Displaying publications 1 - 20 of 81 in total

Abstract:
Sort:
  1. Lai MY, Ooi CH, Lau YL
    Malar J, 2021 Mar 25;20(1):166.
    PMID: 33766038 DOI: 10.1186/s12936-021-03707-0
    BACKGROUND: As an alternative to PCR methods, LAMP is increasingly being used in the field of molecular diagnostics. Under isothermal conditions at 65 °C, the entire procedure takes approximately 30 min to complete. In this study, we establish a sensitive and visualized LAMP method in a closed-tube system for the detection of Plasmodium knowlesi.

    METHODS: A total of 71 malaria microscopy positive blood samples collected in blood spots were obtained from the Sarawak State Health Department. Using 18s rRNA as the target gene, nested PCR and SYBR green I LAMP assay were performed following the DNA extraction. The colour changes of LAMP end products were observed by naked eyes.

    RESULTS: LAMP assay demonstrated a detection limit of 10 copies/µL in comparison with 100 copies/µL nested PCR. Of 71 P. knowlesi blood samples collected, LAMP detected 69 microscopy-positive samples. LAMP exhibited higher sensitivity than nested PCR assay. The SYBR green I LAMP assay was 97.1% sensitive (95% CI 90.2-99.7%) and 100% specific (95% CI 83.2-100%). Without opening the cap, incorporation of SYBR green I into the inner cap of the tube enabled the direct visualization of results upon completion of amplification. The positives instantaneously turned green while the negatives remained orange.

    CONCLUSIONS: These results indicate that SYBR green I LAMP assay is a convenient diagnosis tool for the detection of P. knowlesi in remote settings.

    Matched MeSH terms: Molecular Diagnostic Techniques/instrumentation*
  2. Saidin S, Othman N, Noordin R
    Eur J Clin Microbiol Infect Dis, 2019 Jan;38(1):15-38.
    PMID: 30255429 DOI: 10.1007/s10096-018-3379-3
    Amoebiasis, an enteric protozoan disease caused by Entamoeba histolytica, is a public health problem in many developing countries, causing up to 100,000 fatal cases annually. Detection of the pathogenic E. histolytica and its differentiation from the non-pathogenic Entamoeba spp. play a crucial role in the clinical management of patients. Laboratory diagnosis of intestinal amoebiasis in developing countries still relies on labour-intensive and insensitive methods involving staining of stool sample and microscopy. Newer and more sensitive methods include a variety of antigen detection ELISAs and rapid tests; however, their diagnostic sensitivity and specificity seem to vary between studies, and some tests do not distinguish among the Entamoeba species. Molecular detection techniques are highly sensitive and specific and isothermal amplification approaches may be developed into field-applicable tests; however, cost is still a barrier for their use as a routine laboratory test method in most endemic areas. Laboratory diagnosis of extraintestinal amoebiasis faces challenges of lack of definitive detection of current infection and commercially available point-of-care tests. For both types of amoebiasis, there is still a need for highly sensitive and specific tests that are rapid and cost-effective for use in developing countries where the disease is prevalent. In recent years, new molecules of diagnostic value are being discovered and new tests developed. The advances in 'omics' technologies are enabling discoveries of new biomarkers that may help distinguish between different infection stages.
    Matched MeSH terms: Molecular Diagnostic Techniques*
  3. Lai MY, Lau YL
    Am J Trop Med Hyg, 2022 Oct 12;107(4):815-819.
    PMID: 35970289 DOI: 10.4269/ajtmh.22-0136
    We developed a combination of recombinase polymerase and loop-mediated isothermal amplification methods (RAMP) for rapid screening of five human Plasmodium spp. simultaneously. RAMP is a two-stage isothermal amplification method, which consists of a first-stage recombinase polymerase amplification and a second-stage loop-mediated isothermal amplification. Under these two isothermal conditions, five Plasmodium spp. were amplified in less than 40 minutes. We demonstrated RAMP assay with 10-fold better limit of detection than a single (loop-mediated isothermal amplification) LAMP. As compared with microscopy, RAMP assay showed 100% sensitivity (95% CI: 95.65-100.00%) and 100% specificity (95% CI: 69.15-100.00%). The end products were inspected by the color changes of neutral red. Positive reactions were indicated by pink while the negative reactions remained yellow. The combination assay established in this study can be used as a routine diagnostic method for malaria.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods
  4. Lai MY, Bukhari FDM, Zulkefli NZ, Ismail I, Mustapa NI, Soh TST, et al.
    BMC Infect Dis, 2021 Nov 17;21(1):1162.
    PMID: 34789179 DOI: 10.1186/s12879-021-06876-0
    BACKGROUND: Current assays for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) rely on time consuming, costly and laboratory based methods for virus isolation, purification and removing inhibitors. To address this limitation, we propose a simple method for testing RNA from nasopharyngeal swab samples that bypasses the RNA purification step.

