a spectrophotometer and recorded as an absorbance spectrum. The results revealed that, generally, the flow rate and pulsing time influenced the separation of E. coli and S. cerevisiae. It was found that E. coli had the highest rate of release, followed by S. cerevisiae. In this investigation, the developed integrated chip-in-a lab has enabled two microorganisms of different cell dielectric properties and particle size to be separated and subsequently detected using unique optical properties. Optimum separation between these two microorganisms could be obtained using a longer pulsing time of 12 s and a faster flow rate of 9.6 μ L min - 1 at a constant frequency, voltage, and a low conductivity.
    Matched MeSH terms: Fiber Optic Technology/instrumentation; Fiber Optic Technology/methods*
  13. Prepageran N, Omar R, Raman R
    Ear Nose Throat J, 2005 Sep;84(9):564.
    PMID: 16261756
    Matched MeSH terms: Fiber Optic Technology
  14. Abdul Rahim R, Leong LC, Chan KS, Rahiman MH, Pang JF
    ISA Trans, 2008 Jan;47(1):3-14.
    PMID: 17709106
    This paper presents the implementing multiple fan beam projection technique using optical fibre sensors for a tomography system. From the dynamic experiment of solid/gas flow using plastic beads in a gravity flow rig, the designed optical fibre sensors are reliable in measuring the mass flow rate below 40% of flow. Another important matter that has been discussed is the image processing rate or IPR. Generally, the applied image reconstruction algorithms, the construction of the sensor and also the designed software are considered to be reliable and suitable to perform real-time image reconstruction and mass flow rate measurements.
    Matched MeSH terms: Fiber Optic Technology
  15. Ibrahim S, Green RG, Dutton K, Abdul Rahim R
    ISA Trans, 2002 Jan;41(1):13-8.
    PMID: 12014798
    This paper describes a system using lensed optical fiber sensors that are arranged in the form of two orthogonal projections. The sensors are placed around a process vessel for upstream and downstream measurements. The purpose of the system is for on-line monitoring of particles and droplets being conveyed by a fluid. The lenses were constructed using a custom heating fixture. The fixture enables the lenses to be constructed with similar radii resulting in identical characteristics with minimum differences in transmitted intensity and emission angle. By collimating radiation from two halogen bulbs, radiation can be obtained by the sensors with radiation intensity related to the nature of the media. Each sensor interrogates a finite section of the measurement section. Each sensor provides a view. Parallel sensors provide a projection. Signal processing is carried out on the measured data in the time and frequency domains to investigate the latent information present in the flow signals.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*; Fiber Optic Technology/methods
  16. Hazura Haroon, Abdul Aziz Abu Mansor, Hanim Abdul Razak, Siti Khadijah Idris, Anis Suhaila Mohd Zain, Fauziyah Salehuddin
    MyJurnal
    An investigation of bending loss characteristics of a Polymer Optical Fiber is presented experimentally. Loss of optical power in an optical fiber due to bending has been investigated for a wavelength of 650 nm. Variations of bending loss with different lengths have been measured, with a number of radii of curvature. Bending Loss equations for short length POF is proposed, which shows the dependence of bending loss on the curvature radii. The equations can be an initial reference or aid in predicting the loss contributes by the polymer optical fiber.
    Matched MeSH terms: Fiber Optic Technology
  17. Hazura Haroon, Siti Sarah Khalid
    MyJurnal
    This paper provides a qualitative overview of different Optical Fiber Sensors (OFS),
    which play important role in the field of sensors due to their excellent
    characteristics, spontaneous response and easy handling system. The current
    state of the art of optical fiber technology is reviewed, namely based on its main
    characteristics and sensing advantages. In addition, the working principle of OFS
    and their applications are discussed, particularly for sensor employment.
    Matched MeSH terms: Fiber Optic Technology
  18. Zabir, A.F., Frawley, G., Squire, P.
    MyJurnal
    We here describe a videolaryngoscope assisted fibreoptic tracheal intubation in a 17-year-old patient with Hunter Syndrome (Mucopolysaccharidosis Type II) and known difficult intubation who required posterior cervical fusion surgery for cervical canal stenosis. The patient had a history of failed nasal and oral fibreoptic intubation. The use of a videolaryngoscope enabled continuous visualization of the tracheal inlet and allowed a straightforward nasal fibreoptic intubation attempt without complications. This report suggests a viable alternative for the management of a known difficult airway in children with mucopolysaccharidosis.
    Matched MeSH terms: Fiber Optic Technology
  19. Rahman HA, Harun SW, Arof H, Irawati N, Musirin I, Ibrahim F, et al.
    J Biomed Opt, 2014 May;19(5):057009.
    PMID: 24839996 DOI: 10.1117/1.JBO.19.5.057009
    An enhanced dental cavity diameter measurement mechanism using an intensity-modulated fiber optic displacement sensor (FODS) scanning and imaging system, fuzzy logic as well as a single-layer perceptron (SLP) neural network, is presented. The SLP network was employed for the classification of the reflected signals, which were obtained from the surfaces of teeth samples and captured using FODS. Two features were used for the classification of the reflected signals with one of them being the output of a fuzzy logic. The test results showed that the combined fuzzy logic and SLP network methodology contributed to a 100% classification accuracy of the network. The high-classification accuracy significantly demonstrates the suitability of the proposed features and classification using SLP networks for classifying the reflected signals from teeth surfaces, enabling the sensor to accurately measure small diameters of tooth cavity of up to 0.6 mm. The method remains simple enough to allow its easy integration in existing dental restoration support systems.
    Matched MeSH terms: Fiber Optic Technology/instrumentation; Fiber Optic Technology/methods*
  20. Rahman HA, Che Ani AI, Harun SW, Yasin M, Apsari R, Ahmad H
    J Biomed Opt, 2012 Jul;17(7):071308.
    PMID: 22894469 DOI: 10.1117/1.JBO.17.7.071308
    The purpose of this study is to investigate the potential of intensity modulated fiber optic displacement sensor scanning system for the imaging of dental cavity. Here, we discuss our preliminary results in the imaging of cavities on various teeth surfaces, as well as measurement of the diameter of the cavities which are represented by drilled holes on the teeth surfaces. Based on the analysis of displacement measurement, the sensitivities and linear range for the molar, canine, hybrid composite resin, and acrylic surfaces are obtained at 0.09667 mV/mm and 0.45 mm; 0.775 mV/mm and 0.4 mm; 0.5109 mV/mm and 0.5 mm; and 0.25 mV/mm and 0.5 mm, respectively, with a good linearity of more than 99%. The results also show a clear distinction between the cavity and surrounding tooth region. The stability, simplicity of design, and low cost of fabrication make it suitable for restorative dentistry.
    Matched MeSH terms: Fiber Optic Technology/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links