    METHODS: In the current project, we have described two extraction-free reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of SARS-CoV-2 by using E gene and RdRp gene as the targets.

    RESULTS: Here, results showed that reverse transcription loop-mediated isothermal amplification assays with 88.4% sensitive (95% CI: 74.9-96.1%) and 67.4% sensitive (95% CI: 51.5-80.9%) for E gene and RdRp gene, respectively.

    CONCLUSION: Without the need of RNA purification, our developed RT-LAMP assays for direct detection of SARS-CoV-2 from nasopharyngeal swab samples could be turned into alternatives to qRT-PCR for rapid screening.

    Matched MeSH terms: Molecular Diagnostic Techniques
  5. Mustafa MI, Al-Marzooq F, How SH, Kuan YC, Ng TH
    Trop Biomed, 2011 Dec;28(3):531-44.
    PMID: 22433882 MyJurnal
    Community-acquired pneumonia (CAP) is still a major cause of morbidity and mortality especially to children and compromised hosts, such as the old and those with underlying chronic diseases. Knowledge of pathogens causing CAP constitutes the basis for selection of antimicrobial treatment. Previous data have shown that etiological agents can be identified in only up to 50% of patients, but this figure can be improved by using polymerase chain reaction (PCR). This study was designed to evaluate multiplex real-time PCR as a method for rapid differential detection of five bacterial causes of CAP (Streptococcus pneumoniae, Burkholderia pseudomallei and atypical bacterial pathogens namely Mycoplasma pneumoniae, Chlamydophila pneumoniae and Legionella pneumophila) in CAP patients attending Hospital Tengku Ampuan Afzan (HTAA)/ Kuantan, Pahang, Malaysia. Two previously developed multiplex real-time PCR assays, duplex for the differential detection of S. pneumoniae and B. pseudomallei and triplex for the atypical bacterial pathogens, were used to detect a bacterial cause of CAP in blood and respiratory samples. Thus, 46 blood and 45 respiratory samples collected from 46 adult CAP patients admitted to HTAA were analysed by multiplex real-time PCR assays and conventional methods. The microbial etiology of CAP could be established for 39.1% (18/46) of CAP patients by conventional methods and this was increased to 65.2% (30/46) with the additional use of real-time PCR. The most frequently detected pathogens were S. pneumoniae (21.7% - all by PCR alone), Klebsiella pneumoniae (17.3%), B. pseudomallei (13% - 83% of them positive by PCR alone and 17% by both culture and PCR), Pseudomonas aeruginosa (6.5%), M. pneumoniae (6.5% - all by serology), C. pneumoniae (4.3% - all positive by both PCR and serology), L. pneumophila (2.1% - all by PCR alone), Escherichia coli (4.3%). Haemophilus infuenzae, Acinetobacter lwoffii and Acinetobacter baumannii were detected by conventional methods (2.1% for each).
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  6. Ilham NE, Joseph NSM, Bahtiar Affendy N, Mohd Taib N, Vasantha KN, Masri SN
    Trop Biomed, 2020 Jun 01;37(2):357-362.
    PMID: 33612804
    Leptospirosis is a common febrile illness in Malaysia. The disease is caused by pathogenic bacteria called leptospires that are transmitted directly or indirectly from animals to humans via contaminated water or soil. It is a potentially serious but treatable disease. Its symptoms may mimic those of other unrelated febrile illnesses such as dengue, influenza, meningitis, hepatitis or viral haemorrhagic fevers. The spectrum of the disease is extremely wide, ranging from subclinical infection to a severe syndrome of multiorgan infection with high mortality. The diagnosis requires high suspicion with history of exposure to water or environment possibly contaminated with infected animal urine. This is a case of a 13 year-oldgirl with no known medical illness, and a history of exposure to outdoor activities. However, paired sera for leptospirosis serology was not diagnostic. She then developed septic shock on day 14 of illness. But due to high suspicion of leptospirosis, antibiotic therapy was upgraded to ceftriaxone and samples were sent for further testing which revealed that leptospires were detected in the urine, using molecular technique. She improved after treated as leptospirosis.
    Matched MeSH terms: Molecular Diagnostic Techniques
  7. Teoh BT, Sam SS, Tan KK, Johari J, Abd-Jamil J, Hooi PS, et al.
    Sci Rep, 2016 06 09;6:27663.
    PMID: 27278716 DOI: 10.1038/srep27663
    Timely and accurate dengue diagnosis is important for differential diagnosis and immediate implementation of appropriate disease control measures. In this study, we compared the usefulness and applicability of NS1 RDT (NS1 Ag Strip) and qRT-PCR tests in complementing the IgM ELISA for dengue diagnosis on single serum specimen (n = 375). The NS1 Ag Strip and qRT-PCR showed a fair concordance (κ = 0.207, p = 0.001). While the NS1 Ag Strip showed higher positivity than qRT-PCR for acute (97.8% vs. 84.8%) and post-acute samples (94.8% vs. 71.8%) of primary infection, qRT-PCR showed higher positivity for acute (58.1% vs. 48.4%) and post-acute (50.0% vs.41.4%) samples in secondary infection. IgM ELISA showed higher positivity in samples from secondary dengue (74.2-94.8%) than in those from primary dengue (21.7-64.1%). More primary dengue samples showed positive with combined NS1 Ag Strip/IgM ELISA (99.0% vs. 92.8%) whereas more secondary samples showed positive with combined qRT-PCR/IgM ELISA (99.4% vs. 96.2%). Combined NS1 Ag Strip/IgM ELISA is a suitable combination tests for timely and accurate dengue diagnosis on single serum specimen. If complemented with qRT-PCR, combined NS1 Ag Strip/IgM ELISA would improve detection of secondary dengue samples.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*; Molecular Diagnostic Techniques/standards
  8. Lau YL, Fong MY, Mahmud R, Chang PY, Palaeya V, Cheong FW, et al.
    Malar J, 2011;10:197.
    PMID: 21774805 DOI: 10.1186/1475-2875-10-197
    The emergence of Plasmodium knowlesi in humans, which is in many cases misdiagnosed by microscopy as Plasmodium malariae due to the morphological similarity has contributed to the needs of detection and differentiation of malaria parasites. At present, nested PCR targeted on Plasmodium ssrRNA genes has been described as the most sensitive and specific method for Plasmodium detection. However, this method is costly and requires trained personnel for its implementation. Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method was developed for the clinical detection of P. knowlesi. The sensitivity and specificity of LAMP was evaluated in comparison to the results obtained via microscopic examination and nested PCR.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  9. Jainlabdin MH, Batra A, Sánchez Paredes E, Hernández Hernández F, Fu G, Tovar-Torres J
    Sci Rep, 2019 10 11;9(1):14692.
    PMID: 31604994 DOI: 10.1038/s41598-019-51198-6
    Invasive candidiasis is one of the most common nosocomial fungal infections worldwide. Delayed implementation of effective antifungal treatment caused by inefficient Candida diagnosis contributes to its notoriously high mortality rates. The availability of better Candida diagnostic tools would positively impact patient outcomes. Here, we report on the development of a single-tube, dual channel pentaplex molecular diagnostic assay based on Multiplex Probe Amplification (MPA) technology. It allows simultaneous identification of C. auris, C. glabrata and C. krusei, at species-level as well as of six additional albicans and non-albicans pathogenic Candida at genus level. The assay overcomes the one-channel one-biomarker limitation of qPCR-based assays. Assay specificities are conferred by unique biomarker probe pairs with characteristic melting temperatures; post-amplification melting curve analysis allows simple identification of the infectious agent. Alerting for the presence of C. auris, the well-characterised multi-drug resistant outbreak strain, will facilitate informed therapy decisions and aid antifungal stewardship. The MPA-Candida assay can also be coupled to a pan-Fungal assay when differentiation between fungal and bacterial infections might be desirable. Its multiplexing capacity, detection range, specificity and sensitivity suggest the potential use of this novel MPA-Candida assay in clinical diagnosis and in the control and management of hospital outbreaks.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  10. Khan AH, Noordin R
    Eur J Clin Microbiol Infect Dis, 2020 Jan;39(1):19-30.
    PMID: 31428897 DOI: 10.1007/s10096-019-03680-2
    Infection by Toxoplasma gondii is prevalent worldwide. The parasite can infect a broad spectrum of vertebrate hosts, but infection of fetuses and immunocompromised patients is of particular concern. Easy-to-perform, robust, and highly sensitive and specific methods to detect Toxoplasma infection are important for the treatment and management of patients. Rapid diagnostic methods that do not sacrifice the accuracy of the assay and give reproducible results in a short time are highly desirable. In this context, rapid diagnostic tests (RDTs), especially with point-of-care (POC) features, are promising diagnostic methods in clinical microbiology laboratories, especially in areas with minimal laboratory facilities. More advanced methods using microfluidics and sensor technology will be the future trend. In this review, we discuss serological and molecular-based rapid diagnostic tests for detecting Toxoplasma infection in humans as well as animals.
    Matched MeSH terms: Molecular Diagnostic Techniques
  11. Subakir H, Chong YM, Chan YF, Hasan MS, Jamaluddin MFH, Pang YK, et al.
    J Med Microbiol, 2020 Jan;69(1):49-51.
    PMID: 31750812 DOI: 10.1099/jmm.0.001108
    Introduction.Burkholderia pseudomallei (melioidosis) is an important cause of community-acquired pneumonia (CAP) in the tropics. Selective medium is recommended for laboratory diagnosis with non-sterile respiratory samples, while PCR is not routinely used due to variable reported performance. The effectiveness of these diagnostic modalities varies by site.Aim. To compare selective media and real-time PCR (qPCR) with routine media in detecting B. pseudomallei in CAP respiratory samples in a low-incidence setting in Kuala Lumpur, Malaysia.Methodology. Respiratory samples were routinely cultured on blood, chocolate and MacConkey agar (RESP-ROUTINE), and compared to culture on selective Ashdown medium (RESP-SELECTIVE) and qPCR. The gold standard was routine culture of B. pseudomallei from any site (ALL-ROUTINE).Results.B. pseudomallei was detected in 8/204 (3.9 %) samples. Overall sensitivity rates differed (P=0.03) for qPCR (100%), RESP-SELECTIVE (87.5%) and RESP-ROUTINE (50%). There was a trend towards lower median days to positive culture for RESP-SELECTIVE (1 day) compared to RESP-ROUTINE (2 days, P=0.08) and ALL-ROUTINE (2 days, P=0.06). Reagent costs for each additional detection were USD59 for RESP-SELECTIVE and USD354 for PCR.Conclusions. In a low-incidence setting, selective culture of respiratory samples on Ashdown was more sensitive and allowed quicker identification than routine media, at reasonable cost. Blood cultures are critical, confirming four cases missed by routine respiratory culture. Selective medium is useful in early pneumonia (pre-sepsis) and resource-limited settings where blood cultures are infrequently done. Real-time PCR is costly, but highly sensitive and useful for high-risk patients with diabetes, cancer or immunosuppressants, or requiring ventilation or intensive care.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  12. Maran S, Faten SA, Lim SE, Lai KS, Ibrahim WPW, Ankathil R, et al.
    Biomed Res Int, 2020;2020:6945730.
    PMID: 33062692 DOI: 10.1155/2020/6945730
    Background: The 22q11.2 deletion syndrome (22q11.2DS) is the most common form of deletion disorder in humans. Low copy repeats flanking the 22q11.2 region confers a substrate for nonallelic homologous recombination (NAHR) events leading to rearrangements which have been reported to be associated with highly variable and expansive phenotypes. The 22q11.2DS is reported as the most common genetic cause of congenital heart defects (CHDs).

    Methods: A total of 42 patients with congenital heart defects, as confirmed by echocardiography, were recruited. Genetic molecular analysis using a fluorescence in situ hybridization (FISH) technique was conducted as part of routine 22q11.2DS screening, followed by multiplex ligation-dependent probe amplification (MLPA), which serves as a confirmatory test.

    Results: Two of the 42 CHD cases (4.76%) indicated the presence of 22q11.2DS, and interestingly, both cases have conotruncal heart defects. In terms of concordance of techniques used, MLPA is superior since it can detect deletions within the 22q11.2 locus and outside of the typically deleted region (TDR) as well as duplications.

    Conclusion: The incidence of 22q11.2DS among patients with CHD in the east coast of Malaysia is 0.047. MLPA is a scalable and affordable alternative molecular diagnostic method in the screening of 22q11.2DS and can be routinely applied for the diagnosis of deletion syndromes.

    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  13. Lai MY, Abdul Hamid MH, Jelip J, Mudin RN, Lau YL
    Am J Trop Med Hyg, 2024 Apr 03;110(4):648-652.
    PMID: 38412548 DOI: 10.4269/ajtmh.23-0572
    Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification technique that can amplify specific nucleic acids at a constant temperature (63-65°C) within a short period (<1 hour). In this study, we report the utilization of recombinase-aided LAMP to specifically amplify the 18S sRNA of Plasmodium knowlesi. The method was built on a conventional LAMP assay by inclusion of an extra enzyme, namely recombinase, into the master mixture. With the addition of recombinase into the LAMP assay, the assay speed was executed within a time frame of less than 28 minutes at 65°C. We screened 55 P. knowlesi samples and 47 non-P. knowlesi samples. No cross-reactivity was observed for non-P. knowlesi samples, and the detection limit for recombinase-aided LAMP was one copy for P. knowlesi after LAMP amplification. It has been reported elsewhere that LAMP can be detected through fluorescent readout systems. Although such systems result in considerable limits of detection, the need for sophisticated equipment limits their use. Hence, we used here a colorimetric detection platform for the evaluation of the LAMP assay's performance. This malachite green-based recombinase-aided LAMP assay enabled visualization of results with the naked eye. Negative samples were observed by a change in color from green to colorless, whereas positive samples remained green. Our results demonstrate that the LAMP assay developed here is a convenient, sensitive, and useful diagnostic tool for the rapid detection of knowlesi malaria parasites. This method is suitable for implementation in remote healthcare settings, where centralized laboratory facilities, funds, and clinicians are in short supply.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods
  14. Hamzan NI, Ab Rahman N, Suraiya S, Mohamad I, George Kalarakkal T, Mohamad S
    Arch Oral Biol, 2021 Apr;124:105051.
    PMID: 33581498 DOI: 10.1016/j.archoralbio.2021.105051
    OBJECTIVE: The present study established a real-time loop-mediated isothermal amplification (qLAMP) for rapid detection of human papillomavirus subtype 16 (HPV-16) in oral squamous cell carcinoma (OSCC).

    METHODS: The qLAMP assay was optimized targeting the HPV-16 E7 gene. The analytical sensitivity and specificity of the assay were determined using HPV-18 (ATCC® 45152D™), HPV-35 (ATCC® 40330™), HPV-43 (ATCC® 40338™) and HPV-56 (ATCC® 40549™) viral strains and oral bacteria. HPV-16 standard curve was constructed for determination of HPV-16 viral load. The diagnostic performance of the assay was evaluated from 63 OSCC patients comprising 63 tissue, 13 saliva and 49 blood samples, in comparison with p16 immunohistochemistry (IHC), in-house PCR and nested PCR assays.

    RESULTS: The detection limit of developed LAMP and PCR assays was 4.68 × 101 and 4.68 × 103 copies/μl, respectively. qLAMP assay enabled detection of positive results as early as 23 min at 67 °C. This assay can detect HPV-16 positivity in 23 % (3/13) saliva and 4.8 % (3/63) tissue samples with the viral load ranging from 4.68 × 101 to 4.68 × 104 copies/μl. HPV-16 positivity was not detected in all the blood samples. The sensitivity and specificity of qLAMP were 100 % in comparison with that of p16 IHC and nested PCR.

    CONCLUSION: This study reports for the first time on the use of qLAMP assay for detection of HPV-16 in OSCC in both tissue and saliva as the sample matrix which holds promise in improving the diagnostic application owing to its rapidity, simplicity, high sensitivity and specificity.

    Matched MeSH terms: Molecular Diagnostic Techniques
  15. Lau YL, Anthony C, Fakhrurrazi SA, Ibrahim J, Ithoi I, Mahmud R
    Parasit Vectors, 2013;6(1):250.
    PMID: 23985047 DOI: 10.1186/1756-3305-6-250
    Amebiasis caused by Entamoeba histolytica is the third leading cause of death worldwide. This pathogenic amoeba is morphologically indistinguishable from E. dispar and E. moshkovskii, the non-pathogenic species. Polymerase chain reaction is the current method of choice approved by World Health Organization. Real-time PCR is another attractive molecular method for diagnosis of infectious diseases as post-PCR analyses are eliminated and turnaround times are shorter. The present work aimed to compare the results of Entamoeba species identification using the real-time assay against the established nested PCR method.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  16. Vythalingam LM, Hossain MAM, Bhassu S
    Mol Cell Probes, 2021 02;55:101683.
    PMID: 33259896 DOI: 10.1016/j.mcp.2020.101683
    Invasive alien fish species have become a silent treat towards the ecosystem especially the native fish population in Malaysia. There has been a need to develop rapid identification methods that can aid management teams in identifying fish species that are not native to our ecosystem. Current visual identification methods are highly tedious and require time, delaying action towards curbing the invasion. The LAMP assay successfully identified six popular invasive fish species in Malaysia. None of the LAMP assays showed false positives and the Limit of Detection of the LAMP primers were highly sensitive and could detect DNA samples up to 1 × 10-15 ng/μl. The LAMP primers designed were highly specific to the target species and did not amplify non target species. DNA sequencing was done to ensure the accuracy of LAMP assay results. This study demonstrates that LAMP is a suitable tool in species identification efforts of invasive fish species in Malaysia.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  17. Lee SV, Tai ES, Mutalib AR, Khairani-Bejo S, Bahaman AR
    Trop Biomed, 2011 Dec;28(3):497-505.
    PMID: 22433877 MyJurnal
    A simple and reliable tool for the early diagnosis of leptospirosis is urgently needed. We report the development of a lyophilized reagent-based polymerase chain reaction (PCR) assay targeting lipL32 gene, which is present only in pathogenic leptospires. To determine the effectiveness of the newly developed assay in the early diagnosis of leptospirosis, the sensitivity and specificity was evaluated. In simulated clinical samples, the assay was able to detect 10² and 10³ leptospires/ml in spiked urine and blood samples, respectively. In experimentally infected animals, leptospiral DNA could be detected in blood and lung samples as early as Day 1 post infection. This assay was also shown to be stable and remained sensitive for up to five months at ambient temperature. Hence, this lyophilized reagent-based PCR assay with high specificity, sensitivity and stability would provide a simple, rapid and reliable method in diagnosing acute leptospirosis, especially in the field of veterinary medicine.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  18. Al-Talib H, Yean CY, Al-Khateeb A, Hasan H, Ravichandran M
    J Microbiol Immunol Infect, 2014 Dec;47(6):484-90.
    PMID: 23927820 DOI: 10.1016/j.jmii.2013.06.004
    Methicillin-resistant Staphylococcus aureus (MRSA) is a major pathogen responsible for significant numbers of nosocomial and community-acquired infections worldwide. Molecular diagnosis for MRSA nasal carriers is increasingly important for rapid detection and screening of MRSA colonization because the conventional methods are time consuming and labor intensive. However, conventional polymerase chain reaction (PCR) tests still require cold-chain storage as well as trained personnel, which makes them unsuitable for rapid high-throughput analysis. The aim of this study was to develop a thermostabilized PCR assay for MRSA in a ready-to-use form that requires no cold chain.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*; Molecular Diagnostic Techniques/standards
  19. Abdullah J, Saffie N, Sjasri FA, Husin A, Abdul-Rahman Z, Ismail A, et al.
    Braz J Microbiol, 2014;45(4):1385-91.
    PMID: 25763045
    An in-house loop-mediated isothermal amplification (LAMP) reaction was established and evaluated for sensitivity and specificity in detecting the presence of Salmonella Typhi (S. Typhi) isolates from Kelantan, Malaysia. Three sets of primers consisting of two outer and 4 inner were designed based on locus STBHUCCB_38510 of chaperone PapD of S. Typhi genes. The reaction was optimised using genomic DNA of S. Typhi ATCC7251 as the template. The products were visualised directly by colour changes of the reaction. Positive results were indicated by green fluorescence and negative by orange colour. The test was further evaluated for specificity, sensitivity and application on field samples. The results were compared with those obtained by gold standard culture method and Polymerase Chain Reaction (PCR). This method was highly specific and -10 times more sensitive in detecting S. Typhi compared to the optimised conventional polymerase chain reaction (PCR) method.
    Matched MeSH terms: Molecular Diagnostic Techniques/methods*
  20. Ahmadi SH, Neela V, Hamat RA, Goh BL, Syafinaz AN
    Trop Biomed, 2013 Dec;30(4):602-7.
    PMID: 24522129 MyJurnal
    Peritonitis still remains a serious complication with high rate of morbidity and mortality in patients on CAPD. Rapid and accurate identification of pathogens causing peritonitis in a CAPD patient is essential for early and optimal treatment. The aim of this study was to use 16S rRNA and ITS gene sequencing to identify common bacterial and fungal pathogens directly from the peritoneal fluid without culturing. Ninety one peritoneal fluids obtained from 91 different patients on CAPD suspected for peritonitis were investigated for etiological agents by 16S rRNA and ITS gene sequencing. Data obtained by molecular method was compared with the results obtained by culture method. Among the 45 patients confirmed for peritonitis based on international society of peritoneal dialysis (ISPD) guidelines, the etiological agents were identified in 37(82.2%) samples by culture method, while molecular method identified the etiological agents in 40(88.9%) samples. Despite the high potential application of the 16S rRNA and ITS gene sequencing in comparison to culture method to detect the vast majority of etiological agents directly from peritoneal fluids; it could not be used as a standalone test as it lacks sensitivity to identify some bacterial species due to high genetic similarity in some cases and inadequate database in Gene Bank. However, it could be used as a supplementary test to the culture method especially in the diagnosis of culture negative peritonitis.